• Title/Summary/Keyword: PERFORMANCE MEASUREMENT

Search Result 7,004, Processing Time 0.029 seconds

Pavement Performance Model Development Using Bayesian Algorithm (베이지안 기법을 활용한 공용성 모델개발 연구)

  • Mun, Sungho
    • International Journal of Highway Engineering
    • /
    • v.18 no.1
    • /
    • pp.91-97
    • /
    • 2016
  • PURPOSES : The objective of this paper is to develop a pavement performance model based on the Bayesian algorithm, and compare the measured and predicted performance data. METHODS : In this paper, several pavement types such as SMA (stone mastic asphalt), PSMA (polymer-modified stone mastic asphalt), PMA (polymer-modified asphalt), SBS (styrene-butadiene-styrene) modified asphalt, and DGA (dense-graded asphalt) are modeled in terms of the performance evaluation of pavement structures, using the Bayesian algorithm. RESULTS : From case studies related to the performance model development, the statistical parameters of the mean value and standard deviation can be obtained through the Bayesian algorithm, using the initial performance data of two different pavement cases. Furthermore, an accurate performance model can be developed, based on the comparison between the measured and predicted performance data. CONCLUSIONS : Based on the results of the case studies, it is concluded that the determined coefficients of the nonlinear performance models can be used to accurately predict the long-term performance behaviors of DGA and modified asphalt concrete pavements. In addition, the developed models were evaluated through comparison studies between the initial measurement and prediction data, as well as between the final measurement and prediction data. In the model development, the initial measured data were used.

Application of the Balanced Scorecard for the Performance Measurement in Health-care Organization (의료기관에서의 Balanced Scorecard를 이용한 성과측정)

  • Chun, Je-Ran
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.4
    • /
    • pp.254-264
    • /
    • 2009
  • The purpose of this study was to develop a performance measurement factor of Balanced Scorecard(BSC) for health-care organization. We did also the research to evaluate the validity and reliability of these indicators. Fifty six health-care organizations are participated in a survey questionnaires. This questionnaires consists of 53-questions, which are the performance evaluation indicators designed by researcher, which are based on the Norton and Kaplan's BSC-Framework. Exploratory and confirmatory factor analysis was carried out and Analytical Hierarchy Process (AHP) was applied to analyze the weight and significances of each factor. Factor analysis of the BSC resulted in 11 major measurement factors (Eigenvalue >1.0). The AHP analysis showed the list of the hospital BSC measurement factors and its KPI(Key Performance Indicator) weighted by its significance priorities. The recommendable degree of reliability and validity of these BSC factors suggests that these factors are adequate for performance measurements of the health-care organizations in Korea.

Development of Performance Measures Based on Nursing Process for Oxygen Therapy and Airway Suctioning (간호과정 적용 평가도구 개발 -산소요법과 흡인간호를 중심으로-)

  • Kim, Keum Soon;Choi, Yun Kyoung;Lee, Jung Lim;Ahn, Jung Won;Lee, So Lim;Choi, Won Ja;Kim, Eul Soon
    • Journal of Korean Clinical Nursing Research
    • /
    • v.19 no.1
    • /
    • pp.1-19
    • /
    • 2013
  • Purpose: This study was conducted to develop standards to ensure nursing process-based care of oxygen therapy and airway suctioning and to develop a performance measurement tool to evaluate the care applied according to the standards, and finally to determine validity of the standards and the tool. Methods: The standards and the tool were reviewed by a panel of experts and refined based on the panel's suggestions. Validity of the standards and the tool were examined through surveying a total of 366 hospital nurses. Results: The mean validity scores of the performance measurement standards and the tool were 3.58 and 3.55, respectively, out of 4.00. So the performance measurement standards and the tool in this study were found to be acceptable in evaluating quality of nursing care provided at patient admission and discharge. Conclusion: This result indicates that the performance measurement standards and the tool developed in this study are valid instruments to monitor and improve quality of nursing care for oxygen therapy and airway suctioning.

Steady-State Performance Simulation and Engine Condition Monitoring for 2-Spool Separate Flow Type Turbofan Engine (2-스풀 분리배기 방식 터보팬 엔진의 성능모사 및 진단에 관한 연구)

  • Gong, Chang Deok;Gang, Myeong Cheol
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.31 no.4
    • /
    • pp.60-68
    • /
    • 2003
  • In this study, a steady state performance analysis program was developed for a turbofan engine, and its performance was analyzed at installed conditions. For the purpose of evaluation, the developed program was compared with the performance data provided by the engine manufacturer. It was confirmed that the developed program was reliable because the results by the developed program were well agreed with those by the engine manufacturer within 3.5%. The non-linear GPA(Gas Path Analysis) program for performance diagnostics were developed, and selection of optimal measurement variables was studied. Furthermore, in order to investigate effects of the number and the kind of measurement variables, the non-linear GPA was analyzed with various measurement sets. Finally, the measurement parameters selected in the previous step were applied to the fault detection analysis of the 2-spool separate flow type turbofan engine.

A General ion Method of Measurement Units for Performance Tracking (진도율 산정을 위한 측정 단위 도출 방안에 관한 연구)

  • Yoon Su-Won;Chin Sang-Yoon;Kim Yea-Sang;Jung Young-Soo;Park Sung-Soo;Park Soon-Chan
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • autumn
    • /
    • pp.521-524
    • /
    • 2003
  • Recently various construction management systems are applied for more efficient project management, and through them as-built construction information is collected. However, the accuracy of the collected information shows big differences among projects, since tile collection of tile as-built information is not based on objective manner or criteria and also each management personnel uses difference criteria on this based on individual experiences. This initiates the need for a development of methods and information frameworks for efficient collection and management of as-built information with assurance of data accuracy. Therefor the objective of this study is to suggest a method to determine the task performance measurement unit depending on the characteristics of work types. A prototype system was developed for generating task performance measurement units by utilizing MS ACCESS. The information framework and the system developed in this research is expected to help standardized performance measurements across projects by improving the objectivity and the accuracy of the collected information.

  • PDF

Development of Performance Measures Based on Nursing Process for Fluid Intake/Output and Tube Care (간호과정 적용 평가도구 개발 -수분섭취/배설간호와 튜브간호를 중심으로-)

  • Kim, Keum Soon;Choi, Yun Kyoung;Choi, Wan Hee;Ahn, Jung Won;Kim, Jin A;Park, Seung Mi;Choi, Kyung Ok;Kim, Eul Soon
    • Journal of Korean Clinical Nursing Research
    • /
    • v.18 no.1
    • /
    • pp.13-28
    • /
    • 2012
  • Purpose: This study was conducted to develop standards ensuring nursing process-based fluid intake/output and tube care, and to develop a performance measurement tool evaluating the level of care according to the standards, and finally to determine validity of the standards and the tool. Methods: The standards and the tool were reviewed by a panel of experts and refined based on the panel's suggestions. Validity of the standards and the tool were examined using a survey of 293 hospital nurses. Results: The mean validity scores of the performance measurement standards and the tool were 3.86 and 4.02, respectively, out of 5.00. So the performance measurement standards and the tool in this study were found to be acceptable in evaluating quality of nursing care for fluid intake/output and tubes. Conclusion: This result indicates that the performance measurement standards and the tool developed in this study are valid instruments to monitor and improve quality of nursing care for fluid intake/output and tube interventions, such as intravenous catheters, nasogastric tube and urinary catheters.

Automated Analysis of fetal Myocardial Performance Index of Doppler Waveform in Normal Pregnancy (정상 태아의 임신 분기별 좌심실 도플러 신호 자동 분석)

  • Kim, Su-min;Ye, Soo-young
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.6
    • /
    • pp.791-800
    • /
    • 2020
  • Ultrasonography is widely used to evaluate the function of fetal heart, but due to the subjective nature of the test, there are differences in measurement methods for each examiner, and especially the myocardial performance index has no reference index to date. Therefore, in this study, we wanted to analyze pulse Doppler waveforms of normal fetuses and develop an automatic measurement program to make objective measurements. One hundred and thirty-three pregnant women who visited the hospital for prenatal examinations were studied, myocardial performance index was measured after acquiring a pulse doppler image of the left ventricle. As a result, the early, mid and late pregnancy myocardial performance index, measured by the automatic measurement program conducted in this study, was found to increase as pregnancy continued.

A Study on Developing of Performance Evaluation Index and Method of Measurement for Information Security Outcomes applying BSC (균형성과표(BSC) 기반의 정보보호 성과 지표 개발 및 측정 방법에 관한 연구)

  • Jang, Sang Soo
    • Convergence Security Journal
    • /
    • v.14 no.4
    • /
    • pp.41-53
    • /
    • 2014
  • In order to achieve efficient and effective organizational information security objectives, for the level of information security to accurately evaluation and direction for improving that performance evaluation index and method of measurement for information security outcomes are needed. For information security activities of domestic companies to measure the performance or effectiveness, that standard method of measuring and the available evaluation Index are insufficient. company is difficult to investment for information security budget. Therefore, the purpose of this study was developing of performance evaluation index and method of measurement for information security outcomes applying BSC available in the company. The results of this study that companies can determine the level of information security itself. Analysis of the information security status and the strategy establishment of the information security investment can be applied.

The Case Study on Performance Measurement Weighting for Efficient Value Engineering Study of Sewage Treatment Facliity (하수처리시설의 효율적인 VE수행을 위한 다단계성능평가 분석)

  • Kim, Dongjin;Park, Jaeil;Lee, Jaehun;Lee, Minjae
    • Korean Journal of Construction Engineering and Management
    • /
    • v.17 no.1
    • /
    • pp.40-47
    • /
    • 2016
  • Recently, the demand of sewage treatment facilities have increased by growing the population growth of city and industrialization. However, most of public sewage treatment facilities lack the preparations of design criteria by increasing sewage water amount in the future. In order to respond to this situation, the government has consistently promoted the sewage treatment construction project. This study conducted a survey targeting residents and sewage treatment facilities, civil engineering a VE project professionals for effectively operating the sewage treatment facilities and improving its value to be built in the future. Based on this survey, this study will introduce the list of performance measurements which can not only save cost but also reflect opinion of users and residents. In addition, using Multi-Level Performance Measurement and AHP analyzed the weights of performance measurement which is more objective than existing things for applying efficient VE process

Performance evaluation method of homogeneous stereo camera system for full-field structural deformation estimation

  • Yun, Jong-Min;Kim, Ho-Young;Han, Jae-Hung;Kim, Hong-Il;Kwon, Hyuk-Jun
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.16 no.3
    • /
    • pp.380-393
    • /
    • 2015
  • This study presents how we can evaluate stereo camera systems for the structural deformation monitoring. A stereo camera system, consisting of a set of stereo cameras and reflective markers attached on the structure, is introduced for the measurement and the stereo pattern recognition (SPR) method is utilized for the full-field structural deformation estimation. Performance of this measurement system depends on many parameters including types and specifications of the cameras, locations and orientations of them, and sizes and positions of markers; it is difficult to experimentally identify the effects of each parameter on the measurement performance. In this study, a simulation framework for evaluating performance of the stereo camera systems with various parameters has been developed. The maximum normalized root-mean-square (RMS) error is defined as a representative index of stereo camera system performance. A plate structure is chosen for an introductory example. Its several modal harmonic vibrations are generated and estimated in the simulation framework. Two cases of simulations are conducted to see the effects of camera locations and the resolutions of the cameras. An experimental validation is carried out for a few selected cases from the simulations. Using the simultaneous laser displacement sensor (LDS) measurements as the reference, the measurement errors are obtained and compared with the simulations.