• Title/Summary/Keyword: PLS Regression

Search Result 175, Processing Time 0.03 seconds

Accounting Earnings Response Coefficient: Is the Earning Response Coefficient Better or Not

  • PARAMITA, Ratna Wijayanti Daniar;FADAH, Isti;TOBING, Diana Sulianti K.;SUROSO, Imam
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.7 no.10
    • /
    • pp.51-61
    • /
    • 2020
  • The study aims to compare whether using Earnings Response Coefficient (ERC) is better than using the new concept of Accounting Earnings Response Coefficient (AERC) in determining the earnings quality response coefficient value. Also, the study seeks to explain the effect of company characteristics and corporate governance on AERC through voluntary disclosure and information asymmetry. Research samples include 69 manufacturing companies listed on the Indonesian Stock Exchange over the period 2014-2017. The data come from annual reports, stock market prices, CSPI, EPS, stock returns and market returns. The research model is tested using the structural equation model (SEM) with partial least square (PLS). The results showed the value of the earnings response coefficient produced by AERC and ERC was different. Earnings quality resulting from AERC regression by adding CFO values better reflects the actual earnings quality. These results are consistent with the concept built from the proposition about earnings quality at AERC, that quality earnings are informative accounting earnings. The theoretical findings of this study provide an explanation that operational cash flow plays a role in evaluating earnings quality, while providing reinforcement that the ERC regression model fails to detect stock market reactions to information relevant to the aggregated values of accounting earnings.

Design and performance evaluation of portable electronic nose systems for freshness evaluation of meats II - Performance analysis of electronic nose systems by prediction of total bacteria count of pork meats (육류 신선도 판별을 위한 휴대용 전자코 시스템 설계 및 성능 평가 II - 돈육의 미생물 총균수 예측을 통한 전자코 시스템 성능 검증)

  • Kim, Jae-Gone;Cho, Byoung-Kwan
    • Korean Journal of Agricultural Science
    • /
    • v.38 no.4
    • /
    • pp.761-767
    • /
    • 2011
  • The objective of this study was to predict total bacteria count of pork meats by using the portable electronic nose systems developed throughout two stages of the prototypes. Total bacteria counts were measured for pork meats stored at $4^{\circ}C$ for 21days and compared with the signals of the electronic nose systems. PLS(Partial least square), PCR (Principal component regression), MLR (Multiple linear regression) models were developed for the prediction of total bacteria count of pork meats. The coefficient of determination ($R_p{^2}$) and root mean square error of prediction (RMSEP) for the models were 0.789 and 0.784 log CFU/g with the 1st system for the pork loin, 0.796 and 0.597 log CFU/g with the 2nd system for the pork belly, and 0.661 and 0.576 log CFU/g with the 2nd system for the pork loin respectively. The results show that the developed electronic system has potential to predict total bacteria count of pork meats.

Quantification of Skin Moisture in Hairless Mouse by using a Portable NIR System and a FT NIR Spectrometer (Photo Diode Array형의 휴대용 근적외 분광기와 FT 근적외 분광기를 이용한 Hairless Mouse 피부 수분 정량)

  • Suh, Eun-Jung;Woo, Young-Ah;Kim, Hyo-Jin
    • YAKHAK HOEJI
    • /
    • v.49 no.2
    • /
    • pp.115-121
    • /
    • 2005
  • In this study, the performance of a portable NIR system and a FT NIR spectrometer were compared to determine water content of hairless mouse skin. The stratum corneum parts wer e separated from the epidermal tissues by trypsin solution. NIR diffuse reflectance spectra of hairless mouse skin were acquired using a fiber optic probe. In the near infrared, water molecules show two clear absorption bands at 1450 nm from first overtone of O-H stretching and 1940 nm from the combination involving O-H stretching and O-H deformation. It was found that the variations of O-H absorption band according to water content. Partial least squares regression (PLSR) was applied to develop a calibration model. The PLS model showed a good correlation between NIR predicted value and the absolute water content of separated hairless mouse skin, in vitro. For both the portable and the FT NIR spectrometer, These studies showed the possibility of a rapid and nondestructive skin moisture measurement using NIR spectroscopy. The portable NIR spectrometer with a photodiode arrays-microsensor could be more rapidly applied for the determination of water content with comparable accuracy with the performance of a FT spectrometer .

The Impacts of Industrial Characteristics of Cities on Fine Dust Levels (도시의 산업특성이 미세먼지 농도에 미치는 영향)

  • Eum, Jeongin;Kim, Hyungkyoo
    • Journal of Environmental Science International
    • /
    • v.29 no.5
    • /
    • pp.445-455
    • /
    • 2020
  • Fine dust is one of the most critical environmental issues in Korea, and the government recognizes the need to establish customized reduction policies based on regional characteristics. Several studies on air pollutants investigate whether factories affect the distribution of fine dust in a particular region. However, understanding the impact of the entire industry sector requires further investigation. This study identifies the impacts of industrial characteristics on fine dust levels of 141 municipalities across Korea in 2016. A total of 23 variables were used, of which 12 referred to industries and 11 to general characteristics of each city. Due to the high correlation between independent variables, partial least squares (PLS) regression models were used. The analysis identified 14 significant variables for PM10 and 13 for PM2.5. Therefore, the results suggest that local industrial characteristics can significantly influence fine dust levels and provide suggestions for establishing customized reduction policies based on local characteristics.

Quantitative structure activity relationship (QSAR) between chlorinated alkene ELUMO and their chlorine

  • Tang, Walter Z.;Wang, Fang
    • Advances in environmental research
    • /
    • v.1 no.4
    • /
    • pp.257-276
    • /
    • 2012
  • QSAR models for chlorinated alkenes were developed between $E_{HOMO}$ and their chlorine and carbon content. The aim is to provide valid QSAR model which is statistically validated for $E_{LUMO}$ prediction. Different molecular descriptors, $N_{Cl}$, $N_C$ and $E_{HOMO}$ have been used to take into account relevant information provided by molecular features and physicochemical properties. The best model were selected using Partial Least Square (PLS) and Multiple Linear Regression (MLR) led to models with satisfactory predictive ability for a data set of 15 chlorinated alkene compounds.

Analysis of Main Design Factors for Developing a Soil Water Content Sensor Using Impedance Spectroscopy (Impedance Spectroscopy를 이용한 토양 수분함량 센서의 주요 설계인자 분석)

  • Lee, Dong-Hoon;Cho, Yong-Jin;Chang, Young-Chang;Lee, Kyou-Seung
    • Journal of Biosystems Engineering
    • /
    • v.33 no.4
    • /
    • pp.269-275
    • /
    • 2008
  • This study was conducted to design an impedance sensor that can measure soil water content of soils. Partial least square regression (PLSR) was applied to soil impedance data preprocessed with a smoothing method. An optimal sub-spectrum size and wavelength range were determined by comparing the coefficient of determination ($R^2$) and root mean square error (RMSE) of the PLSR models obtained using soil impedance data. various PLS analysis. Based on the PLSR analysis, it would be concluded that the optimal spectrum measurement range was $32.0{\sim}50.0\;MHz$ with the optimal sub-spectrum size of about 18.5 MHz.

Application of SeaWiFS data for assessment of eutrophication in the Pearl River estuary

  • Chen, Chuqun;Li, Xiaobin
    • Proceedings of the KSRS Conference
    • /
    • v.2
    • /
    • pp.909-912
    • /
    • 2006
  • In this paper a method for remotely-sensed assessment of eutrophication was experimented. The water samples were collected for analysis of COD (chemical oxygen demand) and nutrients concentration, and the remote sensing reflectance data at the sampling points were synchronously measured using above-water method in two cruises, which were conducted in the Pearl River Estuary in January 2003 and January 2004 respectively. Based on the in-situ data the local algorithms for estimation of concentration of nutrients (P and N) and COD were developed by Partial Least Squares (PLS) regression. The algorithms were then applied to atmospheric-corrected SeaWiFS data and the COD and nutrients concentration in Pearl River Estuary were estimated. And then the assessment of eutrophication was carried out by comparison of the estimated nutrients and COD value with the water quality standard. The results show that the whole estuary is seriously in eutrophication.

  • PDF

Discrimination of Oil Seeds According to Geographical Origin Using Near Infrared Reflectance Spectroscopy (근적외선 분광분석법을 이용한 유량종자의 원산지 판별)

  • Kwon, Hye-Soon
    • Journal of the Korean Applied Science and Technology
    • /
    • v.16 no.1
    • /
    • pp.21-24
    • /
    • 1999
  • Sesame seed (Sesamum indicum L.) is an important seasoning in Korea and most korean consumer tend to eat the korean sesame seed as the best than other ones produced in oriental countries such as China and Japan. Near infrared reflectance spectroscopy (NIRS) was applied for discrimination according to geographical origin (Korea, China and so on) of sesame seeds. Near-infrared spectroscopy among the many kinds of techniques could provide a rapid screening, low cost solution to discriminate geographical origin of sesame seed. The objective of this study is to determine if NIR technique could be used to discriminate between the korean sesame seed and non-korean sesame seed by using the new method. Rapid, precise and nondestructive analysis method for determination of the geographic origin of sesame seeds were discriminated relative accurately according to geographical origin using PLS regression method.

Near-infrared Spectroscopic Measurement of Glucose Under the Existence of Other Major Blood Components (혈액의 주요 구성물질 존재 하에서 근적외분광분석법을 이용한 글루코오스 측정)

  • 백주현;강나루;우영아;김효진
    • YAKHAK HOEJI
    • /
    • v.48 no.3
    • /
    • pp.171-176
    • /
    • 2004
  • This study was described for measuring clinically relevant levels of glucose in undiluted plasma and whole blood by near-infrared (NIR) spectroscopy. Result from an initial measurement of major blood components powder was over-lapped the absorption bands of glucose at 1500-1600 nm. However, the NIR data of blood components were clearly separated by principle component analysis (PCA) space. By the use of partial least squares (PLS) regression, glucose concentrations in undiluted plasma and whole blood could be determined with standard errors of prediction (SEP) of 15 mg/dl and 76 mg/dl, respectively. Although these blood components possessed strong absorption bands that overlapped with the absorption bands of glucose, successful calibration models could be carried out.

Compensation of Variation from Long-Term Spectral Measurement for Non-invasive Blood Glucose in Mouse by Near-Infrared Spectroscopy (근적외분광분석법을 이용한 생쥐꼬리에서의 비침습 혈당 정량시 장기간 측정에 따른 변이 요인의 보정)

  • 백주현;강나루;우영아;김효진
    • YAKHAK HOEJI
    • /
    • v.48 no.3
    • /
    • pp.177-181
    • /
    • 2004
  • Non-invasive blood glucose measurement from mouse tail was performed by near-infrared (NIR) spectroscopy. Three groups; normal, type I diabetes (insulin dependent diabetes mellitus, IDDM), type II diabetes (non-insulin dependent diabetes mellitus, NIDDM) group, were studied over a 10 weeks period with the collection of near-infrared (NIR) spectra. Spectral variations from long-term measurement (10 weeks) from dramatic and nonlinear changes in the optical properties of the live tissue sample were compensated by chemometrics techniques such as principle component analysis (PCA) and partial least squares (PLS) regression. The effect from mouse body temperature changes on NIR spectral data was also considered. This study showed that the compensation of variations from long-term measurement and temperature changes improved calibration accuracy of non-invasive blood glucose measurement.