• Title/Summary/Keyword: PE condition

Search Result 173, Processing Time 0.02 seconds

Study on Hospital Environmental Causes Affected the Mother′s Comfort After Her Child Birth (산욕부 안위에 영향을 미치는 병원환경 요인에 관한 연구)

  • 변수자
    • Journal of Korean Academy of Nursing
    • /
    • v.8 no.1
    • /
    • pp.1-15
    • /
    • 1978
  • The Purpose of this study is to examine closely the causes influenced upon the comfort and recovery of the woman delivered of a child in the hospital at the same time to understand environmental status of hospitals in order to promote mother's health recovery, and to improve hospital environment by emphasizing the meaning of environment and health before the medical staff and hospital administrative authority. In the method of servery of the research, 165 post paestum patients have been randomly selected who were accommodated and delivered their babies at OB(obstetric ) & GY (Gynecologic) unit the 7 general hospitals for the period of 6 December 1976 through 17 December 1976. As for the survey, it has been used of Questionnaire where we have 65 items in the respect of personal environment in the hospital such as trusting nurse, ability, reliability, kindness and etiquette of nurse and tile character of nurse the relationship with patients the other respect of physical environment included 9f temperature, moisture. air-ventilation lightening noise, cleanness. facilities, and the third realm being of mother's hearth ground to have the following conclusion 1. The feature of the collected personnel they are from OB or GY sects of from OB unit of the other 5 hospitals except the two general hospitals of the college or school Otherwise the rate of the patients to nurses would be 9 : 1. As for the nurses'ground it would be appeared of 20-25 years of age as the 76%. either 3 year course or 4 year course in the education would be each 50% and less than 2 year experience case would record as of 60 %. In the respect of hospital physical environmental status, there we have two hospitals without any thermometers, on the other han4 nowhere there's hygrometer, otherwise, the lightening is normal or over than normal As for the structure of noise protection the corridors're, generally speaking worse than rooms, nerver hueless, there's no ventilating system in the hospitals. The rooms'repainted in white and yellow, light green white, or green color. The patient's clothing were in green pink blue, light green or in white co for. There're not anything special in both decoration and equipments. Most of them used tall beds except in one hospital 2. To the extent of perception of patient's hatch 9round and hospital environment it is presented that they perceived nurse's ability in highest in total human variable, though perceived kindness or etiquette in the lowest otherwise, comparatively high in total average. 3. In the respect of physical environment it is highest perceived of lightening terms, otherwise, lowest perceived of air ventilation and total average became lowest than the one of the original record 4. To ages, in the respect of hatch ground rather old aged mother than the younger one has perceived that nurse would be trusting, in good service character, able, at the same time, liable, Otherwise, in physical environment regardless of age, they perceived lightening in high and remarkably lower in ventilation As a result of the examination of the difference in hospital environment to each age it is appeared of statistical difference at 5% level of ability in the personal environment otherwise little difference as for physical environment 5. In the respect of perceiving level to educational standard it is highly perceived of personal environment for higher ranking group rather than lower group in the educational standard. In case of physical environment it is highly perceived for lower level group rather than higher level group in educational background. The variables which have statistical significance at 5% level are from trusting kindness, etiquette and total kindness, etiquette and total all significance at 5% level are from trusting, kindness, etiquette and total human environment variable in personal environment, otherwise, there's little difference in the physical environment. 6. The perceiving level due to times of admission and accommodation at the hospital would be cleared out as gradual higher perception both physical and personal environment in the hospital. At 5% significant level of the ventilation condition in physical environmental variable it is presented of meaningful difference otherwise, there we have little difference both in Personal variable and other one. 7. In accordance with living standard, the perception degree of personal environment in tee hospital would be inclined to increase to higher living standard on the other hand, in case of the physical environment, the perception level world increase to lower living standard At 5 % level, the trustuariable and total scores in the personal eicuironmectal variable there appeared a meaningful/ significant difference otherwise, there presented little difference both in physical environmental and other variable to the living standard 8. Pertaining to family unit, the mother of an independent family unit perceived highly in all respect of the personal and the physical environment in the hospital rather than the woman of succeeding family unit. At 5 % level there appeared a difference in the respect of kindness and etiquette both in personal environment variable, on the other hand, there hardly marked a difference between other variable and physical environmental one. 9. The degree of perception to comforting level has little connection with a statistical difference the age, educational level hospital admitting times, living standard or family unit. 10. The most effective variable to mother's comforting level will be nurse's ability, reliability, trusting manner, and total physical environment variable in order.

  • PDF

Current Research Trend of Postharvest Technology for Chrysanthemum (국화 수확 후 관리기술의 최근 연구 동향)

  • Kim, Su-Jeong;Lee, Seung-Koo;Kim, Ki-Sun
    • Korean Journal of Plant Resources
    • /
    • v.25 no.1
    • /
    • pp.156-168
    • /
    • 2012
  • Chrysanthemum is a cut flower species that normally lasts for 1 to 2 weeks, in some cases 3-4 weeks. This has been attributed to low ethylene production during senescence. Reduction in cut flower quality has been attributed to the formation of air embolisms that partially or completely blocks the water transport from the vase solution to the rest of the cut flower stem, increasing hydraulic resistance which may cause severe water stress, yellowing, wilting of leaf, and chlorophyll degradation. Standard type chrysanthemum can be harvested when buds were still tightly closed and then fully opened with the simple bud-opening solution. Standard type chrysanthemum can also be harvested when the minimum size of the inflorescence is about 5-6 cm bud which opened into the first flower full-sized flower. While spray varieties can be harvested when 2-4 most mature flowers have opened (40% opening). Cut flowers are sorted by stem length, weight, condition, and so on. Standard chrysanthemum is 80 cm length for standard type and 70cm for spray type. Pre-treatment with a STS, plant regulator such as GA, BA, 1-MCP, chrysal, germicide, and sucrose, significantly improved the vase life and quality of cut flowers. It is well established that vase solutions containing sugar can improve the vase life of cut chrysanthemum. Chrysanthemum is normally packed in standard horizontal fiberboard boxes. Chrysanthemum should normally be stored at $5{\sim}7^{\circ}C$. Precooling resulted in reduction in respiration, decomposition, and transpiration activities as well as decoloration retardation. There was significant difference between "wet" storage in 3 weeks and "dry" storage in 2 weeks. In separate pulsing solution trials, various germicides were tested, as well as PGRs to maintain the green color of leaves and turgidity. Prolonging vase life was attained with the application of optimal solution such as HQS, $AgNO_3$, GA, BA and sucrose. This also retarded senescence in leaves of cut flower stems. Fresh cut chrysanthemum can be transported using a refrigerated van with $5{\sim}7^{\circ}C$. Increasing consumption and usage of cut chrysanthemum of various cultivars would require efficient transport system, and effective information exchange among producer, wholesaler, and consumer.

Ecological Studies on the Transition of Sheath Blight of Rice in Korea (한국(韓國)에서의 벼 잎집무늬마름병 발생변동(發生變動)에 관(關)한 생태학적(生態學的) 연구(硏究))

  • Yu, Seung-hun
    • Korean Journal of Agricultural Science
    • /
    • v.4 no.2
    • /
    • pp.283-316
    • /
    • 1977
  • In an attempt to obtain a basic information to develop an effective integrated system of controlling sheath blight of rice in Korea, the transition of this disease, the variation of cultural characters and pathogenicity of the pathogen, environmental conditions affecting the disease outbreak and varietal resistance have been investigated. 1. Rice sheath blight which has been minor disease in the past was widely spread, especially since 1971. This disease has promptly spread all over the country and infected 65.2% of total rice growing area in 1976. Various factors are considered to be related to such transition of this disease. Above all, increace of application of nitrogenous fertilizer, early season and earlier cultivation of rice, introduction of more susceptible "Tongil" varieties etc. must be important factors influencing the outbreak of this disease. 2. Great variations in cultural characteristics-such as mycelial growth rate, color of the medium, amount of the aerial mycelium, shape and color of the sclerotia- and in the pathogenicity of isolates of the pathogen, Thanatephorus cucumeris Dank were observed. The optimum temperature for mycelial growth also varied with isolates, from $25^{\circ}C$ to $30^{\circ}C$. There were not necessarily any correlation between curtural characteristics and pathogenicity of isolates of Thanatephorus cucumens. 3. Mycelial grow th of isolates of Thanatephorus cucumens on the PDA medium were correlated with the air temperatures of the region where the isolates were collected. The isolates from the regions with high temperature grew well on PDA medium at $35^{\circ}C$ than those from the region with low temperature, on the other hand, the isolates from the regions with the low temperature grew well on the same medium at $12^{\circ}C$ than those from the regions with high temperature. 4. Pectin polygalacturonase (PG) and cellulase (Cx) were most active on the 3rd day after inoculation on the leaves of rice plant with Thanatephorus cucumeris, whereas pectin methylestrase (PE) was most active on the 4th day after inoculation. Relationship between the activities of PE of isolates and the strength of pathogenicity of isolates was obtained, but PG and cellulase activities were not correlated with pathogenicity of isolates. 5. The tolerence of sclerotia from in-vitro culture to low temperature varied with their water content, the dried cultural sclerotia were more tolerent than wet ones, Dried cultural sclerotia maintained almost 100% germinability for 45 days at $-20^{\circ}C$, whereas wet sclerotia lost viability at $-5^{\circ}C$. The germination ratio of the sclerotia after overwintering changed from 18% to 70% according to the water content of the test paddy fields and the ratio was low in wet paddy condition. 6. To investigate the host range of this fungi in and near paddy field, 17 weeds were inoculated with fungi. The lesions of sheath blight disease was obserbed on Sagittaria trifolia L., Echinochloa crusgalli P. Beauv., Monochoria vaginal is Presl, Polygonum Hydropiper L., Eclipta prostrata L., Digitaria sanguinalis Scapoli. 7. When the level of nitrogen applied was doubled over standard level, total nitrogen content in rice sheath increased, ami when silicate was applied, starch content in rice sheath decreased, inducing the rice plants more susceptible to sheath blight disease. Increased dressing of potash ferilizer reduced the incidence of sheat blight disease. 8. The percentage of infected stems in the early period increased more in the narrow hill plot than in the wide hill plot, but in the late period this tendency was inversed; the percentage of infected stems as well as severity in the wide hill plot increased more compared to the narrow hill plot, and the disease severity in the one plant per hill plot was also low. The number of stems in the wide hill plot was more than the number of stems in the narrow hill plot. This indicates that the microclimate, such as the relative humidity, in the narrow hill plot was more favorable for the development of this disease. 9. There was a high negative correlation between the disease severity of varieties to the sheath blight and the maturity of the varieties, that is, the early varieties were more susceptible than the late ones, and much-tillering varieties usually showed more infection than less tillering varieties. 10. No relationship was obtained between the percentage of infected stems in the early period and the severity after heading, whereas a distinct relationship was obtained between former and latter after Aug. 10.

  • PDF