• Title/Summary/Keyword: PIV System

Search Result 382, Processing Time 0.024 seconds

Flow Visualization of Pulsatile Flow in a Branching Tube using the PIV System and Numerical Analysis (PIV와 수치해석을 이용한 분지관내 맥동유동의 가시화)

  • Roh, Hyung-Woon;Suh, Sang-Ho;Yoo, Sang-Sin
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.535-540
    • /
    • 2000
  • The objective of the present study is to visualize the pulsatile flow fields by using three-dimensional computer simulation and the PIV system. A closed flow loop system was built for the steady and unsteady experiments. The Harvard pulsatile pump was used to generate the pulsatile pressure and velocity waveforms. Conifer powder as the tracing particles was added to water to visualize the flow field. Two consecutive particle images were captured by a CCD camera for the image processing. The cross-correlation method in combination with the moving searching area algorithm was applied for the image processing of the flow visualization. The pulsatile flow fields were visualized effectively by the PIV system in conjunction with the applied algorithm. The range validation and the area interpolation methods were used to obtain the final velocity vectors with high accuracy. The finite volume predictions were used to analyze three-dimensional flow patterns in the bifurcation model. The results of the PIV experiment and the computer simulation are in good agreement and the results show the recirculation zones and formation of the paired secondary flow distal to the apex of the bifurcated model. The results also show that the branch flow is pushed strongly to the inner wall due to the inertial force effect and helical motions are generated as the flow proceeds toward the outer wall.

  • PDF

Visualization of Three-Dimensional Pulsatile Flow in a Branching Model using the High-Resolution PIV System (고해상 PIV시스템을 이용한 분지관내3차원 맥동유동 가시화)

  • Roh, Hyung-Woon;Suh, Sang-Ho;Choi, Jin-Yong
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.765-768
    • /
    • 2003
  • The objective of the present study was to visualize the pulsatile flow field in a branching model by using the high-resolution PIV system. A bifurcated flow system was built for the experiments in the pulsatile flow. Harvard pulsatile pump was used to generate the pulsatile velocity waveforms. Conifer powder as the tracing particles was added to water to visualize the flow fields. Two consecutive particle images at several cross sections of the flow filed were captured by the CCD cameras ($1K{\ast}1K$ and $640{\ast}480$). The results after the image processing clearly showed the recirculation zones and the formation of the paired secondary flows from the distal to the apex in the bifurcated model. The results also indicated that the flow velocities in the inner wall moved faster than those in the outer wall due to the inertial force effects and the helical motions generated in the branch flows as the flow proceeded toward the outer wall. While the PIV images from the $1K{\ast}1K$ camera were closer to the simulation results thantheimagesfromthe640${\ast}$480camera,bothresultsofthePIVexperimentsusingthetwocamerasgenerallyagreed quitewellwiththeresultsfromthenumericalsimulation.

  • PDF

Three-Dimensional Flow Visualization for the Steady and Pulsatile Flows in a Branching Model using the High-Resolution PIV System

  • Suh, Sang-Ho;Roh, Hyung-Woon
    • International Journal of Vascular Biomedical Engineering
    • /
    • v.2 no.2
    • /
    • pp.27-32
    • /
    • 2004
  • The objective of the present study is to visualize the steady and pulsatile flow fields in a branching model by using a high-resolution PIV system. A bifurcated flow system was built for the experiments in the steady and pulsatile flows. Harvard pulsatile pump was used to generate the pulsatile velocity waveforms. Conifer powder as the tracing particles was added to water to visualize the flow fields. CCD cameras($1K{\times}1K$(high resolution camera) and $640{\times}480$(low resolution camera)) captured two consecutive particle images at once for the image processing of several cross sections on the flow system. The range validation method and the area interpolation method were used to obtain the final velocity vectors with high accuracy. The results of the image processing clearly showed the recirculation zones and the formation of the paired secondary flows from the distal to the apex of the branch flow in the bifurcated model. The results also indicated that the particle velocities at the inner wall moved faster than the velocities at the outer wall due to the inertial force effects and the helical motions generated in the branch flows as the flow proceeded toward the outer wall. Even though the PIV images from the high resolution camera were closer to the simulation results than the images from the low resolution camera at some locations, both results of the PIV experiments from the two cameras generally agreed quite well with the results from the computer simulations. Therefore, instead of using the expensive stereoscopic PIV or 3D PIV system, the three-dimensional flow fields in a bifurcated model could be easily and exactly investigated by this study.

  • PDF

A Study on the Improvement of PIV Performance (PIV의 성능개선에 관한 연구)

  • 이영호;김춘식;최장운
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.18 no.3
    • /
    • pp.34-42
    • /
    • 1994
  • The present study is aimed to improve the PIV performance by suggesting a two-frame particle identification technique and by introducing estimation method of wall pressure distribution from the velocity data. Adopted image processing system consists of one commercial image board slit into a personal computer, 2-D sheet light generator, flow picture recording apparatus and related particle identification software. A revised particle tracking method essential to PIV performance is obtained by particle centroid correlation pairing (CCP) and its effectiveness is ascertained by comparison with multi-frame identification.

  • PDF

Development of a High Resolution Digital Cinematic Particle Image Velocimetry (고해상도 Cinematic PIV의 개발)

  • Park, Gyeong-Hyeon;Kim, Gyeong-Cheon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.11
    • /
    • pp.1535-1542
    • /
    • 2001
  • A high resolution digital cinematic Particle Image Velocimetry(PIV) has been developed. The system consists of a high speed CCD camera, a continuous Ar-ion laser and a computer with camera controller. To improve the spatial resolution, we adopt a Recursive Technique for velocity interrogation. At first, we obtain a velocity vector fur a larger interrogation window size based on the conventional two-frame cross-correlation PIV analysis using the FFT algorithm. Based on the knowing velocity information, more spatially resolved velocity vectors are obtained in the next iteration step with smaller interrogation windows. When the correct velocity vector at the first step is found to be critical, a Multiple Correlation Validation(MCV) technique is applied to decrease the spurious vectors. The MCV technique turns out to improve SNR(Signal to Noise Ratio) of the correlation table. The developed cinematic PIV method has been applied to the measurement of the unsteady flow characteristics of a Rushton turbine mixer. A total of 3,245 instantaneous velocity vectors were successfully obtained with 4 ms time resolution. The acquired spatial resolution corresponds to the conventional high resolution digital PIV system using a 1K ${\times}$ 1K CCD camera.

Development of 3-D Stereo PIV by Homogeneous Coordinate System (호모지니어스 좌표계를 이용한 3차원 스테레오 PIV 알고리듬의 개발)

  • Kim, Mi-Young;Choi, Jang-Woon;Nam, Koo-Man;Lee, Young-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.6
    • /
    • pp.736-743
    • /
    • 2003
  • A process of 3-D particle image velocimetry, called here, as '3-D stereo PIV' was developed for the measurement of an illuminated slied section field of 3-D complex flows. The present method includes modeling of camera by a calibrator based on the homogeneous coordinate system, transfromation of the oblique-angled image to the right-angled image, identification of 2-D velocity vectors by 2-D cross-correlation equation, stereo matching of 2-D velocity vectors of two cameras, accurate calculation of 3-D velocity vectors by homogeneous coordinate system, removal of error vectors by a statistical method followed by a continuity equation criterior, and finally 3-D animation as the post processing. An experimental system was also used for the application of the proposed method. Three analog CCD cameras and an Argon-Ion Laser(300mW) for illumination were adopted to capture the wake flow behind a bluff obstacle.

Micro-PIV Analysis of Electro-osmotic Flow inside Microchannels (마이크로 채널 내부 전기삼투 유동에 대한 PIV유동 해석)

  • Kim Yang-Min;Lee Sang-Joon
    • Journal of the Korean Society of Visualization
    • /
    • v.1 no.2
    • /
    • pp.47-51
    • /
    • 2003
  • Microfluidic chips such as lab-on-a-chip (LOC) include micro-channels for sample delivery, mixing, reaction, and separation. Pressure driven flow or electro-osmotic flow (EOF) has been usually employed to deliver bio-samples. Having some advantages of easy control, the flow characteristics of EOF in microchannels should be fully understood to effectively control the electro-osmotic pump for bio-sam-pie delivery. In this study, a micro PIV system with an epifluorescence inverted microscope and a cooled CCD was used to measure velocity fields of EOF in a glass microchannel and a PDMS microchannel. The EOF velocity fields were changed with respect to electric charge of seeding particles and microchannel materials used. The EOF has nearly uniform velocity distribution inside the microchannel when pressure gradient effect is negligible. The mean streamwise velocity is nearly proportional to the applied electric field. Glass microchannels give better repeatability in PIV results, compared with PDMS microchannels which are easy to fabricate and more suitable for PIV experiments.

  • PDF

Development of angiographic PIV and performance evaluation (Angiographic PIV기법 개발 및 성능 평가)

  • Jung, Sung-Yong;Kim, Guk-Bae;Lim, Nam-Yun;Lee, Sang-Joon
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.683-686
    • /
    • 2008
  • To diagnose vascular diseases from the viewpoint of hemodynamics, detailed quantitative hemodynamic information of related blood flows with a high spatial resolution of tens micrometer and a high temporal resolution in the order of millisecond were required. For investigating the hemodynamic phenomena of vascular circulatory diseases, a new diagnosing technique combining a medical radiography and PIV method was newly developed. This technique consisted of a medical X-ray tube, an X-ray CCD camera, a shutter module for double pulse-type X-ray source, and a synchronizer. Through several preliminary tests, the feasibility of the angiographic PIV technique was verified. For in-vivo measurements to real blood flows, we developed tracer microcapsules which were optimized to this system by encapsulating a contrast material of iodine with a matrix material of PVA (polyvinylpyrrolidone). In near future, the angiographic PIV technique would be useful for diagnosing hemodynamic phenomena of vascular diseases and for their early detection.

  • PDF

Development of Hybrid Micro/Nano PIV system (하이브리드 마이크로/나노 PIV 시스템 개발)

  • Min, Young-Uk;Lee, Dong-Yeop;Kim, Kyung-Chun
    • Journal of the Korean Society of Visualization
    • /
    • v.8 no.4
    • /
    • pp.31-37
    • /
    • 2010
  • In this study, a novel hybrid micro/nano PIV system combining defocusing and TIRFM technique has been developed for the multiscale flow measurement. With the developed system, both far and near field velocity fields have been measured simultaneously in a 2D straight microchannel and the particle trajectories were extracted by the nearest tracking algorithm. The shear rate values taken from experimental results have been estimated by comparing with the analytical solution of 2D Poiseuille flow and it is confirmed that the result shows good agreement with the theoretical value.

Quantitative Flow Field Visualization of a Flow inside an Opaque Tube Using Angiographic PIV Method (X선관을 이용한 불투명한 물체 내부 유동의 정량적 가시화 연구)

  • Kim, Guk-Bae;Lim, Nam-Yun;Ryu, Jae-Chun;Yim, Dae-Hyun;Lee, Hyung-Koo;Lee, Sang-Joon
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2935-2940
    • /
    • 2007
  • To diagnose circulatory diseases in the viewpoint of hemodynamics, we need to get quantitative hemodynamic information of blood flows related with the vascular diseases with high spatial resolution of tens micrometer and high temporal resolution in the order of millisecond. For investigating in-vivo hemodynamic phenomena, a new diagnosing technique combining medical radiography and PIV method was newly proposed and developed. This angiographic PIV technique consists of a medical X-ray tube, an X-ray CCD camera, a shutter module for double pulses of X-ray, and a synchronizer. The feasibility of the angiographic PIV technique was tested and quantitative flow velocity field distribution of a flow inside an opaque conduit was acquired by the developed system. It can be used for measuring flow phenomena of nontransparent fluids inside opaque conduits.

  • PDF