• Title/Summary/Keyword: PPG (Photoplethysmography)

Search Result 103, Processing Time 0.022 seconds

The Motion Artifact Reduction using Periodic Moving Average Filter (주기적 이동평균필터를 이용한 동잡음 제거)

  • Lee, Jun-Yeon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.17 no.4
    • /
    • pp.75-82
    • /
    • 2012
  • The Photoplethysmogram is a similar periodic signal that synchronized to a heartbeat. In this paper, we propose a periodic moving average filter that use similarity of Photoplethysmogram. This filtering method has the average value of each samples through separating the cycle of PPG signal. If there are some motion artifacts in continuous PPG signal, disjoin the signal based on cycle. And then, we made these signals to have same cycle by coordinating the number of sample. After arrange these cycles in 2 dimension, we put the average value of each samples from starting till now. So, we can eliminate the motion artifacts without damaged PPG signal.

Assessment of stress in virtual reality environment using power spectral density ratio and second derivative of photoplethysmography (광 혈류 신호의 주파수 파워 특성과 이차 미분값을 이용한 가상환경의 스트레스 평가)

  • Y.H. Nam;Kim, H.T.;H.D. Ko;Park, K.S.
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2001.11a
    • /
    • pp.169-172
    • /
    • 2001
  • There are many people who suffer from simulation sickness when immersing in virtual reality. In this study, we analyzed two photoplethysmogram(PPG) parameters - a second derivative parameter and power spectral density ratios - in order to relate PPG parameters with simulation sickness. 36 young, healthy subjects were participated in the experiment, and each subject was equipped with a PPG electrode during his or her immersion. Simulation sickness section was defined as a 7 - second section which starts from the point where a subject reported simulation sickness, and normal section as a same-length section where no physical stimuli was presented to him or her. We compared the PPG parameters of the simulation sickness sections with the normal sections, - d/a ratio is believed to have lower value during vasodilation and higher value during vasoconstriction, however, we could not find much difference in the parameter between normal and simulation sickness sections. We also compared 1 to 10Hz power spectral density ratios in normal sections with in simulation sickness section, and found that 6 density ratios among them have different value. Therefore, the density ratios might be utilized as parameters to detect simulation sickness of subjects.

  • PDF

Study on Heart Rate Variability and PSD Analysis of PPG Data for Emotion Recognition (감정 인식을 위한 PPG 데이터의 심박변이도 및 PSD 분석)

  • Choi, Jin-young;Kim, Hyung-shin
    • Journal of Digital Contents Society
    • /
    • v.19 no.1
    • /
    • pp.103-112
    • /
    • 2018
  • In this paper, we propose a method of recognizing emotions using PPG sensor which measures blood flow according to emotion. From the existing PPG signal, we use a method of determining positive emotions and negative emotions in the frequency domain through PSD (Power Spectrum Density). Based on James R. Russell's two-dimensional prototype model, we classify emotions as joy, sadness, irritability, and calmness and examine their association with the magnitude of energy in the frequency domain. It is significant that this study used the same PPG sensor used in wearable devices to measure the top four kinds of emotions in the frequency domain through image experiments. Through the questionnaire, the accuracy, the immersion level according to the individual, the emotional change, and the biofeedback for the image were collected. The proposed method is expected to be various development such as commercial application service using PPG and mobile application prediction service by merging with context information of existing smart phone.

An Experimental Study of the Bioelectrical Signals and Subjective Response in Changing from Unpleasant to Pleasant Temperatures in a Learning Environment (학습환경에서 불쾌적온도에서 쾌적온도로의 변화시 생체신호 및 주관적 반응에 대한 실험적 연구)

  • Im, Gwanghyun;Kim, Jinhyun;Park, Chasik;Cho, Honghyun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.11
    • /
    • pp.596-602
    • /
    • 2015
  • In this study, experiments using bioelectronic signals and questionnaire surveys were carried out in learning conditions when temperatures changed from low- and high-uncomfortable to comfortable. As a result, the stress factor Photoplethysmography (PPG) decreased, while the Root Mean Square of Standard Deviation (RMSSD) of PPG increased when the indoor temperature was changed from low- or high-uncomfortable to comfortable. Additionally, the absolute power of the ${\alpha}$-wave in the brain increased. According to the analysis of the association between the questionnaire and bioelectronic signals, the standard deviation of the stress factor as measured by pulse was closely related to the result of the thermal sensation questionnaire. In addition, it was found that the concentration on studying improved under comfortable temperatures when compared to uncomfortable temperatures.

Heart Rate Measurement Combining Motion and Color Information

  • Lomaliza, Jean-Pierre;Park, Hanhoon;Moon, Kwang-Seok
    • Journal of Korea Multimedia Society
    • /
    • v.23 no.11
    • /
    • pp.1388-1395
    • /
    • 2020
  • Daily monitoring of the heart rate can facilitate detection of heart-related diseases in their early stages. Therefore, providing an easy-to-use and noninvasive heart rate monitoring system has been a very popular research topic in the field of healthcare. One of good candidate methods is to use commonly available cameras and extract information that can help to estimate heart rate from a human face. Generally, such information can be retrieved using two different approaches: photoplethysmography (PPG) and ballistocardiography (BCG). PPG exploits slight color changes caused by blood volume variations during heartbeats; thus, it tends to be vulnerable to unstable lighting conditions. BCG exploits subtle head motions caused by pumped blood travelling through the carotid artery during heartbeats; thus, it is vulnerable to the voluntary head movements that are not related to heartbeats. Nevertheless, most related works use either to estimate the heart rate. In this paper, we propose to combine two approaches to be robust to challenging conditions. Specifically, we explore possible ways to combine raw signals obtained from two approaches and verify that the proposed combination shows better accuracies under challenging conditions, such as voluntary head movements and ambient lighting changes.

A Vascular Characteristic Index of Blood Pressure Variation using the Pulse Wave Signal

  • Kim, Gi-Ryon;Jung, Dong-Keun;Ye, Soo-Young;Jeon, Gye-Rok
    • Transactions on Electrical and Electronic Materials
    • /
    • v.9 no.5
    • /
    • pp.213-219
    • /
    • 2008
  • Pulse waves continuously change with respect to the characteristics and status of the cardiovascular system and in relation to the blood pressure (BP) and the pulse wave velocity (PWV). Monitoring the vascular condition by analyzing the variations in pulse waveforms has been used to diagnose vascular disorders and in drug treatment of arteriosclerosis and peripheral circulatory obstruction. In this paper, we investigated the vascular characteristic index with regard to the BP and classified by pulse wave signals. The pressure pulse wave and photoplethysmography (PPG) were measured simultaneously while subjects exercised, producing changes in the BP, to analyze the variation in the vascular characteristic index. We investigated the correlation between the BP and vascular characteristic index with regard to the classification methods of the pulse wave. The reflection index (RI) and vascular stiffness index were correlated with the diastolic BP, but no correlation was found between these parameters and the systolic BP. These results suggest the possibility of estimating BP through simple measurements of pulse waves.

Real-time classification system of emotion image using physiological signal (생리신호에 의한 감성 이미지 실시간 분류 시스템 개발)

  • Lee, Jeong-Nyeon;Gwak, Dong-Min;Jeong, Bong-Cheon;Jeon, Gi-Hyeok;Hwang, Min-Cheol
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2009.11a
    • /
    • pp.232-235
    • /
    • 2009
  • 본 연구에서는 실시간으로 변화하는 사용자의 감성을 평가하여 각성 또는 이완으로 분류된 시선 정보 이미지를 저장하는 시스템을 구현하고자 한다. 사용자의 감성을 분류하기 위한 요소는 Larson과 Diner 가 정의한 2 차원 감성모델에서 각성, 이완 요소를 사용한다. 감성 상태를 분류하기 위하여 자율 신경계 중 착용과 휴대가 간편한 PPG 센서를 사용하며, PPG 를 분석하기 위한 변수로는 진폭의 양과 초당 Peak 의 빈도수를 사용한다. 머리에 고정할 수 있는 캠을 사용하여 사용자가 바라보는 시선 정보를 획득하고, 클라이언트 컴퓨터는 획득된 시선 정보를 UDP 통신을 사용해 서버 컴퓨터로 전송하는 시스템이다. 320(pixel)*240(pixel)*32(bit)인 영상 데이터를 1/30 로 압축하여 전송하며, 각성과 이완으로 분류되는 시점의 영상을 블록화하여 JPEG 이미지로 저장한다. 본 시스템은 실시간으로 변화되는 사용자의 감성 상태를 파악하여 이미지를 전송하고 서버 컴퓨터에 저장함으로써 당시 사용자가 느꼈던 감성들에 대해 피드백을 주고자 하는데 의의가 있다.

  • PDF

Design of Filter to Reject Motion Artifacts of PPG Signal by Using Two Photosensors

  • Lee, Ju-Won;Nam, Jae-Hyun
    • Journal of information and communication convergence engineering
    • /
    • v.10 no.1
    • /
    • pp.91-95
    • /
    • 2012
  • The photoplethysmography (PPG) signal measured from a mobile healthcare device contains various motion artifacts occurring from a patient’s movements. Recently, to reject the motion artifacts, the method of using an acceleration sensor was suggested, but such sensors are very expensive. Therefore, this study deals with a novel sensor device to replace the acceleration sensor, and evaluated the performance of the proposed sensor experimentally. In the results of the experiments, it is shown that the proposed sensor device can reconstruct the PPG signal despite the occurrence of motion artifacts, and also that the variation rate in heart rate analysis was 1.22%. According to the experimental results, the proposed method can be applied to design a low-cost device.

Comparison of blood flow ratio between normal and diabetic neuropathy group using photoplethysmograph (PPG를 이용한 정상인과 당뇨병 환자의 혈류량 비교)

  • Lee, Ju-Hyung;Kim, Sung-Woo;Kang, Eun-Seok;Kim, Deok-Won
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.77-79
    • /
    • 2007
  • The purpose of this study was to suggest a new detection method for early diagnosing diabetic neuropathic foot by obtaining a ratio of toe to figer blood flow using photoplethysmography(PPG). Nerve conduction velocity (NCV) has been routinely used for diagnosing neuropathic foot, but it applies strong electric stimulus to peripheries resulting in stress and pain. The blood flow ratio of diabetic neuropathy(0.96${\pm}$0.20) was significantly higher in comoarison to normal control group(0.46${\pm}$0.15, left : p<0.05, right : p<0.05) and non-neuropathy diabetic group(0.49${\pm}$0.21, left: p<0.05. right: p<0.05).

  • PDF

Real-time Heart Rate Measurement based on Photoplethysmography using Android Smartphone Camera

  • Hoan, Nguyen Viet;Park, Jin-Hyeok;Lee, Suk-Hwan;Kwon, Ki-Ryong
    • Journal of Korea Multimedia Society
    • /
    • v.20 no.2
    • /
    • pp.234-243
    • /
    • 2017
  • With the development of smartphone technologies enable photoplethysmogram (PPG) acquisition by camera and heart rate (HR) measurement. This papers presents improved algorithm to extract HR from PPG signal recorded by smartphone camera and to develop real-time PPG signal processing Android application. 400 video samples recorded by Samsung smartphone camera are imported as input data for further processing and evaluating algorithm on MATLAB. An optimized algorithm is developed and tested on Android platform with different kind of Samsung smartphones. To assess algorithm's performance, medical device Beurer BC08 is used as reference. According to related works, accuracy parameters includes 90% number of samples that has relative errors less than 5%, Person correlation (r) more than 0.9, and standard estimated error (SEE) less than 5 beats-per-minutes (bpm).