• Title/Summary/Keyword: PPG Sensor

Search Result 78, Processing Time 0.028 seconds

A study on the pulse measurement system of hybrid type using by flexible sensor and PPG (Flexible sensor와 PPG를 이용한 하이브리드형 맥박 측정 장치에 관한 연구)

  • Kim, Sheen-Ja;Jo, Sung-Hyun;Lee, Young-Woo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.10a
    • /
    • pp.444-446
    • /
    • 2009
  • 현재 대다수의 맥박(또는 심박) 측정 장치는 electrodes와 PPG로 국한되어 있다. 그러나 electrodes는 착용자의 불편감과 수입 의존성에 의한 높은 가격이라는 단점을 가지고 있으며, PPG는 동잡음에 약하다는 단점을 갖는다. 본 논문에서는 PPG와 flexible sensor를 동시 적용하여 상호 작용하게 함으로서 각 센서들의 단점을 보완 해줄 수 있는 하이브리드형의 맥박 측정 장치에 대하여 연구하였다.

  • PDF

Implementation of Heart Rate Monitoring System using PPG Sensor (PPG 센서를 이용한 심박 모니터링 시스템 구현)

  • Lee, Won-Seok;Jung, Kyung Kwon
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.5
    • /
    • pp.138-142
    • /
    • 2017
  • Photoplethysmography (PPG) is a simple and low-cost optical technique that can be used to detect blood volume changes in the microvascular bed of tissue. It is often used non-invasively to make measurements at the skin surface. In this paper, we described the implementation heart rate monitoring system using PPG sensor. Proposed system is collected data using PPG sensor and heart rate was detected using second derivative method. In order to verify the effectiveness of the proposed method, we performed the measurements of RR-intervals with a commercial medical device.

Implementation and evaluation of the sensor assessing pressure and photoplethysmogram (압력맥파 및 광전용적맥파 검출용 일체형 센서의 구현 및 평가)

  • Kim, Gi-Ryon;Kim, Gwang-Nyeon;Choi, Byeong-Cheol;Jeon, Gye-Rok;Ham, Ki-Young;Suh, Duk-Joon;Jung, Dong-Keun
    • Journal of Sensor Science and Technology
    • /
    • v.15 no.2
    • /
    • pp.106-111
    • /
    • 2006
  • Pulse sensors generally have characteristics that cause a analytical error by the interference of signals according to tiny motion of body and pressure applied to skin. To resolve this problem, we implemented the sensor that is capable of simultaneously measuring pressure and PPG(photoplethymogram) in a state attached to skin. Pressure and PPG was recorded at the finger and wrist respectively to evaluate the usefulness of the implemented sensor. Then, it was observed that the shape of PPG from sensor changed by pressure pushing down skin. Results of this study suggested that it is possible to monitor a degree of skin pressurization and to guarantee a reliable measurement by simultaneously measuring pressure and PPG using implemented integrated sensor when measuring PPG on the wrist or the finger.

A Study on the Relationship between Ultraviolet Rays and Skin Color Using a Photoplethysmography Sensor

  • So-Yae Hur;Sun-Jib Kim
    • International Journal of Advanced Culture Technology
    • /
    • v.11 no.1
    • /
    • pp.363-369
    • /
    • 2023
  • In this study, to check the function of managing the severity of ultraviolet rays with a smart watch, a popular health care IT device, It was tested whether measuring heart rate using a PPG(Photoplethysmography) sensor representatively used in a smart watch could tell skin changes caused by ultraviolet rays. Through this experiment, we examined the possibility that the skin color tanned by ultraviolet rays can be determined only by the heart rate measurement function of the PPG sensor. In addition, the possibility of expanding the heart rate measurement function of the PPG sensor to the use of skin condition management was considered. we used an Arduino-based reflective PPG sensor to measure changes in heart rate by selecting body sites with high and low UV rays exposure. A significant value was derived through tests considering factors such as gender, UV exposure, and age. As a result, the study identified the possibility of adding ultraviolet rays and skincare items to future smart watch healthcare items and the possibility of expanding skin measurement methods. It is also possible to suggest the direction of future research.

Non-Intrusive Healthcare System for Estimation of Vascular Condition in IP-Enabled Wireless Network (IP 기반 무선네트워크에서의 혈관상태 평가를 위한 무구속 헬스케어 시스템)

  • Jung, Sang-Joong;Kwon, Tae-Ha;Chung, Wan-Young
    • Journal of Sensor Science and Technology
    • /
    • v.22 no.1
    • /
    • pp.76-83
    • /
    • 2013
  • A real-time wireless monitoring and analysis methods using the wearable PPG sensor to estimate cardiovascular condition is studied for ubiquitous healthcare service. A small size and low-power consuming wearable photoplethysmogram (PPG) sensor is designed as a wrist type device and connected with the IP node assigned its own IPv6 address. The measured PPG waveform in the IP node is collected and transferred to a central server PC through the IP-enabled wireless network for storage and analysis purposes. A monitoring and analysis program is designed to process the accelerated plethysmogram (APG) waveform by applying the second order derivatives to analyze systolic waves as well as heart rate variability analysis from the measured PPG waveform. From our results, the features of cardiovascular condition from individual's PPG waveform and estimation of vascular compliance by the comparison of APG-aging index (AI) and ratio of LF/HF are demonstrated.

Design of Filter to Reject Motion Artifacts of PPG Signal Using Multiwave Optical Source (다파장 광원을 이용한 광용적 맥파의 동잡음 제거 필터 설계)

  • Park, Heejung;Nam, Jaehyun;Lee, Juwon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.19 no.2
    • /
    • pp.101-107
    • /
    • 2014
  • This study is proposed the novel PPG sensor device and the signal processing method to replace the acceleration sensor that is used to reject motion artifacts contained in photoplethysmography(PPG). The proposed method is to reject motion artifacts by an adaptive filter based on the estimated motion artifact by using a blue LED light. To evaluate the performance of the proposed method experimentally, We did design a novel sensor consisted of blue/red LEDs and photo-sensor and implemented, and then rejected the motion artifacts by using an adaptive filter and the implemented sensor. In the results of the experiments, it is shown that the proposed sensor device and signal processing can reconstruct the PPG signal despite the occurrence of motion artifacts, and also that the SNR was 4.5 times of moving average filter. According to the experimental results, the proposed method can be applied to design a low-cost device.

A Study on LED Lighting Control according to Sleep Stage using PPG Sensor of Wearable Device

  • Song, Jeong Sang;Kim, Tae Yeun;Bae, Sang Hyun
    • Journal of Integrative Natural Science
    • /
    • v.12 no.1
    • /
    • pp.9-13
    • /
    • 2019
  • Recently, as the sleep disorder problem of modern people deepens, the interest towards quality of sleep is increasing. To increase the quality of modern people's sleep. This paper has suggested an LED lighting control system according to the sleep stage using PPG sensors of wearable devices. The pulse of the wrist radial artery was measured using a wearable device mounted with PPG sensor, which enables heart rate-measuring, and by using the point that heart rate lowers during stable sleep than non-sleeping, the LED lighting of indoors was controlled, which is the disturbing element when sleeping. For the performance evaluation, a 10-Fold cross analysis was conducted for performance evaluation, and a result of an average accuracy 87.02% was obtained as a result. Therefore, the LED lighting control system according to the sleep stage using a wearable device of this paper is expected to contribute to raise the quality of the user's life.

Design of Filter to Reject Motion Artifacts of PPG Signal by Using Two Photosensors

  • Lee, Ju-Won;Nam, Jae-Hyun
    • Journal of information and communication convergence engineering
    • /
    • v.10 no.1
    • /
    • pp.91-95
    • /
    • 2012
  • The photoplethysmography (PPG) signal measured from a mobile healthcare device contains various motion artifacts occurring from a patient’s movements. Recently, to reject the motion artifacts, the method of using an acceleration sensor was suggested, but such sensors are very expensive. Therefore, this study deals with a novel sensor device to replace the acceleration sensor, and evaluated the performance of the proposed sensor experimentally. In the results of the experiments, it is shown that the proposed sensor device can reconstruct the PPG signal despite the occurrence of motion artifacts, and also that the variation rate in heart rate analysis was 1.22%. According to the experimental results, the proposed method can be applied to design a low-cost device.

Study on Heart Rate Variability and PSD Analysis of PPG Data for Emotion Recognition (감정 인식을 위한 PPG 데이터의 심박변이도 및 PSD 분석)

  • Choi, Jin-young;Kim, Hyung-shin
    • Journal of Digital Contents Society
    • /
    • v.19 no.1
    • /
    • pp.103-112
    • /
    • 2018
  • In this paper, we propose a method of recognizing emotions using PPG sensor which measures blood flow according to emotion. From the existing PPG signal, we use a method of determining positive emotions and negative emotions in the frequency domain through PSD (Power Spectrum Density). Based on James R. Russell's two-dimensional prototype model, we classify emotions as joy, sadness, irritability, and calmness and examine their association with the magnitude of energy in the frequency domain. It is significant that this study used the same PPG sensor used in wearable devices to measure the top four kinds of emotions in the frequency domain through image experiments. Through the questionnaire, the accuracy, the immersion level according to the individual, the emotional change, and the biofeedback for the image were collected. The proposed method is expected to be various development such as commercial application service using PPG and mobile application prediction service by merging with context information of existing smart phone.

Development of portable PPG sensor based on smart phone (스마트폰 기반의 휴대용 PPG센서 개발)

  • Kim, Jung-han;Cho, Kyoung-lae;Kim, Sang-yoon;Kang, Sung-in;Bae, Sung-ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.05a
    • /
    • pp.1009-1011
    • /
    • 2013
  • 최근 U-헬스케어 서비스가 증가함에 따라 예방과 건강증진 등에 관심과 연구가 활발히 이루어지고 있다. 이러한 U-헬스케어에 사용되는 ECG, EMG, PPG EEG등이 스마트폰 기반의 휴대용 장비와 연동된 센서들의 연구 역시 활발히 진행 중이다. 일반적으로 PPG신호는 적외선센서를 이용하여 모세혈관의 혈중 헤모글로빈 농도 변화에 의한 맥파를 측정한다. PPG신호의 잡음을 제거하기 위해 필터를 사용하였다. 필터된 정보를 ADC하여 스마트폰으로 BlueTooth통신을 이용하여 전송한다. 최종적으로 스마트 디바이스에 PPG신호를 그린다. 제작결과 PPG아날로그 신호를 보는 것과 동일하게 스마트 디바이스에 그릴 수 있음을 보였다. 이후 PPG신호를 이용하여 혈관건강도 및 건강예방의 측정의 연구를 계속해서 한다.

  • PDF