• Title/Summary/Keyword: PDA.

Search Result 2,667, Processing Time 0.03 seconds

PDA System for Maximizing the Efficiency of Smart Pallet Based Rarts Delivery System (스마트 파렛트 기반 부품공급시스템의 운영 효율성 증대를 위한 PDA 시스템)

  • Lee, Young-Du;Koo, In-Soo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.10 no.4
    • /
    • pp.115-120
    • /
    • 2010
  • Products companies, which manufactures finished goods with modular parts, will expect that the proper parts should be delivered to assembly line not only just in time (JIT) but also just in sequence (JIS) and also expect that faulty goods will not be produced due to the delivery of wrong parts. In order to satisfy the above requirements, recently Smart Pallet based Parts Delivery system (SPPD) was proposed. SPPD system can overcome the drawback of bar code based part delivery system in which much time for checking proper and in sequence parts is wasted due to labors' working in hand as well as the drawback of RFID based part delivery system in which recognition distance of RFID is very limited. In the paper, a PDA system is proposed and further implemented to maximize the efficiency of SPPD's operation as well as to manage the limited power of smart pallets efficiently.

Designing Handheld Learning Tool Based On Cognitive Load Theory (인지 부하 이론에 기초한 PDA 기반 학습 프로그램 설계 연구)

  • Kim, Dongsik;Kwon, Sukjin
    • The Journal of Korean Association of Computer Education
    • /
    • v.10 no.1
    • /
    • pp.67-75
    • /
    • 2007
  • The purpose of the study is to develop handheld learning tool based on design principles drawn from cognitive load theory. To optimize learner's cognitive load, the learning program should be developed for maximizing the effective load and(or) minimizing ineffective load. The principles, which were applied to developing the learning program, for minimizing the extraneous cognitive load, one of the ineffective loads, are modality, redundancy, split-attention, multimedia, and worked-out example. In this study, we will show possibilities for designing an effective mobile learning program.

  • PDF

Drivability Monitoring of Large Diameter Underwater Steel Pipe Pile Using Pile Driving Analyzer. (수중 대구경강관말뚝의 항타관입성 모니터링을 위한 PDA 적용 사례)

  • Kim, Dae-Hak;Park, Min-Chul;Kang, Hyung-Sun;Lee, Won-Je
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2004.03b
    • /
    • pp.11-19
    • /
    • 2004
  • When pile foundation constructed by driving method, it is desirable to perform monitoring and estimation of pile drivability and bearing capacity using some suitable tools. Dynamic Pile Monitoring yields information regarding the hammer, driving system, and pile and soil behaviour that can be used to confirm the assumptions of wave equation analysis. Dynamic Pile Monitoring is performed with the Pile Driving Analyser. The Pile Driving Analyser (PDA) uses wave propagation theory to compute numerous variables that fully describe the condition of the hammer-pile-soil system in real time, following each hammer impact. This approach allows immediate field verification of hammer performance, driving efficiency, and an estimate of pile capacity. The PDA has been used widely as a most effective control method of pile installations. A set of PDA test was performed at the site of Donghea-1 Gas Platform Jacket which is located east of Ulsan. The drilling core sediments of location of jacket subsoil are composed of mud and sand, silt. In this case study, the results of PDA test which was applied to measurement and estimation of large diameter open ended steel pipe pile driven by underwater hydraulic hammer, MHU-800S, at the marine sediments were summarized.

  • PDF

A study on the characterization of stearic acid and PDA LB films and the optimum conditions for the stable films on the water (Stearic acid와 PDA LB막의 특성 분석과 막 형성 조건에 관한 연구)

  • Jeon, Yong-Joo;Kwon, O-Dae;Jeong, Sang-Don;Jeong, Cheol-Hyeong;Kim, Jang-Joo
    • Proceedings of the KIEE Conference
    • /
    • 1989.11a
    • /
    • pp.102-104
    • /
    • 1989
  • The characteristics of stearic acid and PDA (pentacosaDiyonicAcid) LB films were studied using the XRD spectra for regularity of layers and ellipsometer for the total thickness of multilayer films. From the experiments of varying the PH and temperature, it was found that the stability of monolayer on the water subphase was very sensitive to its PH and temperature. The optimum condition of PH for the stable stearic acid LB film was 6$\sim$6.5. The PDA LB films were stable at the lower temperature than room temperature: we obtained very uniform PDA LB films at 12$^{\circ}C$.

  • PDF

Treatment of PDA in Premature Newborns with Mefenamic Acid (Mefenamic acid를 이용한 미숙아 동맥관 개존증 치험)

  • Lee, Jae-Joon;Lee, Young-Hwan;Shin, Son-Moon
    • Journal of Yeungnam Medical Science
    • /
    • v.10 no.2
    • /
    • pp.506-511
    • /
    • 1993
  • This study was conducted to examine the effect of mefenamic acid for treatment of PDA in premature newborns. Ductus arteriosus is reopened by locally produced prostaglandin $E_2$ in a premature newborn during hypoxia. Mefenamic acid is one of non-steroidal antiinflammatory drugs acting by inhibition of cyclo-oxygenase in the prostaglandin synthesis pathway. For three premature newborns with PDA, we administered mefenamic acid and evaluated them with echocardiography to study the effect of mefenmic acid for closure of PDA. In all three babies, ductus arteriosus was closed successfully. We feel that mefenamic acid is safe and effective medication for treatment of PDA in premature newborns, but further study need to be conducted with larger numbers of cases to confirm this effect.

  • PDF

Drivability of Offshore Pile Foundation at Ieodo Ocean Research Station (이어도 해양과학기지 말뚝기초의 항타 관입성 연구)

  • Shim, Jae-Seol;Yoon, Gil-Lim;Lee, Seung-Jun
    • Ocean and Polar Research
    • /
    • v.25 no.spc3
    • /
    • pp.373-384
    • /
    • 2003
  • When pile foundation is constructed by dynamic method, it is desirable to perform monitoring of drivability with pile penetration. Dynamic pile monitoring yields information regarding driving hammer, cushion, pile and soil behaviour that can be used to confirm the assumptions of wave equation analysis. In this study, dynamic monitoring of the steel pipe pile was performed with Pile Driving Analyser (PDA). The PDA utilizes the wave propagation theory to compute numerous variables which describe the conditions of the hammer-pile-soil system in real-time and following each hammer impact. This approach allows immediate field verification of hammer performance, driving efficiency, and estimation of pile bearing capacity. A series of PDA test were performed at the Ieodo Ocean Research Station (IORS) located in southeast of Marado, a southernmost small island south of Jeju Island. The drilling core sediments of Ieodo subsoil are composed of mud and sand, showing lamination and wavy or lenticular bedding, which were often bioturbated. This paper summarizes the results of PDA tests which were applied in measurement and estimation of large diameter open ended steel pipe pile driven by steam hammer, Vulcan-560 and MRBS-4600, at the marine sediments.

A study on effect on icon usability through exchanged interface design (인터페이스 전환에 따른 도상(Icon)의 형태가 사용성에 미치는 영향에 관한 연구)

  • Chung, Hye-Kyung;Lee, Hae-Jin;Kim, Jung-Yi
    • Proceedings of the Korea Society of Design Studies Conference
    • /
    • 2005.10a
    • /
    • pp.66-67
    • /
    • 2005
  • 기존의 데스크톱 컴퓨터가 고정된 공간에서만 사용되는데 반해 개인용 정보단말기(PDA)는 이동하면서 사용이 가능하다는 특징 때문에 소형화면과 작은 부피, 가벼운 용량의 특징을 지닌다. 그러나 이러한 제한된 화면에서는 한 번에 볼 수 있는 정보량이 적어 사용자 중심의 PDA용 GUI 아이콘 설계를 위해서는 우선 PC와 PDA간의 호환을 자유롭게 하는 인터페이스 디자인이 선행되어야 한다. 기존 소형화면에서는 한 번에 볼 수 있는 정보량이 적기 때문에 전체에 대한 개관이 불가능했고, 많은 정보를 담으면, 내용이해가 어려웠는데, 본 논문에서는 효율적인 GUI 아이콘 설계를 통해 정보의 ‘집중’과 ‘선택’ 이 가능한 PDA의 인터페이스 디자인을 알아보고자 한다. 대량 정보를 작은 화면에 종합적으로 담아내어 개관을 가능하게 하고, 정보의 내용과 가치를 아이콘의 크기와 색, 수직 혹은 수평적인 움직임 등의 시각화를 통해 차별화시킴으로써 개별 정보내용의 이해를 가능하게 한다. 앞으로 PDA와 PC의 표준화된 호환 가능한 브라우저가 모든 PDA에 기본 인터페이스로 장착된다면, 다른 매체들 간의 데이터 전송 시스템의 호환을 순조롭게 하여 경제적인 파급 효과 뿐만 아니라 차세대 이동통신의 영역까지 확장하여 산업적인 파급효과도 클 것으로 예상된다.

  • PDF

Transjugular occlusion of patent ductus arteriosus using an Amplatz canine ductal occluder in a Cocker spaniel dog

  • Choi, Ran;Hyun, Changbaig
    • Korean Journal of Veterinary Research
    • /
    • v.50 no.1
    • /
    • pp.49-53
    • /
    • 2010
  • A 5-year-old female Cocker spaniel dog (body weight 7.0 kg) was presented with primary complaints of exercise intolerance and loud precordial thrill which was noticed since she was a puppy. Physical examination revealed a grade V/VI continuous murmur over the maximal point of the left basal area, bounding femoral pulse, but no differential cyanosis. Tall R waves were detected in electrocardiogram, suggesting left ventricular enlargement. Diagnostic imaging studies showed enlarged left ventricle, bulged descending aorta (dAo), markedly dilated right pulmonary artery, and continuous shunt flow between the dAo and main pulmonary artery. Based on these findings, the dog was diagnosed as left to right shunted patent ductus arteriosus (PDA). The patent ductus arteriosus was treated by lodging a PDA duct occluder via the transvenous approach. Clinical signs were markedly improved after the ductal occlusion, the shunt flow was mildly persistent. The case presented is the first case of PDA occluded by the PDA duct occluder via the transvenous approach in a small breed of dog. Although the residual shunt flow was mildly persisted, the dog was clinically normal without detectable murmurs.

Evaluation of echocardiographic markers in dogs with patent ductus arteriosus after ductal closure

  • Park, Jong-In;Suh, Sang-IL;Hyun, Changbaig
    • Korean Journal of Veterinary Research
    • /
    • v.56 no.4
    • /
    • pp.209-213
    • /
    • 2016
  • This study evaluated several known echocardiographic markers related to the assessment of severity in dogs with patent ductus arteriosus (PDA) after the closure of ductus arteriosus (DA). Forty-two dogs with patent ductus arteriosus were enrolled in this study. Evaluated echocardiographic markers were left atrial to aortic root ratio, left ventricular end-diastolic dimension to aortic root ratio, indexed left ventricular end-diastolic and end-systolic dimensions, end-diastolic and end systolic volume index, pulmonic flow to systemic flow (Qp/Qs) ratio, velocities of pulmonary regurgitant and systolic jets, pulmonary flow profiles and the presence of mitral regurgitation. Those markers were evaluated before, 1 day, and 30 days after the closure of DA. Statistically significant changes in some echocardiographic markers (i.e., Qp/Qs) were observed. Although several studies in human and dogs have evaluated the clinical outcome of PDA occlusion using several echocardiographic markers, this study has firstly evaluated all echocardiographic markers known to be useful for assessing the clinical outcome of PDA occlusion in human, and has demonstrated that those markers including the Qp/Qs and pulmonary flow profiles were useful in evaluating of clinical outcome of PDA in dogs and the reduction of LA and LV preload after ductal closure could dramatically reduce after successful ductal occlusion of PDA in dogs.

Surgical treatment of pulmonary atresia -2 cases- (폐동맥 폐쇄증 (Pulmonary atresia)의 외과적 치료 -2예 보고-)

  • 강경훈
    • Journal of Chest Surgery
    • /
    • v.19 no.3
    • /
    • pp.464-469
    • /
    • 1986
  • Pulmonary atresia with intact ventricular septum, and with VSD were uncommon congenital anomalies with high mortality in the neonatal period. Those survivals depend on an adequate interatrial communication or interventricular communication and pulmonary flow via large aortopulmonary collateral including PDA. Recently we experienced surgical correction of 2 cases pulmonary atresia with intact ventricular septum and with VSD. On case 1, 10-years old male patient was confirmed as pulmonary valvular membranous atresia with intact ventricular septum combined with large functioning PFO and mild tricuspid incompetence. So we performed total correction under the E.C.C, that was PDA ligation, RVOT reconstruction with monocusp valved outflow patch [16mm], repair of tricuspid insufficiency and closure of PFO. Post-operative hemodynamic result was good and there was no event during hospital course. On case 2, 16-years old female patient was diagnosed as pulmonary atresia with VSD and PDA. MPA was absent, remained fibrous cord like remnant and type of VSD was subaortic defect [3cm by 3cm in the size]. PDA was located at the usual site. Under the E.C.C. VSD patch closure through the right ventriculotomy, anastomosis between the right ventricular outflow tract and the pulmonary bifurcated site with the extra-cardiac Hancock valved conduit [22cm] and PDA ligation were performed.

  • PDF