• Title/Summary/Keyword: PMMA (Polymethylmethacrylate) Bone Cement

Search Result 18, Processing Time 0.027 seconds

Numerous Bilateral Radiographically Dense Branching Opacities after Vertebroplasty with Polymethylmethacrylate (Polymethylmethacrylate를 이용한 경피적 척추성형술 후 흉부 X선에서 관찰된 다수의 양측성, 분지상 선상 음영)

  • Cho, Jun Hyun;Jung, Jong Pil;Eum, Jun-Bum;Seo, Kwang Won;Jegal, Yang Jin;Choi, Seong Hoon;Ahn, Jong Joon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.61 no.2
    • /
    • pp.184-188
    • /
    • 2006
  • Percutaneous vertebroplasty consists of the percutaneous injection of polymethylmethacrylate (PMMA) cement into a collapsed vertebral body in order to obtain pain relief and mechanically strengthen the vertebral body. This procedure is now extensively used in treating osteoporotic vertebral compression fracture. It is an efficient treatment, but it is not free of complications. Most complications after vertebroplasty are associated with PMMA leakage. Pulmonary embolism of PMMA is rare, but this can occur when there is a failure to recognize venous migration of cement early during the procedure. We encountered a case of a patient with asymptomatic pulmonary embolism because of PMMA after percutaneous vertebroplasty. Chest X-ray and CT scanning revealed numerous tubular branching opacities that corresponded to the pulmonary vessels at the segmental and subsegmental levels.

A Microstructural Analysis for Preventive Treatments of Vertebral Fracture (척추 골절의 예방적 치료법에 관한 미세 구조해석)

  • 김형도;탁계래;김한성;이성재
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.146-149
    • /
    • 2002
  • It is reported that the mechanical properties of vertebral trabecular bone depend on the density and the mass of bones. Osteoporosis is a systemic skeletal disease caused by low bone mass and microstructure deterioration of trabecular bone. Silva and Gibson (1997) studied the treatment of age-related bone loss using drug therapy. Vertebroplasty is a minimally invasive surgery for the treatment of osteoporosis vertebrae. This procedure includes puncturing vertebrae and filling with Polymethylmethacrylate (PMMA). However, the relative effect of drug therapy and bone cement for osteoporosis treatment is not reported yet. In this study, several 2D models of human vertebral trabecular bone are analyzed by finite element method. The mechanical behaviors of the vertebral trabecular bone treated by the drug therapy and the bone cement are compared. This study shows that bone cement treatment is more effective strategy than drug therapy to prevent the degradation of bone strength.

  • PDF

Design and Implementation of A Medical Image Guided System for Vertebroplasty (척추성형술을 위한 의료 영상 시스템의 설계 및 개발)

  • Tack, Gye-Rae;Lee, Sang-Bum;Lee, Sung-Jae
    • The KIPS Transactions:PartB
    • /
    • v.10B no.5
    • /
    • pp.503-508
    • /
    • 2003
  • Since surgical treatment of the spine should overcome neurological compromises, the operative procedures need to be carefully planned and carried out with high degree of precision. Percutaneous vertebroplasty is a surgical procedure that was introduced for the treatment of compression fracture of the vertebrae. This procedure includes puncturing vertebrae and filling with polymethylmethacrylate (PMMA). Recent studies have shown that the procedure could provide structural reinforcement for the osteoporotic vertebrae while being minimally invasive and safe with immediate relief of pain. However, failures of treatment due to excessive PMMA volume injection have been reported as one of complications in vertebroplasty. It is believed that the control of PMMA volume is one of the most critical factors that can reduce the incidence of complications. Therefore, clinical success of vertebroplasty can be dependent on the volume of PMMA injection for a given patient. In this study, the optimal volume of PMMA injection for vertebroplasty was predicted based on the image analysis of a given patient.

STUDY OF POLYMETHYL METHACRYLATE BONE CEMENT CONTAINING BOVINE-DERIVED DEFATTING DEMINERALIZED BONE POWDER (탈지방탈회우골분말과 Polymethyl Methacrylate(PMMA) Bone Cement 혼합제에 관한 연구)

  • Kim, Woon-Kyu;Kim, Su-Gwan;Cho, Se-In;Ko, Young-Moo;Yoon, Jung-Hoon;Ahn, Jong-Mo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.27 no.6
    • /
    • pp.491-497
    • /
    • 2001
  • Polymethylmethacrylate(PMMA) is currently commonly used material for the reconstruction of bone defects and fixation of joint prosthetics following congenital and acquired causes. Although PMMA has widespread use, it does not possess the ideal mechanical characteristics with osteoconductivity and osteoinductivity required. In order to overcome these problem, addition of bovine bone drived defatting demineralized bone(BDB) powders to a PMMA bone cement was done for improvement of physical property and bone forming characteristics of composite. In order to investigate the influence of BDB reinforcement on the PMMA, we measured physical property of compressive, tensile, flexural strength, and scanning electron microscopic examinations. The results were obtained as follows: 1. The PMMA forms a solid cellular matrix with open cells about $100{\mu}m$ in variable size and incorporating BDB. BDB aggregates inside the cells form a porous network that is accessible from the outer surface. 2. The physical properties were compressive strength of mean $22.74{\pm}1.69MPa$, tensile strength of mean $22.74{\pm}1.69MPa$, flexural strength of mean $77.53{\pm}6.93MPa$. Scanning electron microscopic examinations were revealed that there was DBD particles form a highly porous agglomerates. BDB can be added PMMA in the form of dried powders, the composites are applicable as bone substitutes. BDB and PMMA mixture is shown to produce a class of composites that due to their microstructure and improved mechanical properties may be suitable for application as bone subsitutes. The mechanical and material properties of the BDB-PMMA bone substitute composites are competitive with those properties of a porous ceramic matrix of other hydroxyapatite and with those of natural bones.

  • PDF

Influence of porosity on the behavior of cement orthopaedic of total hip prosthesis

  • Ali, Benouis;Boualem, Serier;Smail, Benbarek
    • Biomaterials and Biomechanics in Bioengineering
    • /
    • v.2 no.4
    • /
    • pp.197-206
    • /
    • 2015
  • This paper presents three-dimensional finite element method analyses of the distribution of equivalents stress of Von Mises. Induced around a cavity located in the bone cement polymethylmethacrylate (PMMA). The presences and effect of its position in the cement was demonstrated, thus on the stress level and distribution. The porosity interaction depending on their positions, and their orientations on the interdistances their mechanical behaviour of bone cement effects were analysed. The obtained results show that micro-porosity located in the proximal and distal zone of the prosthesis is subject to higher stress field. We show that the breaking strain of the cement is largely taken when the cement, containing the porosities very close adjacent to each other.

Repeat Vertebroplasty for the Subsequent Refracture of Procedured Vertebra

  • Choi, Sang Sik;Hur, Won Seok;Lee, Jae Jin;Oh, Seok Kyeong;Lee, Mi Kyoung
    • The Korean Journal of Pain
    • /
    • v.26 no.1
    • /
    • pp.94-97
    • /
    • 2013
  • Vertebroplasty (VP) can effectively treat pain and immobility caused by vertebral compression fracture. Because of complications such as extravasation of bone cement (polymethylmethacrylate, PMMA) and adjacent vertebral fractures, some practitioners prefer to inject a small volume of PMMA. In that case, however, insufficient augmentation or a subsequent refracture of the treated vertebrae can occur. A 65-year-old woman visited our clinic complaining of unrelieved severe low back and bilateral flank pain even after she had undergone VP on the $1^{st}$ and $4^{th}$ (L1 and L4) lumbar vertebrae a month earlier. Radiologic findings showed the refracture of L1. We successfully performed the repeat VP by filling the vertebra with a sufficient volume of PMMA, and no complications occurred. The patient's pain and immobility resolved completely three days after the procedure and she remained symptom-free a month later. In conclusion, VP with small volume cement impaction may fail to relieve fracture-induced symptoms, and the refracture of an augmented vertebral body may occur. In this case, repeat VP can effectively resolve both the persistent symptoms and problems of new onset resulting from refracture of the augmented vertebral body due to insufficient volume of bone cement.

Total Hip Replacement in a Jindo Dog with Dorsal Acetabular Rim Deficiency: a Case Report (등쪽 관골절구 결손을 가진 진도견의 인공 대퇴 관절 전치환술)

  • Heo, Su-Young;Lee, Hae-Beom
    • Journal of Veterinary Clinics
    • /
    • v.31 no.2
    • /
    • pp.121-124
    • /
    • 2014
  • A 7-year-old, intact female Jindo dog was presented for assessment of weight-bearing lameness of the right hindlimb. On physical examination, crepitus and pain was noted in the right coxofemoral joint upon extension. Radiographs revealed a craniodorsal luxation of the right coxofemoral joint and degenerative joint disease (DJD) of both coxofemoral joints. Total hip replacement (THR) was performed for the right coxofemoral joint. Intraoperatively, dorsal acetabular rim (DAR) deficiency was noted, which can be related to a high risk for acetabular cup implant dislocation. Deficiency of the dorsal acetabular rim realigned with the acetabular cup using universal locking plate (ULP) and polymethylmethacrylate (PMMA) bone cement. After surgery, the patient had an uneventful course and a successful outcome. The ROM and thigh girth were dramatically improved. There were no complications associated with prosthesis implants. Hip luxation with dorsal acetabular rim deficiency in a dog was successfully repaired with THR and dorsal acetabular rim augmentation using ULP and PMMA bone cement. This technique should be considered when conventional THR is precluded by dorsal acetabular rim deficiency.

Bone Cement Augmentation of Pedicular Screwing in Severe Osteoporotic Spondylolisthetic Patients

  • Kim, Hyeun-Sung;Park, In-Ho;Ryu, Jae-Kwang;Kim, Seok-Won;Shin, Ho
    • Journal of Korean Neurosurgical Society
    • /
    • v.42 no.1
    • /
    • pp.6-10
    • /
    • 2007
  • Objective : The purpose of this study was to determine the effect of bone cement augmentation of pedicular screwing in severe osteoporotic spondylolisthetic patients. Methods : Twenty patients with spondylolisthesis (8 : spondylolytic spondylolisthesis 12 : degenerative spondylolisthesis) who had undergone pedicular screwing and interbody fusion for osteoporotic lumbar spine (T-score on bone mineral density<-3.0) from 2002 to 2005 were reviewed. Mean age was 62.3 years with 3 male and 17 female patients. Average follow-up period was 14 months. Average T-score on bone mineral density (BMD) was -3.62. After decompression of neural elements, about 6cc of polymethylmethacrylate (PMMA) was injected into the each vertebral body through transpedicular route. All patients underwent one level interbody fusion and pedicular screw fixation. Clinical outcome was assessed using Oswestry Disability Index (ODI) on the last clinical follow-up. In addition, a modified MacNab's grading criteria was used to objectively assess patient's outcome postoperatively. Radiographic analysis of sagittal contour was assessed preoperatively, immediately postoperatively, and at final follow-up including fusion rate. Results : Eighteen of 20 patients were graded as excellent or good according to the modified MacNab's criteria. An significant improvement of ODI was achieved in both groups. Mean sagittal angle at the preoperative state, postoperative state and at the last follow-up state was $11.0^{\circ},\;20.1^{\circ}$ and $18.3^{\circ}$, respectively, with mean sagittal angle correction gain $7.3^{\circ}$. Firm fusion was achieved in all patients. There were one compression fracture above the fused segment after 6 months follow-up and one case of seroma. But there were no postoperative complications related to bone cement leakage and pedicular screwings such as screw pullout or screw cut-up. Conclusion : Bone cement augmentation of pedicular screwing can be an effective procedure for osteoporotic lumbar spine in spondylolisthetic patients.

Stress Analysis of Total Knee System Depending on Implant Materials and Fixation Methods (인공무릎관절에 있어서 임플란트의 재료 및 고정방법에 따른 응력분석)

  • Cho, C.H.;Cho, Y.K.;Choi, J.B.;Choi, K.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.484-488
    • /
    • 1997
  • Three-dimensional finite element analyses were used to compare the stress distribution and the stability of the fixation among seven different tibial components and to investigate the effect due to implant materials in total knee arthroplasty. The components included an intact tibia(Type I), Cemented Cobalt-Chromium tibial tray implanted with a PMMA cemented Co-Cr stem(Type II), Cemented Co-Cr tibial tray with a uncemented Co-Cr stem(Type III), Cemented Ultra High Molecular Weight Polyethylene (UHMWPE) tibial tray with a cemented UHMWPE stem (Type IV), Cemented UHMWPE tray with a uncemented UHMWPE stem(Type V), Cemented Co-Cr tray without a stem(Type VI), and Cemented UHMWPE tray without a stem(Type VII). Uncemented components were assumed to have complete bony in growth and a rigid state of fixation between component and bone. The interface between bone/cement/component of cemented components was also assumed to be fully bonded. Bi-condylar forces were applied. The results indicated that Uncemented stem components provided lower bone stress shielding and stress concentration. The UHMWPE tray and stem component showed better agreement with the intact tibia than the Co-Cr Alloy tray and stem components. If the implant tray can be fixed firmed without a stem, Cemented PE tray without a stem(Type VII) may be recommended to give the best characteristics in the sense of stress distribution and stability.

  • PDF

Fe3O4 magnetic nanoparticles provide a novel alternative strategy for Staphylococcus aureus bone infection

  • Youliang, Ren;Jin, Yang;Jinghui, Zhang;Xiao, Yang;Lei, Shi;Dajing, Guo;Yuanyi, Zheng;Haitao, Ran;Zhongliang, Deng;Lei, Chu
    • Advances in nano research
    • /
    • v.13 no.6
    • /
    • pp.575-585
    • /
    • 2022
  • Due to its biofilm formation and colonization of the osteocyte-lacuno canalicular network (OLCN), Staphylococcus aureus (S.aureus) implant-associated bone infection (SIABI) is difficult to cure thoroughly, and may occur recurrently subsequently after a long period dormant. It is essential to explore an alternative therapeutic strategy that can eradicate the pathogens in the infected foci. To address this, the polymethylmethacrylate (PMMA) bone cement and Fe3O4 nanoparticles compound cylinder were developed as implants based on their size and mechanical properties for the alternative magnetic field (AMF) induced thermal ablation, The PMMA mixed with optimized 2% Fe3O4 nanoparticles showed an excellent antibacterial efficacy in vitro. It was evaluated by the CFU, CT scan and histopathological staining on a rabbit 1-stage transtibial screw model. The results showed that on week 7, the CFU of infected soft tissue and implants, and the white blood cells (WBCs) of the PMMA+2% Fe3O4+AMF group decreased significantly from their controls (p<0.05). PMMA+2% Fe3O4+AMF group did not observe bone resorption, periosteal reaction, and infectious reactive bone formation by CT images. Further histopathological H&E and Gram Staining confirmed there was no obvious inflammatory cell infiltration, neither pathogens residue nor noticeably burn damage around the infected screw channel in the PMMA+2% Fe3O4+AMF group. Further investigation of nanoparticle distributions in bone marrow medullary and vital organs of heart, liver, spleen, lung, and kidney. There were no significantly extra Fe3O4 nanoparticles were observed in the medullary cavity and all vital organs either. In the current study, PMMA+2% Fe3O4+AMF shows promising therapeutic potential for SIABI by providing excellent mechanical support, and promising efficacy of eradicating the residual pathogenic bacteria in bone infected lesions.