• 제목/요약/키워드: PLB convection

검색결과 1건 처리시간 0.012초

지역난방 첨두부하보일러 대류부 부식 파손 분석 (Corrosion Failure Analysis of the Convection Part of District Heating Peak Load Boiler)

  • 김영수;채호병;홍민기;송민지;조정민;김우철;하태백;이수열
    • Corrosion Science and Technology
    • /
    • 제18권2호
    • /
    • pp.55-60
    • /
    • 2019
  • Corrosion failure in the convection part of peak load boiler (PLB) of the district heating system led to water leakage. Herein, Internal Rotary Inspection System (IRIS) inspection was employed to examine wall thinning and the cause of leakage in the flue tube. The corrosive products of the turbulator and tube were investigated using scanning electron microscope combined with energy dispersive spectroscopy, X-ray diffraction, and inductively coupled plasma (ICP). Majority of the serious corrosion damage was observed near the turbulator located in the upper flue tube. ICP analysis of the boiler water revealed oxide formation of sodium chloride in the lower end part of the flue tube. A cross-sectional view of the turbulator revealed the presence of double-layers of the oxide film, indicating environmental change during operation associated with water leakage. The outer surface of the turbulator consisted of the acid oxides such as $NO_x$ and $SO_x$ along with sodium and chloride ions. Dew-point corrosion is hypothesized as the main cause for the formation of acid oxides in the region of contact of the flue tube and the turbulator.