Effect of Collection Time in Oocyte Recovery from Superovulated Korea Native Goats (재래산양의 과배란처리에 있어서 회수시간이 난자의 회수율에 미치는 영향)

  • Park, H.-S.;Jung, S.-Y.;Kim, T.-S.;Lee, M.-Y.;Jin, J.-I.;Hong, S.-P.;Lee, J.-S.;Kim, C.-H.
    • Journal of Embryo Transfer
    • /
    • v.19 no.2
    • /
    • pp.113-119
    • /
    • 2004
  • The purpose of the present study was to examine whether collection time affects results of oocyte recovery from superovulated goats. Fiftyty-one mature Korean native goats, maintained in a pen under natural day length and fed hay ad libitum, were pretreated with progestagen impregnated CIDR for 10 days and then the goats were divided into two groups. One group of the goats received a single intramuscular injection of 1,000 IU PMSG on Day 8 of CIDR insertion. The other group of the goats received twice daily intramuscular injections of a total of 70 mg FSH for 3 days from Day 8 of CIDR. All the gonadotropin treated goats were injected with 10 mg $PGF_{2\alpha}$ on Day 8 and 400 IU hCG in the afternoon on Day 10. For oocyte recovery, donor goats were fasted 24 h before operation. Anesthesia was induced by intravenous injection of 2% xylazine(0.2 mg/kg body weight) and ketamin(11 mg/kg body weight). In vivo oocytes were recovered by follicle aspiration or oviduct flushing at 29 to 34, 35 to 40 and 41 to 50 h after hCG injection through mid-ventral incision. There was no significant difference in the mean number of CL and oocytes recovered. Oocyte collection at 29 to 40 h after hCG increased(P<0.05) the recovery rate of ovulated oocytes in oviducts compared to 41 to 50 h. The same results were also observed in the recovery of follicular oocytes. Oocyte grade was not affected by collection time. When oocytes were collected from follicular oocytes at 41 to 50 h after hCG, the recovery rate of Grade II oocytes was the lowest(P<0.05). From these results, it is suggested that oocyte recovery at 35 to 40 h after hCG will be successful for further use.

Study on the Characteristics of Concentrations and Compositions in $PM_{10}$ in Kunsan City (군산 지역에서 $PM_{10}$의 농도 및 성분 특성에 관한 연구)

  • 김성천;송재종;임성호;강달선
    • Journal of Environmental Health Sciences
    • /
    • v.26 no.3
    • /
    • pp.18-24
    • /
    • 2000
  • The collection of PM10 samples were collected by a PM10 hi-vol. air sampler from June, 1998 through May, 1999 in Kunsan located at western coastal region of Korea. We obtained 84 samples during sampling period. Samples were analyzed to quantify the concentration of ionic and metallic components such as SO42-, NO3-, Cl-, NH4+, K+, Na+, Mg2+, Zn, Cd, Cr, Pb and Fe. Seasonal variations of the concentrations by wind directions of each component were studied. We found that PM10 concentration had the highest level in winter and the lowest level in summer. When the wind direction is from west to east, the concentration of most ionic and metallic species were higher compared to reverse direction. That implied the effect of air pollutants from industrial area. Also, substantial amount of Na+ and Cl- were observed, which was assumed to the effect from the sea.

  • PDF

Effect of Working on Physiological, Biochemical and Haematological Parameters in Hariana Bullocks

  • Yadav, A.S.;Dhaka, S.S.;Kumar, B.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.14 no.8
    • /
    • pp.1067-1072
    • /
    • 2001
  • An experiment was conducted on eight bullocks of Hariana cattle study draft efficiency using different appliances, changes in their physiological, biochemical and haematological parameters, and how the body tries to maintain these within normal physiological range. Blood collection was done at pre-exercise, three hours after exercise and two hours post exercise in summer and winter seasons of the year 1990-91. Average pulse rate and respiration rate per minute were found to be $63.09{\pm}0.78,\;25.60{\pm}0.54,\;97.21{\pm}2.51,\;63.37{\pm}2.70,\;64.05{\pm}1.90,\;25.33{\pm}1.20$, respectively, at pre-exercise, three hours exercise and two hours post exercise rest. The seasonal differences were found to significant and the values were higher in summer than in winter. After two hours post exercise rest Hariana bullocks regained their normal values for all the parameters, except that pulse rate, respiration rate and serum sodium during summer did not reach the pre - exercise levels.

Field Application of a Double Filtration Process to Control Fine Dust in a Metro Subway Station (도시 지하역사 미세먼지제어를 위한 이중여과장치의 현장적용 연구)

  • Park, Haewoo;Kim, Wooram;Jo, Youngmin
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.29 no.5
    • /
    • pp.625-633
    • /
    • 2013
  • This study attempted to find an alternative method for fine dust control in the pre-exiting facilities of metro-subway stations. A new double-layer design was proposed for the MVAC (mechanical ventilation and air control) system. Several filter lay-outs were combined a pre-filter with electret filter (EF), electret bundle filter (EBF), or electret pleated filter (EPF), and were then examined focusing on the collection efficiency of particulate matters and pressure drop across the filter layers. The experimental results from the lab and field tests showed the best collection efficiency with EPF, which achieved 85% for $PM_{10}$ and 55% for $PM_{2.5}$. It was also found from the long term field test that the new filter lay-out could provide quite consistent dust level particularly in underground platform regardless of external condition.

OBSERVATIONS ON FERTILITY PARAMETERS FOLLOWING SUPEROVULATION IN JERSEY CATTLE

  • Ullah, N.;Javed, M.H.;Akhtar, S.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.8 no.4
    • /
    • pp.321-323
    • /
    • 1995
  • Observations were recorded regarding various fertility parameters on 26 Jersey donor cows following superovulation under tropical conditions. These cows, in their mid-luteal phase were treated with 2,500-3,000 i.u. PMSG or 28-40 mg FSH followed by $500{\mu}g$ $PGF_{2{\alpha}}$ injection 48-60 hours later, to induce oestrus. The cows were bred artificially twelve hours following standing oestrus. Embryo collection was carried out 7 days after oestrus. $PGF_{2{\alpha}}$ was injected to each donor cow after embryo recovery to regress the corpora lutea. Fertility data($PGF_{2{\alpha}}$-Oestrus interval, services per conception, days between embryo collection and successful service and any pathololgical condition) were recorded. $PGF_{2{\alpha}}$-Oestrus interval and correlation (r) between number of corpora lutea and $PGF_{2{\alpha}}$-Oestrus interval were $30.9{\pm}6.3$ and 0.17, respectively. Of 26 treated donors, 19 conceived within a period of $91.7{\pm}18.8$ days after embryo recovery. Average services per conception were $2.3{\pm}0.3$. Only two cows developed metritis which conceived after treatment with antibiotics. These observations indicated no profound adverse effect of superovulation on subsequent reproduction of donor cows, except some effect on services per conception, under tropical conditions.

Relationships between TSP and PM10 Concentrations in the Ambient Atmosphere (대기 중 TSP와 PM10 농도의 관련성)

  • 최진수;백성옥
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.14 no.1
    • /
    • pp.1-10
    • /
    • 1998
  • Relationships between TSP and PM10 concentrations were evaluated using their respective data sets collected from Taegu and Kyeungsan areas during the period of December 1993 to November 1994. The collection of data was made using the gravimetric and $\beta$-ray absorption ($\beta$-MPM) methods for 7 days of every month from three urban sites in Taegu and one suburban site in Kyeungsan. Correlation coefficients between TSP and PM10 concentrations for these four sampling sites were found in the range of 0.85 $\sim$ 0.96. Correlation analysis was also conducted for $\beta$-PM concentration data that were measured only from the residential and commercial sites. The correlation coefficients between TSP and $\beta$-PM concentrations were 0.9 in the residential site and 0.8 in the commercial site. By contrast, the correlation coefficients between PM10 $\beta$-PM concentrations were almost identical for both the residential and commercial sites with a value of 0.88. The mean ratio for PM10 to TSP concentrations for all sites was appeared to be 0.68. The analysis of seasonal trends in PM10/TSP ratios showed that the contribution of PM10 to TSP concentrations was more significant during winter (0.70 $\sim$ 0.75) than during summer (0.61 $\sim$ 0.68). The results of this study may provide empirical informations on the compatability of aerosol data measured by different sampling methods.

  • PDF

The Study of Factor Concerning Ovum Pick-up and Conception Rate by Ultrasound-Guided Follicular Aspiration in Hanwoo Heifers (한우에 있어서 초음파기기를 이용한 생체내 난자 채취시 채란조건 및 수태율에 관한 연구)

  • 박성재;양보석;임기순;성환후;장원경;정일정;박충생
    • Korean Journal of Animal Reproduction
    • /
    • v.24 no.2
    • /
    • pp.199-208
    • /
    • 2000
  • This study was carried out to investigate of factors concerning to ultrasound-guided follicular aspiration; level of vacuum pressure, diameter of use needle, effect of FSH hormone and conception rate after embryos transfer. 1. Oocytes collection number were 4.2$\pm$2.9 e.a to luteuml phase and follicular phase were 4.4$\pm$3.5 e.a to ovaries of Hanwoo. 2. We taked proper level of aspiration vacuum pressure was 40~120 mmHg to oocytes collection. Oocytes collected number were 4.2$\pm$3.2, 4.3$\pm$3.4, 4.5$\pm$3.4 e.a. to 40, 80, 120mmHg, respectively, follicles aspiration rate were 49, 47, 45%. 3. Effect of collection needle diameter was not difference significantly(P<0.05), oocytes collected number were 4.4$\pm$3.5 e.a to 170 and 3.0$\pm$1.8 e.a to 18G needle, collected oocytes quality were no difference significantly (P<0.05). 4. Follicles increase number to FSH hormone injection were 6.2$\pm$2.3 e.a to intramuscle and 1.1$\pm$2.7 e.a. to epithelial injection method. 5. Conception rate derived from E.T. was 11.1% to freezing embryos and 46.2% to fresh E.T., difference significantly(P<0.05).

  • PDF

Comparison of Sampling Methods for Determining Airborne Mixture of Organic Solvents (공기중 유기용제 혼합물 측정방법의 비교연구)

  • Chun, Mee Hye;Paik, Nam Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.1 no.1
    • /
    • pp.16-28
    • /
    • 1991
  • A study on comparison of standard charcoal tube method, infrared gas analyzer, and detector tube method were conducted. Measurements were performed simultaneously at same sampling points in an air chamber containing benzene, toluene and xylene vapors. Charcoal tube samles were collected at sampling flowrates of 0.05, 0.2, 0.5, and 1.0 1pm. Results are as follows : 1. Coefficients of variation of results with charcoal tube method for bezene, toluene and xylene mixture vapor were 14.34 % in benzene(0.28-11.12 ppm), 9.20 % in toluene (2.68-135.09 ppm) and 10.21 % in xylene (2.56-82.64 ppm), respectively. 2. Results of infrared gas analyzer in mixture air were non-specific on benzene and toluene. Ratio of results of infrared gas analyzer to those of charcoal tube on benzene, toluene and xylene were 696.4 %, 30.3 % and 36.6 %, respectively. 3. Ratio of responses of detector tubes to those of charcoal tube were 49.4 % in benzene, 22.1 % in toluene and 223.9 % in xylene. Xylene detector tube were interfered by toluene greately. 4. Collection efficiencies of charcoal tubes at low concentraton(benzene : 1 ppm, toluene : 10 ppm, xylene : 10 ppm) were stable on various flowrate from 0.05 to 1.0 1pm, but at high concentrations the efficiency decreased at high flowrate above 0.5 1pm. 5. Within the saturation capacity of charcoal, collection effiency decreased at 0.5-1.0 1pm. Smpling feowrates of 0.05-0.20 1pm were appropriate for sampling organic vapors.

  • PDF

Emission Characteristics of PMs and Heavy Metals from Industrial Hazardous Waste Incinerators (산업 폐기물 소각시설의 입자상 물질 및 중금속의 배출특성)

  • 유종익;이성준;김기헌;장하나;석정희;석광설;홍지형;김병화;서용칠
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.3
    • /
    • pp.213-221
    • /
    • 2002
  • The emission characteristics of particulate matter (PMs) and heavy metals from hazardous industrial wast incinerators were investigated. The particle size distribution (PSD) of PM-10 showed different patterns for two tripes of incinerators; stoker and rotary kiln. However both types showed bimodal form at inlet of air pollution control devices (APCD) and each peak (mode) is located at smaller than 1 ${\mu}{\textrm}{m}$ and near 10 ${\mu}{\textrm}{m}$. It could explain the growth of fine PM by nucleation/coagulation/condensation of metal vapors for fine mode. The PSD of PM-10 after APCD was also influenced by APCD types that had different collection mechanism, and both electrostatic precipitator and bag filter showed less collection efficiency for particles ranged from 0.2 to 0.4 ${\mu}{\textrm}{m}$ and led to a mode in the range of 0.2 to 0.8 ${\mu}{\textrm}{m}$. However the hag filter showed two modes of PSD, while the electrostatic precipitator had one peak. The PMs and heavy metals emission factors, the representative value of emission quantity for sources, for tested facilities were developed. The emission factor of uncontrolled total PM and PM-10 were 14.7 and 7.05 kg/ton waste, respectively. The emission factors from this study were a little bit different with those from US EPA AP-42. It may thus be appropriate to use these results in the course of developing national emission factors.

Investigation of Characteristics of Electrostatic Bag Filter with Discharge Electrode Shapes and Filter Properties (방전극 형상 및 여과재에 따른 정전 여과집진장치특성에 관한 연구)

  • 김정일;여석준
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.14 no.3
    • /
    • pp.237-250
    • /
    • 1998
  • In this study, the characteristics of electrostatic bag filter to overcome the main problems such as the high pressure drop and low collection efficiency for submicron particles are investigated with the experimental parameters. Especially, the experiment is carried out focusing on collection efficiency and pressure drop change mechanism as a function of discharge electrode shapes and filter properties, including the applied voltages, filtration velocities and particle concentrations, etc . Results show that the collection efficiency is improved over 30% for the fine particle below 1 pm and pressure drop reduction ratio (PDRR) increases in the following order 4 mm screwy > 4 mm square > 4mm round discharge electrodes . For the filter properties, Nomex is more effective than PE under the influence of electrostatic force. Applying 30 kV for a screwy discharge electrode, higher overall collection efficiency is maintained in spite of the increment of filtration velocity over four times (8 m/min) in comparison with that of 2 m/min and PDRR are highly shown over 80o1o with various filtration velocities, 5, 8, 11 m/min.

  • PDF