• Title/Summary/Keyword: PROTECTING EQUIPMENT

Search Result 71, Processing Time 0.025 seconds

A Study on Guarding Security Portion in Protecting Operation and Application of Electronic Security (경호업무의 경비영역과 기계경비의 적용 방안)

  • Chung, Tae-Hwang
    • Korean Security Journal
    • /
    • no.4
    • /
    • pp.319-341
    • /
    • 2001
  • Most of protecting security activity is carried out by manpower partly by security equipment. The protecting security market and the area of protecting security activity is increasing in spite of change of economic and social environment situation. For more effective protecting security activity, the coordination of electronic equipment and manpower is required. So some application method is suggested throughout the thesis, which is especially focused on new approaching method. The integration of intrusion detecting system, C.C.TV system and Access control system is introduced for general application in chapter III, and some application systems are proposed for protecting security activity in chapter IV. But the security equipment is only aid for manpower, so manpower and equipment should be coordinated well.

  • PDF

Study on Radiation Limit of ISM Equipment for Protecting Radio Device (무선기기 보호를 위한 ISM 기기의 방사 한계치에 관한 연구)

  • Shim, Yong-Sup;Lee, Il-Kyoo;Hong, Seon-Eui
    • Journal of Satellite, Information and Communications
    • /
    • v.6 no.2
    • /
    • pp.10-14
    • /
    • 2011
  • This paper suggests the method to calculate radiation limit of ISM(Industrial Scientific Medical) equipment in order to protect radio device in the situation that ISM equipment and radio device are operated in near distance. The factor for correction and protection ratio which is need for protecting radio device were considered to calculate radiation limit of ISM equipment. Also, the scenario which is required to limit radiation power of ISM equipment was referred and the S/W for calculation of radiation limit was developed by using GUI(Graphical User Interface) on Matlab. The suggested method for calculation of radiation limit of ISM equipment will be used to protect radio device from ISM equipment.

Electronic Dash-pot System Development for Power Electronic Circuit Protection using the Current Sensor

  • Kim, Chul-Ki;Ryu, Jae-Heun;Yoon, Dal-Hwan
    • Proceedings of the IEEK Conference
    • /
    • 2002.07c
    • /
    • pp.1401-1403
    • /
    • 2002
  • This paper presents the development of an electronic dash-pot(EDP) system it)r protecting the power electronic circuit. The EDP play role protecting an equipment by disconnecting between voltage source and load system. Also, converting the existed electrical system into an electronic mechanism, it can reduce the power consumption and prevents the system damage due to over current.

  • PDF

A Study on Driving Algorithm and Communication Characteristics for Remote Control of Mini Excavator (소형 굴삭기의 원격제어를 위한 주행 알고리즘 및 통신특성에 관한 연구)

  • Jeong, Jin Beom;Kim, Kyung Soo
    • Journal of Drive and Control
    • /
    • v.15 no.4
    • /
    • pp.81-90
    • /
    • 2018
  • Indoor construction site such as building demolition sites, tunnel, vinyl house, and cattle shed are subject to various risk factors such as falling stones, soot and bad odors. However, most of the mini excavators have no cabin that can protect the driver from such risk factors. Therefore, researches on remote control technology of construction equipment are actively conducted as a method for protecting the driver from the risk factors occurring in the working environment. For effective remote control, it is necessary to be able to control the travelling and work using a portable small transmitter. However, due to the limitation of the size of the transmitter, complex operation control is required to control two or more actuators with a single joystick. Also, it is essential to check how remote control characteristics change in various environments such as distance, signal strength, obstacle. Therefore, in this study, an algorithm that can control two actuators simultaneously with a single joystick signal was developed, and a communication method suitable for indoor and outdoor mini construction equipment by analyzing experimentally how the remote control characteristics vary according to various work environments and telecommunication methods proposed.

FEA Procedure for Design Certification of Drillship Flare System (드릴십용 플레어 시스템의 설계승인을 위한 전산해석 절차)

  • Choi, Joo Hyoung;Heo, Tae Wook
    • Transactions of the KSME C: Technology and Education
    • /
    • v.1 no.1
    • /
    • pp.27-31
    • /
    • 2013
  • The Flare system is the offshore plant equipment for protecting humans and equipments from high heat radiations of waste gas and oil burning. As Primary equipment of well test systems, the flare system is essential Class(DNV, ABS etc) design certification. Therefore, this paper is introduced to be related to computational analysis of flare system design certification procedure.

A Study on Development of Interlocking Inspection System for Electronic Interlocking System (전자연동장치의 연동검사시스템 개발)

  • 박영수;이기서
    • Journal of the Korean Society for Railway
    • /
    • v.5 no.2
    • /
    • pp.104-111
    • /
    • 2002
  • The purpose of interlocking system was to prevent the route for a train being set up and its protecting signal cleared if there was already another, conflicting route set up and the protecting signal for that route cleared. This paper proposed Interlocking Inspection System(IIS) consisting of interlocking simulator and field simulator to operate interlocking test of computer based Electronic Interlocking System(EIS) in this paper. Interlocking simulator consists of Design Edit System(DES), Logical Database Management Tool(LDMT) and real-time confirming system, field simulator is a equipment to simulate a control object of EIS and constitutes configuration operated in 19 inch standard rack. As a result of test to prove capacity of this IIS, the efficiency was shown as excellent. Therefore by using inspection system, we obtain every advantages. It has the functions for test data generation and automatic test execution based on personal computer. Time and cost for test work can be reduced more efficiently by using this developed inspection system

Protecting of Electrical Equipment Faults Caused by Magpie (까치에 의한 전력설비 피해방지 대책)

  • Bang, J.S.;Lee, J.S.;Park, Y.K.;Lim, K.J.;Jeong, K.H.;Choi, S.C.;Sin, S.S.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1663-1665
    • /
    • 1998
  • The power distribution system is 22.9 kV-y neutral point multi-ground one in our country. So, if conducting materials contacted, to the power line electrical equipment faults or stoppage of electrical power supply happened in the line. contacts are caused by magpie or its nest materials, especially, electrical power incidents by magpie from February to May, season layed egg, is high as 30% as. It is important to electrical power supplier to protect electrical power equipment caused by magpie. From now, KEPCO have tried to protect electrical power equipment faults caused by magpie using several methods, but have not acquired good results and continued to withdraw the nest. Recently, nature environment protection expand to around country and KEPCO also changed the nest withdrawal method to new pre-protection method coexisted with magpie, "Environmental Affinitive Pre-protection Counterplan". Therefore, we planned environmental affinitive pre-protection equipment, set test line. Also, after analyzed its effects during 1 year, we satisfied with results, and then expanded to other test lines and regions.

  • PDF

Experimental Examinations on Protective Effects of SPDs Associated with the Protective Distance and Type of Load (보호거리와 부하 유형에 따른 SPD의 보호효과에 대한 실험적 고찰)

  • Lee, Bok-Hee;Kim, You-Ha;Ahn, Chang-Hwan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.10
    • /
    • pp.81-88
    • /
    • 2012
  • Surge protective devices(SPDs) are widely used as a most effective means protecting the electrical and electronic equipment against overvoltages such as lightning and switching surges. When installing SPDs, it is essential that the voltage protection level provided by SPDs should be lower than the withstand voltage of the equipment being protected. But even the proper selection of SPDs are achieved, the voltage at the equipment terminal may be higher than the residual voltage of SPD due to the reflection and oscillation phenomena. This paper was focused on the investigations of the conditions for which the equipment is protected by an SPD taking into account the influences of the protective distance and type of load. The protective effects of SPD with voltage-limiting component were analyzed as functions of types of load and protective distance between the SPD and load. As a result, in the cases of long protective distances, capacitive loads and loads with high resistance, the voltage at the load terminal was significantly higher than the residual voltage of SPD. It was found that the proper installation of SPDs should be carried out by taking into account the protective distance and type of load to achieve reliable protection of electronic equipments against surges.

Status and Perspective of Product Noise Labeling (소음표시제의 현황과 전망)

  • Kim, Dae-Joon;Lee, J.W.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.100-103
    • /
    • 2005
  • The aim of the product noise labeling is to harmonize the noise control act relating to noise emission standards, conformity assessment procedure, marking, technical documentation and collection of data concerning the noise emission in the environment of equipment for use outdoors. It will contribute to the smooth functioning of the internal market, while protecting human health and well-being.

  • PDF

Protecting electronic equipment against lightning surge (정밀기기의 낙뢰서지 대책에 관한 연구)

  • 임순재;이주광;이완규;최만용
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.04b
    • /
    • pp.358-362
    • /
    • 1995
  • Precision electronic equipments are composed of sophisticated microcircuits that are extremely vulnerable to lightning-caused voltage spike. This transient voltage spike may cause upset, latent failure or interference on electronic equipments. In order to develop efficient lightning protection measures on AC power lines for a road traffic controller, experimental surge immunity tests were conducted according to IEC standard 801-5. The combination of gas tube arrester and metal-oxide varistor was installed at the input of AC power lines and the silicon avalanche suppressor installed at the output of DC power supply as lightning protection measures.

  • PDF