• Title/Summary/Keyword: PMMA material

검색결과 232건 처리시간 0.053초

투명방음판의 품질기준 설정에 관한 연구(1) - 기계적 특성 및 안전성 평가 (Study on Quality Criteria for Transparent Soundproof Panels(1) - Evaluation of Mechanical Performance and Safety)

  • 장태순;김철환;황철호
    • 한국소음진동공학회논문집
    • /
    • 제20권12호
    • /
    • pp.1111-1120
    • /
    • 2010
  • A variety of materials may be used for soundproof panels. The major advantage of transparent material over traditional materials in noise barriers is aesthetics. The transparent panel materials such as clear plastic or glass are an ideal way of reducing or virtually eliminating the visual impact of a noise barrier. With the use of transparent materials, the drivers' view of the roadside and the sunlight penetration to the highway would not be blocked. Korean Industrial Standards for soundproof panels have been established. But, transparent soundproof panels are not included in this standards. And, some specifications provide only a few basic characteristics for transparent soundproof panels. To develop guidelines on quality criteria for transparent soundproof panel, their mechanical properties such as wind load resistance, safety under impact, and abrasion resistance were experimentally investigated.

Numerical modeless of the damage, around inclusion in the orthopedic cement PMMA

  • Mohamed, Cherfi;Smail, Benbarek;Bouiadjra, Bachir;Serier, B.
    • Structural Engineering and Mechanics
    • /
    • 제57권4호
    • /
    • pp.717-731
    • /
    • 2016
  • In orthopedic surgery and more especially in total arthroplastie of hip, the fixing of the implants generally takes place essentially by means of constituted surgical polymer cement. The damage of this materiel led to the fatal rupture and thus loosening of the prosthesis in total hip, the effect of over loading as the case of tripping of the patient during walking is one of the parameters that led to the damage of this binder. From this phenomenon we supposed that a remain of bone is included in the cement implantation. The object of this work is to study the effect of this bony inclusion in the zones where the outside conditions (loads and geometric shapes) can provoke the fracture of the cement and therefore the aseptic lousing of the prosthesis. In this study it was assumed the presence of two bones -type inclusions in this material, one after we analyzed the effect of interaction between these two inclusions damage of damage to this material. One have modeled the damage in the cement around this bone inclusion and estimate the crack length from the damaged cement zone in the acetabulum using the finite element method, for every position of the implant under the extreme effort undergone by the prosthesis. We noted that the most intense stress position is around the sharp corner of the bone fragment and the higher level of damage leads directly the fracture of the total prosthesis of the hip.

Buckling and free vibration analysis of tapered FG- CNTRC micro Reddy beam under longitudinal magnetic field using FEM

  • Mohammadimehr, M.;Alimirzaei, S.
    • Smart Structures and Systems
    • /
    • 제19권3호
    • /
    • pp.309-322
    • /
    • 2017
  • In this paper, the buckling, and free vibration analysis of tapered functionally graded carbon nanotube reinforced composite (FG-CNTRC) micro Reddy beam under longitudinal magnetic field using finite element method (FEM) is investigated. It is noted that the material properties of matrix is considered as Poly methyl methacrylate (PMMA). Using Hamilton's principle, the governing equations of motion are derived by applying a modified strain gradient theory and the rule of mixture approach for micro-composite beam. Micro-composite beam are subjected to longitudinal magnetic field. Then, using the FEM, the critical buckling load, and natural frequency of micro-composite Reddy beam is solved. Also, the influences of various parameters including ${\alpha}$ and ${\beta}$ (the constant coefficients to control the thickness), three material length scale parameters, aspect ratio, different boundary conditions, and various distributions of CNT such as uniform distribution (UD), unsymmetrical functionally graded distribution of CNT (USFG) and symmetrically linear distribution of CNT (SFG) on the critical buckling load and non-dimensional natural frequency are obtained. It can be seen that the non-dimensional natural frequency and critical buckling load decreases with increasing of ${\beta}$ for UD, USFG and SFG micro-composite beam and vice versa for ${\alpha}$. Also, it is shown that at the specified value of ${\alpha}$ and ${\beta}$, the dimensionless natural frequency and critical buckling load for SGT beam is more than for the other state. Moreover, it can be observed from the results that employing magnetic field in longitudinal direction of the micro-composite beam increases the natural frequency and critical buckling load. On the other hands, by increasing the imposed magnetic field significantly increases the stability of the system that can behave as an actuator.

Improved Mesoporous Structure of High Surface Area Carbon Nanofiber for Electrical Double-Layer Capacitors

  • Lee, Young-Geun.;An, Geon-Hyoung;Ahn, Hyo-Jin
    • 한국재료학회지
    • /
    • 제27권4호
    • /
    • pp.192-198
    • /
    • 2017
  • Carbon nanofiber (CNF) is used as an electrode material for electrical double layer capacitors (EDLCs), and is being consistently researched to improve its electrochemical performance. However, CNF still faces important challenges due to the low mesopore volume, leading to a poor high-rate performance. In the present study, we prepared the unique architecture of the activated mesoporous CNF with a high specific surface area and high mesopore volume, which were successfully synthesized using PMMA as a pore-forming agent and the KOH activation. The activated mesoporous CNF was found to exhibit the high specific surface area of $703m^2g^{-1}$, total pore volume of $0.51cm^3g^{-1}$, average pore diameter of 2.9 nm, and high mesopore volume of 35.2 %. The activated mesoporous CNF also indicated the high specific capacitance of $143F\;g^{-1}$, high-rate performance, high energy density of $17.9-13.0W\;h\;kg^{-1}$, and excellent cycling stability. Therefore, this unique architecture with a high specific surface area and high mesopore volume provides profitable synergistic effects in terms of the increased electrical double-layer area and favorable ion diffusion at a high current density. Consequently, the activated mesoporous CNF is a promising candidate as an electrode material for high-performance EDLCs.

ACCURACY OF THE IMPRESSION TECHNIQUE USING THERMOFORMING POLYMETHYL METHACRYLATE TRAY

  • Miyashita, Yuko;Suzuki, Hiroki;Kishi, Masataka;Ko, Sok-Min
    • 대한치과보철학회지
    • /
    • 제45권3호
    • /
    • pp.389-400
    • /
    • 2007
  • Statement of problem. Use of the conventional dental impression procedure is problematic in patients who have difficulty opening their mouth, difficulty breathing through their nose or tendency to gag. Purpose. It is necessary to make individual trays more comfortable for patients during impression taking procedure. It was reported at the KAP Annual Meeting 2001 Seoul that an improved impression technique was suitable for this purpose. In this study, the accuracy of the improved dental impression method for implant was compared with the conventional dental impression method. Material and methods. An oral simulator was made from clear acrylic resin block which had similar form of edentulous ridge. For setting up the standard, five fixtures were installed on it. Study casts were made using two kinds of impression techniques. One was the conventional method that was taken using silicone impression material and an individual resin tray under connection of inter-fixture relation. The other was the improved method in which was the connection of the impression coping and the thermoformed polymethyl methacrylate tray. In addition, two different study casts were made from the improved impression body. The coordinates of the fixture on the study model were measured by three-dimensional coordinate measuring equipment. Then the distances between each fixture were calculated and compared with that of oral simulator. Accuracy of the each impression method was also assessed. Results. The differences of inter-fixture dimension between study casts and simulator in the improved impression technique showed $0.014{\pm}0.016mm$ and $0.017{\pm}0.022mm$, respectively and that of the conventional method was $0.017{\pm}0.014mm$. There was no significant difference between the improved impression technique and conventional method. Conclusion. The improved impression technique is useful for multiple support implants.

충격 전달에 의한 Gap Test의 폭굉 반응 해석 (A Study on Shock-induced Detonation in Gap Test)

  • 김보훈;강원규;장승교;박정수;여재익
    • 한국추진공학회지
    • /
    • 제20권2호
    • /
    • pp.75-85
    • /
    • 2016
  • 감쇠기를 사이에 두고 여폭약과 수폭약으로 충전된 파이로 착화기는 격벽의 압력 감쇠 현상과 고에너지 물질의 충격 점화 특성을 갖는다. 고폭약의 폭굉 반응 및 비반응 물질 통과에의 폭압 감쇠와 더불어 격벽의 형상 변화를 모사하기 위해서는 충격 전달에 의한 gap test의 폭굉 모델링이 필요하다. 본 연구에서는 오일러리안 레벨셋 기법이 적용된 다중물질 하이드로 코드를 사용하여 pentolite 작약과 열폭압 RDX의 폭발 반응 및 PMMA gap을 통과하는 충격파 전달을 해석함으로써 화약-격벽간 상호작용 및 임계 두께, 음향 임피던스, go/no-go 기폭 점화에 대한 특성을 정량화하였다.

Simultaneous Transfer and Patterning of CVD-Grown Graphene with No Polymeric Residues by Using a Metal Etch Mask

  • 장미;정진혁;;이내응
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제44회 동계 정기학술대회 초록집
    • /
    • pp.642-642
    • /
    • 2013
  • Graphene, two dimensional single layer of carbon atoms, has tremendous attention due to its superior property such as high electron mobility, high thermal conductivity and optical transparency. Especially, chemical vapor deposition (CVD) grown graphene has been used as a promising material for high quality and large-scale graphene film. Unfortunately, although CVD-grown graphene has strong advantages, application of the CVD-grown graphene is limited due to ineffective transfer process that delivers the graphene onto a desired substrate by using polymer support layer such as PMMA(polymethyl methacrylate). The transferred CVD-grown graphene has serious drawback due to remaining polymeric residues generated during transfer process, which induces the poor physical and electrical characteristics by a p-doping effect and impurity scattering. To solve such issue incurred during polymer transfer process of CVD-grown graphene, various approaches including thermal annealing, chemical cleaning, mechanical cleaning have been tried but were not successful in getting rid of polymeric residues. On the other hand, lithographical patterning of graphene is an essential step in any form of microelectronic processing and most of conventional lithographic techniques employ photoresist for the definition of graphene patterns on substrates. But, application of photoresist is undesirable because of the presence of residual polymers that contaminate the graphene surface consistent with the effects generated during transfer process. Therefore, in order to fully utilize the excellent properties of CVD-grown graphene, new approach of transfer and patterning techniques which can avoid polymeric residue problem needs to be developed. In this work, we carried out transfer and patterning process simultaneously with no polymeric residue by using a metal etch mask. The patterned thin gold layer was deposited on CVD-grown graphene instead of photoresists in order to make much cleaner and smoother surface and then transferred onto a desired substrate with PMMA, which does not directly contact with graphene surface. We compare the surface properties and patterning morphology of graphene by scanning electron microscopy (SEM), atomic force microscopy(AFM) and Raman spectroscopy. Comparison with the effect of residual polymer and metal on performance of graphene FET will be discussed.

  • PDF

아토마이징 제강 환원슬래그를 사용한 폴리머 콘크리트 복합재료의 특성 (I) (PMMA 수축저감재를 사용) (Characteristics of Concrete Polymer Composite Using Atomizing Reduction Steel Slag (I) (Use of PMMA as a Shrinkage Reducing Agent))

  • 황의환;김진만
    • 공업화학
    • /
    • 제25권2호
    • /
    • pp.181-187
    • /
    • 2014
  • 구형의 아토마이징 제강 환원슬래그(래들로 슬래그)를 폴리머 콘크리트 복합재료의 잔골재 대신 사용하기 위하여 아토마이징 제강 환원슬래그의 대체율과 폴리머 결합재의 첨가율을 다양하게 변화시켜 공시체를 제작하였다. 공시체의제 물성을 조사하기 위하여 흡수시험, 압축 및 휨강도, 내열수성시험, 세공분포측정 및 SEM에 의한 미세조직 관찰을 실시하였다. 그 결과 폴리머 결합재 7.5% 첨가한 공시체는 제강 환원슬래그의 대체율이 증가됨에 따라 압축 및 휨강도가 증가되었으나 폴리머 결합재 8.0% 이상에서는 유동성의 증가로 인한 재료분리 현상으로 특정한 대체율에서 최대값을 나타내었다. 내열수성시험에 의하여 압축강도, 휨강도, 세공의 평균직경 및 밀도는 감소되었으나 총세공량과 공극률은 증가되었다. 아토마이징 제강 환원슬래그를 잔골재 대신 사용함으로써 유동성이 현저히 증가되어 폴리머 결합재의 사용량을 최대 23.5%까지 절감할 수 있는 것으로 나타났다. 그러나 아토마이징 제강 환원슬래그를 사용함으로써 내열수성이 감소되기 때문에 더 많은 연구가 요구된다.

미세가공 기술 기반의 마이크로니들 어레이 개발 및 패럴린 적용 가능성에 관한 연구 (Research on the Development of Microneedle Arrays Based on Micromachining Technology and the Applicability of Parylene-C)

  • 김동국;윤덕규;이용찬;김민욱;노지형;서요한;강관수;정영훈;김경아;송태하
    • 대한의용생체공학회:의공학회지
    • /
    • 제44권6호
    • /
    • pp.404-413
    • /
    • 2023
  • In this research, we studied the development of a SUS304 microneedle array based on microfabrication technology and the applicability of Parylene-C thin film, a medical polymer material. First of all, four materials commonly used in the field of medical engineering (SUS304, Ti, PMMA, and PEEK) were selected and a 5 ㎛ Parylene-C thin film was deposited. The applicability of Parylene-C coating to each material was confirmed through SEM analysis, contact angle measurement, surface roughness(Ra) measurement, and adhesion test according to ASTM standards for each specimen. Parylene-C thin film was deposited based on chemical vapor deposition (CVD), and a 5 ㎛ Parylene-C deposition process was established through trial and error. Through characteristic experiments to confirm the applicability of Parylene-C, SUS304 material, which is the easiest to apply Parylene-C coating without pretreatment was selected to develop a microneedle array based on CNC micromachining technology. The CNC micromachining process was divided into a total of 5 steps, and a microneedle array consisting of 19 needles with an inner diameter of 200 ㎛, an outer diameter of 400 ㎛, and a height of 1.4 mm was designed and manufactured. Finally, a 5 ㎛ Parylene-C coated microneedle array was developed, which presented future research directions in the field of microneedle-based drug delivery systems.

불안정성 흉·요추부 골절에 대한 단 분절 척추경 나사못 고정술 및 추체 보강 성형술 - 예 비 보 고 - (Short Segment Pedicle Screw Fixation with Augmented Intra-Operative Vertebroplasty in Unstable Thoraco-Lumbar Fracture - Preliminary Report -)

  • 김영우;오성한;윤도흠;진동규;조용은;김영수
    • Journal of Korean Neurosurgical Society
    • /
    • 제30권11호
    • /
    • pp.1271-1277
    • /
    • 2001
  • Objectives : Since vertebroplasty has been introduced, we performed short segment pedicle screw fixation with augmented intra-operative vertebroplasty in patients with unstable thoraco-lumbar fracture. Our intentions are to demonstrate the efficacy and indication of this new technique compare to conventional methods. Material and Methods : The surgery comprised of pedicle screw fixations on one level above and below the fracture site, and the fractured level itself, if pedicle is intact, and intra-operative vertebroplasty under the fluoroscopic guide with in-situ postero-lateral bone graft. Also, in cases of bone apposition, we removed those with small impactor through a transfascetal route. During the last 2 years, we performed in seven(7) unstable thoraco-lumbar fracture patients who consisted of two different characteristics, those four(4) with primary or secondary osteoporosis and three(3) of young and very healthy. All patients were followed clinically by A.S.I.A. score and radiography. Results : Mean follow up period was 14 months. We observed well decompressed state via transfascetal route in cases of bone fragments apposition and no hardware pullout in osteoporotic cases, no poly-methyl-methacrylate (PMMA) leakage through the fracture sites into the spinal canal, and no kyphotic deformities in both cases during follow-up periods. All patients demonstrated solid bony fusion except one following osteoporotic compression fracture on other sites. Conclusions : In the management of unstable thoraco-lumbar fracture, we believe that this short segment pedicle screw fixation with augmented intra-operative vertebroplasty reduce the total length or levels of pedicle screw fixation without post-operative kyphotic deformity.

  • PDF