• Title/Summary/Keyword: POE

Search Result 250, Processing Time 0.022 seconds

A Case Study of Post-Occupancy Evaluation of Home Automation System by Digital Home Residents - Focused on H Highrise Apartment - (디지털 홈 거주자의 홈오토메이션 시스템에 대한 거주 후 평가 사례 연구 - H 초고층 아파트 거주자를 중심으로 -)

  • Kwon, Oh-Jung
    • Journal of the Korean housing association
    • /
    • v.19 no.1
    • /
    • pp.17-27
    • /
    • 2008
  • Recently, newly built apartments in Korea are provided various home automation (HA) systems based on information technology(IT) for residents' safer, healthier and more convenient living. However, the residents in these digital apartments are often not able to use the home automation systems effectively because of lack of their IT knowledge, attitude, or education. However, there are few researches have been done to find out the HA systems' real problems with regard to residents' aspects who use those systems everyday. The purpose of this study was to find out residents' current uses, satisfaction level and existing problems of HA systems by residents' POE. The findings of this study will give useful information to digital home construction companies to provide user-friendly digital home services for increasing users' satisfaction. One distinctive apartment equipped with home automation systems located in Seoul was selected for in-depth personal interview. The researcher developed a survey instrument and collected the data from 58 residents in January, 2007 who had been living there for more than a year. The results of the study found that critical problems were existed in several systems and they caused a lot of dissatisfaction from the residents. Also, some residents do not use several systems although they need to use them due to the burden of maintenance fee. Further detail findings and suggestions of this study were discussed.

Effect of Refrigeration Oil on the Condensation Heat Transfer for R-22 and R-407C Refrigerations in Microfin Tube with a U-bend

  • Cho, Keum-Nam;Tae, Sang-Jin
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.9 no.2
    • /
    • pp.85-93
    • /
    • 2001
  • The present study experimentally investigated the effect of refrigeration oil on the condensation heat transfer for R-22 and R-407C in a microfin tube with a U-bend. Mineral oil and POE oil were used for R-22 and R-407C respectively. Experimental parameters were an oil concentration from 0 to 5%, a mass flux from 100 to 400 $kg/m^2s$ and an inlet quality from 0.5 to 0.9. The enhancement factors for both R-22 and R-407C refrigerants at the first straight section decreased continuously as the oil concentration increased. The decreased rapidly as the mass flux decreased and the inlet quality increased. The heat transfer coefficients in the U-bend showed the maximum at the 90$^{\circ}$position. the heat transfer coefficients at the second straight section within the dimensionless length of 48 were larger by a maximum of 33% than the average heat transfer coefficient at the first straight section.

  • PDF

An Experimental Study on Vapor-Liquid Equilibria of $CO_2$/Oil Mixtures in the Range of Evaporator Working Pressure (증발기 작동 압력 범위에서 $CO_2$/오일 혼합물의 기상-액상 평형 실험)

  • Lee, Chi-Seok;Lee, Kyoung-Youl;Kang, Byung-Ha;Park, Kyoung-Kuhn
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.380-385
    • /
    • 2005
  • An experimental apparatus was constructed to obtain vapor-liquid equilibrium data for $CO_2$/oil mixtures using mass analysis method with sample cylinder. Lubricants employed were POE(Polyol Ester) oil and PAG(Poly Alkylene Glycol) oil. The phase equilibria of $CO_2$/oil mixtures formed in high pressure equilibrium cell are observed through sight glasses at the opposite ends. Data were measured over the temperature range from -10 to $10^{\circ}C$ with $5^{\circ}C$ intervals under pressures up to 14 MPa. Mole fractions were calculated for $CO_2$/oil and $CO_2$/PAAG, respectively and were compared with each other.

  • PDF

Properties of Microemulsion Containing Quaternary Ammonium Salt as Polishing Wax (광택용 왁스로서 4차 암모늄염을 함유한 마이크로에멀젼의 특성)

  • Lee, Jang-Weon;Kim, Myung-Soo;Jeong, Noh-Hee
    • Journal of the Korean Applied Science and Technology
    • /
    • v.21 no.4
    • /
    • pp.335-344
    • /
    • 2004
  • In this work, the properties as polishing wax for automobile of O/W type microemulsion containing wax, liquid paraffine and quaternaryammonium salt was investigated. The microemulsions were prepared at $96{\sim}97^{\circ}C$ by the phase inversion method, and polyoxyethylene(20) sorbitan monooleate (POE(20)SMO) and distearyl dimethyl ammonium chloride(D.D.A.C) as the emulsifiers were used. The mean particle size of the rnicroemulsions was about 7${\pm}$0.5nm and as the properties of polishing wax, gloss increased degree, water resistant gloss degree, initial and final contact angle after water resistance were tested. The result was that the value of water resistantance and contact angle were decreased with increasing amount of POE(20)SMO and D.D.A.C., while the gloss degree values did not affected. And the rnicroemulsion blended with mono ethylene glycol(MEG) of 5${\sim}$15wt% showed smaller particle size and more stable particle size distribution than without MEG. Finally, this microemulsion showed more excellent values of gloss degree, the water resistant gloss degree and contact angle, than two kinds of commercial polishing wax for automobile.

Management and Operation of Apartment Community Facilities and Post Occupancy Evaluation - Focused on the R Apartments Complex in Daegu - (아파트 단지 내 커뮤니티 시설의 운영 실태와 거주 후 평가 - 전문관리자 운영의 대구 R아파트 단지를 중심으로-)

  • Kang, Soon-Joo
    • Journal of the Korean housing association
    • /
    • v.21 no.4
    • /
    • pp.111-120
    • /
    • 2010
  • This study examines the effectiveness of a new community facility operation and management system that were implemented by one of the major construction companies. This system was an unprecedented approach in a sense that it provided not only necessary facilities but also a specialized management staff, an operational manual, and a subsidy for various programs. According to POE conducted among the residents, it can be concluded that the residents' satisfaction will be increased under the following conditions; 1) when a program manual associated with the community facility is provided, 2) when there is a professional staff who can coordinate various programs effectively, 3) when the facilities are well designed in accordance with the program requirements, 4) when the users adhere to regulations and management standards, 5) when all three components- i.e. facility, people and programs- are well coordinated, and 6) when affordable user fees are charged. This research assures that professional management staff and well-planned management system play a significant role in the enhancement of the residents' satisfaction as well as vitalizations of the community.

Effective Strategy for Precise Orbital and Geodetic Parameter Estimation Using SLR Observations for ILRS AAC

  • Kim, Young-Rok;Oh, Jay;Park, Sang-Young;Park, Chandeok;Park, Eun-Seo;Lim, Hyung-Chul
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.2
    • /
    • pp.159.2-159.2
    • /
    • 2012
  • In this study, we propose an effective strategy for precise orbital and geodetic parameter estimation using SLR (Satellite Laser Ranging) observations for ILRS AAC (Associate Analysis Center). The NASA/GSFC GEODYN II software and SLR normal point observations of LAGEOS-1, LAGEOS-2, ETALON-1, and ETALON-2 are utilized for precise orbital and geodetic parameter estimation. Weekly-based precise orbit determination strategy is applied to process SLR observations, and Precise Orbit Ephemeris (POE), TRF (Terrestrial Reference Frame), and EOPs (Earth Orientation Parameters) are obtained as products of ILRS AAC. For improved estimation results, selection strategies of dynamic and measurement models are experimently figured out and configurations of various estimation parameters are also carefully chosen. The results of orbit accuracy assessment of POE and precision analysis of TRF/EOPs for each case are compared with those of existing results. Finally, we find an appropriate strategy for precise orbital and geodetic parameter estimation using SLR observations for ILRS AAC.

  • PDF

Effect of Refrigeration Oil on the Condensation Heat Transfer for Alternative Refrigerant in Microfin Tube with a U-bend (마이크로핀관 곡관부내 대체 냉매의 응축 열전달에 미치는 냉동기유의 영향)

  • 태상진;조금남
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.6
    • /
    • pp.541-549
    • /
    • 2000
  • The present study experimentally investigated the effect of refrigeration oil on the condensation heat transfer for R-407C and R-22 in a microfin tube with a U-bend. POE oil ($74.1\;\textrm{mm}^2/s,\;40^{\circ}C$,) and mineral oil $62.5\;\textrm{mm}^2/s,\;40^{\circ}C$,) were used for R-407C and R-22 respectively Experimental parameters were an oil concentration from 0 to 5%, a mass flux from 100 to $400kg/m^{2}s sand an inlet quality from 0.5 to 0.9. The enhancement factors for both R-22 and R-407C refrigerants at the first straight section decreased continuously as the oil concentration increased. They decreased rapidly as the mass flux decreased and the inlet quality increased. The heat transfer coefficients in the U-bend showed the maximum at the $90^{\circ}$/TEX> position. The heat transfer coefficients at the second straight section within the dimensionless length of 48 were larger by a maximum of 33% than the average heat transfer coefficient at the first straight section.

  • PDF

Isolation of High Yielding Alkaline Protease Mutants of Vibrio metschnikovii Strain RH530 and Detergency Properties of Enzyme

  • Chung, So-Sun;Shin, Yong-Uk;Kim, Hee-Jin;Jin, Ghee-Hong;Rho, Hyune-Mo;Lee, Hyune-Hwan
    • Journal of Microbiology and Biotechnology
    • /
    • v.10 no.3
    • /
    • pp.349-354
    • /
    • 2000
  • Abstract A facultative alkalophilic gram-negative Vibrio metschnikovii strain RH530, isolated from the wastewater, produced several alkaline proteases (VAP) including six alkaline serine proteases and a metalloprotease. From this strain, high yielding YAP mutants were isolated by NTG treatment. The isolated mutant KS1 showed nine times more activity than the wild-type after optimization of the culture media. The production was regulated by catabolite repression when glucose was added to the medium. The effects of several organic nitrogen sources on the production of the YAP were investigated to avoid catabolite repression. The combination of 4% wheat gluten meal (WGM), 1.5% cotton seed flour (eSF), and 5% soybean meal (SBM) resulted in the best production when supplemented with 1% NaCl. The YAP showed a resistance to surfactants such as $sodium-{\alpha}-olefin$ sulfonate (AOS), polyoxy ethylene oxide (POE), and sodium dodecyl sulfate (SDS), yet not to linear alkylbenzene sulfonate (LAS). However, the activity of the YAP was restored completely when incubated with LAS in the presence of POE or $Na_2SO_4$. The YAP was stable in a liquid laundry detergent containing 6.6% SLES (sodium lauryl ether sulfate), 6.6% LAS, 19.8% POE, and stabilizing agents for more than two weeks at $40^{\circ}C$, but the stability was sharply decreased even after 1 day when incubated at $60^{\circ}C$. A washing performance test with the YAP exhibited it to be a good washing power by showing 51 % and 60% activity at $25^{\circ}C{\;}and{\;}40^{\circ}C$, respectively, thereby indicating that the YAP also has a good detergency at a low temperature. All the results suggest that the YAP produced from the mutant strain KSI has suitable properties for use in laundry detergents.rgents.

  • PDF

A Study on Management Condition and Improvement of Artificial Greens in GBCS-Certified Apartments through the Post Occupancy Evaluation (POE를 통한 친환경건축물 인증 공동주택 인공환경 녹화 관리 실태 및 개선방안 연구)

  • Kim, Bo-Ram;Ahn, Tong-Mahn
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.40 no.6
    • /
    • pp.1-12
    • /
    • 2012
  • This study aims to suggest ways to improve sustainability on housing complexes. This study sampled eight housing projects in Seoul and GyeongGi-Do in Korea, which were completed in June 2007 and June 2008. Then, are retention and maintenance on "constructed greens for ecological environment" including "green structures substitutes retaining walls", "green roofs", and "green walls." Study methods are field investigations of the sampled sites, and Post Occupancy Analysis. Major findings were; 1) "constructed greens" are not well retained in more sites and and this implies the GBCS(Green Building Certification System) does not meet its objectives well, 2) User showed lower user satisfaction to "constructed greens". User satisfaction concerning "green structures substitute retaining walls" was higher than the satisfaction on the other constructed green type. Satisfaction Assessment Criteria lower 1han average were "level of quality", "meet the design objectives", "vegetation management status", "vegetation maintenance". 3) User satisfaction was strongly correlated on the level of quality factor of "constructed green". In addition, tue other factors are the significant correlations between the satisfactions. The present GBCS has inadequate assessment standards for maintenance, which lead to lower the entire satisfaction. Therefore, periodic recertification system, education and information providing for the managing personals, and incentives for good maintenance or disincentive for poor maintenance of the "constructed greens" are suggested to improve the GBCS.

Analysis on PD Pulse Distribution by Defects Depending on SF6 Pressure (SF6 압력에 따른 결함별 부분 방전 펄스의 분포 분석)

  • Kim, Sun-Jae;Jo, Hyang-Eun;Jeong, Gi-Woo;Kil, Gyung-Suk;Kim, Sung-Wook
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.1
    • /
    • pp.40-45
    • /
    • 2015
  • Electrode systems: a protrusion on conductor (POC), a protrusion on enclosure (POE), a crack in epoxy plate and a free particle (FP) were fabricated to simulate insulation defects in a gas insulated switchgear (GIS). $SF_6$ gas was filled in the electrode systems by 3 bar and/or 5 bar, respectively. Partial discharge (PD) pulses were detected through a $50{\Omega}$ non-inductive resistor. A calibration test was carried out according to IEC 60270, and the sensitivity was 0.25 pC/mV. PD pulses were distributed in the phase of $50^{\circ}{\sim}135^{\circ}$ and over 95% of them existed in the phase of $55^{\circ}{\sim}120^{\circ}$ for the POC. PD pulses were distributed in the phase of $230^{\circ}{\sim}310^{\circ}$ and over 90% of them existed in phase of $220^{\circ}{\sim}300^{\circ}$ for the POE. PD pulses occurred in the phase of $40^{\circ}{\sim}60^{\circ}$ and $220^{\circ}{\sim}300^{\circ}$ for the crack, and pulse counts were 25% higher in negative polarity than in positive polarity. PD pulses were distributed in every phase unlike to other three electrode systems and the peak magnitude was measured at $118^{\circ}$ and $260^{\circ}$ for the FP. As described above, PD pulses were observed in positive polarity for the POC, in negative one for the POE, in both one for the crack and the FP. In conclusion, it is expected that the identification rate of defect type can be improved by considering the polarity ratio of PD pulses on the PRPDA method.