• Title/Summary/Keyword: PLANTAR FOOT

Search Result 339, Processing Time 0.032 seconds

Analysis of Biomechanical Effect of the Subtalar Sling Ankle Taping (거골하 관절 현수 테이핑의 생체 역학적 효과 분석)

  • Choi, Mun-Suk;Jeon, Hye-Seon;Kim, Young-Ho
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.1
    • /
    • pp.135-144
    • /
    • 2007
  • The purpose of this study was to identify the effect of the subtalar sling ankle taping, by measuring changes in peak plantar pressure and subtalar angle during jump landing and walking in healthy subjects with subtalar sling ankle taping applied of the ankle joint. Fifty healthy subjects(8 males and 7 female, aged 22 to 25) were randomly divided into a participated in this study. They were free of musculoskeletal injury and neurologic deficit in lower extremity. The subjects were asked to perform 5M walking and single leg jump landing by under the guidance of physical therapists. Subtalar motions were typically measured as the angle made between the posterior aspect of the calcaneous and the posterior aspect of the lower leg during walking with taping or not. This measurement were made using a video system (30Hz sampling rate, rectified 60 Hz sampling rate). At the same time, peak lateral and vertical pressure were investigated using pressure distribution platforms(MatScan system) under foot during walking and single leg jump landing with taping or not. Statistical analysis was done by paired t-test and intraclass correlation coefficient [ICC(3.1)], using software SPSS. We have recently demonstrated significantly altered patterns of subtalr joint and peak plantar pressure when applied subtalar sling ankle taping(p<.05). Inversion angle of subtalar joint significantly decreased with taping(p<.05). The result suggest that pressure patterns observed in subjects are likely to result due to significant decrease in stress on ankle joint structures during jump landing and walking. Also, the result that the subtalar sling ankle taping procedure provides greater restiction of motion associated with ankle inversion. However, this study involved asymptomatic subjects without history of ankle inversion injury, further research is needed to assess the motion restraining effect of the subtalar sling ankle taping in subjects with lateral ankle instability.

A Comparative Study on Biomechanical Variables of Elderly Women and Elderly Women at Risk of Fall in Gait by Environmental Conditions (환경조건에 따른 보행 시 낙상 위험 여성 노인과 정상 여성 노인의 생체역학적 변인 비교 연구)

  • Kim, Tae-Whan;Kim, Dae-Hyun;Min, Seok-Ki;Cho, Eun-Hyung;Lee, Jin-Seok
    • Korean Journal of Applied Biomechanics
    • /
    • v.31 no.3
    • /
    • pp.189-198
    • /
    • 2021
  • Objective: The aim of this study is to investigate the effect of biomechanical variables on gait according to indoor and outdoor environmental conditions in elderly women at risk of falling. Method: 26 elderly women aged 70 years or older, and consisted of 13 elderly people with a walking speed of less 1.0 m/s and 13 people in the fall risk group as normal groups. Depending on the purpose of the study, physical examination and psychological questionnaire were prepared, and then walking was performed in an indoor/outdoor environment, and the gait pattern, muscle activity, and plantar pressure results were compared and analyzed in the elderly females through a 2 group × 2 environment 2-way repeted ANOVA analysis. Results: The gait variable showed an interaction effect the cadence. The muscle variables showed interaction effects in the rectus femoris and tibialis anterior muscles, and the interaction effects of the plantar pressure variables were confirmed in the forefoot and midfoot of the contact area, and the midfoot of the mean pressure. Conclusion: These results indicate that both groups are exposed to falls risk when gait in an outdoor environment, but the fall risk group has a higher risk of falls in both the gait pattern, muscle activity, and plantar pressure variables. The results of this study are considered to be helpful as basic data and development of exercise programs to prevent falls.

Analysis of Clinical and Radiographic Outcome of the Reconstructive Surgery for the Cavovarus Foot Deformity (요내반족 변형에 대한 재건수술의 임상적 및 방사선학적 결과 분석)

  • Jung, Hong-Geun;Park, Jae-Yong;Lee, Dong-Oh;Eom, Joon-Sang;Chung, Seung-Hee
    • Journal of Korean Foot and Ankle Society
    • /
    • v.18 no.2
    • /
    • pp.62-67
    • /
    • 2014
  • Purpose: Reconstructive surgeries for equinocavovarus foot deformities are quite variable, including hind-midfoot osteotomy or arthrodesis, soft tissue procedure, tendon transfers, etc. Comprehensive evaluation of the deformity and its etiology is mandatory for achievement of successful deformity correction. Few studies in this field have been reported. We report on the clinical and radiographic outcome of reconstruction for cavovarus foot deformities. Materials and Methods: The study is based on 16 feet with cavovarus foot deformities that underwent bony and soft tissue reconstructive surgery from 2004 to 2008. We evaluated the etiologies, varieties of surgical procedures performed, pain score, functional scores, and patient satisfaction and measured the radiographic parameters. Results: The average age at the time of surgery was 39.4 years old, with a male/female ratio of 9/4 and an average follow-up period of 23.9 months (range, 12~49 months). The etiologies of the cavovarus deformity were idiopathic 7 feet, residual poliomyelitis 5 feet, Charcot-Marie-Tooth disease 2 feet, and Guillain-Barre syndrome and hemiplegia due to cerebrovascular accident sequela 1 foot each. Lateral sliding calcaneal osteotomies were performed in 12 feet (75%), followed by Achilles tendon lengthening and plantar fascia release in 11 feet (69%), and first metatarsal dorsiflexion osteotomy/arthrodesis and tendon transfer in 10 feet (63%). Visual analogue scale pain score showed improvement, from an average of 4.2 to 0.5 points. American Orthopaedic Foot and Ankle Society ankle-hindfoot score showed significant improvement, from 47.8 to 90.0 points (p<0.05). All patients were satisfied. Ankle range of motion improved from $27.5^{\circ}$ to $46.7^{\circ}$. In radiographic measurements, calcaneal pitch angle improved from $19.1^{\circ}$ to $15.8^{\circ}$, Meary angle from $13.0^{\circ}$ to $9.3^{\circ}$, Hibb's angle from $44.3^{\circ}$ to $37.0^{\circ}$, and tibio-calcaneal axis angle from varus $17.5^{\circ}$ to varus $1.5^{\circ}$ Conclusion: We achieved successful correction of cavovarus foot deformities by performing appropriate comprehensive reconstructive procedures with improved functional, radiographic measures and high patient satisfaction.

Anatomical Observation on Components Related to Foot Gworeum Meridian Muscle in Human

  • Park, Kyoung-Sik
    • The Journal of Korean Medicine
    • /
    • v.32 no.3
    • /
    • pp.1-9
    • /
    • 2011
  • Objectives: This study was carried out to observe the foot gworeum meridian muscle from a viewpoint of human anatomy on the assumption that the meridian muscle system is basically matched to the meridian vessel system as a part of the meridian system, and further to support the accurate application of acupuncture in clinical practice. Methods: Meridian points corresponding to the foot gworeum meridian muscle at the body surface were labeled with latex, being based on Korean standard acupuncture point locations. In order to expose components related to the foot gworeum meridian muscle, the cadaver was then dissected, being respectively divided into superficial, middle, and deep layers while entering more deeply. Results: Anatomical components related to the foot gworeum meridian muscle in human are composed of muscles, fascia, ligament, nerves, etc. The anatomical components of the foot gworeum meridian muscle in cadaver are as follows: 1. Muscle: Dorsal pedis fascia, crural fascia, flexor digitorum (digit.) longus muscle (m.), soleus m., sartorius m., adductor longus m., and external abdominal oblique m. aponeurosis at the superficial layer, dorsal interosseous m. tendon (tend.), extensor (ext.) hallucis brevis m. tend., ext. hallucis longus m. tend., tibialis anterior m. tend., flexor digit. longus m., and internal abdominal oblique m. at the middle layer, and finally posterior tibialis m., gracilis m. tend., semitendinosus m. tend., semimembranosus m. tend., gastrocnemius m., adductor magnus m. tend., vastus medialis m., adductor brevis m., and intercostal m. at the deep layer. 2. Nerve: Dorsal digital branch (br.) of the deep peroneal nerve (n.), dorsal br. of the proper plantar digital n., medial br. of the deep peroneal n., saphenous n., infrapatellar br. of the saphenous n., cutaneous (cut.) br. of the obturator n., femoral br. of the genitofemoral n., anterior (ant.) cut. br. of the femoral n., ant. cut. br. of the iliohypogastric n., lateral cut. br. of the intercostal n. (T11), and lateral cut. br. of the intercostal n. (T6) at the superficial layer, saphenous n., ant. division of the obturator n., post. division of the obturator n., obturator n., ant. cut. br. of the intercostal n. (T11), and ant. cut. br. of the intercostal n. (T6) at the middle layer, and finally tibialis n. and articular br. of tibial n. at the deep layer. Conclusion: The meridian muscle system seemed to be closely matched to the meridian vessel system as a part of the meridian system. This study shows comparative differences from established studies on anatomical components related to the foot gworeum meridian muscle, and also from the methodical aspect of the analytic process. In addition, the human foot gworeum meridian muscle is composed of the proper muscles, and also may include the relevant nerves, but it is as questionable as ever, and we can guess that there are somewhat conceptual differences between terms (that is, nerves which control muscles in the foot gworeum meridian muscle and those which pass nearby) in human anatomy.

Assessment of Elderly's Isokinetic Muscle Function, Flexibility and Balance in a Region of Seoul (서울 일부 지역 노인들의 등속성 근기능, 유연성, 균형성 측정 및 평가)

  • Kim, Suk-Won;Sohn, Jee-Hoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.2
    • /
    • pp.37-44
    • /
    • 2016
  • The aim of the present study was to compare the strength, balance, and flexibility across two age groups (older adults vs. young adults). The isokinetic muscle function, ankle ROM, trunk forward flexibility, stability, and antropometric data for the elderly and 46 university students were collected. The results indicated that male older adults possessed relatively low flexibility (2.97cm) among the groups and showed better stability in the right foot than in the left foot and $35^{\circ}$ of plantar flexion ROM, which was not in the normal range. Their peak strength at the knee joint was below 50% of their counterpart. They revealed a hamstring deficit of 18.55%, ankle eversion deficit of 23.08%, and ankle inversion deficit of 19.19%. The results indicated that female older adults possessed comparable flexibility compared to female young adults. The reciprocal muscle strength ratio of both knees was under 50%, and the deficit was 14.32% (extension) and 19.73% (flexion). The ankle plantar flexion peak torque was approximately 62% (left) and 73% (right) of WS's. The ankle dorsi flexion deficit was 25.05% and the plantar flexion was 26.86%. The eversion deficit was 19.97% and the inversion was 21.09%. These results will be significant in establishing an elderly fitness enhancement program and policy.

Effects of Beraprost Sodium Evaluated by Digital Infrared Thermal Imaging in Diabetic Patients with Peripheral Arterial Disease (당뇨병성 말초혈관병증 환자에게 Beraprost Sodium이 미치는 영향에 대한 적외선 체열검사를 통한 연구)

  • Park, Hyun Woo;Soh, Jae Wan;Park, Seong Hyeon;Jeong, Jae Jung
    • Journal of Korean Foot and Ankle Society
    • /
    • v.22 no.3
    • /
    • pp.105-110
    • /
    • 2018
  • Purpose: This study examined the effects of beraprost sodium on digital infrared thermal images in patients with peripheral arterial disease caused by type 2 diabetes mellitus. Materials and Methods: Twenty-five diabetic patients with peripheral arterial disease were treated with beraprost sodium in a prospective, multicenter, cohort study from February 2013 to December 2014. Beraprost sodium ($40{\mu}g$) was administered orally 3 times daily ($120{\mu}g/day$) for 6 months. The visual analogue scale (VAS) and digital infrared thermal imaging (DITI) were performed to compare the blood flow improvement between before and after dosing. Results: Among the 25 patients included in the evaluation, 22 patients completed the study. A significant increase in body temperature was observed in the front and left side, particularly in the plantar side in DITI compared to that before and after administration. An increase in body temperature was observed at the frontal part from $28.1^{\circ}C{\pm}2.3^{\circ}C$ to $29.1^{\circ}C{\pm}2.1^{\circ}C$ (p=0.021), at the left side from $27.8^{\circ}C{\pm}2.4^{\circ}C$ to $28.6^{\circ}C{\pm}1.9^{\circ}C$ (p=0.028), at the plantar part at $24.0^{\circ}C{\pm}1.5^{\circ}C$, and at the plantar part at $27.1^{\circ}C{\pm}2.4^{\circ}C$ (p<0.01). The VAS decreased significantly from $5.4{\pm}1.3$ to $2.7{\pm}2.0$ after 6 months of treatment (p<0.01). Conclusion: Beraprost sodium is a safe and easy-to use oral medication for diabetes peripheral arterial disease. It can be expected to increase the blood flow and decrease the lower extremity pain statistically after being taken for 6 months.

Change of Tibio-Talar Motion After Total Ankle Replacement (족관절 인공관절 치환술 후 족관절 운동범위의 변화)

  • Suh, Jin-Soo;Saltzman, Charles L.
    • Journal of Korean Foot and Ankle Society
    • /
    • v.10 no.1
    • /
    • pp.92-95
    • /
    • 2006
  • Purpose: Ankle fusion that is operated on severe ankle arthritis has its weakness in that normal walking is impossible, even though the result is pretty good. As a alternative choice, total ankle replacement pursues the longer survivorship with material improvement. However, it is not yet known how much range of motion is possible after the replacement, or how it has changed overtime. Therefore, we need an analyzation for that. Materials and Methods: A retrospective review of sixty-seven patients undergoing STAR total ankle replacement at our institution between 1998 and 2002 was conducted. Of those, twenty-six (39%) had complete sets of full dorsiflexion and plantar flexion lateral radiographs both between "immediate" postop and at a minimum of 2-years follow-up and no revision procedure during that time. The mean age of these patients was 63.2 years when the surgery was done; the etiology of arthrosis was 21(81%) post-traumatic/degenerative, 4 rheumatoid and 1 psoriatic. Results: Average "immediate" ankle range of motion was $15.9^{\circ}$, and total foot (non-ankle) motion was $20.6^{\circ}$. At one, two, and three years the average ankle and total foot ranges of motion were $17.4^{\circ}$, $17.6^{\circ}$, $15.6^{\circ}$ and $21.0^{\circ}$, $22.0^{\circ}$, $21.2^{\circ}$ respectively. Statistically there was no significant difference between "immediate" postop motion and one to three years postop (all p>0.05). Conclusion: The range of motion after the STAR total ankle replacement is maintained from the "immediate" postoperative range of motion, but not increased, in the 1-3 year post replacement period.

  • PDF

Clinical Results after Closed Reduction and Internal Fixation for Unstable Subtle Injuries of Lisfranc Joint (초기 진단에 어려움이 있는 불안정성 족근 중족 관절 미세 손상에 대한 도수 정복 및 내고정술 후 임상적 결과)

  • Yu, Sun-O;Park, Yong-Wook;Kim, Joo-Sung;Lee, Gi-Jun
    • Journal of Korean Foot and Ankle Society
    • /
    • v.8 no.1
    • /
    • pp.71-75
    • /
    • 2004
  • Purpose: The purpose of this study was to evaluate retrospectively the clinical results of closed reduction and percutaneous screw fixation for unstable injuries on stress radiographs in subtle injuries of Lisfranc joint. Materials and Methods: From June 1997 to March 2003, 6 cases of unstable injuries on stress radiograph in subtle injuries of Lisfranc joint were treated by percutaneous cannulated screw fixation after closed reduction. All cases were injuried by indirect force (twisting injury). The average diastasis between the 1st and 2nd metatarsal base was 3 mm (2-4 mm) on initial nonweight bearing AP radiograph. The average follow-up period was 20 months. Clinical evaluation was assessed according to the American Orthopedic Foot and Ankle Society (AOFAS) midfoot score. Results: The AOFAS midfoot score was average 86 (80-90) points. The average diastasis between 1st and 2nd metatarsal base was 2 mm (1-3 mm) on weight bearing AP radiograph in final follow up. The final diastasis was increased slightly than diastasis in initial postoperative radiographs. But the clinical results were good. There was no correlation between the degree of diastasis and the clinical results. On weight bearing lateral radiograph, the average difference with normal foot in the distance between plantar aspect of 5th metatarsus and medial cuneiform was 2 mm (0-3 mm). One case had mild arthritic change on the radiographs. Conclusion: When the Lisfranc injuries, especially in the subtle injuries were suspicious, the stress views are helpful to assess stability of the Lisfranc injuries and planning of treatment. For unstable injuries on stress radiographs in subtle injuries of Lisfranc joint, closed reduction and percutaneous screw fixation is useful method to expect good clinical results.

  • PDF

A study on the traceability and uncertainty of skin hydration measurement on the sole of the foot

  • Yang, Gi-Young;Choi, Ji-Won;Chae, Han;Lee, Byung-Ryul
    • The Journal of Korean Medicine
    • /
    • v.38 no.4
    • /
    • pp.55-61
    • /
    • 2017
  • Objectives: In order to accurately measure skin moisture and accumulate normal skin moisture data, analyzing the uncertainty of the skin moisture measurement and establishing standard reference data is essential. It helps to evaluate the skin's condition and has great significance in diagnosis and treatment. In this study, the traceability of the equipment and the uncertainty of the results were analyzed for their potential use in the field of Korean medicine. The data was collected measuring skin moisture on the sole of the foot. Methods: One professional measured the moisture of the adult male's foot 10 times following a determined protocol. The standard uncertainty of repeated measurements was calculated from the mean value of 10 repeated measurements. Ten trainee participants also measured the adult male's foot following a determined protocol. The standard uncertainty by tester was calculated from the value of repeated measurements. Results: As a result of analyzing the difference between the mean and standard uncertainties in both the expert and trainees, it was confirmed that the variance in this study did not satisfy the normal distribution. In addition, the Mann-Whitney U-test was carried out, and it was found that there was no significant difference in the measured values of the two groups. The authorized uncertainty of measurements and traceability of all the equipment was not confirmed. Conclusions: This paper establishes the basis for later measurement-equipment research to provide the objective indicators to approach the dryness of plantar skin from dehydration, the Korean medicine perspective.

The Analysis of Center of Pressure(COP) Displacement under Loading Position during Walking (보행 시 부하 위치에 따른 족저압 중심(COP) 이동 분석)

  • Park, Soo-Jin;Kim, Jin-Sang
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.5 no.1
    • /
    • pp.15-24
    • /
    • 2010
  • Purpose : The purpose of this study was to investigate the effect of loading position on plantar center of pressure(COP) displacement when carrying a schoolbag during walking. Methods : Forty-four normal subjects were randomly assigned to five groups according to the method of carrying a schoolbag. The carrying a schoolbag methods were classified into five conditions: no bag (condition 1), a backpack (condition 2), a shoulder bag (condition 3), a cross bag (condition 4), a one-hand bag (condition 5). COP displacement such as anteroposterior distance and mediolateral distance of COP were measured with F-scan system. The repeated one-way analysis of variance (ANOVA) and independent t-test were used to confirm the statistical significance. Results : In the comparison of parameters of COP displacement between conditions, anteroposterior distance and mediolateral distance in the left foot and mediolateral distance in the right foot were not significantly different(p>.05), but anteroposterior diatance in the right foot was significantly different(p>.05). Between left and right foot, at condition 1 and 5 the mediolateral distance of COP was significantly different(p<.05) but anteroposterior distance at condition 1 and 5, anteroposterior distance and mediolateral distance of COP at condition 2, 3 and 4 were not significantly different(p>.05). Conclusion : These findings showed that the various loading position by five types of carrying a schoolbag didn't have influence significantly on COP displacement on during walking because of mechanism of postural adaption.