How to Prepare the Manuscript for Submission to the Proceedings of KSPE Conference (비예혼합화염과 예혼합화염의 속도 섭동에 따른 응답 특성)

  • Ahn, Myunggeun;Kim, Taesung;Yoon, Youngbin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.612-616
    • /
    • 2017
  • An experimental study investigates the flame response characteristics of non-premixed flame and premixed flame. Air was used as the oxidant. Hydrogen($H_2$)/methane($CH_4$) was used as the fuel, and the mixing ratio of the fuel was 50/50%. Flame response characteristics for various velocity perturbations were experimented. The flame images was acquired using the OH fluorescence measurement and the images were digitized using MatLab code. The results of the premixed flame show that flame perturbation increases as the oscillation amplitude increases. As the amplitude increases, the gain value of the flame transfer function is observed to be a linear behavior. The flame length of a nonpremixed flame decreases as the oscillation amplitude increases. Also, it was confirmed that the gain value according to the amplitude behaves nonlinearly.

  • PDF

Efficient design of a ∅2×2 inch NaI(Tl) scintillation detector coupled with a SiPM in an aquatic environment

  • Kim, Junhyeok;Park, Kyeongjin;Hwang, Jisung;Kim, Hojik;Kim, Jinhwan;Kim, Hyunduk;Jung, Sung-Hee;Kim, Youngsug;Cho, Gyuseong
    • Nuclear Engineering and Technology
    • /
    • v.51 no.4
    • /
    • pp.1091-1097
    • /
    • 2019
  • After the Fukushima accident in 2011, there has been increased public concern about radioactive contamination of water resources through fallout in neighboring countries. However, there is still no available initial response system that can promptly detect radionuclides. The purpose of this research is to develop the most efficient gamma spectrometer to monitor radionuclides in an aquatic environment. We chose a thallium-doped sodium iodide (NaI(Tl)) scintillator readout with a silicon photo multiplier (SiPM) due to its compactness and low operating voltage. Three types of a scintillation detector were tested. One was composed of a scintillator and a photomultiplier tube (PMT) as a reference; another system consisted of a scintillator and an array of SiPMs with a light guide; and the other was a scintillator directly coupled with an array of SiPMs. Among the SiPM-based detectors, the direct coupling system showed the best energy resolution at all energy peaks. It achieved 9.76% energy resolution for a 662 keV gamma ray. Through additional experiments and a simulation, we proved that the light guide degraded energy resolution with increasing statistical uncertainty. The results indicated that the SiPM-based scintillation detector with no light guide is the most efficient design for monitoring radionuclides in an aquatic environment.