• Title/Summary/Keyword: PET Scan

Search Result 254, Processing Time 0.029 seconds

Evaluation of MR Based Respiratory Motion Correction Technique in Liver PET/MRI Study (Liver PET/MRI 검사 시 MR 기반 호흡 움직임 보정 방법의 유용성 평가)

  • Do, Yong Ho;Lee, Hong Jae;Kim, Jin Eui;Noh, Gyeong Woon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.15-22
    • /
    • 2018
  • Purpose Respiratory motion during PET/MRI acquisition may result in image blurring and error in measurement for volume and quantification of lesion. The aim of this study was to evaluate changes of quantitative accuracy, tumor size and image quality by applying MR based respiratory motion correction technique (MBRMCT) using integrated PET/MR scanner. Materials and Methods Data of 30 patients (aged $62.5{\pm}10.2y$) underwent $^{18}F-FDG$ liver PET/MR (Biograph mMR 3.0T, Siemens) study were collected. PET listmode data for 7 minutes was simultaneously acquired with maximum average gate (MAG), minimum time gate (MTG) and non gate (NG) T1 weighted MR images. Gated PET reconstruction was performed using mu-maps generated from MAG and MTG by setting 35% of efficiency window. Maximum SUV ($SUV_{max}$), peak SUV ($SUV_{peak}$), tumor size and full width at half maximum (FWHM) in the z-axis direction of MAG, MTG and NG PET images were evaluated. Results Compared to NG, mean $SUV_{max}$ and $SUV_{peak}$ were increased in MAG 13.15%(p<0.0001), 8.66%(p<0.0001), MTG 13.27%(p<0.0001), 8.80%(p<0.0001) and mean tumor size and FWHM were decreased in MAG 14.47%(p<0.0001), 15.49%(p=0.0004), MTG 14.89%(p<0.0001), 15.79%(p=0.0003) respectively. Mean $SUV_{max}$ and $SUV_{peak}$ of MTG were increased by 0.07%(p=0.8802), 0.13%(p=0.7766). Mean tumor size and FWHM of MTG were decreased by 0.49%(p=0.2786), 0.36%(p=0.2488) compared to MAG. There was no statistically significant difference between MAG and MTG which increase total scan time for about 7 and 2 minutes. Conclusion SUV, accuracy of tumor size and spatial resolution were improved in both of MAG and MTG by applying MBRMCT without installing additional hardware in liver PET/MR study. More accurate information can be provided with the increase of 2 minutes scan time if applying MTG of MBRMCT to various abdominal PET/MR studies affected by respiratory motion.

Role of $^{18}F$-fluorodeoxyglucose PET/CT in Recurrent Ovary Cancer (재발 난소암의 진단에서의 $^{18}F$-fluorodeoxyglucose PET/CT의 유용성: Enhanced CT와 Tumor Marker CA 125와의 비교)

  • O, Joo-Hyun;Yoo, Ie-Ryung;Choi, Woo-Hee;Lee, Won-Hyoung;Kim, Sung-Hoon;Chung, Soo-Kyo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.3
    • /
    • pp.209-217
    • /
    • 2008
  • Purpose: To date, anatomical imaging modalities of the pelvis and tumor markers have been the mainstay of surveillance for recurrent ovary cancer. This study aimed to assess the role of $^{18}F$-FDG PET/CT in evaluation of ovary cancer recurrences, especially in comparison with enhanced a and tumor marker CA 125. Materials and methods: 73 patients who had PET/CT scan for restaging of confirmed ovary cancer, and additional imaging with enhanced a of the pelvis within one month were included. CA 125 level was available in all patients. From the PET/CT images, maximum standard uptake values (SUVmax) of suspected recurrence sites were recorded. Confirmation was available through re-operation or biopsy in 26 cases, and clinical assessment with series of follow-up images in 47. Results: PET/CT had 93% sensitivity and 88% specificity for detecting recurrent ovary cancer. Enhanced a of pelvis had sensitivity and specificity of 83% and 88%, and CA 125 50% and 95%. Conclusion: PET/CT has higher sensitivity for detecting recurrent ovary cancer compared to enhanced a though the differences were not significant. PET/CT has significantly higher sensitivity than CA 125. However, the three tests all agreed in only 43% of the recurrence cases, and recurrence should be suspected when any of the tests, especially PET/CT, show positive findings.

The Effect of PET Scan Time on the Off-Line PET Image Quality in Proton Therapy (양성자 치료에서 영상 획득 시간에 따른 Off Line PET의 효율성 검증)

  • Hong, Gun-Chul;Jang, Joon-Yung;Park, Se-Joon;Cha, Eun-Sun;Lee, Hyuk
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.2
    • /
    • pp.74-79
    • /
    • 2017
  • Purpose Proton therapy can deliver an optimal dose to tumor while reducing unnecessary dose to normal tissue as compared the conventional photon therapy. As proton beams are irradiated into tissue, various positron emitters are produced via nuclear fragmentation reactions. These positron emitters could be used for the dose verification by using PET. However, the short half-life of the radioisotopes makes it hard to obtain the enough amounts of events. The aim of this study is to investigate the effect of off-line PET imaging scan time on the PET image quality. Materials and Methods The various diameters of spheres (D=37, 28, 22 mm) filled with distilled water were inserted in a 2001 IEC body phantom. Then proton beams (100 MU) were irradiated into the center of the each sphere using the wobbling technique with the gantry angle of $0^{\circ}$. The modulation widths of the spread out bragg peak were 16.4, 14.7 and 9.3 cm for the spheres of 37, 28 and 22 mm in diameters respectively. After 5 min of the proton irradiation, the PET images of the IEC body phantom were obtained for 50 min. The PET images with different time courses (0-10 min, 11-20 min, 21-30 min, 31-40 min and 41-50 min) were obtained by dividing the frame with a duration of 10 min. In order to evaluate the off-line PET image quality with the different time courses, the contrast-to-noise ratio (CNR) of the PET image calculated for each sphere. Results The CNRs of the sphere (D=37 mm) were 0.43, 0.42, 0.40, 0.31 and 0.21 for the time courses of 0-10 min, 11-20 min, 21-30 min, 31-40 min and 41-50 min respectively. The CNRs of the sphere (D=28 mm) were 0.36, 0.32, 0.27, 0.19 and 0.09 for the time courses of 0-10 min, 11-20 min, 21-30 min, 31-40 min and 41-50 min respectively. The CNR of 37 mm sphere was decreased rapidly after 30 min of the proton irradiation. In case of the spheres of 28 mm and 22 mm, the CNR was decreased drastically after 20 min of the irradiation. Conclusion The off-line PET imaging time is an important factor for the monitoring of the proton therapy. In case of the lesion diameter of 22 mm, the off-line PET image should be obtained within 25 min after the proton irradiation. When it comes to small size of tumor, the long PET imaging time will be beneficial for the proton therapy treatment monitoring.

  • PDF

F-18 FDG Uptake in a Toxic Autonomous Thyroid Nodule

  • Lee, Myoung-Hoon;Park, Chan-H.;Kim, Hyun-Soo;Yoon, Seok-Nam;Hwang, Kyung-Hoon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.4
    • /
    • pp.286-287
    • /
    • 2001
  • A 44 year-old male patient was undergoing diagnosis and therapy for acute myelogenous leukemia (AML, M2). On physical examination a thyroid mass was palpated in the left lower lobe. He had palpitation and intolerance to heat. Thyroid function tests revealed hyperthyroidism; T3: 150ng/dl (N:60-90), fT4: 2.26 ng/dl (N:0.70-1.80), TSH: 0.01 ulU/ml (N:0.25-5.00). Ultrasonography demonstrated a hypoechoic mass with scattered calcifications measuring 2.55 2.03 3.64 cm in size. F-18 FDG camera-based PET scan performed as a follow-up study of AML revealed a focal increased uptake in the left neck, where an autonomous nodule was detected on Tc-99m thyroid scan. After the diagnosis of toxic autonomous nodule, Goetz disease, he underwent surgical nodulectomy. Microscopically, the nodule contained follicular proliferation with degenerative change but without evidence of thyroid carcinoma. Focal uptake in autonomous thyroid nodules is due to increased glycolysis within the nodules.

  • PDF

Incidental Extramammary Findings on Preoperative Breast MRI in Breast Cancer Patients: A Pictorial Essay (유방암 환자의 수술 전 유방 MRI에서 우연히 발견된 유방 외 소견: 임상화보)

  • Jin-A Ryoo;Shin Young Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.2
    • /
    • pp.372-385
    • /
    • 2023
  • Breast cancer is one of the most common cancers and causes several complications in females. Currently, MRI is a necessary method for preoperative studies in patients with breast cancer. A high frequency of breast MRI can lead to an increase in the number of incidental extramammary findings. Moreover, it can provide accurate preoperative workup; therefore, the prognosis of patients can be improved. Herein, we provide several extramammary findings, including the mediastinum, lung, upper abdomen, bone, and soft tissue, correlating with US, chest CT, liver MRI, PET-CT, and bone scan.

A study on image registration and fusion of MRI and SPECT/PET (뇌의 단일 광자 방출 전산화 단층촬영 영상, 양전자 방출 단층 촬영 영상 그리고 핵자기공명 영상의 융합과 등록에 관한 연구)

  • Joo, Ra-Hyung;Choi, Yong;Kwon, Soo-Il;Heo, Soo-Jin
    • Progress in Medical Physics
    • /
    • v.9 no.1
    • /
    • pp.47-53
    • /
    • 1998
  • Nuclear Medicine Images have comparatively poor spatial resolution, making it difficult to relate the functional information which they contain to precise anatomical structures. Anatomical structures useful in the interpretation of SPECT /PET Images were radiolabelled. PET/SPECT Images Provide functional information, whereas MRI mainly demonstrate morphology and anatomical. Fusion or Image Registration improves the information obtained by correlating images from various modalities. Brain Scan were studied on one or more occations using MRI and SPECT. The data were aligned using a point pair methods and surface matching. SPECT and MR Images was tested using a three dimensional water fillable Hoffman Brain Phantom with small marker and PET and MR Image was tested using a patient data. Registration of SPECT and MR Images is feasible and allows more accurate anatomic assessment of sites of abnormal uptake in radiolabeled studies. Point based registration was accurate and easily implemented three dimensional registration of multimodality data set for fusion of clinical anatomic and functional imaging modalities. Accuracy of a surface matching algorithm and homologous feature pair matching for three dimensional image registration of Single Photon Emission Computed Tomography Emission Computed Tomography (SPECT), Positron Emission Tomography (PET) and Magnetic Resonance Images(MRD was tested using a three dimensional water fill able brain phantom and Patients data. Transformation parameter for translation and scaling were determined by homologous feature point pair to match each SPECT and PET scan with MR images.

  • PDF

Granuloma Resulting from the Cervical Metallic Plate, Masquerading as Posterior Pharyngeal Wall Cancer (하인두 후벽암으로 오인된 경추 내고정 금속판 삽입 후 발생한 육아종 1예)

  • Kim, Seung-Woo;Kim, Young-Bae;Sah, Dae-Jin
    • Korean Journal of Head & Neck Oncology
    • /
    • v.27 no.2
    • /
    • pp.218-221
    • /
    • 2011
  • The anterior approach to the cervical spine surgery is associated with possible complications such as dysphagia, hoarseness and granuloma formation etc. Because of orthopedic metallic plates, the increasing or focal uptake pattern may be demonstrated in $^{18}F$-FDG PET/CT scan. A 67-year-old-man came to our department, complained of dysphagia during the 4 months. He underwent cervical spine surgery three years ago. The CT and MRI findings mimicked typical posterior pharyngeal wall cancer with cervical metastasis. Furthermore, the SUV in $^{18}F$-FDG PET/CT was 10.3. But he was finally diagnosed as a granuloma resulting from the metallic cervical implants. The clinical correlation and medical history should be taken into account to avoid false-positive findings in PET/CT and to avoid many erroneous diagnostic pathways.

PET/CT Manifestation of the Meniscus Sign of Ulcerating Gastric Carcinoma (궤양성 위 암종에 나타난 초승달 징후의 펫/시티 소견)

  • Bahk, Yong-Whee
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.4
    • /
    • pp.335-336
    • /
    • 2007
  • Meniscus-like presentation of ulcerating gastric carcinoma on upper gastrointestinal series radiograph was first described in 1921 by Carman and has since been known as a useful differential diagnostic sign in radiology. In 1982 using then newly introduced computed tomography (CT) Widder and Mueller revisited the meniscus sign. Their study was primarily focused on a dynamic assessment of the demonstrability of the meniscus sign that largely depends on the judgment and technical skill of examiner, especially graded compression and patient positioning. One year earlier Balfe et al. assessed the diagnostic reliability of gastric wall thickening as observed on CT scan in adenocarcinoma, lymphoma and leiomyosarcoma and concluded that it is not a reliable finding. In contrast, however, Lee et al. recently emphasized that the wall thickness measurement on CT of exophytic carcinoma, myoma and ulcers was a useful diagnostic means. Thus, it appears that gastric wall thickening or mucosal heave-up is by itself not as reliable as the meniscus sign. The electronic search of world literature failed to disclose earlier report of this sign demonstrated by $^{18}F-FDG$ positron emission tomography and computed tomography (PET/CT). The present communication documents $^{18}F-FDG$ PET/CT finding of the meniscus sign as encountered in a case of ulcerating gastric carcinoma, the histological diagnosis of which was moderately differentiated tubular adenocarcinoma. Unlike most gastric tumors without ulceration that tend to unimpressively accumulate $^{18}F-FDG$ the present case of Borrmann type III gastric carcinoma demonstrated markedly increased $^{18}F-FDG$ uptake.

Pet Disease Prediction Service and Integrated Management Application (반려동물 질병예측서비스 및 통합관리 어플리케이션)

  • Ki-Du Pyo;Dong-Young Lee;Won-Se Jung;Oh-Jun Kwon;Kyung-Suk Han
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.23 no.6
    • /
    • pp.133-137
    • /
    • 2023
  • In this paper, we developed a 'comprehensive pet management application' that combines pet AI diagnosis, animal hospital search, smart household accounts, and community functions. The application can solve the inconvenience of users who have to use multiple functions as separate applications, and can easily use pet AI diagnosis services through photos, provides animal hospital information using crawling, finds nearby animal hospitals, and supports smart households that can scan receipts using OCR text extraction techniques. By using this application, information necessary for raising pets such as health and consumption details of pets can be managed in one system.

The Lowest Dose for CT Attenuation Correction in PET/CT

  • Kang, Byung-Sam;Son, Jin-Hyun;Park, Hoon-Hee;Dong, Kyung-Rae
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.3
    • /
    • pp.111-115
    • /
    • 2011
  • PET/CT(Positron Emission Tomography/Computed Tomography) is an examination combining morphological and functional information in one examination. The purpose of this study is to see the lowest CT dose for attenuation correction in the PET/CT maintaining good image quality when considering CT scan dose to the patients. We injected $^{18}F$-FDG and water into the cylinder shaped phantom, and obtained emission images for 3 mins and transmission images(140 kVp, 8 sec, 10~200 mA for transmission images), and reconstructed the images to PET/CT images with Iterative method. Data(Maximum, Minimum, Average, Standard Deviation) were obtained by drawing a circular ROI(Region Of Interest) on each sphere in each image set with Image J program. And then described SD according to the CT and PEC/CT images as graphes. Through the graphes, we got the relationships of mA and quality of images. SDs according to CT graph were 16.25 at 10 mA, 7.26 at 50 mA, 5.5 at 100 mA, 4.29 at 150 mA, and 3.83 at 200 mA, i.e. the higer mA, the better image quality was presented. SDs according to PET/CT graph were 1823.2 at 10 mA, 1825.1 at 50 mA, 1828.4 at 100 mA, 1813.8 at 150 mA, and 1811.3 at 200 mA. Calculated SDs at PET/CT images were maintained. This means images quality is maintained having nothing to do with mA of high and low.

  • PDF