• Title/Summary/Keyword: PPG

Search Result 410, Processing Time 0.033 seconds

Feedback control for stable PPG measurement (안정된 광전용적맥파(PPG) 측정을 위한 피드백 제어 연구)

  • Lee, Hyun-Ki;Jho, Jung-Hyun;Sin, Woo-Sik;Yoo, Gil-Won
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.891-892
    • /
    • 2006
  • Photoplethsymogram (PPG) drifts due to the changes in respiration and blood perfusion as well as external light. This hinders a proper PPG measurement. We controlled DC drifts by controlling the signal ground of PPG signals. A microprocessor-based system successfully controlled DC drifts of PPG signals.

  • PDF

A Study on Selection of the Optimal Region of Interest for Smartphone Photoplethysmography (스마트폰의 PPG 신호를 위한 최적의 관심영역 선택에 대한 연구)

  • Shin, Suhae;Hong, Jieun;Moon, Chanki;Nam, Yunyoung
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2015.10a
    • /
    • pp.572-574
    • /
    • 2015
  • 최근 스마트폰 내장 카메라와 플래시를 사용하여 PPG 신호를 측정하고 생체정보를 측정하는 연구가 많이 진행되고 있다. 그러나 스마트폰 카메라를 사용하여 측정하는 PPG신호는 스마트폰 카메라와 플래시 위치에 따라 각 측정 영역의 신호의 세기가 다르다. 본 논문에서는 스마트폰 카메라와 플래시 위치에 따라 강한 PPG 신호를 가지는 ROI를 찾기 위해 비교, 분석하였다. ROI를 계산하기 위해 PPG 신호를 측정하고 ROI를 선정할 수 있는 스마트폰 애플리케이션을 개발하여 각 ROI의 PPG 신호의 편차를 계산하고 가장 최적의 영역을 실험을 통해 비교분석하였다.

A study on the Synthesis end Properties of Polyurethane Resin Based on PPG as a Glycol (폴리프로필렌글리콜을 글리콜 성분으로 하는 폴리우레탄 수지의 합성 및 물성에 관한 연구)

  • Yoo, Kil-Sang;Choi, Sang-Goo
    • Elastomers and Composites
    • /
    • v.35 no.3
    • /
    • pp.205-214
    • /
    • 2000
  • The polyurethane resin was prepared by the reaction of tolylenediisocyanate(TDI) and polypropyleneglycol(PPG). Physical properties of the resin were investigated experimentally. Charging catalyst before TDI-dropping induced the rapid increase of viscosity. On the other hand, charging catalyst after TDI-dropping resulted in mild stability without immoderate generation of heat on reaction. The use of phosphoric acid as catalyst led to low viscosity by restraining side-reaction such as forming of branch-chain, buret reaction and allopanate reaction, but it showed low cross-link density and slow drying. The curing speed was more influenced by structures of molecules rather than NCO/OH ratio. Including PPG 400 over 30 wt % showed excellent adhesive strength due to increase of crosslink density.

  • PDF

Comparison of vascular compliance between normal and replanted fingers using second derivative of photoplethysmogram (PPG 2차 미분을 이용한 정상과 재접합 손가락의 혈관 탄성도 비교)

  • Kim, Sung-Woo;Kim, Jin-Tae;Hong, Hyun-Ki;Kim, Soo-Chan;Kim, Deok-Won
    • Proceedings of the KIEE Conference
    • /
    • 2006.04a
    • /
    • pp.42-44
    • /
    • 2006
  • Up to the present, finger replantation patients have complained about various symptoms because of blood circulatory failure. Objective evaluation methods for the level of the blood circulatory failures in fingers were needed other than patient's subjective symptoms and complaints. Photoplethysmogram(PPG) measured from fingers is very useful for evaluation of vascular aging and sclerosis level since the PPG signal represents characteristics of peripheral vascular. Several researchers have reported that second derivative of the finger PPG waveform was useful to evaluate vascular compliance and developed various analysis methods for vascular compliance. However, vascular compliance study for finger replantation patient was never evaluated by using second derivative of PPG. Therefore, we aimed to objectively compare and to assess normal and replanted finger vascular compliance using the second derivative of PPG waveform in this study. The evaluated factors of second derivative of PPG are 'a', 'b', 'c', 'd', 'e' and b/a represents vascular compliance. Study found out that when vascular compliance is decreased, b/a is increased, the absolute value of b/a is decreased. For 43 finger replantation patients, the average vascular compliance of replanted finger is lower than the normal finger statistically(p=0.001). we suggested an objective evaluation of finger vascular compliance for finger replantation patients and effect of surgical operation.

  • PDF

Comparison of peripheral vascular compliance between normal and diabetic group using second derivative of photoplethysmogram (PPG 2차 미분을 이용한 정상인과 당뇨병 환자의 말초혈관 탄성도 비교)

  • Kim, Sung-Woo;Lee, Ju-Hyung;Kang, Eun-Seok;Kim, Soo-Chan;Kim, Deok-Won
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.67-69
    • /
    • 2007
  • Recently, the prevalence rate of diabetes in Korea has been increasing rapidly due to high growth of economy and changes in dietary lifestyle. Vascular complication is one of diabetic complications which have frequently occurred by obesity, hyperglycemia and impaired glucose metabolism. Photoplethysmogram(PPG) measured from finger and toe is very useful for evaluation of vascular aging and sclerosis level since the PPG signal represents characteristics of peripheral vascular. Several researchers have reported that second derivative of the finger PPG waveform was useful to evaluate vascular compliance and developed various analysis methods for vascular compliance. However, peripheral vascular compliance study for diabetic patient was never evaluated by using second derivative of PPG. Therefore, we aimed to objectively compare and to assess normal and diabetic group vascular compliance using the second derivative of PPG waveform in this study. The evaluated factors of second derivative of PPG are 'a', 'b', 'c', 'd', 'e' and b/a represents vascular compliance. Study found out that when vascular compliance is decreased, b/a is increased, the absolute value of b/a is decreased. The average vascular compliance of 50 diabetic patients with neuropathy is statistically lower than the normal group(p<0.05). We suggest an objective evaluation of peripheral vascular compliance for diabetic patients and prevention of vascular complication.

  • PDF

Effects of poly (ethylene glycol-propylene glycol) copolymer on hemostasis and osteogenesis in a rat calvarial defect model

  • Kim, Ha-Eun;Yoon, Hun-Young;Kim, Eun-Jin;Kim, Sun-Jong
    • Korean Journal of Veterinary Research
    • /
    • v.60 no.3
    • /
    • pp.145-153
    • /
    • 2020
  • This study aimed to evaluate the effects of a bioabsorbable bone hemostatic agent comprising poly (ethylene glycol-propylene glycol) copolymers (PEG-PPG) on hemostasis and osteogenesis. Bilateral 3 mm diameter calvarial defects were created in 99 male Sprague-Dawley rats. The defects were filled with PEG-PPG or bone wax. The defects of control group were left unfilled. Virtual autopsy was performed to evaluate bioabsorption. The calvaria were subjected to x-ray microtomography (microCT) and histological examination. Bone volume fraction (BV/TV) and bone mineral density (BMD) were measured using microCT; furthermore, white blood cell count and histological examination were performed. After application of PEG-PPG and bone wax, immediate hemostasis was achieved. Autopsy revealed that PEG-PPG disappeared within 48 h at the application site; in contrast, bone wax remained until 12 weeks. The PEG-PPG and control groups showed significantly more osteogenesis than the bone wax group with respect to BV/TV and BMD at 3, 6, and 12 weeks (p < 0.05). Histology revealed that the bone wax group exhibited little bone formation with inflammation. In contrast, PEG-PPG and control groups showed significantly more qualitative osteogenesis than the bone wax group (p < 0.01). In conclusion, PEG-PPG showed immediate hemostasis and was absorbed to allow progressive osteogenesis.

PPG Filtering Method for Respiration Measurement in U-Health Care System (U-Health Care 환경에서 호흡측정을 위한 PPG 최적필터기술)

  • Kim, Jong-Hwa;Whang, Min-Cheol;Nam, Ki-Chang
    • Journal of the Ergonomics Society of Korea
    • /
    • v.27 no.4
    • /
    • pp.95-101
    • /
    • 2008
  • This research is to develop PPG filtering method for respiration measurement in U-Health Care system. Respiration rate was determined by filtering PPG and analyzing its spectrum. Optimal filter of PPG has been selected to get respiration by testing 120 sets of experiment data using 700 filtering cases. As a result, 2nd order Bessel-filter that used band-pass cutoff frequency at 0.175~0.4Hz with second order was good at developing respiration signal. Respiration signal in time domain could be continuously analyzed by converting frequency domain using spectrum analysis. 24 seconds has been found to be optimal time duration of collecting PPG data for determining respiration. Therefore, this study was successful of getting not only heart activity but also respiration by only PPG. Minimal invasive measurement obtaining multi-bio information by one sensor can be expected to apply to U-Health Care and human computer interaction.

A Study on Pulse Measurement of Toe Using Photoplethysmography (광전용적맥파를 이용한 발가락에서의 맥박측정에 관환 연구)

  • Jung, In-Bok;Kim, Kyung-Ho
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2013.07a
    • /
    • pp.353-354
    • /
    • 2013
  • 본 논문에서는 기존의 손에서 측정하는 PPG를 발가락에서 측정하여 지속적인 무자각적 측정이 가능함을 제안한다. 발가락에서의 측정은 손이 자유로워져 일상 업무에 영향을 끼치지 않으면서 고정하기 유용하기 때문에 보다 상황에 맞는 정확한 파형 검출이 가능하다. 따라서 본 논문에서는 발가락에서의 측정 가능성을 확인한 후 소형 device 제작 및 실험을 통해 손과 발에서 PPG를 측정, 비교하여 발가락에서도 PPG 파형 검출이 가능함을 보인다.

  • PDF

A study on the analysis ofPPG signal for individual verification (개인 인증을 위한 PPG 신호 분석에 관한 연구)

  • Kim, Sheen-Ja;Lee, Young-Woo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.10a
    • /
    • pp.438-440
    • /
    • 2009
  • 사람의 심박동은 심장 상태와 구조, 나이 등의 여러 요소에 의하여 고유한 특성을 갖고, 이러한 특성을 이용하여 개인 인증에 심박동을 적용할 수 있다. 본 논문에서는 기존의 심전도(ECG, electrocardiogram) 방법을 대신하여 빛을 이용한 광전용적맥파(PPG, Photo Plethysmogram)를 측정, 신호를 분석하였다.

  • PDF

Comparison of peripheral vascular compliance between normal and diabetic groups using the second derivative of photoplethysmogram (PPG 2차 미분을 이용한 정상인과 당뇨병 환자의 말초혈관 탄성도 비교)

  • Kim, Sung-Woo;Lee, Ju-Hyung;Nam, Ki-Chang;Kim, Su-Chan;Cha, Eun-Jong;Kim, Deok-Won
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.4 s.316
    • /
    • pp.15-20
    • /
    • 2007
  • Recently the prevalence rate of diabetes in Korea has been increasing rapidly due to high growth of economy and changes in dietary lifestyle. Vascular complication is one of diabetic complications which have frequently occurred by obesity, hyperglycemia and impaired glucose metabolism. Photoplethysmogram(PPG) measured from finger and toe is very useful for evaluation of vascular aging and sclerosis level since the PPG signal represents characteristics of peripheral vascular Several researchers have reported that second derivative of the finger PPG waveform was useful to evaluate vascular compliance and developed various analysis methods for vascular compliance. However, peripheral vascular compliance study for diabetic patient was never evaluated by using second derivative of PPG. Therefore, we aimed to objectively compare and to assess normal(n=850) and diabetic(n=50) groups vascular compliance using the second derivative of PPG waveform in this study. The evaluated factors of the second derivative of PPG are 'a', 'b', 'c', 'd', 'e' and b/a rapresents vascular compliance. This study found out that when vascular compliance is decreased, the absolute value of b/a is decreased. The average vascular compliance of 50 diabetic patients with neuropathy, $-1.09{\pm}0.14$ is statistically lower than the normal group, $-0.81{\pm}0.09$ (p<0.05). In conclusion, we suggest an objective evaluation of peripheral vascular compliance for diabetic patients and prevention of vascular complication.