• Title/Summary/Keyword: PMSM Position Sensorless control

Search Result 76, Processing Time 0.021 seconds

Simulation Model of Harmonics Injection Sensorless Technique for Permanent Magnet Synchronous Motor (영구자석 동기 전동기의 고조파 주입 센서리스 기법 시뮬레이션 모델)

  • Yoon, Jin-Woo;Lee, Dong-Myung
    • Journal of IKEEE
    • /
    • v.24 no.1
    • /
    • pp.67-71
    • /
    • 2020
  • In this study, a simulation model of the harmonic injection sensorless control technique is proposed. This model is suitable for the sensorless technique of low-speed area operation of motors. The motor of this model is permanent magnet motor. For sensorless control, 1kHz square wave is injected. The change in motor constant according to rotor position is realized by having different d-q inductance values. Sensorless techniques is implemented through functions of Simulink and models provided by Simulink libraries. It is shown that the harmonic component contained in the current is extracted using a filter, and the angle of the permanent magnet of the motor is detected using the extracted waveform. The validity of the simulation model is demonstrated through the estimated motor angle waveform and the related waveforms of the motor control applied to the 1kW permanent magnet motor.

Square Wave Voltage Injection Starting Method of SP-PMSM Considering Nonlinearity of Full-bridge Inverter (풀 브릿지 인버터의 비선형성을 고려한 단상 영구자석 동기 전동기의 구형파 전압 주입 기동 기법)

  • Yoo, Sang-Min;Hwang, Seon-Hwan;Lee, Ki-Chang
    • Journal of Aerospace System Engineering
    • /
    • v.16 no.3
    • /
    • pp.93-98
    • /
    • 2022
  • The purpose of this paper was to propose a method for improving the performance of the open-loop control of single-phase permanent magnet synchronous motor (SP-PMSM), based on a square wave voltage injection. Generally, the SP-PMSM driving systems cmprise a full-bridge inverter and asymmetric air-gap structure of magnetic circuit, because a zero torque occurs on the symmetrical air-gap. As a result, it cannot be started at a specific rotor position. Thus, it is possible to cause the start-up failure at an open-loop control for sensorless operation of SP-PMSM. In this paper, the method with square wave voltage injection considering the nonlinearity of the inverter is presented to resolve the problem. The effectiveness of the proposed algorithm is verified through several experiments.

Sensorless Control Strategy of IPMSM Based on a Parallel Reduced-Order Extended Kalman Filter (병렬형 저감 차수 칼만 필터를 이용한 매입형 영구자석 동기전동기의 센서리스 제어)

  • Yim, Dong-Hoon;Park, Byoung-Gun;Kim, Rae-Young;Hyun, Dong-Seok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.3
    • /
    • pp.266-273
    • /
    • 2011
  • This paper proposes a novel sensorless control scheme for a Permanent Magnet Synchronous Motor (PMSM) by using a parallel reduced-order Extended Kalman Filter. The proposed scheme can obtain rotor position and speed by back-EMF that is estimated by reduced-order EKF and save computation time greatly due to using a parallel structure that works by turns every sampling time. Therefore, proposed scheme has merits of conventional EKF, and problems of parameter sensitivity are partially overcome. And proposed scheme can safely estimate rotor speed and position by using new algorithms according to driving regions. Experimental results show the validity of the proposed estimation technique, and to verify the merit of the proposed scheme, a comparison of a new reduced-order EKF algorithm with a conventional EKF algorithm has been also made in terms of computation time.

Improvement of Initial Rotor Position Detection for Permanent-Magnet Synchronous Motor Using Magnetic Position Sensor (영구자석형 동기전동기에서 자기식 위치 센서를 사용한 초기 회전자 위치 검출 성능의 개선)

  • Park, Mun-Su;Yoon, Duck-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.6
    • /
    • pp.398-404
    • /
    • 2021
  • This paper proposes a method of using a magnetic position sensor to detect accurately the rotor position required to perform vector control of a permanent-magnet synchronous motor, particularly the initial rotor position at startup. In the existing vector control systems, the initial rotor position was determined using the output signals of the Hall sensors, or the control was performed in a sensorless method without using such a sensor. On the other hand, the accuracy is degraded due to the occurrence of a position detection error, and the practicality was not satisfactory. This paper attempts to detect the initial rotor position using a magnetic position sensor to solve this problem. This method is used to solve the deteriorating starting characteristics of the motor in the vector control system. In addition, to lower the price of a low-power vector control inverter, this paper proposes a method of integrating the existing sensors and reducing the price to less than half using a magnetic position sensor for speed and position detection.

Speed Sensorless Control of IPMSM Drive of ANN (ANN에 의한 PMSM의 속도제어)

  • Lee, Hong-Gyun;Lee, Jung-Chul;Jung, Tack-Gi;Lee, Young-Sil;Chung, Dong-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.1120-1123
    • /
    • 2003
  • This paper is proposed a ANN-based rotor position and speed estimation method for IPMSM by measuring the currents. Because the proposed estimator treats the estimated motor speed as the weights, it is possible to estimate motor speed to adapt back propagation algorithm with 2 layered neural network. The proposed control algorithm is applied to IPMSM drive system. The operating characteristics controlled by neural networks control are examined in detail.

  • PDF

Eliminating Method of Estimated Magnetic Flux Offset in Flux based Sensorless Control of PM Synchronous Motor using High Pass filter with Variable Cutoff Frequency (모터 운전 주파수에 동기화된 차단주파수를 갖는 HPF(High pass filter)를 적용한 영구자석 동기전동기의 자속기반 센서리스 제어의 추정 자속 DC offset 제거 기법)

  • Kang, Ji-Hun;Cho, Kwan-Yuhl;Kim, Hag-Wone
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.3
    • /
    • pp.455-464
    • /
    • 2019
  • The sensorless control based on the flux linkage of PM synchronous motors has excellent position estimation characteristics at low speeds. However, a limitation arises because the integrator of flux estimator is saturated by the DC offset generated during the analog to digital conversion(ADC) process of the measured current. In order to overcome this limitation, HPF with a low cutoff frequency is used. However, the estimation performance is deteriorated (Ed- the verb deteriorate already includes the meaning of 'problem') at high speed due to the low cutoff frequency, and increasing the cutoff frequency of the HPF induces further problems of phase leading and initial starting failure at low speeds. In this paper, the cutoff frequency of HPF was synchronized to the operation frequency of the motor: at low speeds the cutoff frequency was set to low in order to reduce the phase leading of the estimated flux, and at high speeds it was set to high to raise the DC offset removal performance. As a result, the operating range was increased by 200%. Furthermore, a phase compensation algorithm is proposed to reduce the phase leading of the HPF to less than 1.5 degrees over the full operating range. The proposed sensorless control algorithm was verified by experiment with a PM synchronous motor for a washing machine.