• 제목/요약/키워드: PLD

검색결과 619건 처리시간 0.029초

Ni-W 기판 위에 동시증발법으로 제조한 SmBCO 초전도선재 (SmBCO superconducting tape fabricated using co-evaporation method on Ni-W substrate)

  • 오상수;김호섭;하홍수;고락길;송규정;하동우;이남진;양주생;김태형;정예현;염도준
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제8권3호
    • /
    • pp.9-12
    • /
    • 2006
  • Batch type co-evaporation EDDC (Evaporation using Drum in Dual Chambers) system was recently manufactured to fabricate 100m - long SmBCO superconducting coated conductor. As a preliminary study before the fabrication of long tape. short CC samples have been fabricated using the EDDC system and their crystal texture and $I_c$ properties were investigated. $1.2 {\mu}m$-thick SmBCO layers were deposited on $CeO_2/YSZ/CeO_2$ buffered Ni-W tapes. $I_c$ of 128A/cm-w and corresponding $J_c$ of $1.1 MA/cm^2$ at 77K in self-field were obtained for SmBCO CC tape. In-field property of SmBCO CC was confirmed to be better than that of YBCO deposited by PLD.

차별적이니 드랍-확률을 갖는 동적-VQSDDP를 이용한 상대적 손실차별화의 달성 (Achieving Relative Loss Differentiation using D-VQSDDP with Differential Drop Probability)

  • 조경래;구자환;정진욱
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2008년도 추계학술발표대회
    • /
    • pp.1332-1335
    • /
    • 2008
  • In order to various service types of real time and non-real time traffic with varying requirements are transmitted over the IEEE 802.16 standard is expected to provide quality of service(QoS) researchers have explored to provide a queue management scheme with differentiated loss guarantees for the future Internet. The sides of a packet drop rate, an each class to differential drop probability on achieving a low delay and high traffic intensity. Improved a queue management scheme to be enhanced to offer a drop probability is desired necessarily. This paper considers multiple random early detection with differential drop probability which is a slightly modified version of the Multiple-RED(Random Early Detection) model, to get the performance of the best suited, we analyzes its main control parameters (maxth, minth, maxp) for achieving the proportional loss differentiation (PLD) model, and gives their setting guidance from the analytic approach. we propose Dynamic-multiple queue management scheme based on differential drop probability, called Dynamic-VQSDDP(Variable Queue State Differential Drop Probability)T, is proposed to overcome M-RED's shortcoming as well as supports static maxp parameter setting values for relative and each class proportional loss differentiation. M-RED is static according to the situation of the network traffic, Network environment is very dynamic situation. Therefore maxp parameter values needs to modify too to the constantly and dynamic. The verification of the guidance is shown with figuring out loss probability using a proposed algorithm under dynamic offered load and is also selection problem of optimal values of parameters for high traffic intensity and show that Dynamic-VQSDDP has the better performance in terms of packet drop rate. We also demonstrated using an ns-2 network simulation.

위성통신용 전력제어 고출력증폭기의 구현 및 성능평가에 관한 연구 (A Study on Implementation and Performance of the Power Control High Power Amplifier for Satellite Mobile Communication System)

  • 전중성;김동일;배정철
    • 한국정보통신학회논문지
    • /
    • 제4권1호
    • /
    • pp.77-88
    • /
    • 2000
  • 본 논문에서는 INMARSAT-B형 송신기에 사용되는 L-BAND(1626.5-1646.5 MHz)용 3단 가변이득 전력증폭기를 연구 개발하였다. 3단 가변이득 전력증폭기는 구동증폭단과 전력증폭단에 의해 고출력 모드일 때 +42 dBm, 중간출력 모드일 때는 +38 dBm, 저출력 모드일 때는 +34 dBm의 전력으로 증폭되며, 각각에 대해 상한 +1 dBm과 하한 2 dBm의 오차를 허용한다. 제작의 간편성 때문에 전체 3단 가변이득 전력증폭기를 크게 구동증폭단과 전력증폭단 두 부분으로 나누어 구현하였으며, 전력증폭부를 구동하기 위한 구동단은 HP사의 MGA-64135와 Motorola사의 MRF-6401을 사용하였으며, 전력증폭단은 ERICSSON사의 PTE-10114와 PTF-10021을 사용하여 RP부, 온도보상회로, 출력 조절회로 및 출력 검출회로를 함께 집적화 하였다. 이득조절은 디지털 감쇠기를 사용하였으며, 출력신호의 세기를 검출하기 위하여 20 dB 방향성 결합기를 이용하였다. 제작된 3단 가변이득 전력증폭기는 20 MHz대역폭 내에서 소신호 이득이 41.6 dB, 37.6 dB, 33.2 dB 를 얻었으며, 입출력 정재파비는 1.3:1 이하, 12 dBm의 PldB, PldB 출력레벨에서 3 dB Back off 시켰을 때 36.5 dBc의 IM3를 얻었다. 1636.5 MHz 주파수에 대해 출력전력은 43 dBm으로서 설계시 목표로 했던 최대 출력전력 20 Watt를 얻었다.

  • PDF

유독 와편모조류 Pfiesteria Piscicida 탐지 및 정량 분석을 위한 EvaGreen 기반 Real-time PCR기법 개발과 현장 적용 (Development of EvaGreen Based Real-time PCR Assay for Detection and Quantification Toxic Dinoflagellate Pfiesteria Piscicida and Field Applications)

  • 박범수;주재형;김묘경;김주환;김진호;백승호;한명수
    • 한국해양학회지:바다
    • /
    • 제22권1호
    • /
    • pp.31-44
    • /
    • 2017
  • Pfiesteria piscicida는 유독 종속영양 와편모조류로서, 크기가 작고 형태학적으로 유사한 Pfiesteria-like dinoflagellate (PLD) 종들로 인해, 광학 현미경 관찰만으로 정확하게 동정하는 것이 불가능하다. 따라서, 본 연구에서는 이러한 한계점을 극복하기 위해 EvaGreen 기반의 정량적 real-time PCR기법을 개발하였으며, 한국 근해에서 P. piscicida의 분포와 시화호에서 개체군 변동 조사를 통해 현장에서 유용성을 검증하였다. 이를 위해, internal transcribed spacer 1 (ITS 1) 영역을 대상으로 종 특이적 프라이머를 제작하였으며, P. piscicida와 진화적 유연관계에 있는 다양한 미세조류에 대해 PCR을 수행하여 프라이머의 특이성을 검증하였다. 개발된 프라이머를 real-time PCR 기법에 적용한 결과, P. piscicida의 세포수와 $C_T$값 간의 유의한 표준 곡선($r^2{\geq}0.999$)과 하나의 융해곡선 피크($88^{\circ}C$)가 관찰되었다. 이는 본 연구에서 개발된 기법이 대상생물인 P. piscicida를 정확하게 정성 및 정량분석이 가능함을 의미한다. 개발된 real-time PCR 기법의 현장적용 결과, 광학 현미경상에서는 탐지할 수 없었던 P. piscicida를 서해(김제, 목포)와 동해(강릉) 시료에서 검출하였다. 또한, 시화호 시료를 이용한 P. piscicida개체군 동태 조사에서 다른 정점에 비해 염분도가 상대적으로 낮았던(${\leq}15psu$), St. 1에서 2007년 6, 7, 8월에 세포밀도의 피크가 관찰되었다. 본 연구에서 개발된 EvaGreen 기반 real-time PCR 기법은 현장에서 P. piscicida를 탐지 및 정량 분석 하는데 성공하였으며, 이는 향후 이들 종에 대한 다양한 생태학적 연구에 활용될 것으로 사료된다.

Electrical Characterization of Ultrathin Film Electrolytes for Micro-SOFCs

  • Shin, Eui-Chol;Ahn, Pyung-An;Jo, Jung-Mo;Noh, Ho-Sung;Hwang, Jaeyeon;Lee, Jong-Ho;Son, Ji-Won;Lee, Jong-Sook
    • 한국세라믹학회지
    • /
    • 제49권5호
    • /
    • pp.404-411
    • /
    • 2012
  • The reliability of solid oxide fuel cells (SOFCs) particularly depends on the high quality of solid oxide electrolytes. The application of thinner electrolytes and multi electrolyte layers requires a more reliable characterization method. Most of the investigations on thin film solid electrolytes have been made for the parallel transport along the interface, which is not however directly related to the fuel cell performance of those electrolytes. In this work an array of ion-blocking metallic Ti/Au microelectrodes with about a $160{\mu}m$ diameter was applied on top of an ultrathin ($1{\mu}m$) yttria-stabilized-zirconia/gadolinium-doped-ceria (YSZ/GDC) heterolayer solid electrolyte in a micro-SOFC prepared by PLD as well as an 8-${\mu}m$ thick YSZ layer by screen printing, to study the transport characteristics in the perpendicular direction relevant for fuel cell operation. While the capacitance variation in the electrode area supported the working principle of the measurement technique, other local variations could be related to the quality of the electrolyte layers and deposited electrode points. While the small electrode size and low temperature measurements increaseed the electrolyte resistances enough for the reliable estimation, the impedance spectra appeared to consist of only a large electrode polarization. Modulus representation distinguished two high frequency responses with resistance magnitude differing by orders of magnitude, which can be ascribed to the gadolinium-doped ceria buffer electrolyte layer with a 200 nm thickness and yttria-stabilized zirconia layer of about $1{\mu}m$. The major impedance response was attributed to the resistance due to electron hole conduction in GDC due to the ion-blocking top electrodes with activation energy of 0.7 eV. The respective conductivity values were obtained by model analysis using empirical Havriliak-Negami elements and by temperature adjustments with respect to the conductivity of the YSZ layers.

탐침형 정보 저장장치에 응용 가능한 강유전체 물질의 특성 연구 (Properties of Ferroelectric Materials Applicable to Nano-storage Media)

  • 최진식;김진수;황인록;변익수;김수홍;전상호;이진호;홍사환;박배호
    • 한국진공학회지
    • /
    • 제15권2호
    • /
    • pp.173-179
    • /
    • 2006
  • Pulsed laser deposition 방법으로 증착한 $PbZr_{0.3}Ti_{0.7}O_{3}$ (PZT)박막의 구조적, 전기적 성질에 대한 연구를 하였다. PZT 박막은 $LaAlO_3$ 기판위에 동일한 조건으로 증착된 $LaMnO_3$ (LMO) 산화물을 하부 전극으로 하여 증착시간을 변화시키며 증착하였다. High-resolution x-ray diffraction 결과를 통해 LMO 하부 전극과 PZT 박막이 방향성 있게 자란 것을 확인할 수 있었고 박막의 두께는 field-emission scanning electron microscope을 통하여 측정할 수 있었다. 또한 우리는 atomic force microscopy을 이용하여 박막의 표면 거칠기를 구하였고 국소적인 범위의 전기적 특성은 piezoelectric force microscopy 모드를 이용하여 측정하였다. 그 결과 PZT/LMO 구조는 나노 스토리지의 미디어로 쓰이기 위해 필요한 성질들을 갖추었음을 알 수 있었다.

BIOLOGICAL RESPONSES OF OSTEOBLAST-LIKE CELLS TO DIFFERENT TITANIUM SURFACE BY ANODIZING MODIFICATION

  • Kim Myung-Joo;Kim Chang-Whe;Lim Young-Jun;Park Hyun-Joo
    • 대한치과보철학회지
    • /
    • 제43권6호
    • /
    • pp.751-763
    • /
    • 2005
  • Statement of problem. To improve a direct implant fixation to the bone, various strategies have been developed focusing on the surface of materials. The surface quality of the implant depends on the chemical, physical, mechanical and topographical properties of the surface. The different properties will interact with each other and a change in thickness of the oxide layer may also result in a change in surface energy, the surface topography and surface, chemical composition. However, there is limited the comprehensive study with regard to changed surface and biologic behavior of osteoblast by anodization. Purpose of study. The aim of this study was to analyze the characteristics of an oxide layer formed and to evaluate the cellular biologic behaviors on titanium by anodic oxidation (anodization) by cellular proliferation, differentiation, ECM formation and gene expression. And the phospholipase activity was measured on the anodized surface as preliminary study to understand how surface properties of Ti implant are transduced into downstream cellular events. Methods and Materials. The surface of a commercially pure titanium(Grade 2) was modified by anodic oxidation. The group 1 samples had a machined surface and other three experimental specimens were anodized under a constant voltage of 270 V(Group 2), 350 V(Group 3), and 450 V(Group 4). The specimen characteristics were inspected using the following five categories; the surface morphology, the surface roughness, the thickness of oxide layer, the crystallinity, and the chemical composition of the oxide layer. Cell numbers were taken as a marker for cell proliferation. While the expression of alkaline phosphatase and Runx2 (Cbfa1) was used as early differentiation marker for osteoblast. The type I collagen production was determined, which constitutes the main structural protein of the extracellular matrix. Phospholipase $A_2$ and D activity were detected. Results. (1) The anodized titanium had a porous oxide layer, and there was increase in both the size and number of pores with increasing anodizing voltage. (2) With increasing voltage, the surface roughness and thickness of the oxide film increased significantly (p<0.01), the $TiO_2$phase changed from anatase to rutile. During the anodic oxidization, Ca and P ions were more incorporated into the oxide layer. (3) The in vitro cell responses of the specimen were also dependant on the oxidation conditions. With increasing voltage, the ALP activity, type I collagen production, and Cbfa 1 gene expression increased significantly (p<0.01), while the cell proliferation decreased. (4) In preliminary study on the relation of surface property and phospholipase, PLD activity was increased but $PLA_2$ activity did not changed according to applied voltage. Conclusion. The anodized titanium shows improved surface characteristics than the machined titanium. The surface properties acquired by anodization appear to give rise more mature osteoblast characteristics and might result in increased bone growth, and contribute to the achievement of a tight fixation. The precise mechanism of surface property signaling is not known, may be related to phospholipase D.

비차폐 환경에서의 고온초전도 SQUID 2차 미분기의 특성연구 (High-$T_c$ 2nd-order SQUID Gradiometer for Use in Unshielded Environments)

  • 박승문;강찬석;이순걸;유권규;김인선;박용기
    • Progress in Superconductivity
    • /
    • 제5권1호
    • /
    • pp.50-54
    • /
    • 2003
  • We have fabricated $∂^2$$B_{z}$ /$∂x^2$ type planar gradiometers and studied their properties in operation under various field conditions. $YBa_2$$Cu_3$$O_{7}$ film was deposited on $SrTiO_3$ (100) substrate by a pulsed laser deposition (PLD) system and patterned into a device by the photolithography with ion milling technique. The device consists of 3 pickup loops designed symmetrically Inner dimension and the width of the square side loops are 3.6 mm and 1.2 mm, respectively, and the corresponding dimensions of the center loop are 2.0 mm and 1.13 mm. The length of baseline gradiometer is 5.8 mm. Step-edge junction width is 3.0 $\mu\textrm{m}$ and the hole size of the SQUID loop is 3 $\mu\textrm{m}$ ${\times}$ 52 $\mu\textrm{m}$. The SQUID inductance is estimated to be 35 pH. The device was formed on a 20 mm ${\times}$ 10 mm substrate. We have tested the behavior of the device in various field conditions. The unshielded gradiometer was stable under extremely hostile conditions on a laboratory bench. Noise level 0.45 pT/$\textrm{cm}^2$/(equation omitted)Hz and 0.84 pT/$\textrm{cm}^2$/(equation omitted)Hz at 1 Hz for the shielded and the unshielded cases, which correspond to equivalent field noises of 150 fT/(equation omitted)Hz and 280 fT/(equation omitted)Hz, respectively. In spite of the short baseline of 5.8 mm, the high common-mode-rejection-ratio of the gradiometer, $10^3$, allowed us to successfully record magnetocardiogram of a human subject, which demonstrates the feasibility of the design in biomagnetic studies.

  • PDF

전산화 단층검사 시 Bismuth와 CARE kV System을 이용한 선량 저감화에 대한 연구 (Research on Dose Reduction During Computed Tomography Scanning by CARE kV System and Bismuth)

  • 곽영곤;김종일;정성표
    • 한국콘텐츠학회논문지
    • /
    • 제14권8호
    • /
    • pp.233-242
    • /
    • 2014
  • 본 논문에서는 전산화 단층검사 시 방사선 투과 물질로 방사선량을 흡수하여 피폭 선량을 감소시키는 물질로 알려진 차폐용 Bismuth(비스무스)와 CARE kV(Automated Dose-Optimized Selection of X-ray Tube Voltage)을 사용하여 유용성을 평가하였다. 방사선 감수성이 높은 기관인 수정체(안와), 갑상선, 가슴(유방), 생식기의 선량 감소 효과와 각 기관의 심부선량 차폐 효과를 평가하기 위해 Rando Phantom과 유리 선량계를 이용하여 Bismuth 사용 전 후와, CARE kV의 적용에 따른 선량 감소 효과를 비교해 보았다. 그 결과, 뇌혈관 검사 시 CARE kV을 단독 설정한 검사 방법의 선량이 가장 적었으며, CARE kV 사용여부에 따라 63%의 선량 감소 효과가 있었다. 경동맥 검사 시 CARE kV+Bismuth의 설정 방법에서 선량이 13% 증가하였다. 심혈관 검사 시 CARE kV+Bismuth의 설정 방법이 31% 선량 감소 효과가 있었다. 하지 혈관 검사 시 Bismuth 전체의 설정 방법이 가장 선량이 적게 측정되었지만, 영상 평가 기준에 부적합 하였다. CARE kV을 설정한 검사 방법과는 약 9%의 선량 감소 효과가 있었다.

Cooperation of $G{\beta}$ and $G_{\alpha}q$ Protein in Contractile Response of Cat Lower Esophageal Sphincter (LES)

  • Sohn, Uy-Dong;Lee, Tai-Sang
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제7권6호
    • /
    • pp.349-355
    • /
    • 2003
  • We previously shown that LES contraction depends on $M_3$ receptors linked to PTX insensitive $G_q$ protein and activation of PLC. This results in production of $IP_3$, which mediates calcium release, and contraction through a CaM dependent pathway. In the esophagus ACh activates $M_2$ receptors linked to PTX sensitive $G_{i3}$ protein, resulting in activation of PLD, presumably, production of DAG. We investigated the role of PLC isozymes which can be activated by $G_q$ or $G{\beta}$ protein on ACh-induced contraction in LES and esophagus. Immunoblot analysis showed the presence of 3 types of PLC isozymes, $PLC-{\beta}1$, $PLC-{\beta}3$, and $PLC-{\gamma}1$, but not $PLC-{\beta}2$, $PLC-{\beta}4$, $PLC-{\gamma}2$, $PLC-{\delta}1$, and $PLC-{\delta}2$ from both LES and esophageal muscle. ACh produced contraction in a dose dependent manner in LES and esophageal muscle cells obtained by enzymatic digestion with collagenase. $PLC-{\beta}1$ or $PLC-{\beta}3$ antibody incubation reduced contraction in response to ACh in LES but not in esophageal permeabilized cells, but $PLC-{\gamma}1$ antibody incubation did not have an inhibitory effect. The inhibition by $PLC-{\beta}1$ or $PLC-{\beta}3$ antibody on Ach-induced contraction was antibody concentration dependent. The combination with $PLC-{\beta}_1$ and $PLC-{\beta}_3$ antibody completely abolished the contraction, suggesting that $PLC-{\beta}1$ and $PLC-{\beta}3$ have a synergism to inhibit the contraction in LES. $PLC-{\beta}1$, -${\beta}3$ or -${\gamma}1$ antibody did not reduce the contraction of LES cells in response to DAG ($10^{-6}$ M), suggesting that this isozyme of PLC may not activate PKC. When $G_{q/11}$ antibody was incubated, the inhibitory effect of the incubation of PLC ${\beta}3$, but not of PLC ${\beta}_1$ was additive (Fig. 6). In contrast, when $G_{\beta}$ antibody was incubated, the inhibitory effect of the incubation of PLC ${\beta}_1$, but not of PLC ${\beta}_3$ was additive. This data suggest that $G_{q/11}$/11 or $G{\beta}$ may activate cooperatively different PLC isozyme, $PLC{\beta}_1$ or $PLC{\beta}_3$ respectively.