• Title/Summary/Keyword: PCI

Search Result 487, Processing Time 0.03 seconds

Service Quality Improvement of Smart Phone Application (스마트 폰 애플리케이션 서비스 품질의 개선)

  • Yeom, Da-Hye;Kang, Chang-Wook
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.36 no.4
    • /
    • pp.38-44
    • /
    • 2013
  • Smart phones have brought rapid changes in this competitive world. Smart phone application developers are trying their best to consider the customer requirements in the most efficient way while considering all its attributes. However smart phone service quality has been given less consideration comparatively during the last few years. This paper proposes a measurement method for improving service quality of smart phone application. This method combines the service quality performance model (SQPM) and process capability index (PCI). The service quality performance model is used to identify service items that require improvement. Process capability index is used as a measure for prioritization of those improvements. Case study was carried out to search out important communication application service attributes. customer satisfaction level data was collected for users who used the application service. A total of twenty four service attributes were found during this survey. Using the joint approach of SQPM and PCI, five significant service attributes were prioritized for service quality improvement.

The Effect of Hand Massage on Discomfort in Patients Following Percutaneous Coronary Intervention (손마사지가 경피적관상동맥중재술 환자의 불편감에 미치는 효과)

  • Kim, Yeo-Jin;Chung, Seung-Hee;Suh, In-Sun
    • Korean Journal of Adult Nursing
    • /
    • v.20 no.3
    • /
    • pp.452-460
    • /
    • 2008
  • Purpose: This study assessed the effectiveness of hand massage on reducing discomfort of patients undergoing percutaneous coronary intervention(PCI). Methods: The sample consisted of 62 patients admitted to an university affiliated hospital. The 30 patients in experimental group received hand massage developed by Snyder(1995) for 5 minutes on both hands and 32 patients in control group received the usual nursing intervention only. The outcome variable of discomfort was measured 10 minutes before and after the hand massage using Questionnaire and VAS. The data were collected from Feb. 5th to May 17th in 2007, and analysed through Chi-square, and t-test with SPSS WIN 12.0. Results: The level of discomfort measured with the questionnaire was decreased in experimental group, but increased in control group. This discomfort changes in two groups were significantly different(t=4.43, p<.001). The level of discomfort measured with VAS was also decreased in experimental group, but increased in control group. The changes were significant, too(t=5.62, p<.001). Conclusion: It was clear that hand massage could be a useful nursing intervention in reducing the discomfort of patients undergoing PCI.

  • PDF

Bootstrapping Vector-valued Process Capability Indices

  • Cho, Joong-Jae;Park, Byoung-Sun
    • Communications for Statistical Applications and Methods
    • /
    • v.10 no.2
    • /
    • pp.399-422
    • /
    • 2003
  • In actual manufacturing industries, process capability analysis often entails characterizing or assessing processes or products based on more than one engineering specification or quality characteristic. Since these characteristics are related, it is a risky undertaking to represent variation of even a univariate characteristic by a single index. Therefore, the desirability of using vector-valued process capability index(PCI) arises quite naturally. In this paper, some vector-valued ${PCI}_p$ ${C}_p$=(${C}_{px}$, ${C}_{py}$),${C}_{pk}$=(${C}_{pkx}$, ${C}_{pky}$) and ${C}_{pm}$=(${C}_{pmx}$, ${C}_{pmy}$) considering univariate PCIs ${C}_p$,${C}_{pk}$ and ${C}_{pm}$ are studied. First, we propose some asymptotic confidence regions of our vector-valued PCIs with bootstrap. And we examine the performance of asymptotic confidence regions of our vector-valued PCIs ${C}_p$ and ${C}_{pk}$ under the assumption of bivariate normal distribution BN($\mu_{x}$, $\mu_{y}$, $\sigma_{x}^{2}$, $\sigma_{y}^{2}$, $\rho$) and bivariate chi-square distribution Bivariate $x^2$(5,5,$\rho$).

Design of Computer Hardware Fault Detector using ROM BIOS (ROM BIOS를 이용한 컴퓨터 하드웨어 장애인식 모듈 설계)

  • Nahm, Eui-Seok
    • Journal of the Korea Convergence Society
    • /
    • v.4 no.3
    • /
    • pp.21-26
    • /
    • 2013
  • Currently almost people use a personal computer for various purpose. But some people are not familiar to computer system. If they see only black screen on the monitor when they turn on the computer power, they can not recognize whether it is hardware or software faults. So, in this paper is aimed to develop the module of computer hardware fault detecter using ROM BIOS before OS booting. This module use PCI interface with mother board of computer. Before os booting, it can get the ROM BIOS memory by interrupt and show what hardware is fault according to the predefined memory content of BIOS.

The Detection of Yellow Sand Dust Using the Infrared Hybrid Algorithm

  • Kim, Jae-Hwan;Ha, Jong-Sung;Lee, Hyun-Jin
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.370-373
    • /
    • 2005
  • We have developed Hybrid algorithm for yellow sand detection. Hybrid algorithm is composed of three methods using infrared bands. The first method used the differential absorption in brightness temperature difference between $11\mu m\;and\;12\mu m$ (BID _1), through which help distinguish the yellow sand from various meteorological clouds. The second method uses the brightness temperature difference between $3.7\mu m\;and\;11\mu m$ (BID_2). The technique would be most sensitive to dust loading during the day when the BID _2 is enhanced by reflection of $3.7\mu m$ solar radiation. The third one is a newly developed algorithm from our research, the so-called surface temperature variation method (STY). We have applied the three methods to MODIS for derivation of the yellow sand dust and in conjunction with the Principle Component Analysis (PCA), a form of eigenvector statistical analysis. PCI shows better results for yellow sand detection in comparison with the results from individual method. The comparison between PCI and MODIS aerosols optical depth (AOD) shows remarkable good correlations during daytime and relatively good correlations over the land.

  • PDF

Guide wire fracture during percutaneous coronary intervention (경피적 관상동맥 확장 성형술 도중 우관상동맥 뒤가쪽가지에서 발생한 유도철사 부러짐)

  • Kim, Hak Ro;Yim, Tae Hoon;Kim, Byung Chul;Lee, Ho Jun;Oh, Hong Geun;Ju, Hyun Sik;Kim, Tae Jin;Kim, Young Bok
    • Journal of Yeungnam Medical Science
    • /
    • v.33 no.1
    • /
    • pp.52-55
    • /
    • 2016
  • Guide wire fracture during percutaneous coronary intervention (PCI) is rare. It can cause fatal complications such as thrombus formation, embolization, and perforation. Guide wire fracture could occur during intervention for severely calcified stenotic lesions, and rarely from distal small branches of stenotic lesions. There are several methods for its management depending on the material character, position, length of the remnant, and the patient's condition. If percutaneous retrieval was not achieved, the surgical procedure should be considered for prevention of potential risks, although the remnant guide wire does not usually cause complications. We experienced a patient with a guide wire fracture during PCI, and managed to prevent its complications through surgical removal of the remnant wire. We report this case here.

Surgical Removal of a IVUS Catheter that was Fractured During PCI (경피적 관상동맥 중재술 시 골절된 혈관 내 IVUS 카테터의 외과적 제거)

  • Kim, Young-Hak;Kim, Hyuck;Song, Young-Joo;Chung, Won-Sang;Kang, Jeong-Ho
    • Journal of Chest Surgery
    • /
    • v.41 no.6
    • /
    • pp.768-771
    • /
    • 2008
  • The use of IVUS provides information about the lumen and arterial wall, the location and extent of atherosclerotic plaque and the state of the arterial wall after PCi. The use of IVUS after insertion of an intracoronary stent has currently increased, while conflicting evidence exists concerning the long-term benefits of IVUS. We report here on a case of surgical removal of an entrapped and fractured IVUS catheter during insertion of intracoronary stents, and we include a review of the relevant literature.

Real-time MCG Signal Processing System (실시간 심자도 신호처리 시스템)

  • Chung, D.H.;Lim, J.S.;Kim, P.K.;Ko, K.H.;Lee, D.H.;Kim, H.J.;Ahn, C.B.
    • Proceedings of the KIEE Conference
    • /
    • 2004.07d
    • /
    • pp.2685-2686
    • /
    • 2004
  • 심자도(Magnetocardiography: MCG)는 심장에서 발생하는 자기신호로 크기가 수 pico Tesla에서 수 femto Tesla 정도로 지구 자기에 비하여 $10^{-6}{\sim}10^{-10}$ 정도로 매우 작기 때문에 보통 3층의 차폐 막 구조로 되어 있는 자기차폐실을 사용하여 외부 잡음을 줄인다. 그러나 자기차폐실의 비용이 크기 때문에, 자기차폐실의 비용을 줄이고 다양한 신호처리를 병행하여 신호대 잡음비를 높이고 있다. 본 논문에서는 1Giga FLOPS (FLoating point Operationals Per Second)의 부동 소숫점 연산능력을 가진 TMS320C6701을 사용하여 실시간 신호처리가 가능한 신호처리 시스템을 설계하였다. 개발된 DSP 보드는 PCI-bus 기반으로 설계하여 신호 측정 컴퓨터에 내장이 가능하도록 하였다. 프로그램과 데이터 처리를 위한 외부 메모리를 장착하였고, PCI 콘트롤러를 갖추어 PC 와의 대용량 메모리 공유가 가능하도록 하였다. 제작된 DSP 보드를 사용하여, 심자도 신호에서 실시간으로 적응 잡음 소거 및 필터링을 구현하여 신호대 잡음비의 향상을 확인할 수 있었다.

  • PDF

A Statistical Analysis Method for Image Processing Errors in the Position Alignment of BGA-type Semiconductor Packages (BGA형 반도체 패키지의 위치정렬용 영상처리기법 오차의 통계적 분석 방법)

  • Kim, Hak-Man;Seong, Sang Man;Kang, Kiho
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.19 no.11
    • /
    • pp.984-990
    • /
    • 2013
  • Pick and placement systems need high speeds and reliability for the position alignment process of semiconductor packages in picking up and placing them on placement trays. Image processing is usually adopted for position aligning where finding out the most suitable method is considered most important aspect of the process. This paper proposes a method for judging the performance of different image processing algorithms based on the PCI (Process Capability Index). The PCI is an index which represents the error distribution acquired from many experimental data. The bigger the index, the more reliable the results or the lower the deviation. Two compared and candidate methods are Hough Transform and PCA (Principal Component Analysis), both of which are very suitable for oblong or rectangular type packages such as BGA's. Comparing the two approaches through a CPI with enough experimental results leads to the conclusion that the PCA is much better than the Hough Transform in not only reliability, but also processing speed.

Design and Implementation for Image Monitoring System using Qt/Embedded (QT/임베디드 기반의 화상 감시시스템 설계 몇 구현)

  • 노방현
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.5 no.3
    • /
    • pp.236-240
    • /
    • 2004
  • We have implemented image monitoring system on PXA255 processor based embedded board that is ported QT/Embedded 2.3.7 version. User is able to monitor camera's capture image for widely separated host PC at client PXA255 board target board by ethernet communication method. And we designed PCI interface card that control motor for camera's Pan & Tilt. Bitmap format's images of $320\times{240}$ size are displayed on PXA255 board's TFT-LCD and User is able to monitor wanted position's image by touch screen input method.

  • PDF