• 제목/요약/키워드: PM tube

검색결과 405건 처리시간 0.16초

복부(腹部) 단순X선검사시(單純X線檢査時) 피검자(被檢者)의 피폭선량(被曝線量)에 대(對)한 연구(硏究) (A Study of the Medical Exposure Dose in Abdomen A-P X-ray Examination)

  • 김창균
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제17권1호
    • /
    • pp.49-54
    • /
    • 1994
  • This study was conducted to find out the medical exposure dose in simple abdomen A-P projection of adults, based on the 87 hospitals located in Seoul. As the results, the following conclusions have been reached; 1. 88.5 % of the surveyed hospitals had the use of $65\;kVp{\sim}79\;kVp(M{\pm}SD:71.45{\pm}4.73\;kVp)$ as tube voltage. 2. 87.35 % of the surveyed hospitals had the use of $50\;mAs{\sim}89\;mAs(M{\pm}SD:64.31{\pm}16.21\;mAs)$ as the amount of current. 3. Shallow doses ranged from 2.00 mSv to 4.99 mSv($M{\pm}SD:3.81{\pm}1.01\;mSv$) in 80.46 % of the surveyed hospitals. 4. Exposure dose was directly depended on the tube voltage or the amount of currents.

  • PDF

비히스테리자화에 의한 강관의 탈자 기법 연구 (A Study on Demagnetization Technique of a Steel Tube using an Anhysteretic Magnetization)

  • 김영학;양창섭;신광호
    • 한국군사과학기술학회지
    • /
    • 제12권1호
    • /
    • pp.24-28
    • /
    • 2009
  • In this study, we investigated whether the anhysteretic demagnetization process would be applicable to remove a complicated magnetization of a steel tube as a part of the experimental earlier study for a deperming of naval vessel. The magnetic tube used in this study was a 10cm-long and 1cm-diameter steel tube, and magnetized with a E-shape ferrite core to form a nonuniform magnetization in it. In the anhysteretic demagnetization process, a dc magnetic field applied along the longitudinal direction of the tube decreased from ${\pm}$3kA/m to zero-field with the step of ${\pm}$300A/m. At the same time, an ac bias magnetic field with the frequency of 60Hz and the field intensity of 300A/m was excited along the circumstantial direction of the tube. It was found that the anhysteretic process was useful to demagnetize a small-object like a steel tube from the experimental results showing the residual magnetization reduced over 90%.

Is Computerized Tomography Angiographic Surveillance Valuable for Prevention of Tracheoinnominate Artery Fistula, a Life-Threatening Complication after Tracheostomy?

  • Sung, Jae-Hoon;Kim, Il-Sup;Yang, Seung-Ho;Hong, Jae-Taek;Son, Byung-Chul;Lee, Sang-Won
    • Journal of Korean Neurosurgical Society
    • /
    • 제49권2호
    • /
    • pp.107-111
    • /
    • 2011
  • Objective : The aim of this study was to evaluate the utility of volume-rendered helical computerized tomography (CT) angiography focusing tracheostomy tube and innominate artery for prevention of tracheoinnominate artery fistula. Methods : The authors retrospectively analyzed 22 patients with tracheostomy who had checked CT angiography. To evaluate the relationship between tracheostomy tube and innominate artery, we divided into three categories. First proximal tube position based on cervical vertebra, named "tracheostomy tube departure level (TTDL)". Second, distal tube position and course of innominate artery, named "tracheostomy tube-innominate artery configuration (TTIC)". Third, the gap between the tube and innominate artery, named "tracheostomy tube to innominate artery gap (TTIG)". The TTDL/TTIC and TTIG are based on 3-dimensional (3D) reconstruction around tracheostomy and enhanced axial slices of upper chest, respectively. Results : First, mean TTDL was $6.8{\pm}0.6$. Five cases (23%) were lower than C7 vertebra. Second, TTIC were remote to innominate artery (2 cases; 9.1 %), matched with it (14 cases; 63.6%) or crossed it (6 cases; 27.3%). Only 9% of cases were definitely free from innominate artery injury. Third, average TTIG was $4.3{\pm}4.6$ mm. Surprisingly, in 6 cases (27.3%), innominate artery, trachea wall and tracheostomy tube were tightly attached all together, thus have much higher probability of erosion. Conclusion : If low TTDL, match or crossing type TTIC with reverse-L shaped innominate artery, small trachea and thin TTIG are accompanied all together, we may seriously consider early plugging and tube removal.

경관급식을 공급한 중환자실 환자의 영양상태 평가 (Nutritional Assessment of ICU Inpatients with Tube Feeding)

  • 김유진;서정숙
    • 대한영양사협회학술지
    • /
    • 제21권1호
    • /
    • pp.11-24
    • /
    • 2015
  • This study investigated the general status of tube feeding for intensive care unit (ICU) inpatients and evaluated the consequent nutritional status of patients. This study was approved by the Institutional Review Board (IRB) of a general hospital located in Daegu metropolitan city. The subjects of this study were 80 adult patients who had been admitted to the ICU of a hospital, received fed tube feeding, and then been discharged. The differences in nutrition screening indicators, including percentage ideal body weight (PIBW), serum albumin, hemoglobin, total lymphocyte count, and total cholesterol, before and after tube feeding according to body mass index (BMI) or nutrient feeding levels were investigated. The ratios of actually provided amounts to calorie and protein requirements of patients were $72.8{\pm}15.8%$ and $72.6{\pm}19.8%$, respectively. The change in PIBW before and after tube feeding was significantly different among the BMI groups (P<0.01). The change in hemoglobin concentration before and after tube feeding was also significantly different among the BMI groups (P<0.01). When subjects were divided into three groups (<60%, 60~79%, ${\geq}80%$) according to the ratio of actually provided calories to required calories, there was no significant difference in nutrition screening indicators before and after tube feeding. When the subjects were divided into three groups (<60%, 60~79%, ${\geq}80%$) according to the ratio of actually provided protein to required protein, serum albumin concentration showed a significant difference among the groups before and after tube feeding (P<0.05). Therefore, an intensive nutrition intervention program would be needed for the nutritional improvement of ICU inpatients receiving tube feeding.

INTESTINAL WALL PERMEABILITY STUDY OF RANITIDINE IN DOGS

  • Kim, Ok-Nam;Gordon L. Amidon
    • 한국응용약물학회:학술대회논문집
    • /
    • 한국응용약물학회 1996년도 춘계학술대회
    • /
    • pp.273-273
    • /
    • 1996
  • Recently a novel in vivo approach in dogs, using a regional segmental intestinal perfusion technique, has been developed. The perfusion tube consists of a highly sophisticated multichannel tube with two inflatable occluding balloons, which are placed in 10cm apart. The tube was introduced orally from the stomach through the upper jejunum under the guidance of solid-state pH meter. In the present study, four healthy dogs were infused in the proximal jejunum on two periods. The two perfusion experiments used the same flow rate, 2 $m\ell$/min, and the same perfusion solution to determine the intrasubject variability. The mean (${\pm}$ S. E.) fractions of ranitidine absorbed calculated from the perfusion data were 21.32${\pm}$2.01% (n=3) (1st period), 27.88 ${\pm}$ 17.54% (n=4) (2nd period), respectively. The effective permeabilities (Peffs${\times}$10$\^$4/) of ranitidine were 1.51${\pm}$0.47cm/sec (n=3) (1st period), 1.50 ${\pm}$ 0.31 cm/sec (n=4) (2nd period), respectively. The pH and osmolarity of perfusion solution were 7.50 ${\pm}$ 0.03 and 300 ${\pm}$ 0.06 mOsm/L, There was no significant intrasubject variation. Mixing equilibrium (steady-state) was reached at about 50 min. l-Phenylalanine was absorbed almost completely. Intrinsic intestinal wall permeability of ranitidine showed low permeable characteristics, suggesting permeability-limited absorption. The absorption of 1-phenylalanine, an actively transported nutrient, was not inhibited by ranitidine. The low intestinal membrane permeability is one of the important factors responsible for the variable oral absorption of ranitidine. Supported by FDA Grant FD01462-04 and KOSEF Grant.

  • PDF

미소해칭 전열관의 젖음률에 대한 실험적 상관식 (Experimental Correlation of Wettability for Micro-scale Hatched Tubes)

  • 김진경;박찬우;이경엽;강용태
    • 설비공학논문집
    • /
    • 제15권1호
    • /
    • pp.19-24
    • /
    • 2003
  • The objectives of this paper are to develop a new method of wettability mea-surement and to study the effect of surface roughness on the wettability in a $H_2O$/LiBr falling film absorber. Two absorber tubes with micro-scale roughness and a bare tube are tested in a falling film absorber installed in a test rig. Inlet solution temperature, concentration and mass flow rate are considered as key parameters. A new method is proposed to estimate the wettability of a tube by measuring a minimum mass flow rate to wet the tube completely. The wettability for the structured surfaces was higher than that for the bare tube. The wettability decreased linearly along the vertical location. The wettability increased with increasing the solution temperature and the solution mass flow rate. The experimental correlations of the wettability for the bare and the micro-hatched tubes were developed with error bands of$\pm20%\;and\;\pm10%$, respectively. This work can be used in the design of absorbers with micro-scale roughness.

기상응축 열교환을 이용한 고정밀 등온 가열로 개발 (Development of Heat-treatment Furnace with Maximum Uniform Zone using Gas-phase Condensing Heat Exchange)

  • 홍현선;공만식;강환국
    • 열처리공학회지
    • /
    • 제22권3호
    • /
    • pp.162-168
    • /
    • 2009
  • A horizontal tube furnace with a wide uniform-temperature zone was developed using isothermal characteristics of a heat pipe. The heat pipe heating system consists of a concentric annular shaped stainless-steel container, sodium as a working fluid and a screen mesh wick structure. The performance test of the heat pipe revealed that temperature changes along seven consecutive positions of the heat pipe outer wall were less than${\pm}0.1^{\circ}C$, thereby ensuring the high isothermal property. The isothermal property of the heat pipe-adapted tube fumace was investigated and compared to a conventional non-heat pipe type tube furnace. The temperature distribution measurement showed that the uniform temperature zone, in which temperature change is less than${\pm}$1$^{\circ}$C, of the heat pipe employed tube furnace system was about three times longer compared to the conventional tube furnace system.

돌기가 있는 거친 표면에서의 관내 마찰 및 열전달 특성 (Friction and Heat Transfer Characteristics of Enhanced Tubes with Internal Ribs)

  • 박종익;정진희;이영수;강용태
    • 설비공학논문집
    • /
    • 제17권4호
    • /
    • pp.318-324
    • /
    • 2005
  • The objectives of this paper are to study the heat transfer characteristics on enhanced surfaces, to develop experimental correlations of friction factor and Nusselt number, and to provide a guideline for optimum operation conditions at low temperature boiling for practical refrigeration applications. The working fluid (water, EG $30\%$) flows inside the enhanced tube and R134a boils on the outer surface. Two different types of Turbo-B tubes (Tube I and Tube II) are tested in the present study. The results show that Tube I gives a higher heat transfer coefficient with higher friction factor than Tube II. The present study provided experimental correlations for friction factor and heat transfer coefficient with error bands of ${\pm}5\%\;and\;{\pm}\;15\%$, respectively.

나선코일튜브내의 강제대류 열전달에 관한 연구 (Study on forced convective heat transfer in helically ceiled tubes)

  • 한규일;박종운;임태우
    • 설비공학논문집
    • /
    • 제10권3호
    • /
    • pp.282-291
    • /
    • 1998
  • Heat transfer performance are studied for the turbulent flow of water in 3 smooth tube coils having ratios of coil to tube diameter of 16, 21 and 27, and a corrugated-coiled tube having a ratio of coil to tube diameter of 29, for Reynolds numbers from 8000 to 60000 and is also compared with the limited results available to data. The experiments are carried out for the fully developed turbulent flow of water in tube coils under the condition of uniform heat flux. This work is limited 0 tube coils of R/a between 10 and 30. The tube having a ratio of coil to tube diameter of 27 among the 3 smooth tube coils shows the best heat transfer performance. The performance of coiled tube best transfer performance. The performance of coiled tube with a similar curvature ratio is better for a corrugated-coiled tube(R/a=17) than for a smooth coiled tube(R/a=16). An empirical relation which correlates most of the data within $\pm$25% was also developed. Test result shows that the Nusselt number is found to be affected by a secondary flow due to curvature.

  • PDF

Comparisons between the KKU-Model and Conventional Rectal Tubes as Markers for Checking Rectal Doses during Intracavitary Brachytherapy of Cervical Cancer

  • Padoongcharoen, Prawat;Krusun, Srichai;Palusuk, Voranipit;Pesee, Montien;Supaadirek, Chunsri;Thamronganantasakul, Komsan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권15호
    • /
    • pp.6115-6120
    • /
    • 2014
  • Background: To compare the KKU-model rectal tube (KKU-tube) and the conventional rectal tube (CRT) for checking rectal doses during high-dose-rate intracavitary brachytherapy (HDR-ICBT) of cervical cancer. Materials and Methods: Between February 2010 and January 2011, thirty -two patients with cervical cancer were enrolled and treated with external beam radiotherapy (EBRT) and intracavitary brachytherapy (ICBT). The KKU-tube and CRT were applied intrarectally in the same patients at alternate sessions as references for calculation of rectal doses during ICBT. The gold standard references of rectum anatomical markers which are most proximal to radiation sources were anterior rectal walls (ARW) adjacent to the uterine cervix demonstrated by barium sulfate suspension enema. The calculated rectal doses derived from actual anterior rectal walls, CRT and the anterior surfaces of the KKU-tubes were compared by using the paired t-test. The pain caused by insertion of each type of rectal tube was assessed by the visual analogue scale (VAS). Results: The mean dose of CRT was lower than the mean dose of ARW ($Dmean_0-Dmean_1$) by $80.55{\pm}47.33cGy$ (p-value <0.05). The mean dose of the KKU-tube was lower than the mean dose of ARW ($Dmean_0-Dmean_2$) by $30.82{\pm}24.20cGy$ (p-value <0.05). The mean dose difference [($Dmean_0-Dmean_1$)-($Dmean_0-Dmean_2$)] was $49.72{\pm}51.60cGy$, which was statistically significant between 42.32 cGy -57.13 cGy with the t-value of 13.24 (p-value <0.05). The maximum rectal dose by using CRT was higher than the KKU-tube as much as 75.26 cGy and statistically significant with the t-score of 7.55 (p-value <0.05). The mean doses at the anterior rectal wall while using the CRTs and the KKU-tubes were not significantly different (p-value=0.09). The mean pain score during insertion of the CRT was significantly higher than the KKU-tube by a t-score of 6.15 (p-value <0.05) Conclusions: The KKU-model rectal tube was found to be an easily producible, applicable and reliable instrument as a reference for evaluating the rectal dose during ICBT of cervical cancer without negative effects on the patients.