• 제목/요약/키워드: PMV 환경

검색결과 85건 처리시간 0.045초

여름철 사무실내 온열환경 특성 및 쾌적성 평가 (Characteristics of Thermal Environments and Evaluation of Thermal Comfort in Office Building in Summer)

  • 이철희;배귀남;최항철;이춘식
    • 설비공학논문집
    • /
    • 제6권3호
    • /
    • pp.206-217
    • /
    • 1994
  • In this study, indoor thermal parameters were measured to investigate the characteristics of thermal environments and 212 occupants were questioned to evaluate Korean thermal comfort in office building in summer. Thermal and comfort sensations were estimated using PMV(Predicted Mean Vote) and ET* (New Effective Temperature) which are most widely used nowadays. Comparing this experimental result with international standards and that of other research, Korean thermal responses were discussed. It was found that TSV(Thermal Sensation Vote) is more sensitive than PMV to the variation of temperature and that the measured percentage of dissatisfied is higher than PPD(Predicted Percentage of Dissatisfied) in real office building environments. By regression analysis, the following regression equation has been obtained: TSV=0.461ET*-11.808 and neutral temperature is $25.6^{\circ}C$ in this case. Thermal comfort range based on 80% satisfaction is also $24.0{\sim}26.8^{\circ}C$, which is about $1^{\circ}C$ higher than that of ANSI/ASHRAE Standard.

  • PDF

천정형 정풍량 시스템에어컨의 적용높이에 따른 실내온열환경 특성 (Comparison of the PMV and ADPI according to Adapted Height of Ceiling-type System Air-conditioner in Large space)

  • 성상철;김혁순;진심원;오명도
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.590-595
    • /
    • 2009
  • PMV and ADPI were numerically investigated in a large space of various ceiling height with air-conditioning systems of two type. The numerical results showed that it is small that the growth of cooling load according to ceiling height rise in a large space without windows. In case of system air-conditioner of duct type embedded in the ceiling, the air mixing effect in indoor is superior to a case installed 4way cassette type in it. For controling thermal comfort at indoor, a system air-conditioner of duct type embedded in the ceiling is little influenced according to ceiling height rise in a large space considered.

  • PDF

한국인의 온열쾌적감에 관한 연구 ( Part I : 겨울철 체감실험 결과 ) (Experimental Study on Thermal Comfort Sensation of Korean ( Part I : Analysis of Subjective Judgement in Winter Experiment ))

  • 금종수;최광환;김동규;주익성;김종열;박희욱;이구형;최호선
    • 감성과학
    • /
    • 제1권1호
    • /
    • pp.199-211
    • /
    • 1998
  • 본 연구의 목적은 한국인을 대상으로 겨울철 체감실험을 통해 SET*(PMV)와 상관관계를 규명하고, ASHRAE Standard 55-74의 쾌적영역과 한국인의 쾌적영역을 비교 검토하는 것이다. 실험에 참가한 각 피험자는 동일한 유니폼을 착용한 체 의자에 앉아 환경시험실에서 2시간 체재하였다. 피험자의 평균피부온도는 신체 3군데에서 측정한 피부온도 값을 이용하였고, 전신온냉감 및 쾌불쾌감 신고는 매 15분 간격으로 측정하였다. 전신온냉감 신고 스케일은 -3= cold, -2=cool, -1=slight cool, o=neutral, +1= Slightly warm, +2=warm, +3=hot 이며, 쾌불쾌감 신고스케일은 0=comfortable, +1=slightly comfortable, +2=uncomfortable, +3=very uncomfortable이다. 겨울철 체감실험을 통해 아래의 결론을 얻었다. 1)전신온냉감이 중립이 될때 청년층의 SET*는 25.5$^{\circ}C$이며, 고령자의 중립온도는 27$^{\circ}C$이었다. 고령자는 청년에 비해 $1.5^{\circ}C$(SET*) 정도 고온을 선호하였다. 2)청년층의 쾌적영역은 24.2-26.8$^{\circ}C$(SET*)이며, 고령자의 쾌적영역은 25.7-28.2$^{\circ}C$이었다. 이러한 쾌적영역은 ASHRAE의 쾌적영역보다 고온지향적임을 알 수 있었다.

  • PDF

겨울철 가습 및 환기에 따른 교실내 쾌적환경 분석 (Analysis of Comfortable Environment in the Classroom with Humidification and Ventilation in Winter)

  • 성내리;정성일;이재근;박종훈
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.1213-1219
    • /
    • 2008
  • This experimental study was to analyze thermal comfort and indoor air quality(IAQ) with ventilation and humidification in the classroom when system air conditioner was operated. The thermal comfort was estimated by the PMV index and the concentration of $CO_2$ and total suspended particle(TSP) were measured and compared with ventilation and humidification. As a result, the class room temperature distribution was $2{\sim}5^{\circ}C$ low during operating ventilation system and humidification. At 60% RH, PMV values of measuring points were ranged from +0.5 to -0.5 indicating optimal the range of thermal comfort. The average concentration of $CO_2$ gas and TSP were reduced 645 ppm, 0.17 mg/$m^3$ respectively, during operating the ventilation system. From the results, to maintain comfortable environment in the heated classroom, the ventilation and humidification were needed in winter season.

  • PDF

거리협곡 벽면녹화 조성유형에 따른 미기상 변화 및 열환경 평가 (A Study on Verifying the Effect of Thermal Environment Control of Street Canyons based on Application of Green Wall System)

  • 김정호;최원준;윤용한
    • 한국환경과학회지
    • /
    • 제25권2호
    • /
    • pp.311-322
    • /
    • 2016
  • This study reduced and built Street Canyons created by skyscrapers in order to verify effect of Street Canyons by green wall within the city centre and analysed influence factors on temperature reduction according to applicative types of green wall in the lab. Applicative types were divided into three types such as non- greening type(Case A), one-side greening type(Case B), both side greening type(Case C). The result of analysis of each types showed that average temperature of Case B and Case C is respectively $1.0^{\circ}C$ and $1.7^{\circ}C$ lower than Case A. The result of analysis of WBGT was that the highest temperature was given by Case A($40.2^{\circ}C$) and second one was from Case B($39.8^{\circ}C$) and third one was from ($39.1^{\circ}C$) and in UTCI Case A records the highest temperature of $34.7^{\circ}C$ and Case B provided the second highest temperature of $33.9^{\circ}C$ and Case B gave the lowest temperature of $32.7^{\circ}C$. In PMV the highest temperature of 2.65 was from Case B and second one of 2.61 was from Case A and third one of 2.54 was from Case C. Duncan analysis of each types based on solar radiation and thermal comfort generated that there was analytical significance between Case A and Case B and Case B in terms of each types of average temperature reduction. The significance of thermal comfort in WBGT, MRT, PMV showed non-significance but, In UTCI it was analysed that there was significance between Case C and Case A.

식생기반 바이오필터의 미세먼지, 이산화탄소 개선효과와 실내쾌적지수 분석 (Particulate Matter and CO2 Improvement Effects by Vegetation-based Bio-filters and the Indoor Comfort Index Analysis)

  • 김태한;최부헌;최나현;장은숙
    • 한국환경농학회지
    • /
    • 제37권4호
    • /
    • pp.268-276
    • /
    • 2018
  • 본 연구는 일반인에게 안전한 실내공기질 개선수단으로 인식되는 공기정화식물의 효율적 적용을 위해 실내공조에 요구되는 총풍량 확보가 가능한 식생기반 바이오필터 시스템을 제안하고자 했다. 시스템의 정량적 성능평가는 강의실형태의 실험실 체적 $332.73m^3$ 내 16명의 재실자 조건에서 목업단위 시스템의 공조 성능, 실내공기질 및 쾌적지표 개선효과에 대한 시계열 분석으로 진행되었다. 우선, 시스템 구동을 통해 총 $1,411.22m^3/h$의 유출 총풍량을 확보하여, 4.24 ACH의 환기율을 제공할 수 있었다. 실내온도는 $1.6^{\circ}C$, 흑구온도는 $1.0^{\circ}C$ 감소가 확인되었으며, 상대습도는 24.4% 상승한 최대 82.0%까지 증가하였다. 상대습도 급증에 따른 쾌적도 감소현상은 송풍기 구동에 따라 발생되는 실내기류로 상쇄되는 것으로 판단된다. 또한, 시스템 가동에 따른 공기질 개선지표 중 $PM_{10}$은 39.5% 감소한 평균 $22.11{\mu}g/m^3$을 기록하였다. 반면, $CO_2$는 최대 1,329 ppm까지 지속적으로 농도가 상승했는데, 이는 광도조건이 광보상점을 만족하지 못해 적용 식물과 재실자에서 방출되는 $CO_2$가 처리되지 못한 것으로 해석된다. 실내쾌적지표의 경우 PMV는 평균 83.6 % 감소된 -0.082, PPD는 평균 47.0% 감소된 5.41%에 수렴하여 식생기반 바이오필터 구동에 의해 높은 쾌적범위의 실내공간조성이 가능한 것으로 판단되었다. 본 연구의 한계는 소수 참여인원과 단기간 실험으로 인하여 시스템의 성능 규명이 제한적인 부분이었으며, 보다 장기간의 실험을 통해 바이오필터에 도입된 식생의 생육상태에 따른 압력손실 변화, 미세먼지 저감에 대한 구체적인 메커니즘 규명 등의 후속연구가 진행되어야 할 것이다.

냉방시 천장분출 및 바닥분출 공조방식에 따른 열환경 평가실험 (Experimental Analysis of Thermal Comfort for Ceiling and Floor Supply Air-conditioning Systems)

  • 조용;권혁승;김성현;김영일
    • 한국감성과학회:학술대회논문집
    • /
    • 한국감성과학회 1998년도 추계학술발표 논문집
    • /
    • pp.133-139
    • /
    • 1998
  • 생활수준이 향상됨에 따라 인간의 감성을 생활환경에 적용하려는 연구가 진행되고 있다. 감성에 영향을 미치는 요인은 다양하나 이 중에서도 열환경은 인간에게 미치는 정도가 어떠한 요인보다도 큰 것으로 알려져 있다. 열환경이라 함은 온도, 습도, 기류, 복사열을 말하며 이 요소들은 인간의 감성과 밀접한 관련을 지닌다. 실내의 열환경은 공조방식에 따라 크게 달라지며 본 연구에서는 천장분출과 바닥분출 공조방식의 비교실험을 수행하여 실내의 열환경을 평가한다. 두 공조방식을 여름철 사무실 공간을 모사하는 열환경챔버에 적용하여 실내의 온도, 기류, 복사온도, PMV의 분포를 측정한다. 실험 결과 바닥분출 공조방식이 쾌적성과 에너지 절약면에서 우수함을 알 수 있었다.

  • PDF

냉방시 천장분출 및 바닥분출 공조방식에 따른 열환경 평가 (Analysis of Thermal Comfort for Ceiling and Floor Supply Air-conditioning System)

  • 이기섭;김영일
    • 한국감성과학회:학술대회논문집
    • /
    • 한국감성과학회 1998년도 춘계학술발표 논문집
    • /
    • pp.249-254
    • /
    • 1998
  • 생활수준이 향상됨에 따라 인간의 감성을 생활환경에 적용하려는 연구가 진행되고 있다. 감성에 영향을 미치는 요인은 다양하나 이 중에서도 열환경은 인간에게 미치는 정도가 어떠한 요인보다도 큰 것으로 알려져있다. 열환경이라 함은 온도, 습도, 기류, 복사열을 말하며 이 요소들은 인간의 감성과 밀접한 관련을 지닌다. 실내의 열환경은 공조방식에 따라 크게 달라지며 본 연구에서는 천장분출과 바닥분출 공조방식에 따른 실내의 열환경을 평가한다. 두 공조방식을 여름철 사무실 공간에 적용하여 실내의 온도, 기류, 복사온도, PMV의 분포를 수치해석적으로 계산한다. 해석 결과 바닥분출 공조방식이 쾌적성과 에너지 절약면에서 우수함을 알 수 있었다.

  • PDF

실내 환경의 쾌적도 측정시스템 개발 (Development of Comfort Sensing System for Human Environment)

  • 강정호;이재용;김우현
    • 한국산업융합학회 논문집
    • /
    • 제9권4호
    • /
    • pp.317-321
    • /
    • 2006
  • 본 연구는 웰빙 환경 조성에 적합한 습도센서, 온도센서와 기류센서를 이용한 쾌적도 측정시스템에 관한 것이다. 이 측정시스템이 나타내는 쾌적도는 기류와 온도에 민감하게 나타났다. 시스템을 위한 온도와 습도 일체형 센서와 기류센서를 설계 및 제작하고, 마이크로 컨트롤러에서 센서 신호를 측정하여 ISO7730에서 나타내는 예상온열 감지수(PMV)와 쾌적감 지수(CSV)를 계산하고, 각각의 계산 값을 LCD에 표시하도록 하였다. 인위의 환경에서 실험한 결과, 본 시스템이 공기조화시스템, 자동차 기류조정시스템, 가정과 사무실 병원 등의 많은 분야에 적용이 될 수 있음을 알 수 있었다.

  • PDF

대공간의 실내온열환경 실측 및 분석 (The Field Measurement and Analysis of Indoor Thermal Environment in Large Enclosures)

  • 채문병;양정훈;최동호;석호태
    • 한국공간구조학회논문집
    • /
    • 제8권1호
    • /
    • pp.77-88
    • /
    • 2008
  • 본 연구에서는 대공간을 동계 및 하계로 구분하여 실내온열환경의 변화를 실측하고 냉 난방조건과 관련하여 대공간에서 형성되는 실내온열환경의 특성을 파악하는 것을 목적으로 하여, 대공간의 수직 및 수평온도분포, 객석온도분포, 실내표면온도분포, 실내온열쾌적성 등의 실내온열환경을 검토하였다.

  • PDF