• 제목/요약/키워드: PM loss

검색결과 1,281건 처리시간 0.034초

Seasonal Acclimatization in Summer versus Winter to Changes in the Sweating Response during Passive Heating in Korean Young Adult Men

  • Lee, Jeong-Beom;Kim, Tae-Wook;Min, Young-Ki;Yang, Hun-Mo
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제19권1호
    • /
    • pp.9-14
    • /
    • 2015
  • We investigated the sweating response during passive heating (partial submersion up to the umbilical line in $42{\pm}0.5^{\circ}C$ water, 30 min) after summer and winter seasonal acclimatization (SA). Testing was performed in July during the summer, 2011 [summer-SA; temp, $25.6{\pm}1.8^{\circ}C;$ relative humidity (RH), $82.1{\pm}8.2%$] and in January during the winter, 2012 (winter-SA; temp, $-2.7{\pm}2.9^{\circ};$ RH, $65.0{\pm}13.1%$) in Cheonan ($126^{\circ}52^{\prime}N$, 33.38'E), Republic of Korea. All experiments were carried out in an automated climatic chamber (temp, $25.0{\pm}0.5^{\circ}C$: RH, $60.0{\pm}3.0%$). Fifteen healthy men (age, $23.4{\pm}2.5$ years; height, $175.0{\pm}5.9cm;$ weight, $65.3{\pm}6.1kg$) participated in the study. Local sweat onset time was delayed during winter-SA compared to that after summer-SA (p<0.001). Local sweat volume, whole body sweat volume, and evaporative loss volume decreased significantly after winter-SA compared to those after summer-SA (p<0.001). Changes in basal metabolic rate increased significantly after winter-SA (p<0.001), and tympanic temperature and mean body temperature were significantly lower after summer-SA (p<0.05). In conclusion, central sudomotor acitivity becomes sensitive to summer-SA and blunt to winter-SA in Rebubic of Korea. These results suggest that the body adjusts its temperature by economically controlling the sweating rate but does not lower the thermal dissipation rate through a more effective evaporation scheme after summer-SA than that after winter-SA.

Minimally Invasive Surgery without Decompression for Hepatocellular Carcinoma Spinal Metastasis with Epidural Spinal Cord Compression Grade 2

  • Jung, Jong-myung;Chung, Chun Kee;Kim, Chi Heon;Yang, Seung Heon
    • Journal of Korean Neurosurgical Society
    • /
    • 제62권4호
    • /
    • pp.467-475
    • /
    • 2019
  • Objective : There is a lack of knowledge regarding whether decompression is necessary in treating patients with epidural spinal cord compression (ESCC) grade 2. The purpose of this study was to compare the outcomes of minimally invasive surgery (MIS) without decompression and conventional open surgery (palliative laminectomy) for patients with hepatocellular carcinoma (HCC) spinal metastasis of ESCC grade 2. Methods : Patients with HCC spinal metastasis requiring surgery were retrospectively reviewed. Patients with ESCC grade 2, medically intractable mechanical back pain, a Nurick grade better than 3, 3-6 months of life expectancy, Tomita score ${\geq}5$, and Spinal Instability Neoplastic Score ${\geq}7$ were included. Patients with neurological deficits, other systemic illnesses and less than 1 month of life expectancy were excluded. Thirty patients were included in the study, including 17 in the open surgery group (until 2008) and 13 in the MIS group (since 2009). Results : The MIS group had a significantly shorter operative time ($94.2{\pm}48.2minutes$ vs. $162.9{\pm}52.3minutes$, p=0.001), less blood loss ($140.0{\pm}182.9mL$ vs. $1534.4{\pm}1484.2mL$, p=0.002), and less post-operative intensive care unit transfer (one patient vs. eight patients, p=0.042) than the open surgery group. The visual analogue scale for back pain at 3 months post-operation was significantly improved in the MIS group than in the open surgery group ($3.0{\pm}1.2$ vs. $4.3{\pm}1.2$, p=0.042). The MIS group had longer ambulation time ($183{\pm}33days$ vs. $166{\pm}36days$) and survival time ($216{\pm}38days$ vs. $204{\pm}43days$) than the open surgery group without significant difference (p=0.814 and 0.959, respectively). Conclusion : MIS without decompression would be a good choice for patients with HCC spinal metastasis of ESCC grade 2, especially those with limited prognosis, mechanical instability and no neurologic deficit.

비소세포폐암에서 21q 이형체 소실 (Loss of Heterozygosity on the Long Arm of Chromosome 21 in Non-Small Cell Lung Cancer)

  • 채포희;배락천;이응배;박재용;강경희;김경록;배문섭;차승악;채상철;김창호;정태훈
    • Tuberculosis and Respiratory Diseases
    • /
    • 제50권6호
    • /
    • pp.668-675
    • /
    • 2001
  • 연구배경 : 제21번 염색체가 3개(trisomy)인 다운 증후군(Down syndrome) 에서는 폐암을 포함한 고형종양의 빈도가 일반인에 비해 유의하게 낮다. 이와 같이 디운증후군에서 폐암 위험도가 낮은 것은 여분의 21번 염색체가 존재함에 따른 유전자-용량 효과(gene-dosage effect) 때문일 가능성이 있으며 이는 폐암의 발생과정에 관여하는 종양억제유전자가 21번 염색체에 있음을 의미한다. 저자들은 21번 염색체의 종양억제 유전자 발굴을 위한 선행연구로 21번 염색체 장암의 LOH 빈도와 LOH 유 무에 따른 임상상을 비교하였다. 방 법 : 근치적 절제술을 받은 비소세포폐암 39예를 대상으로 하였다. 동결된 폐암조직과 환자의 림프구에서 DNA를 추출한 후 21q의 5개의 현미부수체 표지자를 이용하여 PCR을 시행하고 6% polyacrylamide-8M urea gel에서 전기영동 한 후 silver 염색을 하였다. LOH는 암조직의 대립유전자 signal이 림프구의 50%이하로 감소된 경우로 판정하였으며 종양의 fractional allelic loss(FAL)는 informative 표지자 수에 대한 LOH가 발견된 표지자 수의 비로 계산하였다. 결 과 : 대상환자 39예 가운데 21예(53.8%)에서 한 개 이상의 표시자에서 LOH가 관찰되었다. LOH는 편평상피세포암의 경우 23예 가운데 15예(65.2%)에서, 선암의 경우는 16예 가운데 6예(37.5%)에서 관찰되어 편평상피세포암에서 LOH의 빈도가 높은 경향이 있었다. 편평상피세포암에서 LOH 빈도는 I 기 53.8%와 II-III기 80.0%로 진행된 병기에서 높은 경향이 있었으나 통계적 유의성은 없었다. 종양에서 대립 유전자 소실의 축적 정도를 반영하는 지표인 FAL치는 편평상피세포암의 경우 0.431(${\pm}0.375$)로 선암의 0.192(${\pm}0.276$)에 비해 통계적으로 유의하게 높았다. 편평상피세포암에서 FAL치는 I 기 0.391(${\pm}0.427$)인데 비해 II-III기는 0.484(${\pm}0.310$)로 통계적 유의성은 없었으나 진행된 병기에서 높은 경향을 보였다. 결 론 : 비소세포폐암에서 21q의 LOH가 흔히 관찰되었으며 이러한 결과는 비소세포폐암의 발암과정에 관여하는 종양억제유전자가 21q에 존재할 가능성을 강력히 시사한다. 21q에 존재하는 LOH의 역할을 규명하기 위해서는 향후 보다 많은 예를 대상으로 한 연구가 필요할 것으로 생각된다.

  • PDF

Gel Properties of Surimi-like Materials from Cardiac and Skeletal Muscle of Pigs

  • Kang, Geun-Ho;Yang, Han-Sul;Jeong, Jin-Yeon;Moon, Sang-Hoon;Joo, Seon-Tea;Park, Gu-Boo
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제20권8호
    • /
    • pp.1292-1296
    • /
    • 2007
  • To investigate the gel properties of surimi-like materials (SLM) made from pig heart (PH), psoas major muscle (PM) and semimembranosus muscle (SM) of pigs, the three muscles were diced, chopped and washed with 25 mM sodium phosphate buffer (pH 7.0) to extract myofibrillar protein. SLM from SM had significantly (p<0.05) higher moisture content and lower crude protein content compared with PH and PM samples. The cooked SLM from PH was darker than that from PM and SM. Gel from PH had significantly (p<0.05) lower L* and hue values, and higher b* and chroma values compared to gels from PM and SM. The cooked SLM from PH had poor water-holding capacity (WHC) resulting in higher cooking loss. SDS-PAGE showed that the bands of myosin and tropomyosin/troponin had reduced staining intensity in the PH sample, and some unidentified bands that were not in PM and SM samples were observed in PH samples.

Sensorless Sine-Wave Controller IC for PM Brushless Motor Employing Automatic Lead-Angle Compensation

  • Kim, Minki;Heo, Sewan;Oh, Jimin;Suk, Jung-Hee;Yang, Yil Suk;Park, Ki-Tae;Kim, Jinsung
    • ETRI Journal
    • /
    • 제37권6호
    • /
    • pp.1165-1175
    • /
    • 2015
  • This paper presents an advanced sensorless permanent magnet (PM) brushless motor controller integrated circuit (IC) employing an automatic lead-angle compensator. The proposed IC is composed of not only a sensorless sine-wave motor controller but also an isolated gate-driver and current self-sensing circuit. The fabricated IC operates in sensorless mode using a position estimator based on a sliding mode observer and an open-loop start-up. For high efficiency PM brushless motor driving, an automatic lead-angle control algorithm is employed, which improves the efficiency of a PM brushless motor system by tracking the minimum copper loss under various load and speed conditions. The fabricated IC is evaluated experimentally using a commercial 200 W PM brushless motor and power switches. The proposed IC is successfully operated without any additional sensors, and the proposed algorithm maintains the minimum current and maximum system efficiency under $0N{\cdot}m$ to $0.8N{\cdot}m$ load conditions. The proposed IC is a feasible sensorless speed controller for various applications with a wide range of load and speed conditions.

Assessment of lightweight recycled crumb rubber-cement composite produced by preplaced method

  • Shah, Syed Nasir;Mo, Kim Hung;Yap, Soon Poh;Putra, Azma;Othman, Muhammad Nur
    • Advances in concrete construction
    • /
    • 제11권5호
    • /
    • pp.409-417
    • /
    • 2021
  • The incorporation of non-biodegradable tyre waste in cement-based material has gained more interest towards sustainable construction these days. Crumb rubber (CR) from waste tyre is an alternative for sand replacement in low strength applications. Many researchers have studied CR cement-based materials produced by normal mixing (NM) method and reported a significant decrease in compressive strength due to CR. To compensate this strength loss, this research aims to study the innovative incorporation of CR in cement composite via the preplaced mixing (PM) method. In this investigation, cement composite was produced with NM and PM methods by replacing sand with 0%, 50%, and 100% CR by volume. The test results showed no significant difference in terms of densities of cement composite prepared with both mixing methods. However, cement composite prepared with PM method had lower strength reduction (about 10%) and lowered drying shrinkage (about 20%). In addition, the sound absorption coefficient and noise reduction coefficient of CR cement composite prepared by PM method were in similar range as those prepared with NM method. Overall, the results demonstrate that the PM method is promising, and the maximum replacement level of 50% is recommended for CR in the cement composite.

풍력터빈 PM형 동기발전기의 와전류손실과 열 해석에 관한 연구 (A Study on Rotor Eddy Current Loss and Thermal Analysis of PM Synchronous Generator for Wind Turbine)

  • 최만수;장영학;박태식;정문선;문채주
    • 전기학회논문지
    • /
    • 제63권11호
    • /
    • pp.1575-1581
    • /
    • 2014
  • In this paper, eddy current loss, iron loss and heat transfer of PMSG with 2,000kW capacities were analyzed for wind turbine. The PMSG with 3 split magnet was analyzed using ansoft maxwell commercial program and, generator was tested by Back to Back converter with no load condition at laboratory. Rotor surface temperature was measured by Pt100 sensors for investigating heat transfer from rotor to atmosphere. The simulation results shows 27.4kW eddy current loss in no load condition and 50.2kW eddy current loss in rated load condition with 3 split magnet, and also shows 4.3kW iron loss in no load condition and 7.3kW iron loss rated load condition. The heat transfer coefficient of convection between rotor surface and atmosphere was investigated by $9.6W/m^2{\cdot}K$. Therefore the heat transfer from rotor to atmosphere was about 17kW(54%) and from rotor to air-gap was about 14.6kW(46%) in no load condition. It is identified that the cooling system for stator have to include the 46% of iron loss, and heat dissipation structure of rotor surface have to be suggested and designed for efficiency improvement of generator.

집중권을 시행한 영구자석 매입형 동기전동기의 철손 저감 (Core-loss reduction on PM for IPMSM with concentrated winding)

  • 이형우;박찬배;이병송;김남포
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.1832-1837
    • /
    • 2011
  • This paper presents the optimal permanent magnet shape on the rotor of an interior permanent magnet motor to reduce the core losses and improve the performance. As permanent magnet has conductivity inherently, it causes huge amount of eddy current losses by the slot harmonics with concentrated winding. This loss is roughly 100 times larger than that of distributed winding in high speed operation and it cannot be ignored, especially on traction motors. Each eddy current loss on permanent magnet has been investigated in detail by using FEM(Finite Element Method) instead of EMCNM(Equivalent Magnetic Circuit Network Method) in order to consider saturation and non-linear magnetic property. Simulation-based DOE(Design Of Experiment) is also applied to avoid large number of analyses according to each design parameter and consider expected interactions among parameters. Consequently, the optimal design to reduce the core loss on the permanent magnet while maintaining or improving motor performance is proposed by an optimization algorithm using regression equation derived and lastly, the core loss reduction on the proposed shape of the permanent magnet is verified by FEM.

  • PDF

낮은 변환손실과 높은 LO-RF 격리도 특성을 갖는 94 GHz Resistive Mixer 의 제작 (Fabrications of Low Conversion Loss and High LO-RF Isolation 94 GHz Resistive Mixer)

  • 이복형;이진구
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2005년도 추계종합학술대회
    • /
    • pp.921-924
    • /
    • 2005
  • We report low conversion loss and high LO to RF isolation 94 GHz MMIC resistive mixers based on 0.1 ${\mu}m$ InGaAs/InAlAs/GaAs metamorphic HEMT technology. The fabricated resistive mixers applied a one-stage amplifier on RF port of the mixer. By using the one-stage amplifier, we obtained the decrement of conversion loss and the increment of LO to RF isolation. So, we can obtain higher performances than conventional resistive mixers. The modified mixer shows excellent conversion loss of 6.7 dB at a LO power of 10 dBm. We also observed an extremely high isolation characteristic from the MMICs exhibiting the LO-RF isolation of 21 ${\pm}$ 0.5dB in a frequency range of 93.7${\sim}$ 94.3 GHz. The low conversion loss and high LO-RF isolation characteristics of the MMIC modified resistive mixers are mainly attributed to the performance of the MHEMTs exhibiting a maximum transconductance of 654 mS/mm, a current gain cut-off frequency of 173 GHz and a maximum oscillation frequency of 271 GHz.

  • PDF

Bone cement grafting increases implant primary stability in circumferential cortical bone defects

  • Shin, Seung-Yun;Shin, Seung-Il;Kye, Seung-Beom;Chang, Seok-Woo;Hong, Jongrak;Paeng, Jun-Young;Yang, Seung-Min
    • Journal of Periodontal and Implant Science
    • /
    • 제45권1호
    • /
    • pp.30-35
    • /
    • 2015
  • Purpose: Implant beds with an insufficient amount of cortical bone or a loss of cortical bone can result in the initial instability of a dental implant. Thus, the objective of this study was to evaluate the effect of bone cement grafting on implant initial stability in areas with insufficient cortical bone. Methods: Two different circumferential defect depths (2.5 mm and 5 mm) and a control (no defect) were prepared in six bovine rib bones. Fourteen implants of the same type and size ($4mm{\pm}10mm$) were placed in each group. The thickness of the cortical bone was measured for each defect. After the implant stability quotient (ISQ) values were measured three times in four different directions, bone cement was grafted to increase the primary stability of the otherwise unstable implant. After grafting, the ISQ values were measured again. Results: As defect depth increased, the ISQ value decreased. In the controls, the ISQ value was $85.45{\pm}3.36$ ($mean{\pm}standard$ deviation). In circumferential 2.5-mm and 5-mm defect groups, the ISQ values were $69.42{\pm}7.06$ and $57.43{\pm}6.87$, respectively, before grafting. These three values were significantly different (P<0.001). After grafting the bone cement, the ISQ values significantly increased to $73.72{\pm}8.00$ and $67.88{\pm}10.09$ in the 2.5-mm and 5.0-mm defect groups, respectively (P<0.05 and P<0.001). The ISQ value increased to more than double that before grafting in the circumferential 5-mm defect group. The ISQ values did not significantly differ when measured in any of the four directions. Conclusions: The use of bone cement remarkably increased the stability of the implant that otherwise had an insufficient level of stability at placement, which was caused by insufficient cortical bone volume.