• Title/Summary/Keyword: PM machine

Search Result 511, Processing Time 0.023 seconds

Role of Post Weld Treatment Methods in the Improvement of Fatigue Life for T-type Welded Structures Made by SM 50A Steel (SM 50A 강으로 제작된 T-형 용접형상의 용접후처리 방법이 피로수명 증가에 작용하는 역할)

  • Han, Chang-Wan;Lee, Jae-Hoon;Song, Jun-Hyouk;Lee, Hyun-Woo;Park, Seong-Hun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.3
    • /
    • pp.307-312
    • /
    • 2012
  • This study aims to investigate the effect of the post weld treatments on the fatigue life of T-type welded structure made by a SM50A steel material, generally used for excavators, because changes in the geometry, material and surface properties of welded regions affect the fatigue life of welded structures. T-type test specimens were prepared by the CO2 welding of rolled steel plates (SM50A steel) with a thickness of 10 mm at a welding speed of 30 cm/min and these Ttype welded specimens were further treated by UIT (Ultrasonic Impact Treatment) and/or toegrinding post welding treatment methods. In order to investigate improvements on the fatigue life of the samples. 3-point bending fatigue tests were conducted with a stress ratio of R=0.1 under a cyclic loading environment at a frequency of 5 Hz, via a hydraulic fatigue testing machine (${\pm}100\;kN$, MTS 809). The tests were performed at room temperature. The fatigue life of UIT specimens was approximately 25 times longer than that of as-welded specimens at a stress amplitude of 281 MPa, while toe-grinding specimens exhibited 4.15 times longer fatigue life. The current results could provide important guidelines to determine the proper post weld treatment methodologies of T-type welded parts for excavators with a satisfactory fatigue life although under severe operating conditions.

Studies on the Exhaust Gas Characteristics of the Vehicle Diesel according to the Test Mode and Ambient Temperature (시험모드 및 대기온도에 따른 경유자동차의 배출가스 특성에 관한 연구)

  • Lee, Jung-Cheon;Jeon, Cheol-Hwan;Kim, Ki-Ho;Oh, Sang-Gi;Park, An-Young
    • Journal of Power System Engineering
    • /
    • v.20 no.6
    • /
    • pp.93-98
    • /
    • 2016
  • Environmental problems are issued throughout all over the world and which are needed the strength management. In case of the diesel cars are also being developing and studying continuously about various after-treatments device such as EGR, LNT, SCR, DPF and DOC etc. which are used for decreasing $NO_X$ and PM. The air temperature goes up to $39^{\circ}C$ in summer and goes down to $-20^{\circ}C$ in winter because of the location. These changing of the temperature can effect to the engine and harmful exhaust gas discharged and it seems to make the increase - decrease different. The result of the evaluate while changing between the test-mode and the air temperature, which expresses that WLTC-mode is 2.2 times and FTP_75 mode is 4.1~6 times increase to the comparison NEDC-mode of the current regulation. The exhaust characteristic of $NO_X$ by the changing temperature increases in the low temperature and 4.3 times in $14^{\circ}C$ and 21.3 times in $-7^{\circ}C$ with maximum when it compares to $23^{\circ}C$. The fuel efficiency of the different weight car and engine with same data is about 5.7 % in maximum.

A Potential Biological Weed Control by Golden Apple Snail(Pomacea canaliculata) in Wet Hill Seeded Rice with Iron-coated Seeds (벼 무논점파(철분코팅종자)재배에서 친환경 잡초관리를 위한 왕우렁이 이용 기술개발)

  • Park, Kwang-Ho
    • Korean Journal of Weed Science
    • /
    • v.32 no.3
    • /
    • pp.273-279
    • /
    • 2012
  • This experiment was conducted to determine a potential effective biological weed control and/or rice young seedling injury by golden apple snail (Pomacea canaliculata) at wet hill seeded rice field. The rice seeds used were treated by iron-coating. The efficacy of weed control as affected by golden apple snail has been tested with twice applications of young golden apple snails of 12 kg (24,000 young snails, $0.5g{\pm}10%$ per young snail, 30~40 days after hatching) per ha at the same day after harrowing and applied with rate of 10 kg (20,000 young snails) per ha at 15days after seeding, respectively. The comparison of this experiment was of the conventional machine transplanted rice paddy field in terms of weed control and rice plant injury as a visual grade. The weed efficacy was of 100% similar with the conventional paddy field which was applied by systematic herbicides of pre-emergence and post-emergence chemical herbicides and there was 1~3% significant rice young seedling injury but no yield losses and grain quality due to the input of golden apple snail.

Development and Performance Evaluation of Multiple Sensor for Groundwater Quality Monitoring and Remote Control System using IoT (IoT기반 지하수 수질모니터링을 위한 다중센서모듈 개발 및 성능평가)

  • Chang, Hyunjin;Moon, Boram;Yoon, Seunggyun;Jin, Taeseok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.10
    • /
    • pp.1957-1963
    • /
    • 2017
  • This paper has proposed a new-type groundwater auto-monitoring system based on Multi-Sensor Device. The system adopted Multi-Sensor Device as host computer of data acquisition, used Windows Mobile which was prevalent operation system of Multi-Sensor Device. It adopted serial port CAN and RS485 as the communication interface between goundwater sensor Device and monitor host machine and utilized serial-linked multi-sensor design to measure effectively according to the depth of groundwater. We present a design for a groundwater monitoring system based on a network of wirelessly linked sensors. The proposed solution will enable groundwater researchers and decision makers to have quick access to the groundwater data with less effort and cost. Though our design is initially meant for groundwater monitoring, it can be easily adapted to other fields of environmental monitoring.

EFFECT OF SALIVARY CONTAMINATION OF TEETH ON MICROTENSILE BOND STRENGTH OF VAR10US DENTIN BONDING SYSTEMS. (타액에 의한 오염이 상아질 접착제의 미세전단결합강도에 미치는 영향)

  • Choi, Kyoung-Kyu;Ryu, Gil-Joo
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.3
    • /
    • pp.203-208
    • /
    • 2003
  • The purpose of this study was to evaluate the effect of salivary contamination of teeth on bonding efficacy of self-priming and self-etching DBSs. The materials used were Single Bond(SB, self-priming system, 3M), Unifil Bond(UB, self-etching system, GC), and Scotchbond Multi-Purpose Plus(SM, 3M) as control. Forty five human molars randomly allocated to three groups as dentin bonding systems tested and embedded in epoxy resin. Then the specimens were wet-ground to expose flat buccal enamel surface or flat occlusal dentin surface and cut bucco-lingually to form two halves with slow speed diamond saw. One of them was used under non-contamination, other under contamination with saliva. The bonding procedure was according to the manufacturer's directions and resin composite(Z-100, 3M Dental Products, St. Paul, MN) was built-up on the bonded surface 5mm high. The specimens were ground carefully at the enamel-composite interface with fine finishing round diamond bur to create an hour-glass shape yielding bonded surface areas of $1.5{\pm}0.1\textrm{mm}^2$. The specimens were bonded to the modified microtensile testing apparatus with cyanoacrylate, attached to the universal testing machine and stressed in tension at a CHS of 1mm/min. The tensile force at failure was recorded and converted to a tensile stress(MPa). Mean values and standard deviations of the bond strength are listed in table. One-way ANOVA was used to determine significant difference at the 95% level. The bond strength of SBMP and SB were not affected by salivary contamination, but that of UB was significantly affected by salivary contamination. These results indicate that DBSs with total etch technique seems less likely affected by salivary contamination in bonding procedure.

The Effects of Laundering Conditions on Calcium Deposition on the Fabric (세척조건이 직물에의 Calcium 침착에 미치는 영향)

  • Moon Young Ae;Kahng He Won;Kim Sung Reon
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.5 no.1
    • /
    • pp.9-14
    • /
    • 1981
  • The influence of laundering conditions on calcium deposition on the fabric was studied by repeated laundering the cotton fabric with soap in the hard water of 200 P.P.M. $CaCO_3$. The experimental variables were: 1) soap concentrations ($0.06\%$, $0.13\%$, $0.25\%$), 2) water contents in the fabric after hydroextraction. ($65\%$, $150\%$, $315\%$), 3) builders (Na-EDTA, sodium carbonate, sodium metasilicate), 4) washing cycle (5, 10, 15, 20 cycles). The fabric was washed for 15 minutes at $23\pm1^{\circ}C$ in a washing machine (Model; Gold Star Wp-2005) under the similar conditions with those of home laundering, and rinsed 5 times for 5 minutes. The amount of calcium deposits on the fabric was determined by the EDTA-Back titration method described by Wasserman and Basch. Results of this study were follows: 1) The amount of calcium deposits on the fabric increased with increasing wash cycles. 2) During the rinsing process, residual calcium content on the fabric increased with water content in the fabric after hydroextraction. 3) The amount of calcium deposits on the fabric decreased with the increasing soap concentration above the equivalent amount of calcium ion content in the water. 4) Sequestering agents and alkaline builders influenced the amount of calcium deposits on the fabric. The amount of calcium deposits on the fabric was in the order of sodium metasilicate, sodium carbonate, nonbuilder, and EDTA.

  • PDF

Assessment and Applications of Multi-Degradable Polyethylene Films as Packaging Materials

  • Chung, Myong-Soo;Lee, Wang-Hyun;You, Young-Sun;Kim, Hye-Young;Park, Ki-Moon;Lee, Sun-Young
    • Food Science and Biotechnology
    • /
    • v.15 no.1
    • /
    • pp.5-12
    • /
    • 2006
  • Degradation performance of environmentally friendly plastics that can be disintegrated by combination of sunlight, microbes in soil, and heat produced in landfills was evaluated for use in industries. Two multi-degradable master batches (MCC-101 and MCC-102 were manufactured, separately mixed with polyethylene using film molding machine to produce 0.025 mm thick films, and exposed to sunlight, microbes, and heat. Low- and high-density polyethylene (LDPE and HDPE) films containing MCC-101 and MCC-102 became unfunctional by increasing severe cleavage at the surface and showed high reduction in elongation after 40 days of exposure to ultraviolet light. LDPE and HDPE films showed significant physical degradation after 100 and 120 days, respectively, of incubation at $68{\pm}2^{\circ}C$. SEM images of films cultured in mixed mold spore suspension at $30^{\circ}C$ and 85% humidity for 30 days revealed accelerated biodegradation on film surfaces by the action of microbes. LDPE films containing MCC-l01 showed absorption of carbonyls, photo-sensitive sites, at $1710\;cm${-1}$ when exposed to light for 40 days, whereas those not exposed to ultraviolet light showed no absorption at the same frequency. MCC-101-based LDPE films showed much lower $M_w$ distribution after exposure to UV than its counterpart, due to agents accelerating photo-degradation contained in MCC-101.

Shape Optimization of an Active Micro-Mixer for Improving Mixing Efficiency (혼합 효율 향상을 위한 마이크로 동적 믹서의 형상최적화)

  • Park, Jae-Yong;Kim, Sang-Rak;Lee, Won-Gu;Yoo, Jin-Sik;Kim, Young-Dae;Maeng, Joo-Seung;Han, Seog-Young
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.16 no.6
    • /
    • pp.146-152
    • /
    • 2007
  • An active micro-mixer, which was composed of an oscillating micro-stirrer in the microchannel to provide rapid, effective mixing at high flow, rates was analyzed. The effects of molecular diffusion and disturbance by the stirrer were considered with regard to two types of mixer models: the simple straight microchannel and microchannel with an oscillating stirrer. Two types of mixer models were studied by analyzing mixing behaviors such as their interaction after the stirrer. The mixing was calculated by Lattice Boltzmann methods using the D2Q9 model. In this study, the time-averaged mixing index formula was used to estimate the mixing performance of time-dependent flow. The mixing indices of the two models compared. From the results, it was found that the mixer with an oscillating stirrer was much more enhanced and stabilized. Therefore, an optimum design for a dynamic micro-mixer with an oscillating stirrer was performed using Taguchi method in order to obtain a robust solution. The design parameters were established as the frequency, the length and the angle of the stirrer and the optimal values were determined to be 2, 0.8D and ${\pm}75^{\circ}$, respectively. It was found that the mixing index of the optimal design increased 80.72% compared with that of the original design.

Approximate Optimization of an Active Micro-Mixer (능동형 미소혼합기의 근사최적화)

  • Park, Jae-Yong;Kim, Sang-Rak;Yoo, Jin-Sik;Lim, Min-Gyu;Kim, Young-Dae;Han, Seog-Young;Maeng, Joo-Seung
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.17 no.5
    • /
    • pp.95-100
    • /
    • 2008
  • An active micro-mixer, which is composed of an oscillating micro-stirrer in the micro-channel to provide effective mixing was optimized. The effects of molecular diffusion and disturbance by the stirrer were considered with regard to two types of mixer models: the simple straight micro-channel and micro-channel with an oscillating stirrer. Two types of mixer models were studied by analyzing mixing behaviors such as their interaction after the stirrer. The mixing was calculated by Lattice Boltzmann methods using the D2Q9 model. In this study, the time-averaged mixing index formula was used to estimate the mixing performance of time-dependent flow. The mixing indices of the two models were compared. From the results, it was found that the mixer with an oscillating stirrer was much more enhanced and stabilized. Therefore, an approximate optimization of an active micro-mixer with an oscillating stirrer was performed using Kriging method with OLHD(Optimal Latin Hypercube Design) in order to determine the optimal design variables. The design parameters were established as the frequency, the length and the angle of the stirrer. The optimal values were obtained as 1.0346, 0.66D and $\pm45^{\circ}$, respectively. It was found that the mixing index of the optimal design increased by 88.72% compared with that of the original design.

THE STUDY OF PATIENT EXPOSURE AND PROTECTION FROM DENTAL RADIOGRAPHY (치과 X선 촬영에 있어서 환자에 대한 피폭과 방어에 관한 연구)

  • Park T. W.
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.9 no.1
    • /
    • pp.25-31
    • /
    • 1979
  • The utilization of x-ray for diagnosis and examination is increasing by about 5-15% every year, therefore, it would be mandatory to protect the patients from exposures and so, studies in this field are performed even now. In dental field, the area of irradiation is limited any to the head and neck area, but the irradiated angle is varied following the objected tooth, so the adjacent structures lens and thyroid gland would be fragile to radiation. And the scattered radiation is one of the complicated problems in the protection because of specificity of dental x-ray and its object structures. The author, by using TLD (Thermo luminescent Dosimeter; Teledyne Isotopes-Model 7300, Element; TLD 200(CaF₂:Dy) and Capintec(Capintec Model 192, PM-30 Diagnostic chamber 28㎖ active volume), tried a measurement of air dose distribution of the scattered radiation and the irradiated dose of lens and thyroid gland under the condition of taking the film on the left maxillary molar. The results were as follows: 1. The half value layer of adapted dental x-ray machine was measured, and is 1.44㎜ Al. 2. The time of irradiation on the left maxillary molar in the Alderson Rando Phantom, the measured doses of left and right lens, and thyroid gland were 8,9mR, 1,2mR and 2,8mR. Under the same conditions, the scattered radiation at the distance of 1 meter from the phantom were 84 μR at the front side, 11μR at the back side, 18μR at the right side and 72μR at the left side. 3. Under the same conditions, the dose showed higher value by about 5% in the presence of object(phantom) than in the case of absence.

  • PDF