• Title/Summary/Keyword: PCE(tetrachloroethylene)

Search Result 50, Processing Time 0.027 seconds

Development of Practical Advanced Oxidation Treatment System for Decontamination of Soil and Groundwater Contaminated with Chlorinated Solvent (TCE, PCE) : Phase I (염소계 화합물(TCE, PCE)로 오염된 토양 및 지하수 처리를 위한 실용적 고도산화처리시스템 개발 (I))

  • Sohn, Seok-Gyu;Lee, Jong-Yeol;Jung, Jae-Sung;Lee, Hong-Kyun;Kong, Sung-Ho
    • Journal of Soil and Groundwater Environment
    • /
    • v.12 no.5
    • /
    • pp.105-114
    • /
    • 2007
  • The most advanced oxidation processes (AOPs) are based on reactivity of strong and non-selective oxidants such as hydroxyl radical (${\cdot}OH$). Decomposition of typical DNAPL chlorinated compounds (TCE, PCE) using various advanced oxidation processes ($UV/Fe^{3+}$-chelating agent/$H_2O_2$ process, $UV/H_2O_2$ process) was approached to develop appropriate methods treating chlorinated compound (TCE, PCE) for further field application. $UV/H_2O_2$ oxidation system was most efficient for degrading TCE and PCE at neutral pH and the system could remove 99.92% of TCE after 150 min reaction time at pH 6($[H_2O_2]$ = 147 mM, UVdose = 17.4 kwh/L) and degrade 99.99% of PCE within 120 min ($[H_2O_2]$ = 29.4 mM, UVdose = 52.2 kwh/L). Whereas, $UV/Fe^{3+}$-chelating agent/$H_2O_2$ system removed TCE and PCE ca. > 90% (UVdose = 34.8 kwh/L, $[Fe^{3+}]$ = 0.1 mM, [Oxalate] = 0.6 mM, $[H_2O_2]$ = 147 mM) and 98% after 6hrs (UVdose = 17.4 kwh/L, $[Fe^{3+}]$ = 0.1 mM, [Oxalate] = 0.6 mM, $[H_2O_2]$ = 29.4 mM), respectively. We improved the reproduction system with addition of UV light to modified Fenton reaction by increasing reduction rate of $Fe^{3+}$ to $Fe^{2+}$. We expect that the system save the treatment time and improve the removal efficiencies. Moreover, we expect the activity of low molecular organic compounds such as acetate or oxalate be effective for maintaining pH condition as neutral. This oxidation system could be an economical, environmental friendly, and practical treatment process since the organic compounds and iron minerals exist in nature soil conditions.

A Study for Reductive Degradation and Surface Characteristics of Hexachloroethane by Iron Sulfide ($FeS,\;FeS_{2}$) (황화철($FeS,\;FeS_{2}$)을 이용한 헥사클로로에탄의 환원적 분해반응과 표면특성에 관한 연구)

  • Park Sang-Won;Kim Sung-Kuk;Heo Jae-Eun
    • Journal of Soil and Groundwater Environment
    • /
    • v.11 no.5
    • /
    • pp.35-42
    • /
    • 2006
  • The following results were obtained in the reductive degradation of hexachloroethane (HCA), and surface characteristics by using iron sulfide ($FeS,\;FeS_{2}$) mediators. HCA was degraded to pentachloroethane (PCA), tetrachloroethylene(PCE), trichloroethylene(TCE) and cis-l,2-dichloroethylene (cis-1,2-DCE) by complicated pathways such as hydrogenolysis, dehaloelimination and dehydrohalogenation. FeS had more rapid degradation rates of organic solvent than $FeS_{2}$. In liquidsolid reaction, the reaction rates of organic solvents were investigated to explain surface characteristics of FeS and $FeS_{2}$.. To determine surface characteristics of FeS and $FeS_{2}$, the specific surface area and surface potential of each mineral was determined and the hydrophilic site ($N_{s}$) was calculated. The specific surface area ($107.0470m^{2}/g\;and\;92.6374m^{2}/g$) and the $pH_{ZPC}$ of minerals ($FeS\;PH_{ZPC}=7.42,\;FeS_{2},\;PH_{ZPC}=7.80$) were measured. The results showed that the Ns of FeS and $FeS_{2}$ were $0.053\;site/mm^{2}\;and\;0.205\;site/mm^{2}$, respectively. $FeS_{2}$ had more hydrophilic surface than FeS. In other words, FeS have more hydrophobic surface site than $FeS_{2}$.

Removal of Chlorinated Organic Compounds Using Crosslinked PDMS Pervaporation Membrane (가교된 PDMS 투과증발 막을 이용한 유기 염소계 화합물의 제거)

  • Kim, Yong Woon;Hong, Yeon Ki;Hong, Won Hi
    • Clean Technology
    • /
    • v.7 no.3
    • /
    • pp.195-202
    • /
    • 2001
  • In this study the trace of chlorinated organic compound in aqueous solution was separated by pervaporation process using crosslinked PDMS (polydimethylsiloxane) membrane. The flux of trichloroethylene(TCE) increased linearly with feed composition but the flux of water was slightly increased. The partial flux of TCE was greater than that of tetrachloroethylene(PCE). The partial flux of TCE was not changed with operating temperature, but increased rapidly with feed flow rates. High crosslinking density causes the reduction of solubility and diffusivity for target component. The reduction of flux and selectivity for TCE is due to the chain immobilization and reduction of diffusivity with crosslinking density.

  • PDF

Establishment of Applicable Local Environmental Standards for Streams in Jeju Island (제주도 하천에 적용 가능한 지역환경기준 설정)

  • Cho, Eun-Il
    • Journal of Environmental Science International
    • /
    • v.24 no.1
    • /
    • pp.97-115
    • /
    • 2015
  • For the purpose of protecting the health of citizens and creating a delightful environment, the Government shall establish the environmental standards, and make such standards keep their propriety according to any changes in environmental conditions. The Special Metropolitan City, Metropolitan City or Do may, in case where deemed necessary in view of the speciality of regional environments, set forth the separate environmental standards which are more expanded and strengthened than the environmental standards by the Municipal Ordinance of the relevant City/Do. The purpose of this study was for the management of stream waters of Jeju Island and proposed the appropriate Jeju local river environmental standards. Jeju-Do and Daejeon-si applies the Local River Environmental Standards in Korea. While each nation? circumstances and environment are different, for the most part, environmental standards and purposes of use are similar to those in Korea. Proposed Jeju River Local Environment Standards followed The River Environment Standards of Nation(Korea) for Living Environment Standards. Newly Strengthened Value is Cd, Carbon tetrachloride, 1,2-dichloroethene, Tetrachloroethylene(PCE) and add Items is Fluorine, Selenium, Phenol and Toluene for Human Health Protection.

Removal Mechanisms of BTEX Compounds by RO/NF Membrane Processes (RO/NF막 공정을 이용한 BTEX 물질의 제어 특성 평가)

  • Jang, Hyuewon;Park, Chanhyuk;Hong, Seungkwan;Yoon, Yeomin;Jung, Jin-Young;Chung, Yun-Chul
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.5
    • /
    • pp.926-932
    • /
    • 2006
  • A series of bench-scale membrane filtration experiments were performed to systematically investigate the removal mechanisms of reverse osmosis (RO) and nanofiltration (NF) membranes for BTEX (benzene, toluene, ethylene, xylene), trichloroethylene (TCE) and tetrachloroethylene (PCE). The molecular weight of these organic compounds ranged from 78 to 166 dalton. The rejection of organic compounds by RO/NF membranes varied significantly from 59.6 to 99.2% depending on solute and membrane types. Specifically, experimental results demonstrated that the removal efficiency of RO/NF membranes increased as solute molecular characteristics such as W/L (molecular width/length) ${\times}$ $M_W$ (molecular weight) and octanol-water partition coefficient increased. This observation suggested that the rejection of small organic compounds by RO/NF membranes was determined by the combined effect of physical (molecular size and shape) and chemical (hydrophobicity) properties.

The Characteristics of Groundwaters in Taegu City (대구시 지하수의 수질특성)

  • Park Byung-Yoon;Cheon Kyung-Ah;Lee Dong-Hoon;Choi Choong-Ryeol;Choi Jyung;Kim Jin-Ho
    • Journal of Environmental Science International
    • /
    • v.8 no.6
    • /
    • pp.685-690
    • /
    • 1999
  • The pollution characteristics of groundwaters in Taegu City and correlation coefficients(r) between water pollution indicators were investigated for two years from January 1996 to December 1997. Volatile organic compounds such as TCE(tri-chloroethylene), PCE(tetrachloroethylene), l,l,l-trichloroethane, THM(trihalo-methane), dichloromethane, pesticides such as diazinon, parathion, malathion, and toxic inoganic matters such as As, Hg, Se, Pb, Cd, $Cr_6^+,$ CN were not detected in the groundwaters. Mean values of groundwater pollution indicators were below drinking-water standards, but hardness, $KMnO_4-C(potassium$ permanganate consumption), evaporate residues, $SO_4^{-2},\;Fe,\;NO_3^{-}-N,$ color and turbidity exceeded a little in some samples. As groundwater became deeper, hardness and evaporate residues remarkably increased, but $KMnO_4-C,\;NO_3^{-}-N,\;Cl-,$ color, turbity and bacteria decreased. $KMnO_4-C,$ evaporate residues, $Cl^-\;and\;SO_4^{-2}$ were very high at industrial and commercial areas, and $NO_3^--N$ and $NH_4^+-N$ were very high at agricultural and forest areas. It showed high positive significances in the relationships between hardness and each of evaporate residues, $SO_4^{-2}$, Zn and Mn, $KMnO_4-C$ and each of color, turbidity and Zn, color and each of turbidity, Cu, Zn and Mn, turbidity and each of Fe, Cu, Zn and Mn, and evaporate residues and each of $Cl^-,\;SO_4^{-2}$ and Zn.

  • PDF

The Result of Quality Control in POSCO's Industrial Hygiene Laboratory (사업장 자체측정기관 국내, 외 정도관리 참여 결과)

  • Lee, Young-Sei;Lee, Song-Kwon;Cho, Ki-Hyun;Chae, Chong-Hong;Kim, Yong-Lae
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.5 no.1
    • /
    • pp.87-103
    • /
    • 1995
  • Since being granted permission for self-assessment of the work environment by the Department of Labor in 1992, POSCO's Industrial Hygiene Laboratory has participated in domestic and Foreign Quality Control Programs 8 times and has obtained remarkable results. It has made a lot of effort to be a proficient laboratory with the ability to observe and analyse environmental monitoring data. The summary of results is as follows: 1. POSCO's Industrial Hygiene Laboratory has received a "P(Proficient)" grade from the round 115 to round 119 of AIHA/NIOSH PAT Program for analysis of such metals as lead, cadmium, zinc, and chromium, and also has received a "P(Proficient)" grade from its round 119 of for organic solvent analysis, i,e,. Trichloroethylene(TCE), Carbon Tetr-achloride(CTC), 1,2-Dichloroethane(DCE), 1,1,1-Trichloroethane(MCM), Tetrachloroethylene (PCE), Chloroform(CFM), Benzene(BNZ), toluene(TOL), and O-xylene(OXY). 2. In the Quality Control Evaluation Program performed by the Industrial Health Research Institute,Korea Industrial Safety Corporation, POSCO has passed impressively in the3-metal analysis test for lead, cadmium, cupper, and in the 6 organic solvent analysis test for Benzene(BNZ), toluene(TOL), O-xylene(OXY), Trichloroethylene(TCE) and Methyl isobutyl keton(MIBK), n-Hexane with 2 standard deviations. These analytic techniques should be practically applied to various fields, and reliable results of environmental monitoring should be considered to improve the work environment and to keep workers from occupation related diseases.

  • PDF

Study of Surfactant Enhanced Remediation Methods for Organic Pollutant(NAPL) Distributed over the Heterogeneous Medium (계면활성제를 이용한 불균질 매질에서 유기오염물(NAPL)의 정화효율에 관한 실험)

  • 서형기;이민희;정상용
    • Journal of Soil and Groundwater Environment
    • /
    • v.6 no.4
    • /
    • pp.51-59
    • /
    • 2001
  • Column and box tests were performed to investigate the removal efficiency of NAPL using the surfactant enhanced flushing In heterogeneous medium. Homogeneous Ottawa sand and heterogeneous soil were used to verify the increase of remediation efficiency for the surfactant enhanced flushing in column test. Box tests with two different heterogeneous sub-structure were performed to quantify the capability of the surfactant enhanced flushing as a remediation method to remove NAPL from the heterogeneous medium. Two different grain size sand layers were repeated in the box to simulate the heterogeneous layer formation and the modified fault structure was built to simulate the fault system in the box. O-xylene as a LNAPL and PCE as a DNAPL were used and oleamide as a non-ionic surfactant. The maximum NAPL effluent concentration with 1% oleamide flushing in the homogeneous column test increased about 460 times compared to that with only water flushing and about 250 times increased in the real soil column test. In heterogeneous medium, the maximum effluent concentration increased about 150 times in 1% oleamide flushing and most of NAPL were removed from the box within 8 pore volume flushing, suggesting that the removal efficiency increased very much compared to in only water flushing. Results investigated the capability of the surfactant enhanced remediation method to remove NAPL even in heterogeneous medium.

  • PDF

Performance of Institute of Occupational Health, Korean Industrial Health Association in Proficiency Analytical Testing Program (대한산업보건협회 산업보건연구소의 PAT 정도관리 참여결과)

  • Lee, Jun-Seong;Yoo, Ho-Kyum;Oh, Mi-Soon;Park, Wha-Me;Yun, Gi-Sang;Choi, Ho-Chun;Chung, Kyou-Chull
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.6 no.2
    • /
    • pp.313-321
    • /
    • 1996
  • Our laboratoy has been participated in Proficiency Analytical Testing (PAT) program which is operated by the Americal Industrial Hygiene Association in cooperation with the National Institute for Occupational Safety and Health (NIOSH). The program is designed to assist a laboratory improve its analytical performance by providing samples on a quarterly basis, evaluating the results, and providing reports on how well the laboratory performed. Evaluation of the results reported here covers five rounds of the PAT program (round 121~round 125). The way a laboratory is evaluated by PAT program is as follows: 1) There is no overall proficiency rating given to a laboratory. 2) A proficiency rating is given for each type of analyze (i.e., metals, silica, asbestos, solvents) that a laboratory analyzed. 3) Proficiency is rated acceptable ("A") if Z score lies between -3 and +3, and unacceptable if Z score is either higher than +3 ("H") or lower than -3 ("Lo"). Z score = (reported data - reference value) / standard deviation 4) For a laboratory to be rated proficient it must either have had no outliers over the most recent two rounds or of the samples actually analyzed over the past year (past four rounds), 75 % or more of the analyze sample results must be acceptable. According to the above rating criteria of PAT program, performance of metals including cadmium, lead, chromium and zinc, and asbestos sample analyses were rated acceptable ("A"). For silica analyses, all samples except one out of four samples in round 122 was rated high("H") were acceptable showing 95 % of ing 95 % of acceptance rate (19/20) throughout the rounds. Analyses of organic solvents were done on 52 samples in 9 types including methanol(MOH), 1,1,1-trichloroethane(MCM), tetrachloroethylene(PCE), trichloroethylene(TCE), benzene(BNZ), o-xylene(OXY), toluene(TOL), chloroform(CFM), 1,2-dichloroethane(DCE). All samples analyzed were rated acceptable except 2 samples that were rated high; one out of each four MCM and TCE samples in round 121, and one that was low out of four o-xylene analyses in round 122 indicating 94 % of acceptance rate(49/52) throughout the rounds. According to the laboratory rating criteria, our laboratory is rated proficient so far for all types of contaminants.

  • PDF

Characteristics of Groundwater Quality in Sasang Industrial Area, Busan Metropolitan City (부산시 사상공단지역의 지하수 수질 특성)

  • Hamm, Se-Yeong;Kim, Kwang-Sung;Lee, Jeong-Hwan;Cheong, Jae-Yeol;Sung, Ig-Hwan;Jang, Seong
    • Economic and Environmental Geology
    • /
    • v.39 no.6 s.181
    • /
    • pp.753-770
    • /
    • 2006
  • In urban areas, groundwater pollution is heavily affected by urbanization with land use types. This study aims to characterize groundwater quality and contamination in Sasang industrial area of Busan Metropolitan City where metalworking, machinery and footwear factories are located. Busan Metropolitan City is the highest in the utilization of groundwater resources among the metropolitan cities in Korea. $K^+,\;Na^+,\;Ca^{2+},\;Mg^{2+},\;Cl^-,\;SO_4^{2-}\;and\;HCO_3^-$ concentrations, and electrical conductivity (EC), total dissolved solids (TDS) and salinity are high in the areas near the Nakdong River. The results are attributed to the influence of salt water which intruded into the coastal sediments during sedimentation. In addition, the dominant chemical type of Ca-Cl indicates the influence of salt water in the geological formations as well as anthropogenic pollution. $SiO_2$ ion is interpreted to originate from both water-silicate mineral reactions and the decomposition of cement concretes. Trichloroethylene (TCE) was detected at 12 sites of total 18 sites. However, tetrachloroethylene (PCE) was detected at f sites and 1.1.1-trichloroethane (TCA) at 3 sites. According to the factor analysis, factor 1 was explained by 49.8%, factor 2 19.8%, and factor 3 11.0% with total 80.6% explanation. pH, TDS, salinity, $Ca^{2+},\;K^+,\;Mg^{2+},\;Na^+,\;Al^{3+},\;As^{3+},\;Cl^-\;and\;Fe^{2+}$ were positively highly loaded to factor 1. The chemical components loaded to factor 1 represent the chemical characteristics of both industrial pollution and influence by salt water. Based on the cluster analysis and distribution pattern of chemical components, the concentration of $Na^+,\;Ca^{2+},\;Cl^-,\;SO_4^{2-}\;K^+,\;and\;Mg^{2+}$ is high in the riverside area of the Nakdong River composed of coastal sediments that is influenced by salt water. The downstream area of the Hakjang Stream is judged to be affected by both salt water and artificial pollution. The other part of the study area is interpreted by anthropogenic pollution.