• Title/Summary/Keyword: PD Index

Search Result 137, Processing Time 0.028 seconds

Measure of Effectiveness Analysis of Active SONAR for Detection (능동소나 탐지효과도 분석)

  • Park, Ji-Sung;Kim, Jea-Soo;Cho, Jung-Hong;Kim, Hyoung-Rok;Shin, Kee-Cheol
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.16 no.2
    • /
    • pp.118-129
    • /
    • 2013
  • Since the obstacles and mines are of the risk factors for operating ships and submarines, the active sonar system is inevitably used to avoid the hazards in ocean environment. In this paper, modeling and simulation algorithm is used for active sonar systemto quantify the measure of mission achievability, which is known as Measure of Effectiveness(MOE), specifically for detection in this study. MOE for detection is directly formulated as a Cumulative Detection Probability(CDP) calculated from Probability of Detection(PD) in range and azimuth. The detection probability is calculated from Transmission Loss(TL) and the sonar parameters such asDirectivity Index (DI) calculated from the shape of transmitted and received array, steered beam patterns, and Reverberation Level (RL). The developed code is applied to demonstrating its applicability.

A Study on the Reversibility Scalar Phenomena in Amorphous Chalcogenides (비정질 칼코게나이드에서 광유기 스칼라 현상의 가역성에 관한 연구)

  • 박수호;정진만;이현용;정홍배
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.04a
    • /
    • pp.31-34
    • /
    • 1997
  • A reversible scalar phenomena in amorphous As$_{40}$ Ge$_{10}$ Se$_{15}$ S$_{35}$ have been investigated by blue-pass-filtered Hg lamp and He-Ne laser. Annealing causes the shift of the absorption edge to shelter wavelengths approximately 0.17ev, also illumination moves it to longer wavelengths about 0.05 ~ 0.07eV and it increases the refractive index maximum 0.3. Therefore the thermalbleaching(TB) and photodarkening(PD) effects have been understood by the results related to optical absorption characteristics. TB could be estimated as increasing the stabilization of amorphous chalcogenide films since absorption slope of extended regions(U) was not changed by annealing. On the other hand, PD could be understood as due to the enhancement of disorder since the slope of Urbach’s tail(1/F) around an absorption edge were decreased by illumination.ion.n.

  • PDF

Analysis of Insulation Condition in High Voltage Motor Stator Windings Following Cleaning and Insulation Reinforcement (세척과 절연보강에 따른 고압전동기 고정자 권선의 절연상태 분석)

  • Kim, Hee-Dong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.6
    • /
    • pp.474-480
    • /
    • 2012
  • Diagnostic tests were performed on two high voltage(HV) motor stator windings. These tests included the measurement of insulation resistance, polarization index, AC current, dissipation factor($tan{\delta}$) and partial discharge(PD) magnitude. Surface contamination of HV motor stator windings has an effect on the AC current and $tan{\delta}$. When the stator windings were finished cleaning and insulation reinforcement, the increase rate of AC current(${\Delta}I$) and dissipation factor(${\Delta}tan{\delta}$) were very small compared to those before cleaning. However, the PD magnitude remained the same. These tests show that cleaning and insulation reinforcement of HV motor stator windings can reduce the insulation failure.

Applying nano-HA in addition to scaling and root planing increases clinical attachment gain

  • Uysal, Ozge;Ustaoglu, Gulbahar;Behcet, Mustafa;Albayrak, Onder;Tunali, Mustafa
    • Journal of Periodontal and Implant Science
    • /
    • v.52 no.2
    • /
    • pp.116-126
    • /
    • 2022
  • Purpose: This study evaluated the efficacy of treating periodontitis using subgingival nano-hydroxyapatite powder with an air abrasion device (NHAPA) combined with scaling and root planing (SRP). Methods: A total of 28 patients with stage III periodontitis (grade B) were included in this study, although 1 was lost during follow-up and 3 used antibiotics. The patients were divided into a test group and a control group. All patients first received whole-mouth SRP using hand instruments, and a split-mouth approach was used for the second treatment. In the test group, the teeth were treated with NHAPA for 15 seconds at 70% power per pocket. Subgingival plaque samples were obtained from the 2 deepest pockets at the test and control sites before treatment (baseline) and 3 months after treatment. The full-mouth plaque index (PI), gingival index (GI), papillary bleeding index (PBI), bleeding on probing (BOP), probing depth (PD) and clinical attachment level (CAL) were recorded at baseline and at 1- and 3-month post-treatment. Real-time polymerase chain reaction was used to determine the colonisation of Treponema denticola (Td), Porphyromonas gingivalis (Pg), and Aggregatibacter actinomycetemcomitans in the subgingival plaque. Results: From baseline to the first month, the test group showed significantly larger changes in BOP and CAL (43.705%±27.495% and 1.160±0.747 mm, respectively) than the control group (36.311%±27.599% and 0.947±0.635 mm, respectively). Periodontal parameters had improved in both groups at 3 months. The reductions of PI, GI, BOP, PD, and CAL in the test group at 3 months were greater and statistically significant. The total bacterial count and Td and Pg species had decreased significantly by the third month in both groups (P<0.05). Conclusions: Applying NHAPA in addition to SRP improves clinical periodontal parameters more than SRP alone. Subgingival NHAPA may encourage clot adhesion to tooth surfaces by increasing surface wettability.

Photo-Induced Scalar Phenomena according to Thickness Dependence of Chalcogenide $As_{40}Ge_{10}Se_{15}S_{35}$ Thin Film (칼코게나이트 $As_{40}Ge_{10}Se_{15}S_{35}$ 박막에서 두께에 따른 광유기 스칼라 현상)

  • 이현용;박수호;정홍배
    • Electrical & Electronic Materials
    • /
    • v.10 no.5
    • /
    • pp.467-472
    • /
    • 1997
  • In this study, we investigated the thickness dependence of thermal bleaching(TB) effect as well as photo-induced scalar phenomena, such as photodrakening(PD) effect and photorefraction(PR) change, in chalcogenide A $s_{40}$ G $e_{10}$S $e_{15}$ $S_{35}$ thin films. We found that when these films were exposed for 15 minutes using blue-pass filtered Hg lamp(~4300$\AA$) after annealing for 30 minutes around the glass transition temperature Tg(20$0^{\circ}C$), the refractive index change ($\Delta$n) was varied up to 0.02~0.46 according to each thickness condition and the optical energy gap ($\Delta$ $E_{op}$ ) was shifted to a longer wavelength of approximately 0.67eV, especially for 1000$\AA$-thickness. Also, the TB PD effects have been understood by the results related to optical absorption characteristics. The TB effect could be estimated as increasing the stabilization of amorphous chalcogenide films since absorption slope of extended regions(U) was not changed by annealing. On the other hand, the PD effect could be understood as due to the enhancement of disorder since U and the slope of Urbachs tail(1/F) around an absorption edge were decreased by exposing.ing.n edge were decreased by exposing.

  • PDF

Reappraisal of Anatomic Outcome Scales of Coiled Intracranial Aneurysms in the Prediction of Recanalization

  • Lee, Jong Young;Kwon, Bae Ju;Cho, Young Dae;Kang, Hyun-Seung;Han, Moon Hee
    • Journal of Korean Neurosurgical Society
    • /
    • v.53 no.6
    • /
    • pp.342-348
    • /
    • 2013
  • Objective : Several scales are currently used to assess occlusion rates of coiled cerebral aneurysms. This study compared these scales as predictors of recanalization. Methods : Clinical data of 827 patients harboring 901 aneurysms treated by coiling were retrospectively reviewed. Occlusion rates were assessed using angiographic grading scale (AGS), two-dimensional percent occlusion (2DPO), and volumetric packing density (vPD). Every scale had 3 categories. Followed patients were dichotomized into either presence or absence of recanalization. Kaplan-Meier analysis was conducted, and Cox proportional hazards analysis was performed to identify surviving probabilities of recanalization. Lastly, the predictive accuracies of three different scales were measured via Harrell's C index. Results : The cumulative risk of recanalization was 7% at 12-month, 10% at 24-month, and 13% at 36-month of postembolization, and significantly higher for the second and third categories of every scale (p<0.001). Multivariate-adjusted hazard ratios (HRs) of the second and third categories as compared with the first category of AGS (HR : 3.95 and 4.15, p=0.004 and 0.001) and 2DPO (HR : 4.87 and 3.12, p<0.001 and 0.01) were similar. For vPD, there was no association between occlusion rates and recanalization. The validated and optimism-adjusted C-indices were 0.50 [confidence (CI) : -1.09-2.09], 0.47 (CI : -1.10-2.09) and 0.44 (CI : -1.10-2.08) for AGS, 2DPO, and vPD, respectively. Conclusion : Total occlusion should be reasonably tried in coiling to maximize the benefit of the treatment. AGS may be the best to predict recanalization, whereas vPD should not be used alone.

A Study on the Washability and Washing Conditions of the Industrial Alkaline Laundry Detergent Suitable for Water Discharge Standards and Detergent Regulations (수질 배출기준 및 세제 안전기준에 적합한 산업용 알칼리 세탁세제의 세척성과 세탁조건 연구)

  • Song, Hyunjoo;Song, Sunhye
    • Textile Coloration and Finishing
    • /
    • v.33 no.4
    • /
    • pp.250-257
    • /
    • 2021
  • Laundry industry has traditionally been considered an industry that generates large amounts of wastewater and Volatile Organic Compounds(VOCs). This is still the case until now. Household laundry detergents are produced and distributed within the safety regulations on the amount of harmful substances detected. While industrial laundry detergents are often distributed without safety regulations, and even laundry workers manufacture and use them on their own. This contaminates water and air and also threatens the safety of workers. This study is a basic study for distributing eco-friendly detergents(EFD-A) developed through previous studies to the laundry industry. Safety, washability and wastewater quality of EFD-A are evaluated. Three existing commercial detergents(PD1, PD2, LD4) are also evaluated to compare with EFD-A. The safety of detergents is confirmed by the content of optical brightener, VOCs, and arsenic. Washability is evaluated by the difference in reflectance of washed and unwashed artificial soiled fabrics according to detergent concentration, washing temperature, and washing time. TOC is used as the index of assessing the wastewater quality. The results are as follows; EFD-A doesn't contain the optical brighteners, VOCs, and arsenic. The optimal washing conditions for EFD-A are 3 g/L concentration, 40 ℃ washing temperature, and 30 min washing time. The soil removal efficiency is about 71 %, which was similar to or somewhat superior to that of PD1, PD2, and LD4. TOC is 63.5 %, which is about 15 % lower than the discharge limit. Through this study, the developed detergent EFD-A can be used as a safe and eco-friendly detergent for the human body and the environment.

Relationship of Saponin and Non-saponin for the Quality of Ginseng (인삼의 품질과 약리활성 물질과의 상관성)

  • Nam, Gi-Yeol;Go, Seong-Ryong;Choe, Gang-Ju
    • Journal of Ginseng Research
    • /
    • v.22 no.4
    • /
    • pp.274-283
    • /
    • 1998
  • It has generally been accepted that quality of ginseng should be determined not by the content of a single component but by composition and balance of total active principles. However, there still can be an exception with a product in which a given ginsenoside is used for the treatment of a specific disease. Although ginsenosides have been regarded to be major active components of ginseng and employed as index components for the quality control, it does not consistent with the traditional concept on ginseng quality creterion; main root has been more highly appreciated than the lateral or fine root. Content of ginsenosides in the lateral or fine root is much higher than that in main root. However, the ratio of protopanaxadiol (PD) and protopanaxatriol (PT) saponins existing in various part of ginseng root is greatly different. The ratio of PD/PT saponins in main root is well balanced but the thinner the root is the higher the ratio. Thus far, a total of 34 different kinds of ginsenosides have been isolated from Korean (red) ginseng, and their pharmacological activities were elucidated partly. Interestingly, different ginsenoside shows similar or contrary effects to each other in biological systems, thus indicating the significance of absolute content of single ginsenoside as well as compositional patterns of each ginsenoside. Therefore, pharmacological activities of ginseng should be determined as a wholly concept. In these regards, standardization of ginseng material (fresh ginseng root) should be preceded to the standardization of ginseng products because ginsenoside content and non-saponin active principles such as polysaccharides and nitrogen (N)-containing compound including proteins are significantly different from part to part of the root. In other words, the main root contains less ginsenosides than other lateral or fine roots. Contents of polysaccharides and N-containing compound in main root is higher. However, the quality control of ginseng products focused on non-saponin compounds has limitation in applying to the analytical method, because of the difficult chemical analysis of these compounds. Content of ginsenosides, and ratios of PD/PT and ginsenoside Rb,/Rg, are inversely proportional to the diameter of ginseng root. Therefore, these can be served as the chemical parameters for the indirect method of evaluating from what part of the root does the material originate. Furthermore, contents of polysaccharides and N-containing compounds show inverse relationship to saponin content. Therefore, it seems that index for analytical chemistry of saponin can be applied to the indirect method of evaluating not only saponin but also non-saponin compounds of ginseng. From these viewpoints, it is strongly recommended that quality of ginseng or ginseng products be judged not only by the absolute content of given ginsenoside but also by varieties and compositional balance of ginsenosides, including contents of non-saponin active principles.

  • PDF

Effect of scaling and root planing on the expression of anti-inflammatory cytokines (IL-4, IL-9, IL-10, and IL-13) in the gingival crevicular fluid of electronic cigarette users and non-smokers with moderate chronic periodontitis

  • Al-Hamoudi, Nawwaf;Alsahhaf, Abdulaziz;Deeb, Modhi Al;Alrabiah, Mohammed;Vohra, Fahim;Abduljabbar, Tariq
    • Journal of Periodontal and Implant Science
    • /
    • v.50 no.2
    • /
    • pp.74-82
    • /
    • 2020
  • Purpose: The aim of this cross-sectional study was to investigate the effect of scaling and root planing (SRP) on the expression of anti-inflammatory cytokines (interleukin [IL]-4, IL-9, IL-10, and IL-13) in the gingival crevicular fluid (GCF) of electronic cigarette users and non-smokers with moderate chronic periodontitis (CP). Methods: Electronic cigarette users and non-smokers with CP were included in the study. Full-mouth plaque and gingival indices, probing depth (PD), clinical attachment loss (CAL), and marginal bone loss (MBL) were assessed. The GCF was collected, and its volume and levels of IL-4, IL-9, IL-10, and IL-13 were assessed. These parameters were evaluated at baseline and 3 months after SRP. The sample size was estimated, and comparisons between groups were performed. P<0.05 was considered to indicate statistical significance. Results: Thirty-six electronic cigarette users (47.7±5.8 years old) and 35 non-smokers (46.5±3.4 years old) with CP were included. At baseline, there were no differences in plaque index (PI), PD, CAL, MBL, and GCF IL-4, IL-9, IL-10, and IL-13 between electronic cigarette users and nonsmokers. At the 3-month follow-up, there were no significant differences in PI, gingival index (GI), PD, CAL, and MBL in electronic cigarette users compared to baseline, while there were significant reductions in PI, GI, and PD among non-smokers. At the 3-month follow-up, GCF IL-4, IL-9, IL-10, and IL-13 levels were significantly elevated in both groups (P<0.05) compared to baseline. The increases in GCF IL-4, IL-9, IL-10, and IL-13 levels were significantly higher in non-smokers (P<0.05) than in electronic cigarette users at the 3-month follow-up. Conclusions: Levels of GCF IL-4, IL-9, IL-10, and IL-13 increased after SRP in electronic cigarette users and non-smokers with CP; however, the anti-inflammatory effect of SRP was more profound in non-smokers than in electronic cigarette users.

Enhancement of Tumor Response by MEK Inhibitor in Murine HCa-I Tumors (C3H/HeJ 마우스 간암에서 MEK 억제제에 의한 방사선 감수성 향상 효과)

  • Kim, Sung-Hee;Seong, Jin-Sil
    • Radiation Oncology Journal
    • /
    • v.21 no.3
    • /
    • pp.207-215
    • /
    • 2003
  • Purpose: Extracellular signal-regulated kinase (ERK), which is part of the mitogen-activated protin kinase cascade, opposes initiation of the apoptotic cell death which is programmed by diverse cytotoxic stimuli. In this regard, the inhibition of ERK may be useful in improving the therapeutic efficacy of established anticancer agents. Materials and Methods: Murine hepatocarcinoma, HCa-I is known to be highly radioresistant with a TCD50 (radiation dose yield in $50\%$ cure) of more than 80 Gy. Various anticancer drugs have been found to enhance the radioresponse of this particular tumor but none were successful. The objective of this study was to explore whether the selective inhibition of MEK could potentiate the antitumor efficacy of radiation in vivo, particularly in the case on radioresistant tumor. C3H/HeJ mice hearing $7.5\~8\;mm$ HCa-I, were treated with PD98059(intratumoral injection of $0.16\;\mug/50\;\mul$). Results: Downregulation on ERK by PD98059 was most prominent 1h after the treatment. In the tumor growth delay assay, the drug was found to Increase the effect of the tumor radioresponse with an enhancement factor (EF) of 1.6 and 1.87. Combined treatment of 25 Gy radiation with PD98059 significantly increased radiation induced apoptosis. The peak apoptotic index (number on apoptotic nuclei in 1000 nuclei X100) was $1.2\%$ in the case of radiation treatment alone, $0.9\%$ in the case of drug treatment alone and $4.9\%,\;5.3\%$ in the combination treatment group. An analysis of apoptosis regulating molecules with Western blotting showed upregulation of p53, p$p21^{WAF1/CIP1}\;and\;Bcl-X_s$ in the combination treatment group as compared to their levels in either the radiation alone or drug alone treatment groups. The level of other molecules such as $Bcl-X_L4, Bax and Bcl-2 were changed to a lesser extent. Conclusion: The selective inhibition of MEK in combination with radiation therapy may have potential benefit in cancer treatment.