• 제목/요약/키워드: PMMA(Poly methyl meth acrylate)

검색결과 10건 처리시간 0.048초

경사 LIGA 공정을 이용한 미세 바늘 어레이의 제작 (Fabrication of Microneedle Array Using Inclined LIGA Process)

  • 문상준;이승섭
    • 대한기계학회논문집A
    • /
    • 제28권12호
    • /
    • pp.1871-1876
    • /
    • 2004
  • We demonstrate a novel fabrication technology for the microneedle array that can be used in the medical test field, which is transdermal drug delivery and blood analyte sampling. Previous researchers have used silicon-processed micromachining, a reactive ion etching, and molding techniques for the fabrication of microneedle array. However, these fabrication techniques have somewhat limitations apply to the microneedle array fabrication according to its application. Inclined LIGA process is suggested to overcome these problems. This process provides easier, sharper and longer out-of-plane microneedle array structure than conventional silicon-processed fabrication method did. Additionally, because of the advantage of the LIGA process based on mold fabrication for mass production, the polymer, PMMA(PolyMethylMethAcrylate), based microneedle array is useful as the mold base of nickel electroplating process; on the other hand, silicon-processed microneedle array is used in itself. In this research, we fabricate different types of out-of-plane microneedle array, which have different shape of tip, base and hole structure, using the inclined LIGA process. The fabricated microneedles have proper mechanical strength, height and sharpness to puncture human hand epidermis or dermis with less pain and without needle tip break during penetrating the skin.

광 정보저장용 픽업 렌즈의 다이아몬드 터닝 가공 (Diamond turning of pick-up lens for optical application)

  • 박순섭;김대중;이봉주;김상석;김정호;유영문;김주하
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.525-528
    • /
    • 2003
  • The aspherical lens are used as objective lens of optical pickup. The sample product is made before manufacturing the injection mould of lens to examine the design factor. The optimum cutting conditions of the main spindle speed, the depth of cut, the feed rate are found when we cut PMMA and PC lens sample with ultra-precision SPDT. The demanded surface roughness 10 nm Ra. aspherical form error 0.5 ${\mu}{\textrm}{m}$ P-V for aspherical lens of optical data storage device are satisfied for PMMA. but not satisfied for PC.

  • PDF

감광성 폴리이미드의 광학적 특성 분석 (A study for the optical property in the photodefinable Polyimide)

  • 류현호;정재완;이승걸;오범환;이일항
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2001년도 제12회 정기총회 및 01년도 동계학술발표회
    • /
    • pp.162-163
    • /
    • 2001
  • 폴리머를 이용한 광통신 소자는 실리카를 재료로 사용하는 소자와는 달리 고품질의 박막을 얻는 과정이 단순하고, 소자의 제조단가를 줄일 수 있어 많은 주목을 받고 있다 광통신 소자에 응용되는 여러 폴리머 중에서도 폴리이미드는 PMMA (Poly Methyl MethAcrylate) 등 다른 고분자 물질에 비해서 매우 높은 열적 및 환경적 안정성을 가지고 있는 것으로 알려져 있다. 또한 최근에는 폴리이미드가 가지는 단점인 복굴절과 흡수를 낮추기 위하여 불소기 등을 함유한 폴리이미드가 개발되었으며, 굴절률 조정 또한 용이하게 되었다. (중략)

  • PDF

초정밀가공기를 이용한 SIL 렌즈의 절삭특성 (The Characteristics of SIL Lens Machining Using Diamond Turning Machine)

  • 원종호;박원규;김주환;김건희
    • 한국기계가공학회지
    • /
    • 제2권1호
    • /
    • pp.63-68
    • /
    • 2003
  • The aspherical lenses are used as objective lens of optical pickup. To examine the design factor the sample product is made before manufacturing of injection mould of lens. The optimum cutting condition of PMMA lens sample with ultra precision SPDT, the roam spindle speed, the depth of cut, the feedrate are found. The demanded surface roughness 100m Ra, aspherical form error $0.5{\mu}m$ P-V for aspherical lens of optical data storage device are satisfied.

  • PDF

Electromagnetic interference(EMI) shielding efficiency(SE) charhcteristics of IMI multilayer/PMMA structure for plasma display panel(PDP) filter.

  • Lee, Jung-Hyun;Sohn, Sang-Ho;Cho, Yong;Lee, Sang-Gul
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2006년도 6th International Meeting on Information Display
    • /
    • pp.872-876
    • /
    • 2006
  • This study was made to examine the electromagnetic interference(EMI) shielding effect (SE) of multilayered thin films in which indium-tin oxide(ITO) and Ag were deposited alternately from 3layer to 9 layer on Poly Methyl Meth Acrylate(PMMA) substrate at room temperature using a PF sputtering. We measured optical and electrical characteristics by UV-spectrometer and 4 point probe. The measurement of EMI SE in frequency range from 50MHz to 1.5GHz was performed by using ASTM D4935-89 method. We compared the measured EMI SEs with theoretical simulation data. We obtained relatively low resistivity and high transmittance from the EMI SE multilayers. In this study, we obtain good optical electrical characteristics with a minimun transmittance of about 60% at 550nm wavelength and sheet resistance of $2{\sim}3ohm/sq$., respectivity. Measured EMI SEs were over 50dB and similar to theoretical simulation data.

  • PDF

초정밀가공기를 이용한 광 저장용 렌즈의 절삭특성 (A study of Pickup Lens manufacturing in diamond turing machine)

  • 김건희;홍권희;김효식;박지영;박원규
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 추계학술대회 논문집
    • /
    • pp.891-894
    • /
    • 1997
  • The asphericals lenses are used as objective lens of optical pickup. To examine the design factor the sample product is made before manufacturing of injection mould of lens. The optimum cutting condition of PMMA lens sample with ultra precision SPDT, he main spindle sped, the depth of cut, the feedrate are found. The demanded surface roughness 10nm Ra, aspherical form error 0.5${\mu}{\textrm}{m}$ P-V for aspherical lens of optical data storage device are satisfied.

  • PDF

초절전형 평판 비상등 시스템의 개발 (Development of a Power Saved Flat EXIT Lamp System)

  • 정종혁;강상욱;조영창;최병진;윤정오;홍영호;오주환
    • 한국산업정보학회:학술대회논문집
    • /
    • 한국산업정보학회 2000년도 추계공동학술대회논문집
    • /
    • pp.703-710
    • /
    • 2000
  • 기존의 비상구 표시등은 20-30(W) 정도의 많은 전력 소모와 2천시간 정도의 짧은 램프 수명 등으로 인해 전기에너지의 소모가 많으며, 부피가 커 시공 및 설치가 어렵다. 따라서, 본 논문에서는 도광판을 사용한 비상등의 개발에 관하여 연구하기 위하여 가시광선 투과율이 94%이상으로 높고 가공이 용이한 투명 PMMA(Poly Methyl Meth Acrylate)판에 광반사면을 광학적 시뮬레이션에 의해 설계된 V자형 홈선을 가공하여 비상등의 도광판으로 사용한다. 이 구조는 기존의 비상등에 비해 광이용 효율이 높고, 설계의 자유도가 높아질 것으로 기대된다. 또한, CCFT(Cold Cathode Fluorecent Tube) 램프, 광확산필름, 프리즘필름, 몰드프레임 등을 이용하여 광이용 효율을 극대화하는 구조를 고안하고, 인버터 구동을 위한 주변회로 시스템을 개발하여 초절전형 평판 비상등 시스템의 양산 기술을 확보함을 목적으로 한다. 이로부터 휘도 2000cd/$m^2$, 휘도균일도 90%이상의 특성과 기존의 비상등 대비 전기 에너지 50%이상이 절감 가능한 비상등이 개발될 수 있다.

  • PDF

폴리머 마이크로렌즈 제작 (Polymer Microlens Fabrication)

  • 류근걸;김영근;전광석
    • 청정기술
    • /
    • 제11권4호
    • /
    • pp.205-211
    • /
    • 2005
  • 마이크로렌즈 어레이의 제작은 매우 다양한 재료와 방법이 제안되어 지고 있으나, 폴리머를 이용한 사출법은 광학적 특성, 내충격성, 가공성, 경량화 및 환경친화성 등의 장점으로 주목 받고 있다. 사출법 템플레이트를 제작하기 위한 PR(Photo-Resist) reflow법은 형상제어가 용이하고 대량생산과 정밀가공의 측면에서 효율적이어서, 집적화가 용이하고 공정을 줄일 수 있는 장점을 갖게 되어 매우 환경친화적이다. 그러나 마이크로렌즈 어레이의 사출성형은 사용되는 폴리머재료의 성질에 따라 성형에 어려움이 있는 것으로 알려져 있다. 본 연구에서는 이와 같은 성형의 어려움을 극복하기 위한 방법으로 급가열/급냉각 사출을 통하여 마이크로렌즈 어레이를 제작하고 특성을 이해하였다. 템플레이트의 급격한 온도상승과 고온에서의 모양이 냉각으로 인한 변형이 없도록 급속히 냉각시켜 줌으로서 마이크로렌즈 어레이의 사출성형을 구현 하였다. PC(Poly-Cabon ate)와 PMMA(Poly-Methyl-Meth-Acrylate)를 비교하여, PMMA가 낮은 용융점에 의해 성형성이 우수함을 확인하였다. 사출시 압력과 속도를 변수로 마이크로렌즈 어레이의 제작을 위한 사출조건을 도출하였다.

  • PDF

PMMA Lens의 변형에 미치는 설계변수와 금형온도의 영향 (Effect of Design Parameters and Molding Temperature on Polymethyl Methacrylate Lens Warp)

  • 이선호;허장욱
    • 한국기계가공학회지
    • /
    • 제15권5호
    • /
    • pp.109-116
    • /
    • 2016
  • Polymethyl methacrylate is commonly used in the outer lens of automotive rear lamps. However, if the lens warps above the allowable limit, it may lead to faulty connection with the housing, and failure of the assembly. This study investigated the effects of gate diameter and cooling line distance in the mold design for automotive outer lens. The optimal gate diameter and cooling line distance to minimize the warp of the outer lens were derived as 3.0 mm and 50-60 mm respectively, and the cooling temperature to minimize warp was shown to be $60-80^{\circ}C$ (mold surface temperature $48-67^{\circ}C$). A higher cooling temperature may somewhat mitigate the warp, but is undesirable because it may cause injection molding problems, such as sinks. A mold was constructed matching the optimal design and the produced lens properties, particularly the degree of warp, were comparable with the CAE predictions.