• 제목/요약/키워드: PRPD

검색결과 34건 처리시간 0.023초

카오스이론을 이용한 GIS 내부 절연결함 판별 (Discrimination of insulation defects in a Gas Insulated Switchgear (GIS) by use of a neural network based on a Chaos Analysis of Partial Discharge(CAPD))

  • 임윤석;이동일;구자윤;김정태;방항권
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.2223-2225
    • /
    • 2005
  • In this work, experimental investigation has been mainly done. For this purpose, UHF sensor has been designed and fabricated to detect the partial discharges produced from the 10 artificial defects introduced into the real scale 70kV GIS mock-up under the high voltage at the well shielded room. And also, in order to verify the applicability of the proposed method at the site, the proposed CAPD (chaos analysis of partial discharge) is combined with spectral analysis method in order to identify the nature of the above 10 defects. The PD pattern recognition of each defect has been fulfilled by applying self developed artificial neural network soft ware. The result shows that the recognition rate is reached to be 80% by newly proposed method while the traditional PRPD analysis method leads us to obtain 41%. In consequence, it can be pointed out that the proposed method seems likely to be applicable to the real GIS at the site.

  • PDF

TEV 검출에 의한 가스 절연 개폐기의 절연 진단 (Insulation Diagnosis of Gas-Insulated Switchgears by TEV Detection)

  • 공정배;길경석;김성욱
    • 한국전기전자재료학회논문지
    • /
    • 제32권4호
    • /
    • pp.307-312
    • /
    • 2019
  • Transient earth voltage (TEV) signals propagate on metal surfaces when partial discharge (PD) occurs due to the deterioration of insulation performance in the operation of gas-insulated switchgears (GIS). A TEV sensor has advantages of high sensitivity and convenient installation for detecting PD defects. However, the TEV sensor depends on imports in domestic and detailed studies have not been conducted. In this study, a sensor was designed and fabricated by the TEV principle and its response characteristics were evaluated for detecting PD defects, which were simulated as protrusion on conductor (POC), protrusion on enclosure (POE), and free moving particle (FMP) defects. Finally, the PD-induced TEV signals were measured and phase-resolved partial discharge (PRPD) patterns were analyzed to identify the type of defect.

몰드 변압기의 절연 진단을 위한 로고우스키형 부분방전 센서의 설계 및 제작 (Design and Fabrication of Rogowski-type Partial Discharge Sensor for Insulation Diagnosis of Cast-Resin Transformers)

  • 이경렬;김성욱;길경석
    • 한국전기전자재료학회논문지
    • /
    • 제35권6호
    • /
    • pp.594-602
    • /
    • 2022
  • Cast-resin transformers are widely installed in various electrical power systems because of their low operating cost and low influence on external environmental factors. However, when they have an internal defect during the manufacturing process or operation, a partial discharge (PD) occurs, and eventually destroys the insulation. In this paper, a Rogowski-type PD sensor was studied to replace commercial PD sensors used for the insulation diagnosis of power apparatus. The proposed PD sensor was manufactured with four different types of PCB-based winding structures, and it was analyzed in terms of the detection characteristics for standard calibration pulses and the changes of the output voltage according to the distance. The output increased linearly in accordance with the applied discharge amount. It was confirmed that the hexagon structure sensor had the highest sensitivity, because the winding cross-sectional area of the sensor was larger than others. In addition, as the distance from the defect increased, the output voltage of the sensors decreased by 7.32% on average. It was also confirmed that the attenuation rate according to the distance decreased as the input discharge amount increased. For the application of this new type sensor, PD electrode system was designed to simulate the void defect. Waveforms and PRPD patterns measured by the proposed PD sensors at DIV and 120% of DIV were the same as the results measured by MPD 600 based on IEC 60270. The proposed PD sensors can be installed on the inner wall of the transformer tank by coating its surfaces with a non-conductive material; therefore, it is possible to detect internal defects more effectively at a closer distance from the defect than the conventional sensors.

우리나라 영아에서 PRP-T(HiberixTM)백신의 면역원성 및 안전성에 대한 연구 (Immunogenicity and Safety of a Haemophilus influenzae Type b Polysaccharide-Tetanus Toxoid Conjugate Vaccine (PRP-T: HiberixTM) in Korean Infants)

  • 정은희;김예진;김윤경;김동호;서정완;이환종
    • Pediatric Infection and Vaccine
    • /
    • 제10권1호
    • /
    • pp.71-80
    • /
    • 2003
  • 목 적 : b형 Haemophilus influenzae(Hib)의 피막 다당질인 polyribosyl -ribitol-phosphate(PRP)가 Hib 질환의 발병기전에 중요한 역할을 하며, 이에 대한 항체가 있으면 Hib 질환을 예방할 수 있다. Hib 질환을 예방하기 위해 개발된 단백 결합 백신에는 PRP-D, PRP-T, PRP-OMP 및 PRP-CRM197 등이 있다. Hib 피막 다당질에 대한 항체 반응은 백신에 사용된 결합 단백의 종류에 따라 다르지만 인종이나 제조 회사에 따라서 유효성 및 안전성에 차이가 있을 수 있다. PRP-T에는 기존에 국내에 공급되던 $ActHib^{(R)}$(Aventis)와 최근에 국내에 도입되기 시작한 $Hiberix^{TM}$(GlaxoSmithKline Biologicals)가 있다. 본 연구에서는 우리나라 영아에서 PRP-T 백신인 $Hiberix^{TM}$의 면역원성 및 안전성을 평가하고자 하였다. 방 법 : 2001년 3월부터 2002년 4월까지 소아과에 예방접종을 위해 내원한 건강한 생후 2개월 이상의 영아 73명(남아 43명)을 대상으로 하였다. 생후 2, 4, 6개월에 PRP-T 백신($Hiberix^{TM}$)을 필요한 경우에 DTaP, TOPV, B형 간염백신과 같이 접종하였고, 1회 접종 전(2개월), 2회 접종 2개월 후(생후 6개월) 그리고 3회 접종 1개월 후(생후 7개월)에 혈청내 항 PRP 항체가를 효소면역법(ELISA)으로 측정하였다. 매 접종 후 72시간내에 발생하는 국소적, 전신적 이상반응을 관찰하였다. 면역원성은 계획한대로 접종을 완료한 영아에 대하여 분석하였으며, 이상반응은 1회 이상 접종받은 모든 영아에 대하여 분석하였다. 결 과 : 73명 중 63명(남아 37명)이 계획한대로 접종을 완료하였다. 생후 2개월에 측정한 접종 전항 PRP 항체가의 기하 평균치는 0.17 ${\mu}g/mL$(95% CI; 0.13~0.22)이었다. 2회 접종 후(생후 6개월) 항체가의 기하 평균치는 4.14 ${\mu}g/mL$(95% CI; 2.65~6.48), 3회 접종 후(생후 7개월)의 기하 평균치는 14.65 ${\mu}g/mL$(95% CI; 10.83~19.81)이었다. 항체가가 1.0 ${\mu}g/mL$ 이상인 비율은 2회 접종 후 77.8% (95% CI; 67.5~88.0), 3회 접종 후 98.4%(95% CI;95.3~100)이었다. 백신 접종 후 발생한 이상반응중 전신반응으로서 보챔(45.5%)이 가장 많았고 졸음(30.5%), 수유감소(26.7%), 발열(5.6%) 순이었다. 국소반응으로서 동통이 7.9%, 발적(${\geq}5$ mm) 2.8%, 부종(${\geq}5$ mm) 1.8% 순이었다. 이러한 이상반응은 대부분 경증으로 모두 회복되었다. 결 론 : 결론적으로, PRP-T 백신인 $Hiberix^{TM}$는 우리나라 영아에서 우수한 면역원성과 안전성을 보였으며, 특히 2회 접종으로도 항체가의 기하 평균치가 장기적인 방어 수준으로 상승함은 과거의 다른 PRP-T 백신($ActHib^{(R)}$)의 연구 결과들과 일치하는 소견으로 향후 국내에서 PRP-T 백신의 접종 방법에 대한 재고가 필요하다고 사료된다.

  • PDF