• 제목/요약/키워드: PSC standards

검색결과 14건 처리시간 0.018초

Reliability analysis of concrete bridges designed with material and member resistance factors

  • Paik, Inyeol;Hwang, Eui-Seung;Shin, Soobong
    • Computers and Concrete
    • /
    • 제6권1호
    • /
    • pp.59-78
    • /
    • 2009
  • Reliability analysis for a proposed limit state bridge design code is performed. In order to introduce reliability concept to design code, the proposed live load model is based on truck weight survey. Test data of domestic material strengths are collected to model statistical properties of member strengths. Sample RC and PSC girder sections are designed following the safety factor format of the proposed code and compared with the current design practice. Reliability indexes are calculated and examined for material and member resistance factor formats and sample calibrations of safety factors are presented. It is concluded that the proposed code provides reasonable level of reliability compared to the international design standards.

국내 설계하중의 피로특성을 적용한 고주탑 엑스트라도즈드교의 성능개선에 관한 연구 (A Study on the Performance Improvement of High-Pylon Extradosed Bridge adopting Fatigue Loading Condition)

  • 이영진;신승교;임윤묵
    • 대한토목학회논문집
    • /
    • 제30권2A호
    • /
    • pp.137-148
    • /
    • 2010
  • 본 연구에서는 기존 엑스트라도즈드교와 PSC 사장교 사이의 영역인 주탑고비 1/6~1/7의 고주탑을 적용하여 엑스트라도즈드교의 구조적, 경제적 특성을 평가하였다. 주탑고가 증가함에 따라 사재의 연직하중 분담율의 증가와 함께 변동응력도 증가하여 사재의 피로안정성이 주요 설계변수임을 알 수 있었다. 국내에서는 엑스트라도즈드교의 설계기준 부재로 인하여 일본 설계기준을 준용하고 있다. 또한, 피로 검토하중도 정립되지 않고 있어 본 연구에서는 일본 피로 검토하중에 대응하는 국내 활하중을 적용 검토하여 DL24 하중이 피로 검토하중으로 적정함을 알 수 있었다. 제시된 피로 검토하중을 적용하여 주탑고, 주거더의 강성, 케이블 면수 등을 매개변수로 엑스트라도즈드교의 구조적, 경제적 특성을 검토하였다. 본 연구의 결과로써 일면 케이블 배치가 이면 케이블 배치보다 경제적임을 알 수 있었다. 또한, 주탑고비가 1/6의 변단면 고주탑 엑스트라도즈교에서 연직 하중분담율이 30~50% 이내로 모든 사재가 허용변동응력 이내로 들어와 사재를 효율적으로 사용할 수 있어 가장 경제적임을 알 수 있었다. 본 연구를 통해 기존의 엑스트라도즈드교보다 높은 주탑고를 적용함에 따라 구조적, 경제적으로 효율성을 높일 수 있음을 확인하였다.

Improved prestressed concrete girder with hybrid segments system

  • Yim, Hong Jae;Yang, Jun Mo;Kim, Jin Kook
    • Structural Engineering and Mechanics
    • /
    • 제65권2호
    • /
    • pp.183-190
    • /
    • 2018
  • The prestressed concrete (PSC) technology that was first developed by Freyssinet has significantly improved over the past century in terms of materials and structural design in order to build longer, slender, and more economic structures. The application of prestressing method in structures, which is determined by the pre-tension or post-tension processes, is also affected by the surrounding conditions such as the construction site, workforce skills, and local transportation regulations. This study proposes a prestressed concrete girder design based on a hybrid segment concept. The adopted approach combines both pre-tension and post-tension methods along a simple span bridge girder. The girder was designed using newly developed 2400 MPa PS strands and 60 MPa high-strength concrete. The new concept and high strength materials allowed longer span, lower girder depth, less materials, and slender design without affecting the lateral stability of the girder. In order to validate the applicability of the proposed hybrid prestressed segments girder, a full-scale 35 m girder was fabricated, and experimental tests were performed under various fatigue and static loading conditions. The experimental results confirmed the feasibility of the proposed long-span girder as its performance meets the railway girder standards. In addition, the comparison between the measured load-displacement curve and the simulation results indicate that simulation analysis can predict the behavior of hybrid segments girders.

대심도 복층터널 프리캐스트 중간슬래브의 횡방향 현장이음방식에 대한 실험연구 (The Experimental Study on Transverse Field Joint Method of Precast Road Deck Slab of Double Deck Tunnel in Great Depth)

  • 이두성;김보연;배철기;허재훈
    • 콘크리트학회논문집
    • /
    • 제29권1호
    • /
    • pp.23-32
    • /
    • 2017
  • 대심도 복층터널 구조물에서 중간슬래브 구조에 적용되는 형식중 하나인 프리캐스트 구조에서는 차량 진행 방향으로 이음이 발생한다. 따라서, 이 이음부를 일체로 거동하게 하는 것이 중요하다. 이 연구에서 제안하는 대심도 복층터널 중간슬래브는 터널의 공간 활용을 극대화 하기 위하여 프리스트레스를 도입한 보 형식의 구조체로, 'PS 이음방식'과 '볼트체결방식'에 대한 이음방법을 개발하였다. 또한, 두 가지 이음방식을 적용한 중간슬래브의 구조성능을 평가하기 위해서 실물모형 구조실험을 수행하였으며, Contact 모델을 적용한 FEM 해석을 통해서 구조적인 안정성을 검증하였다. 이음방식을 적용한 복층터널 중간슬래브의 정적재하실험 결과 매우 안정적인 거동을 보였으며, 균열 및 처짐에 있어 도로교설계기준(2011)을 만족하여 사용성에도 문제가 없다고 판단되었다. FEM 해석에 따른 중간슬래브의 거동은 실험과 비교하여 강성이 미소하게 크게 나타났으나 전체적인 거동이 거의 유사하게 나타났다. 따라서 이 연구에서 개발한 이음방법을 적용한 중간슬래브를 시공함에 있어 구조적으로 문제가 없을 것으로 판단된다.