• Title/Summary/Keyword: PIV System

Search Result 381, Processing Time 0.026 seconds

A Study on Fundamental Characteristics of Underwater Ram-Jet Propulsion by PIV (PIV에 의한 수중램제트추진의 기본특성에 관한 연구)

  • 양창조;김춘식;최민선;김진구;이영호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.24 no.3
    • /
    • pp.36-42
    • /
    • 2000
  • A fundamental experimental study for an alternative proposal to super-speed craft propulsion system called underwater ram-jet propulsion by high pressure air ejection as driving force was investigated. For basic study of the effects of ram-jet propulsion performance, a simple underwater ram-jet flow field was established and PIV(Particle Image Velocimetry) method was adopted to analyse the jet-induced flow appearing at ram intake, mixing chamber and nozzle. Some flow dynamics relating to the high-speed ram-jet effect were discussed for the basic understanding of the its propulsion principle.

  • PDF

Flow Analysis on Near Field of Elliptic Jet Using a Single-Frame PIV (고해상도 PIV 기법을 이용한 타원형 제트의 근접 유동장 해석)

  • Shin, Dae-Sig;Lee, Sang-Joon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.3
    • /
    • pp.459-466
    • /
    • 2000
  • Flow characteristics of turbulent elliptic jets were experimentally investigated using a single-frame PIV system. A sharp-edged elliptic nozzle with aspect ratio(AR) of 2 was tested and the experimental results were compared with those of circular jet having the same equivalent diameter($D_e$). The Reynolds number based on the nozzle exit velocity and nozzle equivalent diameter was about $1{\times}10^4$. The spreading rate along the major and minor axis are different remarkably. The jet half width along the major axis decreases at first and then increases with going downstream. But along the minor axis the jet width increases steadily. The elliptic jet of AR=2 has one switching points at $X/D_e=2$ within the near field. Turbulence properties are also found to be significantly different along the major and minor axis planes.

Thermal Mixing in a Microchannel (마이크로 채널에서의 열혼합 특성)

  • Park, Kyoung-Bae;Ahn, Joon;Kim, Byoung-Joon;Lee, Joon-Sik
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.585-588
    • /
    • 2008
  • Thermal mixing phenomena in a Y-type microchannel were investigated using a micro-PIV. Two inlet reservoirs of the microchannel were controlled individually so that the characteristics of thermal mixing in the channel with temperature difference were compared with those without the difference. The velocity field in the mixing process was measured using the micro-PIV system that includes an ICCD (Intensified CCD) camera. The mixing area and uniformity were also analyzed. It is observed that the flow fluctuation in spanwise direction is induced by temperature difference, which enhances mixing process in microchannels.

  • PDF

Application of Holographic Interferometry and 2-D PIV for HSC Convective Flow Diagnostics (Hele-Shaw Cell 내부의 열유동 해석을 위한 홀로그래픽 간섭계와 2차원 PIV의 적용)

  • Kim, Seok;Lee, Sang-Joon
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.682-687
    • /
    • 2003
  • The variations of temperature and velocity fields in a Hele-Shaw convection cell (HSC) were investigated using a holographic interferometry and 2-D PIV system with varying Rayleigh number. To measure quasisteady changes of temperature field, two different measurement methods of holographic interferometry; double-exposure method and real-time method, were employed. In the double-exposure method, unwanted waves can be eliminated effectively using digital image processing technique and the reconstruction images are clear, but transient flow structure cannot be reconstructed clearly. On the other hand, transient convective flow can be reconstructed well using the real-time method. However, the fringe patterns reconstructed by the real-time method contain more noises, compared with the double-exposure method. Experimental results show a steady flow pattern at low Rayleigh numbers and a time-dependent periodic flow structure at high Rayleigh numbers. The periodic flow pattern at high Rayleigh numbers obtained by the real-time holographic interferometer method is in a good agreement with the PIV results.

  • PDF

Micro-PIV Measurements of interfacial electrokinetic effects in a microchannel (마이크로 PTV 기법을 이용한 미세채널 내부 계면의 electrokinetic 효과 해석)

  • Kim Guk-bae;Lee Sang-Joon
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2002.11a
    • /
    • pp.49-50
    • /
    • 2002
  • In micro-channels, the electro-viscous effect is caused by the electrical double layer on pressure-driven liquid flow. Velocity fields of flow inside micro-channels were measured using micro-PIV system for investigating the electro-viscous effect. De-ionized water and aqueous NaCl solutions with four different concentrations were used as working fluid in a PDMS micro-channel of $100{\mu}m$ width and $66{\mu}m$ height. The pressure gradient, dP/dx, was determined from the pre-determined input flow rate Q of syringe pump. The mean velocity $u_m$ used for calculating Reynolds number was obtained from the PIV velocity field data. These are used to plot the pressure gradient as a function of Reynolds numbers. The pressure gradient far lower concentration solution $(10^{-5}\;M)$ was higher than that for the higher concentration solution. The increase of flow resistance was about $30\%\;and\;37.5\%$ at Re=0.02 and 0.06, respectively.

  • PDF

Analysis of Electro-osmotic Flow in a Micro Channel Using a Micro PIV (마이크로 PIV 기법을 이용한 미세채널 내부 electro-osmotic 유동 해석)

  • Kim Yang-Min;Lee Sang-Joon
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2002.11a
    • /
    • pp.51-52
    • /
    • 2002
  • Electro-osmotic flow in a PDMS microchannel of $66{\mu}m\;\times\;200{\mu}m\;\times\;3cm$ has been investigated using a micro PIV system. The field of view was $1056{\mu}m\;\times\;200{\mu}m$ and instantaneous velocity fields were obtained using two-frame cross-correlation method with $64\;\times\;64\;pixels^2$ interrogation window. In this study, we focused on the effect of applied electric field on the variation of internal flow with varying the electric field and seeding particles. The electro-osmotic flow shows a flat velocity profile and the mean velocity is proportional to the applied electric field.

  • PDF

Experimental Investigation on the Drag Reduction Mechanism of Outer-layer Vertical Blades Array using Stereoscopic Time-Resolved PIV (스테레오 시간분해 입자영상유속계를 이용한 외부경계층 수직날 배열에 의한 마찰저항 저감 기구에 관한 실험적 조사)

  • Lee, Inwon;Park, Seong-Hyeon;Chun, Ho-Hwan;Hwang, Arom;An, Nam-Hyun
    • Journal of Power System Engineering
    • /
    • v.17 no.6
    • /
    • pp.95-101
    • /
    • 2013
  • A stereo PIV measurements in a circulating water channel has been performed to investigate the skin friction reduction mechanism of the outer-layer vertical blades first devised by Hutchins. In a recent PIV measurement study, considerable skin friction reduction was achieved as much as 2.73%~7.95% by outer-layer vertical blades array. In the present study, the influence of vertical blades array upon the characteristics of the turbulent coherent structures was analyzed by proper orthogonal decomposition method. It is observed that the vortical structures are cut and deformed by blades array and also the turbulent intensity and the Reynolds stress were weakened by the blades. These phenomena strongly associate the skin-friction drag reduction mechanism in the turbulent boundary layer flow.

Flow Analyses in the Bifurcated Duct with PIV System and Computer Simulation (입자영상유속계와 컴퓨터 시뮬레이션을 이용한 분기관내 유동해석)

  • Sub, Sang-Ho;Choi, Yul;Roh, Hyung-Woon;Doh, Deog-Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.1
    • /
    • pp.123-130
    • /
    • 1999
  • The objective of the current study is to understand steady 3-dimensional flow phenomena in a bifurcated duct experimentally. A bifurcation model is fabricated with transparent acrylic resin to visualize the whole flow field with the PIV system. The gray level cross-correlation method is applied to the image processing algorithm. The subpixel and the area interpolation methods are used to obtain the final velocity vectors. The finite volume predictions are used to analyze the flow patterns in the bifurcation model. The results of the computer simulation and the PIV experiment for three-dimensional flow show the recirculation zone and the formation of the paired secondary flow distal to the apex of the bifurcation model. The results obtained with the two methods also show that the branch flow strongly strikes the inner wall due to the inertial effect and accompanied helical motion as it flows toward the outer wall.

A Study on Flow Characteristics of Polluted Air in Rectangular Tunnel Models Using a PIV System

  • Koh, Young-Ha;Park, Sang-Kyoo;Yang, Hei-Cheon;Lee, Yong-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.6
    • /
    • pp.825-832
    • /
    • 2010
  • The objective of this study is to investigate flow behaviors of polluted air in order to prevent the impact of disaster in a tunnel. This paper presents the experimental results qualitatively in terms of flow characteristics in two kinds of rectangular tunnel models in which each distance from the centerline above the inlet vent to the exhaust vent is 0 and 60 mm, respectively. The olive oil is used as the tracer particles. The flow is tested at the flow rate of $14.16{\times}10^{-4}\;m^3/s$ and the inlet vent velocity of 1.1 m/s with the kinematic viscosity of air. The aspect ratio of the model test section is 10. The average velocity vectors, streamlines, and vorticity distributions are measured and analyzed by the Flow Manager in a particle image velocimetry(PIV) system. The PIV technology gives three different velocity distributions according to observational points of view for understanding the polluted air flow characteristics. The maximum value of mean velocity generally occurs in the inlet and outlet vent regions in the tunnel models.

Development of Algorithm for Stereoscopic PIV using Normalized Cross-correlation (정규상호상관도를 이용한 입체 입자영상유속계 알고리즘 개발)

  • Oh, Jung-Keun;Kim, Yoo-Chul;Ryu, Min-Cheol;Koh, Won-Kyou;Suh, Jung-Chun
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.44 no.6
    • /
    • pp.579-589
    • /
    • 2007
  • Contrary to the conventional single-point measuring devices such as LDV, pitot-tube, hot-wire, etc., it would be possible to measure instantaneously 3-D flow fields with a stereoscopic PIV system. In this paper, we present an analysis algorithm for a stereoscopic PIV system using the normalized cross-correlation (NCC) and a 3-D calibration based reconstruction method. The evaluation method based on NCC is one of the most accurate correlation-based methods. We validated the developed algorithm through a benchmarking comparison with 3-D artificial SPIV images and calibration target images.