• Title/Summary/Keyword: PD Index

Search Result 137, Processing Time 0.029 seconds

Smart Information Facilities as Knowledge Based Spacial System - Case Study of Information Facility Layout - (스마트 정보시설 디자인 차별화 유형 - 정보시설 배치계획 사례를 중심으로 -)

  • Kimm, Woo-Young
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.9
    • /
    • pp.3-8
    • /
    • 2018
  • In the social information facilities with physical stacks, it is critical to arrange categories of knowledge since there should be conventional methods by which users and visitors can browse index of all sorts of media relating to their topics. The classical index system of knowledge has been developed with primitive libraries and museums and therefore the system can be addressed by analyzing typical cases of precedents. As the forth industrial revolution has emerged, there will be quite innovative approach to provide information to the public as well as the private. The coalition between knowledge and space has always been considered as essential characteristics that remind scholars of hierarchical layout of knowledge resources such as maps, books, documents and diverse specimens. This research assumes that the spatial layout of knowledge can be classified in terms of physical attributes, symbolic entities, and information media and it defines what coalition between knowledge and space is creative in order to enacting interactive dialogue among information navigators. The spaces in between the knowledges function as trasition areas where the index system informs and stimulates, where the interface between the different knowledges is optimized and therefore the library as the public facilities no longer dedicated to the text, but as an information space in which all sorts of media are distributed equally.

Construction of Spatial Information Big Data for Urban Thermal Environment Analysis (도시 열환경 분석을 위한 공간정보 빅데이터 구축)

  • Lee, Jun-Hoo;Yoon, Seong-Hwan
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.36 no.5
    • /
    • pp.53-58
    • /
    • 2020
  • The purpose of this study is to build a database of Spatial information Bigdata of cities using satellite images and spatial information, and to examine the correlations with the surface temperature. Using architectural structure and usage in building information, DEM and Slope topographical information for constructed with 300 × 300 mesh grids for Busan. The satellite image is used to prepare the Normalized Difference Built-up Index (NDBI), Normalized Difference Vegetation Index (NDVI), Bare Soil Index (BI), and Land Surface Temperature (LST). In addition, the building area in the grid was calculated and the building ratio was constructed to build the urban environment DB. In architectural structure, positive correlation was found in masonry and concrete structures. On the terrain, negative correlations were observed between DEM and slope. NDBI and BI were positively correlated, and NDVI was negatively correlated. The higher the Building ratio, the higher the surface temperature. It was found that the urban environment DB could be used as a basic data for urban environment analysis, and it was possible to quantitatively grasp the impact on the architecture and urban environment by adding local meteorological factors. This result is expected to be used as basic data for future urban environment planning and disaster prevention data construction.

Extrusion-cooking Using Twin-screw Extruder on Cordyceps Pruinosa (이축 압출 성형기를 이용한 붉은자루 동충하초의 압출 성형)

  • Kim D. E.;Sung J. M.;Kang W. S.
    • Journal of Biosystems Engineering
    • /
    • v.30 no.1 s.108
    • /
    • pp.8-16
    • /
    • 2005
  • The extrusion-cooking condition on Cordyceps pruinosa was designed using twin-screw extruder. Response surface methodology (RSM) was used to investigate extrusion-cooking using a central composition design with varying die temperature $(114-146^{\circ}C)$, feed moisture $(22-38\%)$, feed rate (4-14 ka/h) and screw speed (120-280 rpm). System parameters (die pressure and specific mechanical energy (SME)) and extrudate parameters (density and water solubility index (WSI)) were statically analyzed using RSH. Die pressure was significantly affected by temperature, moisture contents and feed rate. SM was affected by screw speed and feed rate. When die temperature is $130^{\circ}C$ and moisture content $25\%$, the optimum pressure is shown. SME is about 20 Wh/kg, when feed rate is $10\~12kg/min$ and screw speed $200\~250rpm$. WSI was affected by temperature and moisture contents. Density was not affected by any factor. WSI increases by $7\%$ from about $23\%$ to about $30\%$, as temperature is raised from $120^{\circ}C\;to\;140^{\circ}C$. The WSI of Cordyceps pruinosa pulverized after extruding (PE) is about $26.97\%$ higher than that of raw material and $10\%$ higher than that of pulverized after drying (PD). The content of unsaturated fatty acid were not significantly different in PD and PE. Anti-oxidative activity of PE was 1.67-2.2 times higher than that of PD in Cordyceps pruinosa using 1- dipheny1-2-picrylhydrazyl method (DPPH).

Cost Effective Silica-Based 100 G DP-QPSK Coherent Receiver

  • Lee, Seo-Young;Han, Young-Tak;Kim, Jong-Hoi;Joung, Hyun-Do;Choe, Joong-Seon;Youn, Chun-Ju;Ko, Young-Ho;Kwon, Yong-Hwan
    • ETRI Journal
    • /
    • v.38 no.5
    • /
    • pp.981-987
    • /
    • 2016
  • We present a cost-effective dual polarization quadrature phase-shift coherent receiver module using a silica planar lightwave circuit (PLC) hybrid assembly. Two polarization beam splitters and two $90^{\circ}$ optical hybrids are monolithically integrated in one silica PLC chip with an index contrast of $2%-{\Delta}$. Two four-channel spot-size converter integrated waveguide-photodetector (PD) arrays are bonded on PD carriers for transverse-electric/transverse-magnetic polarization, and butt-coupled to a polished facet of the PLC using a simple chip-to-chip bonding method. Instead of a ceramic sub-mount, a low-cost printed circuit board is applied in the module. A stepped CuW block is used to dissipate the heat generated from trans-impedance amplifiers and to vertically align RF transmission lines. The fabricated coherent receiver shows a 3-dB bandwidth of 26 GHz and a common mode rejection ratio of 16 dB at 22 GHz for a local oscillator optical input. A bit error rate of $8.3{\times}10^{-11}$ is achieved at a 112-Gbps back-to-back transmission with off-line digital signal processing.

Influence of Transcutaneous Electrical Nerve Stimulation and Electroacupuncture on C-fos Expression in Spinal Cord and Functional Recovery After Rat Sciatic Nerve Crush Injury (경피신경전기자극과 전침자극이 흰쥐 좌골신경 압좌손상 후 척수내 c-fos 발현과 기능회복에 미치는 영향)

  • Lee, Hyun-Min
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.6
    • /
    • pp.187-195
    • /
    • 2009
  • The purpose of this study was to identify the effect of transcutaneous electrical nerve stimulation(TENS) and electroacupuncture(EA) after sciatic nerve crush injury in rats. Subjects were classified TENS group with TENS application, EA group with EA application and Control group which is not applicated electrical stimulation. TENS and EA stimulations were applied post-injury day(PD) 1 to 14 after sciatic nerve injury. This study observed c-fos expression in rat lumbar spinal cord. In addition, the paw withdrawal latency(PWL) and sciatic function index(SFI) were measured. The results were as follows: At PD 1, control group had higher c-fos immunoreactivity than experimental groups. At PD 7 and 14, control group had higher c-fos immunoreactivity than experimental groups. The PWL of experimental groups were significantly lower than control group. The SFI had not significant difference in all groups. But the average of experimental groups were higher than control group. These results suggest that TENS and EA applications increasing sensory and motor nerve recovery while decreasing c-fos immunoreactivity after sciatic nerve crush injury.

Synthesis of T2-weighted images from proton density images using a generative adversarial network in a temporomandibular joint magnetic resonance imaging protocol

  • Chena, Lee;Eun-Gyu, Ha;Yoon Joo, Choi;Kug Jin, Jeon;Sang-Sun, Han
    • Imaging Science in Dentistry
    • /
    • v.52 no.4
    • /
    • pp.393-398
    • /
    • 2022
  • Purpose: This study proposed a generative adversarial network (GAN) model for T2-weighted image (WI) synthesis from proton density (PD)-WI in a temporomandibular joint(TMJ) magnetic resonance imaging (MRI) protocol. Materials and Methods: From January to November 2019, MRI scans for TMJ were reviewed and 308 imaging sets were collected. For training, 277 pairs of PD- and T2-WI sagittal TMJ images were used. Transfer learning of the pix2pix GAN model was utilized to generate T2-WI from PD-WI. Model performance was evaluated with the structural similarity index map (SSIM) and peak signal-to-noise ratio (PSNR) indices for 31 predicted T2-WI (pT2). The disc position was clinically diagnosed as anterior disc displacement with or without reduction, and joint effusion as present or absent. The true T2-WI-based diagnosis was regarded as the gold standard, to which pT2-based diagnoses were compared using Cohen's ĸ coefficient. Results: The mean SSIM and PSNR values were 0.4781(±0.0522) and 21.30(±1.51) dB, respectively. The pT2 protocol showed almost perfect agreement(ĸ=0.81) with the gold standard for disc position. The number of discordant cases was higher for normal disc position (17%) than for anterior displacement with reduction (2%) or without reduction (10%). The effusion diagnosis also showed almost perfect agreement(ĸ=0.88), with higher concordance for the presence (85%) than for the absence (77%) of effusion. Conclusion: The application of pT2 images for a TMJ MRI protocol useful for diagnosis, although the image quality of pT2 was not fully satisfactory. Further research is expected to enhance pT2 quality.

Association between Periodontitis and Coronary heart disease in Korea : Inflammatory markers and IL-1 gene polymorphism (한국인에서 치주질환과 관상동맥질환의 관련성에 대한 염증표지자와 IL-1 유전자 다변성의 영향)

  • Jeong, Ha-Na;Chung, Hyun-Ju;Kim, Ok-Su;Kim, Young-Joon;Kim, Ju-Han;Koh, Jung-Tae
    • Journal of Periodontal and Implant Science
    • /
    • v.34 no.3
    • /
    • pp.607-622
    • /
    • 2004
  • Recently epidemiologic studies have indicated that the patients with periodontitis may have increased risk of ischemic cardiovascular events, and have suggested the important roles of blood cytokines and acute reactant proteins in the systemic infection and inflammatory response. Periodontitis and coronary heart disease (CHD) may share the common risk factors and the genetic mechanism associated with interleukin(IL)-1A, B and RA genotype may be involved in the production of IL-1. This study was aimed to investigate the relationship between angiographically defined CHD and periodontitis as chronic Gram-negative bacterial infection and to determine whether the IL-1 gene polymorphism is associated in both diseases. Patients under the age of 60 who had undergone diagnostic coronary angiography were enrolled in this study. Subjects were classified as positive CHD (+CHD, n=37) with coronary artery stenosis more than 50% in at least one of major epicardial arteries, and negative CHD (-CHD, n=30) without significant stenosis. After recording the number of missing teeth, periodontal disease severity was measured by means of plaque index (PI), gingival index (GI), bleeding on probing (BOP), probing depth (PD), clinical attachment level (CAL), and radiographic bone loss around all remaining teeth. Gingival crevicular fluid (GCF) was collected from the 4 deepest periodontal pockets and assessed for cytokine ($IL-1{\beta}$, IL-6, IL-1ra, tumor necrosis $factor-{\alpha}$, and prostaglandin $E_2$). Additionally, blood CHD markers, lipid profile, and blood cytokines were analyzed. IL-1 gene cluster genotyping was performed by polymerase chain reaction and enzyme restriction using genomic DNA from buccal swab, and allele 2 frequencies of IL-1A(+4845), IL-1B(+3954), IL-B(-511), and IL-1RA(intron 2) were compared between groups. Even though there was no significant difference in the periodontal parameters between 2 groups, GCF level of $PGE_2$ was significantly higher in the +CHD group(p<0.05). Correlation analysis showed the positive relationship among PD, CAL and coronary artery stenosis(%) and blood $PGE_2$. There was also significant positive relationship between the periodontal parameters (PI, PD, CAL) and the blood CHD markers (leukocyte count, C-reactive protein, and lactic dehyrogenase). IL-1 gene genotyping showed that IL-1A(+3954) allele 2 frequency was significantly higher in the +CHD group compared with the -CHD group (15% vs. 3.3%, OR 5.118,p=0.043). These results suggested that periodontal inflammation is related to systemic blood cytokine and CHD markers, and contributes to cardiovascular disease via systemic inflammatory reaction. IL-1 gene polymorphism might have an influence on periodontal and coronary heart diseases in Korean patients.

Lipoprotein and Lipid Abnormalities in Uremic Children with Maintenance Dialysis (투석 치료중인 만성 신부전 소아에서의 지질 및 지질단백 이상)

  • Kim Jung-Sue;Song Jung-Han;Park Hye-Won;Cheong Hae-Il;Kim Jin-Q;Choi Yong;Ko Kwang-Wook
    • Childhood Kidney Diseases
    • /
    • v.1 no.2
    • /
    • pp.109-116
    • /
    • 1997
  • Purpose : Chronic renal failure is often accompanied by severe dyslipidemia, a known risk factor for cardiovascular disease. Lipoprotein(a) [Lp(a)] has recently been characterized as a risk factor for atherosclerosis and thrombosis. Cardiovascular disease is the leading cause of death in adult patients on dialysis. However, there are only limited data available concerning risk factors for atherosclerosis in uremic children. We have measured serum levels of lipids, lipoproteins, apolipoproteins and Lp(a) in uremic children with maintenance dialysis. Methods : Ten uremic children with hemodialysis (HD) and 14 with peritoneal dialysis (PD) in our dialysis unit were included in this study. The mean age of HD patients was $162{\pm}59$ months and the male to female ratio was 7:3. The mean age and sex ratio of PD patients were $123{\pm}63$ months and 6:8, respectively. The levels of cholesterol, triglyceride, lipoproteins, apolipoproteins and Lp(a) were measured from serum sampled after 14 hours of fasting. The normal control levels were cited from 2 articles presenting the normal blood lipid and lipoprotein levels of primary school and middle school children in Korea. Results : There was no difference in age, sex ratio, body mass index and duration of dialysis between the HD and the PD group. The serum concentration of the cholesterol, triglyceride and apolipoprotein B were significantly elevated in dialysis patients compared with normal subjects. The serum level of Lp(a) was significantly elevated in only PD group. The serum Lp(a) level was below 30 mg/dl in 13 and above 30 mg/dl in 11 patients. The serum albumin level was significantly decreased in high Lp(a) group than in low Lp(a) group. Conclusion : The uremic children receiving dialysis reveal abnormal serum lipid and lipoprotein profiles. These results suggest that they have a higher risk for coronary heart disease, although there has been no clinical evidence of coronary heart disease at present. A long-term follow-up study of these children to clarify the suggestion should be started now.

  • PDF

Clinical effect of smoking on the healing response following scaling and root planing (흡연이 비외과적 치주치료 후 치유반응에 미치는 임상적 영향)

  • Shim, Ji-Yeon;Kim, Tae-Il;Seol, Yang-Jo;Lee, Yong-Moo;Ku, Young;Rhyu, In-Chul;Chung, Chong-Pyoung;Han, Soo-Boo
    • Journal of Periodontal and Implant Science
    • /
    • v.36 no.1
    • /
    • pp.125-137
    • /
    • 2006
  • 1. 목적 흡연은 치주질환의 주요한 위험 인자 중의 하나이다. 일반적으로 흡연자는 비흡연자보다 비외과적 및 외과적 치주치료에 대한 반응이 덜 효과적인 것으로 알려져 있다. 이 연구에서는 중등도의 만성 치주염이 존재하는 한국인 흡연자와 비흡연자를 대상으로 하여, 비외과적 치주치료인 치석 제거술과 치근 활택술을 시행한 후 6개윌 동안의 임상적 치유 반응을 비교해 보고자 하였다. 2. 방법 20명의 중등도 만성 치주염 환자(흡연자 10명, 비흡연자 10명)를 대상으로 치주낭 깊이(Probing Pocket Depth, PPD), 치은퇴축(GR), 치주탐침시 출혈유무(BOP), #16, 12, 24, 32, 36, 44의 치태지수(Plaque Index, Silness & $L{\"{o}}e$ 1964)를 임상변수로 측정하였다. 치주낭 깊이 (PD)와 치은퇴축(GR)은 전자 탐침(Florida $Probe^{(R)}$ Co. Gainesville, FL)을 이용하여 각 치아당 6군데를 측정하였다. 임상적 부착 수준(CAL)은 치주낭 깊이(PD)와 치은퇴축(GR)의 합으로 계산하였다. 초진시에 전악 임상 검사를 시행하였고, 초진시의 치주낭 깊이에 따라 조사 대상이 되는 치아 부위를 선정하였다. 치주적으로 건강한 부위 $(PD{\leq}3mm)$를 대조군인 1군으로 하고 치주낭 깊이가 4 mm를 초과하고 5 mm 미만인 부위를 2군, 5 mm 이상의 치주낭 깊이를 가지는 부위를 3군으로 설정하였다. 비외과적 치주치료인 치석 제거술, 치근 활택술과 구강위생 교육을 시행하였고 2개월(T1), 4개윌(T2), 6개윌(T3)에 선정된 해당 치아 부위에 대해 임상 재검사를 시행하였다. 3. 결과 BOP와 Plaque Index는 초진, 2, 4, 6개월에 흡연자와 비흡연자 간에 유의할 만한 차이가 없었으나 전반적으로 감소하는 경향이 나타났다. 대조군인 l군에 서는 흡연자와 비흡연자 간에 모든 시기에서 PD, GR, CAL에 유의할 만한 차이가 없었다. 치주낭 깊이가 4 mm를 초과하고 5 mm 미만인 2군에서는 비흡연자에서 6개월에 유의할 만한 치주낭 깊이 감소가 나타났으며, 4개월과 6개윌에 유의할 만한 부착수준의 증가가 관찰되었다(p<0.05). 치주낭 깊이가 5 mm이상인 3군에서는 비흡연자에서 치주낭 깊이 감소가 일관되게 더 많이 나타났으나 통계학적으로 유의할 만한 차이는 6개월째에서만 관찰되었다. 2군과 유사하게 치주낭 갚이 감소는 흡연자보다 비흡연자에서 0.6 mm 더 크게 나타났다. 부착수준의 획득은 2군에서는 4, 6개월째에, 3군에서는 6개월째에 비흡연자에서 유의하게 더 많이 일어났다. 초진시의 치주낭 깊이와 각 시기별 ${\Delta}PD$ 간의 상관관계에서는 치주낭 갚이가 5mm 이상인 3군에서 비흡연자의 경우 6개월째에 가장 강한 상관성이 나타났다($r_s=0.43$, p<0.05). 흡연자에서는 3군에서 어떠한 유의한 상관관계도 나타나지 않았다. 결론적으로 중등도 만성 치주염 환자를 대상으로 한 6개윌의 단기간 연구에서 비외과적 치주치료 후 흡연자에서 비흡연자보다 치주낭 깊이 감소의 개선과 부착수준의 획득이 더 적게 나타나 임상적 치유반응이 좋지 않음을 확인하였다. 이는 흡연이 숙주의 치유반응 부정적인 영향을 주기 때문으로 생각된다.

Angled implant brush for hygienic maintenance of full-arch fixed-implant rehabilitations: a pilot study

  • Setti, Paolo;Pesce, Paolo;Dellepiane, Elena;Bagnasco, Francesco;Zunino, Paola;Menini, Maria
    • Journal of Periodontal and Implant Science
    • /
    • v.50 no.5
    • /
    • pp.340-354
    • /
    • 2020
  • Purpose: This pilot study was conducted to evaluate the cleaning efficacy of an angled implant brush for home oral hygiene of full-arch fixed-implant prostheses. Methods: Forty-one patients treated with a full-arch implant rehabilitation in the maxilla or mandible (164 implants) for at least 4 months were enrolled. The screw-retained fixed prostheses were removed and baseline (T0) parameters were recorded, including plaque index (PI), probing depth (PD), and bleeding on probing (BOP). All patients completed a 5-item questionnaire on hygiene maintenance and received an implant brush for home hygiene. After 1 month (T1) PI, PD, and BOP were recorded again and patients completed a 7-item questionnaire to evaluate their satisfaction with the implant brush. One-way repeated-measures analysis of variance was conducted to evaluate the significance of changes in PI, PD, and BOP. A P value <0.05 was considered to indicate statistical significance. Results: A statistically significant reduction of BOP (0.62±0.6 at T0 vs. 0.5±0.5 at T1; P=0.032) was found, while no statistically significant changes in PD (1.74±0.5 mm at T0 vs. 1.77±0.5 mm at T1; P=0.050) or PI (1.9±0.7 at T0 vs. 1.7±0.7 at T1; P=0.280) occurred. According to the 7-item questionnaire, patients reported no difficulty in using the angled brush (63.4%) and deemed it highly (46.3%) or very highly (4.8%) effective in improving their home oral hygiene. Conclusions: Within the limits of the present pilot study, the patients experienced a reduction of BOP 1 month after being instructed to use the angled implant brush. The angled implant brush appeared to be a well-accepted device for home-care hygiene of full-arch fixed-implant rehabilitations.