Operational Characteristic Analysis of Bipolar DC Distribution System using Hardware Simulator (하드웨어 시뮬레이터에 의한 양극형 직류배전시스템의 동작특성 분석)

  • Lee, Jin-Gyu;Lee, Yoon-Seok;Kim, Jae-Hyuk;Han, Byung-Moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.4
    • /
    • pp.476-483
    • /
    • 2014
  • This paper describes the operational analysis results of the bipolar DC distribution system coupled with the distributed generators. The energy management for AC/DC power trade and the operational principle of distributed generators and energy storages were first analyzed by computer simulation with PSCAD/EMTDC software. After then a hardware simulator for the bipolar DC distribution system was built, which is composed of the grid-tied three-level inverter, battery storage, super-capacitor storage, and the voltage balancer. Various experiments with the hardware simulator were carried out to verify the operation of bipolar DC distribution system. The developed simulator has an upper-level controller which operates in connection with the controllers for each distributed generator and the battery energy storage based on CAN communication. The developed hardware simulator are possible to use in designing the bipolar DC distribution system and analyzing its performance experimentally.

A Study on DC Interruption Technology using a Transformer Type Superconducting Fault Current Limiter to Improve DC Grid Stability (DC 그리드 안정성 향상을 위해 변압기형 초전도 한류기가 적용된 직류 차단 기술에 관한 연구)

  • Hwang, Seon-Ho;Choi, Hye-won;Jeong, In-Sung;Choi, Hyo-Sang
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.4
    • /
    • pp.595-599
    • /
    • 2018
  • Interruption system with the transformer type superconducting fault current limiter(TSFCL) is proposed in this paper. The interruption system with a TSFCL is a technology that it maximizes the interruption function of a mechanical DC circuit breaker using a transformer and a superconducting fault current limiter. By a TSFCL, the system limits the fault current till the breakable current range in the fault state. Therefore, the fault current could be cut off by a mechanical DC circuit breaker. The Interruption system with a TSFCL were designed using PSCAD/EMTDC. In addition, the Interruption system with a TSFCL was applied to the DC test circuit to analyze characteristics of a current-limiting and a interruption operation. The simulation results showed that the Interruption system with a TSFCL interrupted the fault current in a stable when a fault occurred. Also, The current-limiting rate of the Interruption system with a TSFCL was approximately 69.55%, and the interruption time was less than 8 ms.

Investigation of a Hybrid HVDC System with DC Fault Ride-Through and Commutation Failure Mitigation Capability

  • Guo, Chunyi;Zhao, Chengyong;Peng, Maolan;Liu, Wei
    • Journal of Power Electronics
    • /
    • v.15 no.5
    • /
    • pp.1367-1379
    • /
    • 2015
  • A hybrid HVDC system that is composed of line commutated converter (LCC) at the rectifier side and voltage source converter (VSC) in series with LCC at the inverter side is studied in this paper. The start-up strategy, DC fault ride-through capability, and fault recovery strategy for the hybrid HVDC system are proposed. The steady state and dynamic performances under start-up, AC fault, and DC fault scenarios are analyzed based on a bipolar hybrid HVDC system. Furthermore, the immunity of the LCC inverter in hybrid HVDC to commutation failure is investigated. The simulation results in PSCAD/EMTDC show that the hybrid HVDC system exhibits favorable steady state and dynamic performances, in particular, low susceptibility to commutation failure, excellent DC fault ride-through, and fast fault recovery capability. Results also indicate that the hybrid HVDC system can be a good alternative for large-capacity power transmission over a long distance byoverhead line.

Interrupting characteristics of the transformer superconducting fault current limiter

  • Hwang, S.H.;Choi, H.W.;Jeong, I.S.;Choi, H.S.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.19 no.4
    • /
    • pp.40-44
    • /
    • 2017
  • This paper analyzed the fault current limiting characteristics of the previously proposed transformer superconducting fault current limiter (TSFCL) interruption system according to its transformer type. The TSFCL interruption system is an interruption technology that combines a TSFCL, which uses a transformer and a superconductor, and a mechanical DC circuit breaker. This technology first limits the fault current using the inductance of the transformer winding and the quench characteristics of the superconductor. The limited fault current is then interrupted by a mechanical DC circuit breaker. The magnitude of the limited fault current can be controlled by the quench resistance of the superconductor in the TSFCL and the turns ratio of the transformer. When the fault current is controlled using a superconductor, additional costs are incurred due to the cooling vessel and the length of the superconductor. When the fault current is controlled using step-up and step-down transformers, however, it is possible to control the fault current more economically than using the superconductor. The TSFCL interruption system was designed using PSCAD/EMTDC-based analysis software, and the fault current limiting characteristics according to the type of the transformer were analyzed. The turns ratios of the step-up and step-down transformers were set to 1:2 and 2:1. The results were compared with those of a transformer with a 1:1 turns ratio.

Characteristic Analysis of Jeju-Hanam transmission using VSC-HVDC (전압원 HVDC를 이용한 제주-해남 계통 특성 분석)

  • Park, Yong-Hee;Baek, Seung-Taek;Choi, Jun-Young;Han, Byung-Moon
    • Proceedings of the KIEE Conference
    • /
    • 2006.04b
    • /
    • pp.238-240
    • /
    • 2006
  • 논문은 전류원 HVDC로 연계되어 있는 제주-해남 계통을 전압원 HVDC로 연계하였을 경우에 대한 특성 분석에 대해서 기술하고 있다. 기존의 제주-해남 HVDC시스템은 교류계통 전압의 외란에 의해서 전류실패가 발생할 수 있으므로 연계되는 교류계통 모선에 무효전력보상설비들이 설치되어 있다. 따라서 기존의 전류원 HVDC 시스템은 대용량의 전력을 전송할 수 있다는 장점이 있는 반면 추가로 무효전력 보상설비들이 설치가 되어야 한다는 단점이 있기 때문에 최근에 선진국에서는 전압원 HVDC 시스템에 대한 연구가 활발히 진행되고 있다. 전압원 HVDC 시스템은 계통사고 또는 교류전압강하로 인한 전류실패가 발생하지 않고, 무효전력을 HVDC 시스템의 용량내에서 유효전력과 독립적으로 제어될 수 있기 때문에 추가로 무효전력 보강설비가 필요하지 않다는 장점이 있다. 본 논문에서 늘 제주-해남 계통을 전압원 HVDC로 연계하는 모델을 PSCAD/EMTDC를 이용해서 개발하였다. 개발된 시뮬레이션 모델은 전압원 HVDC를 이용해서 제주-해남 계통을 연계하였을 경우에 대한 동특성을 분석하는데 유용하리라 사료된다.

  • PDF

A Novel Operational Method of PV Power Generation System for SPE (수소제조시스템을 위한 새로운 태양광발전시스템 운전기법에 관한 연구)

  • Choi, Jong-Ho;Lee, Dong-Han;Kim, Jong-Hyun;Kim, Jae-Ho;Park, Min-Won;Yu, In-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2006.04b
    • /
    • pp.408-410
    • /
    • 2006
  • To chase maximum power point at every moment under a conventional MPPT control method, a voltage and current coming out from PV-cell are needed to be feedbacked. So, the structure of control circuit becomes so complex and the MPPT control is in risk of control failure. In the newly developed control method, the current flowing into SPE cell is the only one considerable factor. So, the structure of control circuit becomes simple and the manufacturing cost of the control device decreases. Especially, in case of a huge system of PV-SPE system, because the voltage coming out from PV-cell is not needed to be feed backed, this system can be operated much more safely. In this paper, the PV-SPE system was actually manufactured based on the simulation model of PSCAD/EMTDC program and the results tested were shown. Authors are sure that it is the most useful method to maximize power from PV to SPE with only a feedback of SPE input current.

  • PDF

Response Characteristic of HVDC System According to Frequency Sensing Methods (주파수 측정방법에 따른 HVDC시스뎀의 응답특성)

  • Kim C,K;Yang B.M;Park J.G.;Jeong G.J.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.299-303
    • /
    • 2003
  • This paper deals with the frequency sensing methods at HVDC system. The objects of frequency information in HVDC system areto fire a valve and to control a frequency of AC network. Conventionally, there are two methods to measure a frequency of AC network. The first method is to draw out from the synchronous machine and the second method is from AC network. Two methods have advantages and disadvantage each other. For the extreme case of a receiving system of zero inertia (no generation), synchronous machine is essential. In this situation, the frequency information received from the synchronous machine shaft. However, the speed of synchronous machine is oscillated when a disturbance in AC network occurs, and HVDC may be oscillated due to an oscillation speed. To solve this drawback, in this paper, new frequency sensing method is proposed. A proposed method that is use a modified curve-fitting algorithm, has a robust characteristics against a harmonics and unbalanced faults. Consequently, A proposed method is verified by PSCAD/EMTDC Program and experimental test.

  • PDF

Islanding detection algorithm for a micro-grid based on the active and reactive power in the time domain (시간영역에서의 유효/무효전력을 이용한 마이크로그리드의 단독운전의 판단 알고리즘)

  • Lee, Young-Gui;Lee, Hye-Won;Kim, Yeon-Hee;Zheng, Tai-Ying;Kang, Yong-Cheol
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.145-146
    • /
    • 2011
  • A micro-grid (MG) is usually interconnected to the main grid through the dedicated line. Immediately after the removal of the grid supply, the MG should be disconnected and remain disconnected until the main grid is re-energized. It should detect islanding condition as soon as it happens to adjust the setting of the protection relays in the MG. This paper proposes an islanding detection algorithm for the MG based on the active and reactive power delivered to the dedicated line in the time domain. The performance of the proposed algorithm is verified under islanding conditions and fault conditions using the PSCAD/EMTDC simulator. The results indicate that the proposed algorithm can discriminate the islanding conditions from the various fault conditions.

  • PDF

Application of an Adaptive Step-size Algorithm to the Power System Model of Dispatcher Training Simulator (적응 간격 크기 셈법을 이용한 급전운영자 훈련 프로그램 용 전력계통 시뮬레이터 개발)

  • Hwang, Pyeong-Ik;Ahn, Seon-Ju;Moon, Seung-Il;Yoon, Yong-Tae;Hur, Seong-Il
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.3
    • /
    • pp.492-498
    • /
    • 2010
  • Since it is almost impossible to train the dispatchers with real power system, the dispatcher training simulator(DTS) is used for the training. Among various components of the DTS, the power system model(PSM) emulates the dynamic behavior of the power system to calculate the frequency and voltage. The frequency is calculated from various parameters such as mechanical power of power plants, load, inertia, and the damping of the power system. In the PSM, the power plants are modeled as differential equations, so the mechanical power of the power plants are calculated by the numerical methods. Conventionally, the fixed step-size algorithm has been used in the PSM, however it has some drawbacks. This paper develops the prototype PSM using the Matlab, and analyzes the problems of the fixed step-size algorithm by comparing the results with those of PSCAD simulation. In order to overcome the limitations, this paper proposes a modified frequency calculation method using the adaptive step-size algorithm. From the simulation using the proposed method, it is verified that the accuracy of frequency calculation increases substantially while the simulation time is not greatly increased.

Analysis on Recloser-Fuse Coordination in a Power Distribution System linked Small Scale Cogeneration System with Superconducting Fault Current Limiter (소형 열병합발전 시스템이 연계된 배전계통에 초전도 전류제한기 적용시 리클로져-퓨즈 협조 분석)

  • Kim, Myoung-Hoo;Kim, Jin-Seok;Moon, Jong-Fil;Lim, Sung-Hun;Kim, Jae-Chul;Lee, Joon-Kyu
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.3
    • /
    • pp.499-505
    • /
    • 2010
  • This paper analyzed that the coordination of recloser-fuse when a superconducting fault current limiter (SFCL) is installed to a power distribution system linked small scale cogeneration system. As a rule, the recloser to properly protect against both permanent and temporary fault is installed to upstream of fuse. Therefore, in a power distribution system linked small scale cogeneration system, the fault current is increased by adding fault current of small scale Cogeneration system when a permanent fault occurs, and the fuse could melt during the first fast operation of the recloser because of more sufficient heat from the increased current. However, when SFCLs are applied into a power distribution system linked small scale cogeneration system, the coordination of recloser-fuse could be accomplished due to decreased fault current as the effect of the impedance value of the SFCL. Therefore, to solve these problems, we analysed the operation of recloser-fuse coordination in a power distribution system linked small scale cogeneration system with SFCL using PSCAD/EMTDC.