• 제목/요약/키워드: PD measurement system

검색결과 117건 처리시간 0.03초

휴대용 수면 패턴 모니터링을 위한 복합 fNIRS-EEG 시스템 개발 (Development of a Hybrid fNIRS-EEG System for a Portable Sleep Pattern Monitoring Device)

  • 김경한;우성우;하성훈;박금룡;사커 엠디 샤힌;박배정;김창세
    • 대한의용생체공학회:의공학회지
    • /
    • 제44권6호
    • /
    • pp.392-403
    • /
    • 2023
  • This study presents a new hybrid fNIRS-EEG system to meet the demand for a lightweight and low-cost sleep pattern monitoring device. For multiple-channel configuration, a six-channel electroencephalogram (EEG) and a functional near-infrared spectroscopy (fNIRS) system with eight photodiodes (PD) and four dual-wavelength LEDs are designed. To enhance the convenience of signal measurement, the device is miniaturized into a patch-like form, enabling simultaneous measurement on the forehead. Due to its fully integrated functionality, the developed system is advantageous for performing sleep stage classification with high-temporal and spatial resolution data. This can be realized by utilizing a two-dimensional (2D) brain activation map based on the concentration changes in oxyhemoglobin and deoxyhemoglobin during sleep stage transitions. For the system verification, the phantom model with known optical properties was tested at first, and then the sleep experiment for a human subject was conducted. The experimental results show that the developed system qualifies as a portable hybrid fNIRS-EEG sleep pattern monitoring device.

DC 정류기 부분방전 신호검출을 위한 SHF 센서의 성능평가 (Performance Evaluation of SHF Sensor for Partial Discharge Signal Detection on DC Rectifier)

  • 정호성;박영;나희승;장순호
    • 전기학회논문지
    • /
    • 제61권7호
    • /
    • pp.1056-1060
    • /
    • 2012
  • Online monitoring system is becoming an essential element of railway traction system for utilized to condition based malignance management and various techniques currently employed in railway traction system. Among the various techniques, it is efficient to detect partial discharge signals by electromagnetic wave detection in order to detect insulation fault of rectifier. Although VHF (Very High Frequency), UHF (Ultra High Frequency) sensors were adopted to detect partial discharge of power facilities, due to characteristics of urban railway, excessive noise occurs from 500 MHz to 1.5 GHz on UHF bandwidth. In this paper a new measurement system able to monitoring the conditions of power facilities on DC substation in metro was studied and set up. The system uses UHF sensors to measure the partial discharge of the rectifier due to electric faulting and dielectric breakdown. Comparison and estimation for performance of SHF sensor which had devised to detect partial discharge signal of urban railway rectifier has conducted. In order to estimate performance of SHF sensor, we have compared the sensor with existing UHF sensor on sensitivity upon frequency bandwidth generated by pulse generator, and also we have verified performance of the SHF sensor by detection results of partial discharge signal from urban railway rectifier.

$^{99m}Tc-DMSA$ 신티그램을 이용한 신질환 형태 분류 (Morphological classification of Renal Disease Using $^{99m}Tc-DMSA$ Scintigram)

  • 문태용
    • 대한핵의학회지
    • /
    • 제25권2호
    • /
    • pp.237-244
    • /
    • 1991
  • $^{99m}Tc-DMSA$ renal scan has been evaluated not only the renal functional cell mass but also some anatomical structures at a loss of the renal parenchymal function. The author classified a renal morphology of the posterior image of $^{99m}Tc-DMSA$ renal scan as the groups of symmetric and asymmetric morphology, the groups of the large, normal and small sized kidneys, the groups of the central photon defects (PD) which could be noted in a dilated pelvocalyceal system due to obstructive uropathy and the cortical photon defects (CD) due to focal parenchymal lesions or scars after a loss of function and the last groups of the single and multiple CD for a suggestion of the clinical usefulness. Regarding to measurement of normal renal size, the longest size of the kidneys were evaluated with 5 cm of a lead scale on the posterior renal image, and those were decided to the limits beteen 104.1 and 119.4 mm as comparison with the renal size of intravenous pyelogram (IVP) in 59 cases who were underwent $^{99m}Tc-DMSA$ and IVP concommitantly. Among 85 cases of PD in $^{99m}Tc-DMSA$ renal scan, the 61 (71.8%) were cases of a dilated pelvocalyceal system related with obstructive uropathy, meanwhile the 28 (27.0%) of 162 cases with CD were cases of obstructive and infectious uropathy. The probability of a presence of some uropathy in cases of CD were 99.3%, meanwhile that of the presence of CD in cases of some uropathy were 37.9%. Besides, there were some specific anatomical findings such as polycystic kidneys with symmetric enlarged kidneys with multiple CD and the kidneys of chronic renal failure and/or hypertension with symmetric small size in $^{99m}Tc-DMSA$ renal stan.

  • PDF

전력설비 보호를 위한 분배형 광섬유 온도센서 (Distributed Fiber-Optic Temperature Sensor Network for Protection of Electric Power Systems)

  • 박형준;이준호;송민호
    • 조명전기설비학회논문지
    • /
    • 제20권5호
    • /
    • pp.64-71
    • /
    • 2006
  • 전력설비의 비정상적인 온도변화를 감시할 목적으로 10개의 광섬유격자를 이용하여 $1[^{\circ}C]$ 이내의 온도분해능을 가지는 준분배형 광섬유 온도센서를 제작하였다. 파장가변 FP 필터를 스캔하여 얻어지는 PD 출력파형의 피크위치를 검색하여 광섬유격자 센서의 출력변화를 읽어내었고, 가우시안 line-fitting 알고리즘으로 광섬유격자의 반사스펙트럼 왜곡에 의한 영향을 보상하고 정밀도를 향상시켰다. 제작한 센서시스템과 기준 온도계로 사용한 thermocouple 간의 측정값 오차는 1[%] 이내이며, 선형화 오차는 약 0.37[%]으로 측정되었다.

포켈스센서를 이용한 코로나방전 발생시의 전계변화 측정에 관한 연구 (A possible non-contact measuring technique for the variation of the electric field due to corona discharge by use of Pockels sensor)

  • 마지훈;강원종;임윤석;최재옥;장용무;구자윤
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 연구회
    • /
    • pp.189-192
    • /
    • 2001
  • In this paper, an novel optical measuring system based on the electro-optic effect has been proposed and realized using Pockels cell with a view to detecting partial discharge taking place at the needle plane electrode. This system has the following advantages ; nonmetallic probe sensor, immune to external EMI noise and broad band response of the Pockels cell from DC to GHz. This system is constructed by He-Ne laser, Mach-Zehnder interferometer with Pockels sensor, balanced photo receiver, data acquisition board and PC. The response characteristics of the developed proto type sensor are examined for AC and corona discharge.

  • PDF

외란관측기를 이용한 서로계의 통합설계 (Integrated Design of Servomechanisms Using a Disturbance Observer)

  • 김민석;정성종
    • 대한기계학회논문집A
    • /
    • 제29권4호
    • /
    • pp.591-599
    • /
    • 2005
  • This paper proposes a systematic design methodology for high-speed/high-precision servomechanisms by using a disturbance observer. A multiplicative uncertainty model and a two degree-of-freedom controller composed of a disturbance observer (DOB) and a PD controller are considered as subsystems. Analysis of the system performance, such as internal stability and bandwidth of a servomechanism according to subsystem parameters is conducted for better understanding of the dynamic behavior and interactions among the subsystem parameters. Then, an integrated design methodology, where the interactions are considered simultaneously, is applied to design processes of the servomechanism. The tradeoff relationship between disturbance suppression and measurement noise rejection of the DOB is considered through the design process. Numerical case studies show the improved possibility to evaluate and optimize the dynamic motion performance of the servomechanism. Moreover, the disturbance observer designed based on the proposed design methodology yields excellent disturbance suppression performance.

전력설비 보호를 위한 온도계전기용 광섬유 분배센서 (Distributed fiber-optic sensor network for the over temperature protection relay of electric power systems)

  • 박형준;이준호;송민호
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.86-90
    • /
    • 2006
  • We prosed a distributed fiber-optic sensor system with 10 fiber Bragg gratings, for over temperature protection relay in power systems. We applied Gaussian line-fitting algorithm to compensate the distortion effects in the wavelength-scanned Farby-Perot filter demodulation scheme. Compared with the highest-peak-detection method, the proposed algorithm was proved to minimize the random errors of distorted PD profiles. From experimental results, the overall measurement error was within 1 % compared with the reference thermocouple and the linearity error was less than 0.37 %.

  • PDF

PI 관측기 기반 반도체 장비 모터의 궤적 추종 제어기 설계 (Trajectory Tracking Controller for Semiconductor Equipment Motors based on PI Observer)

  • 조윤성;최현준;전상민;신지훈;이재영;이범주;손영익
    • 반도체디스플레이기술학회지
    • /
    • 제22권2호
    • /
    • pp.96-103
    • /
    • 2023
  • This paper presents a robust position tracking controller for a motor used in semiconductor equipment, utilizing the motor angle measurement. Precise position control is challenging due to the presence of uncertainties in various motor applications. The proposed controller consists of a PD (Proportional-Derivative) controller and a PIO (Proportional-Integral Observer) to estimate the system's state and equivalent disturbance compensating for the uncertainties. Since the stability alternates as the observer gain increases, we have investigated it through the closedloop root locus under the system parameters change. The analysis has showed that the inertia of the motor is the main parameter that affects it, and by adjusting the control gain appropriately, the system can be rendered to be stable even when the inertia of the motor changes. The effectiveness of the proposed control algorithm is validated through computer simulations, followed by a comparison of its performance with the results of a previous study.

  • PDF

BSO와 ZnSe를 광 변조기로 이용한 전류센서에 관한 연구 (A Study on the Current Sensor Using an Optical Modulator with BSO)

  • 김요희;이대영
    • 전자공학회논문지A
    • /
    • 제28A권9호
    • /
    • pp.721-728
    • /
    • 1991
  • In this paper, a magneto-optic modulator has been designed by using single crystal BSO and polycrystal ZnSe as Faraday cells. And practical core-type optical current sensors using pure iron and permalloy have been prepared and experimented. In order to obtain efficient magnetic field detection, LED(NEC OD08358, 0.87 $\mu$m) was used as optical source, PIN-PD(OD-8454)as optical receiver and multi-mode optical fiber (100/140$\mu$m) as transmission line. The characteristics matrix of the optical element was calculated by Stokes parameter, and optic modulation characteristics equations were derived by Muller matrix. Electromagnetic analysis program (FLUX 2D, micro VAX 3600) by finite element method was used to find the magnetic flux density around the core. The measuring error of the output voltage to input current has been masured below 5% in the range of 50A to 1000A. As the temperature was changed from -20$^{\circ}C$ to 60$^{\circ}C$, the maximum measurement error of the optical output has been found to be 0.5% at 60$^{\circ}C$. These experimental results show good temperature and linearity characteristics. The SNR of the overall system was 47dB in case of 600A (250.2 Oe) conductor current and the system has good noise immunity.

  • PDF

복합레진의 초기 동적 체적 중합수축의 실시간 측정 -새로운 측정장치의 개발에 대한 소고- (A NEW METHOD - REAL TIME MEASUREMENT OF THE INITIAL DYNAMIC VOLUMETRIC SHRINKAGE OF COMPOSITE RESINS DURING POLYMERIZATION)

  • 이인복
    • Restorative Dentistry and Endodontics
    • /
    • 제26권2호
    • /
    • pp.134-140
    • /
    • 2001
  • The polymerization shrinkage of composite resins is an important drawback although the composites have many advantages-more esthetic and conservative than metallic restoratives etc. The purposes of this research were to develop a new measurement method and to manufacture an instrument that can measure the initial dynamic volumetric shrinkage of composite resins during polymerization. The instrument was basically an electromagnetic balance that constructed with a force transducer using position sensitive photo detector(PSPD) and a negative feedback servo amplifier of proportional-derivative(PD) controller. The volumetric change of composites during polymerization was detected continuously as buoyancy change in distilled water by means of Archimedes's principle. It was converted to continuous electrical voltage signal in real time. The signal was properly conditioned and filtered and then it was stored in computer by a data acquisition(DAQ) board. By using this electronic instrument. the dynamic patterns of the polymerization shrinkage of eight commercial(Z-100, DenFil, AeliteFil, Z-250, P-60, SureFil, Synergy compact, and Tetric ceram) composite resins were measured and compared. The results were as follows. 1. From this project of developing instrument, the ability has been achieved that can acquire and process data of electrical signal transformed from various physical phenomenon by using temperature, displacement. photo. and force transducer. As a consequence, the instrumentation and measurement system used to analyze the physical characteristics of various dental materials in dental research field can be designed, manufactured and implemented in lab. 2. This instrument has some advantages. It was insensible to temperature change and could measure true dynamic volumetric shrinkage in real time without complicated process. It showed accuracy and high precision results with small standard deviation. 3. The polymerization shrinkage of composites was significantly different between brands and ranged from 2.47% to 3.89%, The order of polymerization shrinkage was as follows, in order of increasing shrinkage, SureFil, P60, Z250, Z100, Synergy compact. DenFil, Tetric ceram, and AeliteFil. 4. The polymerization shrinkage rate per unit time, dVol%/dt, showed that the instrument can provide an indirect research method for polymerization reaction kinetics.

  • PDF