• Title/Summary/Keyword: PM-Tube

Search Result 405, Processing Time 0.027 seconds

Studies on Changes of Ovarian and Placental Weight and Periods of Pregnancy by Progesterone-tube Implantation during Pregnancy in Rats (흰쥐의 번식과정에 있어서 Progesterone-tube 이식이 난소와 태반중량 및 임신기간에 미치는 영향)

  • 민관식;오석두;윤창현
    • Korean Journal of Animal Reproduction
    • /
    • v.14 no.4
    • /
    • pp.281-287
    • /
    • 1990
  • This study was conducted to find out the changes of ovarian, placental and fetal weights and periods of pregnancy in rats implanted with progesterone-tube during the reproductive stages. One hundred and thirty-four mature rats, 10~13 weeks old, were offered for this experiment. The animals, which were implanted with silicon tubes filled with progesterone on day 15 of pregnancy, were sacrified at 18, 20, 21 and 22 days of pregnancy. The changes of ovarian, placental and fetal weights and the number of fetuses during late pregnancy were recorded. The results obtained were summarized as follows : 1. After progesterone-tube implantation, ovarian weight reached to a peak value of 92.0$\pm$0.9mg at 20 days of pregnancy, there after decreased significantly to 79.5$\pm$7.6 and 68.26$\pm$4.2mg at 20 and 22 days of pregnancy(P<0.01). 2. The placental weight increased rapidly during 15~18 days of pregnancy in control and progesterone treated rats. A peak value of 447.78$\pm$20.9mg was shown at 20 days of pregnancy after progesterone-tube implantation, and in control rats the value decreased significantly to 419.42$\pm$11.6 and 404.1$\pm$29.3mg at 20 and 21 days of pregnancy(P<0.01). 3. The fetal weights was not shown any significant differences between control and progesterone-tube implanted rats. 4. The number of fetuses in control rats were 14.75$\pm$0.4 at 8~10 days of pregnancy and 13.5$\pm$0.3 and 13.25$\pm$0.4 at 12 and 20 days of pregnancy. 5. The significant difference in periods of pregnancy was appeared between progesterone-tube implanted(27.3$\pm$0.3 days) and control(22.1$\pm$0.3 days)rats(P<0.01).

  • PDF

Effects on the Esophageal Rewarmer for Repairing in Rabbits with Profound Hypothermia (토끼의 초저체온증 회복을 위한 식도가온법에 관한 연구)

  • 정병현;이병한
    • Journal of Veterinary Clinics
    • /
    • v.17 no.1
    • /
    • pp.138-144
    • /
    • 2000
  • The studies were carried out to investigate the effects of esophageal thermal tube for rewarming in the hypothermia in rabbits. Thiry-one rabbits were continuously cooled with femoral arterio-venous bypass circulation to 25.0${\pm}$0.3$^{\circ}C$(profound hypothermia) of rectal temperature. The experiment was consisted with 3 esophageal thermal tube groups perfused with circulation water at 38${\pm}$1$^{\circ}C$(low, n=12), 42${\pm}$1$^{\circ}C$(medium, n=12), and 45${\pm}$1$^{\circ}C$(high, n=7). Esophageal thermla tube specially constructed double-lumen esophageal tube with circulating warm water at respective htermal grade. With this device, rewarming of the rabbits as follows; High-esophageal thermal tube group(45${\pm}$1$^{\circ}C$)had a more effect on mean arterial pressure(MAP), heart rate(HR), esophageal temperature, and rectal temperature than others groups, but the circulation water at 45$\pm$1$^{\circ}C$ may cause thermal injuries in the esophagus because esophageal temperature increased to 41.1$^{\circ}C$. Medium-esophageal thermal tube group(42${\pm}$1$^{\circ}C$) had a more effect on RR than others groups, but the circulation water at 42${\pm}$1$^{\circ}C$ may also cause thermal injuries in the esophagus if the temperature exceeds 42$^{\circ}C$ for an extended period of time because its esophageal temperature increased to 39.4$^{\circ}C$. Low-esophageal thermal tube group(38${\pm}$1$^{\circ}C$) had a more effect on MAP, RR, and esophageal temperature than others groups. In conclusion, rewarming of the central core in the treatment of profound hypothermia using the esophageal thermal tube perfused with circulation water at 38${\pm}$1$^{\circ}C$ appears to be a ideal alternative safety zone of the temperature of circulation water avoiding thermal injury in esophagus causing by out of order or lower precise thermostat of water bath to that of others groups.

  • PDF

A Study on PAE of Tube Voltage of Diagnostic X-ray Units -At the area of Sungnam, Inchon, Seoul- (진단용(診斷用) X선장치(線裝置)의 관전압(管電壓) 백분율(百分率) 평균오차(平均誤差)에 관한 조사(調査) 연구(硏究))

  • Lim, Han-Young;Oh, Hyun-Joo;Kim, Young-Il
    • Journal of radiological science and technology
    • /
    • v.16 no.2
    • /
    • pp.45-50
    • /
    • 1993
  • In this paper, the PAE of tube voltage of 93 diagnostic X-ray units those are using at the 19 general hospitals and 9 local clinics in the area of Sungnam, Inchun, and Seoul have been surveyed. The results are summarized as following. 1. PAE of tube Voltage 70, 100KV at the 56 (60%) X-ray units were ${\pm}7%$ below, at the 8 units (9%), were ${\pm}7%$ above, and those 29 X-ray units (31%) were ${\pm}7%$ below or above with the 70, 100KV tube Voltage in a unit. 2. PAE ${\pm}7%$ below were 68 X-ray units, at the low tube voltage (70KV), and 76 X-ray units at the high tube Voltage (100KV). 3. For six year-use abofe, used X-ray units were PAE ${\pm}7%$ above, and so, the longer used years the more X-ray units became declined in those performance. 4. PAE of tube Voltage were better efficiency at the large capacity 30 X-ray units than small capacity 10. 5. PAE ${\pm}7%$ abovein were only 8 units among 84 diagnostic X-ray units in the general hospitals.

  • PDF

Experiment of Compressive Strength Enhancement of Circular Concrete Column Confined by Carbon Tubes

  • Hong Won-Kee;Kim Hee-Cheul;Yoon Suk-Han
    • KCI Concrete Journal
    • /
    • v.14 no.4
    • /
    • pp.139-144
    • /
    • 2002
  • Concrete filled FRP tube has lately attracted attention as the member that can substitute the conventional reinforced concrete. Glass fiber and carbon fiber are some of available materials for FRP tube. Carbon tube is filament wound with specified winding angle to meet the appropriate capacity demands. Confinement effect of carbon tube is varied according to winding angle. In this study, a total 4 of large scale circular specimens of 30cm diameter and 60cm height is tested. To estimate the effect of winding angle and thickness of carbon tube on the increased confined compressive strength, the test tube are wound with $\pm45^{\circ}\;and\;\pm30^{\circ}$ with two types of thickness, 2mm and 3mm, respectively. It is shown that effectively increased confined strength and ductility are observed from the specimens with $\pm45^{\circ}$ winding angle than $\pm30^{\circ}$ winding angle. Increasing thickness is not as effective as adjusting winding angle for the confinement of concrete core.

  • PDF

Studies on Changes of Progesterone and $20\alpha$-Dihydroprogesterone Levels in Serum by Progesterone-tube Implantation during Pregnancy in Rats (흰쥐의 번식과정에 있어서 Progesterone-tube 이식이 혈청내 Progesterone과 $20\alpha$-Dihydroprogesterone 수준변화에 미치는 영향)

  • 민관식;오석두;윤창현
    • Korean Journal of Animal Reproduction
    • /
    • v.14 no.4
    • /
    • pp.273-280
    • /
    • 1990
  • This study was conducted to find out the changes of progesterone and 20$\alpha$-dihydroprogesterone(OHP) levels in the serum of female rats by progesterone-tube implantation during late pregnancy. One hundred and twenty rats, 10-13 weeks old, were offered for this experiment. Blood samples were taken from the rats on 18, 20, 21 and 22days of pregnancy. The rats were implanted with silicon tubes filled with pregesterone on day 15 of pregnancy. The progesterone and 20$\alpha$-OHP in serum were assayed by radioimmunoassay. The results obtained are summarized as follows : 1. The progesterone levels in rats of control group showed 126.36$\pm$20.19ng/ml on 18days and gradually decreased to 69.3$\pm$11.9, 29.2$\pm$1.8ng/ml 20 and 21 days. 2. The progesterone levels after progesterone-tube implantation showed 120.1$\pm$8.5, 59.01$\pm$3.1, 85.33$\pm$17.9 and 62.9$\pm$6.1ng/ml on 18, 20, 21 and 22days of pregnancy, respectively. 3. The 20$\alpha$-OHP levels in rats of control group showed 68.5$\pm$8.0ng/ml on 18 days and gradually increased to 139.9$\pm$3.7 and 141.4$\pm$6.7ng/ml on 21 and 22days. 4. The 20$\alpha$-OHP levles after progesterone-tube implantation showed 108.5$\pm$32.7 and 106.4$\pm$10.6ng/ml on 18 and 20days and increased to reach the peak level at 21days(225.01$\pm$9.9ng/ml) and rapidly decreased on 22days(85.9$\pm$10.7ng/ml).

  • PDF

The Image Distortion Analysis of Levin-tube tip by Patient position and Incidence Angle when taking Mobile Chest AP Projection (Mobile Chest AP 검사 시 환자자세와 입사각도에 따른 Levin-tube tip의 영상왜곡 분석)

  • Lee, Jinsoo;Park, Hyonghu
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.7
    • /
    • pp.467-471
    • /
    • 2015
  • This study's purpose is improve image quality to keep accurate tube angle in order to recognize distortion degree conditions by patient's position or tube angle and to provide exact clinical informations when taking chest AP projection for patient which have L-tube in stomach. The experimental equipment was ELMO-T6S by SHIMADZU corporation, then we put L-tube which attached 1 mm gap scales ruler on chest phantom surface. The experiment set by 90 kVp, 4 mAs, 120 cm distance. Each phantom position which changed supine, 30degree, 45degree, 60degree on the table exposured direct, ${\pm}5degree$, ${\pm}10degree$, ${\pm}15degree$ to head and feet directions. As a result, L-tube tip's position was changed by patient's position and tube angle. When patient's position is supine, tip's position change was lower than 30degree, 45degree, 60degree. We have to adjust patient's position or tube angle in order to occur image distortion by fault tube angle when confirming correct position L-tube tip through chest x-ray. Also, Radiological technologist try to make accurate evaluation index for satisfied L-tube insertion.

Evaluation of Tear Film Lipid Layer Thickness Measurements Obtained Using an Ocular Surface Interferometer in Nasolacrimal Duct Obstruction Patients

  • Lee, Sang Min;Chung, Sok Joong;Lew, Helen
    • Korean Journal of Ophthalmology
    • /
    • v.32 no.6
    • /
    • pp.445-450
    • /
    • 2018
  • Purpose: To compare the tear film lipid layer thickness (LLT) between patients with incomplete nasolacrimal duct obstruction (NLDO) and normal controls and to analyze the changes in tear film LLT and blinking pattern after silicone tube intubation in NLDO patients. Methods: We reviewed the medical records of 68 eyes in 52 incomplete NLDO patients who underwent silicone tube intubation from January 2017 to July 2017. The LLT, blinking pattern, and Meibomian gland image were measured with the LipiView II ocular surface interferometer. The Meibomian gland drop-out ratio was measured using the polygon selection tool in the Image J program. Tear meniscus height, which is the other lacrimal indicator, was assessed with spectral-domain optical coherence tomography. Results: Tear meniscus height was significantly decreased after silicone tube intubation (p < 0.01). Preoperative minimum, maximum, and average LLT values were $62.4{\pm}24.0$, $86.7{\pm}17.9$, and $71.7{\pm}23.3nm$, respectively. Significant changes in the minimum, maximum, and average LLT ($74.8{\pm}23.6$, $98.8{\pm}11.0$, and $91.6{\pm}16.1nm$, respectively) were observed after silicone tube intubation (p < 0.001, p = 0.001, and p < 0.001). The partial blinking/total blinking ratio in 20 seconds and the Meibomian gland drop-out ratio showed no significant change after silicone tube intubation. Conclusions: Overall, the LLT was increased after silicone tube intubation. Silicone tube intubation may be helpful in maintaining LLT with a normalized of amount of tears.

Relationship between Germ Tube Formation, Adherence to Human Buccal Epithelial Cells and Virulence of Candida albicans (Candida albicans의 상피세포에 대한 부착능과 병원성과의 상관관계에 관한 연구)

  • Koh, Choon-Myung
    • The Journal of the Korean Society for Microbiology
    • /
    • v.21 no.4
    • /
    • pp.407-415
    • /
    • 1986
  • This study investigated whether a correlation exists between environmental physical and biochemical factors and adherence of Candida albicans to human buccal epithelial cells by using normal and UV-irradiated strains. The results were as follows: 1. The percentage of germ tube forming activities of normal Candida albicans was 91.5% and UV-irradiated Candida albicans was 15.0%. The $LD_{50}$ of normal strains in mice were $1.0{\times}10\;cells/ml$, but could not be observed in the UV-irradiated strains even with $1.0{\times}10\;cells/ml$. It demonstrated that the virulence is decreased in the UV-irradiated strain. 2. The adherence of normal Candida albicans to human buccal epithelial cells($166{\pm}29{\sim}207{\pm}17\;cells$/100 epithelial cells) was significantly greater than UV-irradiated Candida albicans($99{\pm}21{\sim}131{\pm}25\;cells$/100 epithelial cells). 3. Candida albicans cultured at $37^{\circ}C$ adhered to buccal epithelial cells($166{\pm}16{\sim}207{\pm}17\;cells$/100 epithelial cells) in greater numbers than cultured at $25^{\circ}C$($80{\pm}15{\sim}143{\pm}22\;cells$/100 epithelial cells). 4. On comparison of the adherence of viable and nonviable(heat-killed) Candida albicans to human buccal epithelial cells, the nonviable Candida albicans demonstrated poorer adherence than viable Candida albicans. 5. Adherence in vitro of Candida albicans to human epithelial cells appeared to be effected by the pH. The adherence ability was maximum increased at pH 7.0($187{\pm}22\;cells$/100 epithelial cells) other than experimental pH. 6. The adherence was proportional to the incubation time and the Candida cell concentration in the suspension. 7. A strong correlation was shown between germ tube forming activity and increased adherence of Candida albicans to human epithelial cells, indicating that germ tube forming activity were responsible for candidal virulence.

  • PDF

A study on The Applying of Training Program to Facilitate Deglution -On spontaneous intracerebral hemorrhage patients with nasogastric tube- (자발성 뇌내출혈 환자의 비위관 제거시기에 관한 연구)

  • Kim, Myung Hee;Kim, Young Hee;Kim, Young Mi;Ju, Young Hee;Lee, Yun Mi;Chung, Eun Hae
    • Korean Journal of Adult Nursing
    • /
    • v.13 no.1
    • /
    • pp.136-147
    • /
    • 2001
  • Dysphagia is common and serious problem in intracerebral hemorrhage patients. Nasogastric-tube intubation is an important method for dysphagic patients who have an intracerebral hemorrhage. But many discomforts develope in patients with a nasogastric-tube. Therefore, it is necessary to decide when to remove the tube and as early as possible. The purpose of this study is to decide the applying time of training program to facilitate deglution for dysphagic patients who have intracerebral hemorrhage. Among the 343 patients with intracerebral hemorrhage who had been admitted to P-university hospital from April, 1994 to December, 1998, the medical record of the 110 patients with nasogastric tube were reviewed retrospectively. Results from the study were as follows: 1. Nasogastric tube insert duration of improved patients was a mean of 23.2 days 2. When a L-tube was inserted and removed, the L.O.C. of improved patients was $2.6{\pm}0.8$(in the midst of stupor or a semicoma),$1.9{\pm}0.5$(close to drowsy), respectively. This was signifcantly different(P=0.000). 3. When a L-tube was inserted and removed, GCS of improved patients was $9.3{\pm}2.9$, $12.1{\pm}2.2$ respectively. This was significantly different (P=0.000). 4. The duration of nasogastric tube insertion was the longest when in a stupor(L.O.C), 6~8 points(GCS).

  • PDF

Comparison of Sampling Methods for Determining Airborne Mixture of Organic Solvents (공기중 유기용제 혼합물 측정방법의 비교연구)

  • Chun, Mee Hye;Paik, Nam Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.1 no.1
    • /
    • pp.16-28
    • /
    • 1991
  • A study on comparison of standard charcoal tube method, infrared gas analyzer, and detector tube method were conducted. Measurements were performed simultaneously at same sampling points in an air chamber containing benzene, toluene and xylene vapors. Charcoal tube samles were collected at sampling flowrates of 0.05, 0.2, 0.5, and 1.0 1pm. Results are as follows : 1. Coefficients of variation of results with charcoal tube method for bezene, toluene and xylene mixture vapor were 14.34 % in benzene(0.28-11.12 ppm), 9.20 % in toluene (2.68-135.09 ppm) and 10.21 % in xylene (2.56-82.64 ppm), respectively. 2. Results of infrared gas analyzer in mixture air were non-specific on benzene and toluene. Ratio of results of infrared gas analyzer to those of charcoal tube on benzene, toluene and xylene were 696.4 %, 30.3 % and 36.6 %, respectively. 3. Ratio of responses of detector tubes to those of charcoal tube were 49.4 % in benzene, 22.1 % in toluene and 223.9 % in xylene. Xylene detector tube were interfered by toluene greately. 4. Collection efficiencies of charcoal tubes at low concentraton(benzene : 1 ppm, toluene : 10 ppm, xylene : 10 ppm) were stable on various flowrate from 0.05 to 1.0 1pm, but at high concentrations the efficiency decreased at high flowrate above 0.5 1pm. 5. Within the saturation capacity of charcoal, collection effiency decreased at 0.5-1.0 1pm. Smpling feowrates of 0.05-0.20 1pm were appropriate for sampling organic vapors.

  • PDF