• Title/Summary/Keyword: PCA tube

Search Result 11, Processing Time 0.036 seconds

Analysis of Wall Blackening Reason in Ceramic Metal Halide Lamp by Shape of Arc-tube and Degradation Condition (방전관 형태 및 열화 조건에 따른 세라믹 메탈할라이드 램프의 흑화원인 분석)

  • Kim, Woo-Young;Lee, Se-Il;Yang, Jong-Kyung;Jeong, Young-Gi;Park, Dae-Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.12
    • /
    • pp.2262-2267
    • /
    • 2010
  • In order to analyze the reason of wall blackening, which affect the decline of lifetime in a ceramic metal halide lamp, we carried out the deterioration of ceramic tubes by a change in operating conditions with arc tubes of two types of spherical and cylindrical, and we have confirmed the cause of wall blackening through the analysis of element composition and spectrum from SEM/EDS and spectrum analyzer. Wall blackening of tungsten was shown by sputtering from ignition in 20 minute on/off condition and wall blackening from chemical reaction between PCA wall and rare earth halides was shown significantly in a condition without on/off test. Especially, the wall blackening and the decline of luminous flux were reduced by inner convection in spherical type arc tube. Moreover, the color temperature and color coordinate were changed by reduction of emission spectrum of Dy which causes the chemical reaction with PCA wall.

The Degradation Analysis of Arc-tube in Ceramic Metal-Halide Lamp (세라믹 메탈핼라이드 램프의 아크튜브 열화특성 분석)

  • Kim, Woo-Young;Yang, Jong-Kyung;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.03b
    • /
    • pp.18-18
    • /
    • 2010
  • 최근 PCA 아크튜브를 사용한 세라믹 메탈핼라이드 램프가 개발되어 기존의 석영관 메탈핼라이드 램프의 사용 범위를 넘어 다양하게 활용되고 있다. 이에 따라 램프의 신뢰성 또한 중요한 요소로 여겨지게 됨으로 본 논문에서는 세라믹 메달핼라이드 램프의 아크튜브의 열화특성을 확인하기기 위해 램프를 가속열화 시켜 구조적 변화를 확인하였다. 이 결과 모세 관 내 Moly winding과 세라믹 아크튜브의 열팽창계수 차이로 인해 간격이 멀어지고 그 사이로 원소들이 침입하였고 이로 인해 아크튜브와 전극의 열화를 촉진하며 전극의 틀어짐을 유발하였다. 또 내부에 봉입된 희토류 금속 요오드화물이 고온에서 PCA 관벽과 반응을 일으켜 아크튜브를 부식시킴을 확인할 수 있었다.

  • PDF

Analysis of Degradation Phenomena in Arc-Tube of Ceramic Metal Halide Lamp (세라믹 메탈할라이드 램프의 아크튜브 열화현상 분석)

  • Kim, Woo-Young;Lee, Se-Il;Yang, Jong-Kyung;Jang, Hyeok-Jin;Park, Dae-Hee
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.12
    • /
    • pp.996-1001
    • /
    • 2010
  • Recently, the demand of ceramic metal halide lamp has been expanded. Therefore, the lamp with high efficiency and long lifetime are increasing and the evaluation of reliability is needed. In this paper, the degradation phenomena of ceramic metal halide lamp was studied. The lamp was tested for 3000 on/off cycles with each cycle having a duration of 20 minutes on and 20 minutes off based on the accelerated aging experiment based on "Reliability Standards RS C 0085". As result, the corrosion of arc tube and leak was appeared from reaction between inner wall of PCA and chemical elements, and distortion of electrode was resulted from difference of thermal expansion between arc tube of PCA and electrode. Also, the efficiency of lamp was decreased by the change of inner pressure, operation temperature, and driving voltage from wall blackening.

Optical Properties with Arc Tube Structure of Ceramic Metal-Halide Lamps (세라믹 메탈할라이드 램프의 아크튜브 구조에 따른 광학적 특성)

  • Kim, Woo-Young;Jang, Hyeok-Jin;Yang, Jong-Kyung;Park, Hyung-Jun;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.378-379
    • /
    • 2009
  • High intensity metal halide discharge lamp performance, specifically the generated luminous flux and light color content, depends critically on the arc tube design. Factors influencing the design and consequent lamp efficacy include : lamp size, geometry, arc tube composition, fill chemistry, electrode design and excitation modes. Shaping of Polycrystalline Alumina(PCA) can be realized by conventional ceramic processes. Several processes are applied nowadays. Well-known in the ceramic high pressure field for decades are the pressing and the extrusion method. Newly developed slurry and precious forming technologies give the one-body seamless tubes, which improve thickness uniformity and lighting performance. Now, we reported some optical properties with different arc tube structures of ceramic metal halide lamps.

  • PDF

Optical Properties with Arc Tube Structure of Ceramic Metal Halide lamps (세라믹 메탈할라이드 램프 아크튜브 구조에 따른 광학적 특성)

  • Lee, Joo-Hoo;Yang, Jong-Kyung;Kim, Nam-Goon;Jang, Hyeok-Jin;Park, Dae-Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.12
    • /
    • pp.2244-2248
    • /
    • 2008
  • High intensity metal halide discharge lamp performance, specifically the generated luminous flux and light color content, depends critically on the arc tube design. Factors influencing the design and consequent lamp efficacy include : lamp size, geometry, arc tube composition, fill chemistry, electrode design and excitation modes. Shaping of Polycrystalline Alumina(PCA) can be realized by conventional ceramic processes. Several processes are applied nowadays. Well-known in the ceramic high pressure field for decades are the pressing and the extrusion method. Newly developed slurry and precious forming technologies give the one-body seamless tubes, which improve thickness uniformity and lighting performance. Now, we reported some optical properties with different arc tube structures of ceramic metal halide lamps.

Ion Pair Extraction of Aliphatic Amines and Quaternary Ammonium Salts by Picric Acid (Picric Acid에 의한 지방족 아민류와 4급 암모늄 염류의 이온쌍 추출)

  • 김박광;이종숙;장성기;나운용;옥치환
    • YAKHAK HOEJI
    • /
    • v.35 no.3
    • /
    • pp.182-189
    • /
    • 1991
  • Systematic study on the extraction of ion pair by the use of picric acid (PCA) as an ion pair forming reagent to the aliphatic amines has not be done by spectrophotometric method. The extraction of ion pair by the use of PCA and 23 kinds of the aliphatic amines was examined. The procedure is as follows; Elving's buffer solution (pH 1.3~10, ionic strength 0.5) each amine solution, and PCA solution were taken into a test tube. The mixture was shaken mechanically with chlorform. The organic phase was filtered through a filter paper to remove water droplets. The absorbance was examined at $\lambda_{max}$ against a reagent blank. Primary and secondary whose carbon number were more than 7 or 6, respectively, are extractable as ion pairs with PCA, while tertiary amines and quaternary ammonium salts are also extractable without the correlation of carbon number. It was considered that the ion pair extraction of primary and secondary amines was affected by the number of carbon of amines, but its extraction of tertiary amines or quaternary ammonium salts was affected by kind of aliphatic amines rather than pKa values or carbon number of amines.

  • PDF

Development of the Flow Control Regulator for Patient Controlled Analgesia (환자통증조절장치(PCA)의 유량제어조절기 개발)

  • Kim, S.Y.;Song, S.J.;Seo, H.B.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.7 no.4
    • /
    • pp.39-43
    • /
    • 2010
  • The flow regulators we widely use have some disadvantages. They have a constant flow within each regulator and an inaccuracy with extruding capillary. In this study, we have developed a new type of regulator which was made up of two different capillary tubes overlapped each other. The developed regulator can vary and control the amount of flow. The design parameters of the developed regulator are obtained by using the analytical software. We have proved that the developed regulator can control flow properly through making a trial product and experiment.

  • PDF

Classification of NOVCs and AVOCS for Healing Substance Measurement System Based on Gas Sensors Array in Forest Environment (가스센서 어레이를 이용한 산림환경 내 치유물질 측정시스템을 통한 자연적 휘발성 유기화합물(NVOCs)과 인위적 휘발성 유기화합물(AVOCs) 분류)

  • Joon-Boo Yu;Hyung-Gi Byun
    • Journal of Sensor Science and Technology
    • /
    • v.32 no.2
    • /
    • pp.95-99
    • /
    • 2023
  • Forest healing is an activity that enhances immunity and human health using various elements of nature, such as fragrance and scenery. Particularly, phytoncide composed of terpene, a natural volatile substance emitted by forest plants, activates the immune function and is an important raw material in health-related products, such as antibacterial and insect repellents. Moreover, phytoncide is used as a measure to evaluate the impact of the forest atmosphere on the human body. This study aims to implement a highly sensitive gas sensor system that can measure phytoncide in real-time, which is an essential element for realizing a forest healing environment. A gas generation apparatus was implemented by using an adsorption tube in consideration of filed applicability in a laboratory atmosphere to enable the measurement of α-pinene and limonene, which are among the main components of phytoncide. Throughout the experimental trials, the sensitivity of gas sensor arrays to α-pinene and limonene was confirmed. In addition, the classification results demonstrated the AVOCs and NVOCs can be well discriminated using PCA. The primary results confirmed the possibility of developing a high-sensitivity gas sensor system for phytoncide sensing in real time.

Acoustic, Intraoral Air Pressure and EMG Studies of Vowel Devoicing in Korean

  • Kim, Hyun-Gi;Niimi, Sei-Ji
    • Speech Sciences
    • /
    • v.10 no.1
    • /
    • pp.3-13
    • /
    • 2003
  • The devoicing vowel is a phonological process whose contrast in sonority is lost or reduces in a particular phonetic environment. Phonetically, the vocal fold vibration originates from the abduction/adduction of the glottis in relation to supraglottal articulatory movements. The purpose of this study is to investigate Korean vowel devoicing by means of experimental instruments. The interrelated laryngeal adjustments and aerodynamic effects for this voicing can clarify the redundant articulatory gestures relevant to the distinctive feature of sonority. Five test words were selected, being composed of the high vowel /i/, between the fricative and strong aspirated or lenis affricated consonants. The subjects uttered the test words successively at a normal or at a faster speed. The EMG, the sensing tube Gaeltec S7b and the High-Speech Analysis system and MSL II were used in these studies. Acoustically, three different types of speech waveforms and spectrograms were classified, based on the voicing variation. The intraoral air pressure curves showed differences, depending on the voicing variations. The activity patterns of the PCA and the CT for devoicing vowels appeared differently from those showing the partially devoicing vowels and the voicing vowels.

  • PDF

Study of Laryngeal Evoked Electromyography Method in Rats (백서를 이용한 후두 유발 근전도 검사 방법에 대한 연구)

  • 조선희;이재연;민선식;신유리;정성민
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.11 no.2
    • /
    • pp.178-184
    • /
    • 2000
  • Laryngeal evoked EMG is the objective and quantitative method to measure the innervation of laryngeal muscle. If there is a mobility disorder of vocal cords, the cause and location of neural lesion co be understood by the laryngeal evoked EMG and if there is a vocal cord paralysis, the degree of recovery and the policy of treatment can be determined by it. Recently, the studies of reinnervation after recurrent laryngeal nerve injury have been actively carried out. Laryngeal evoked EMC is useful to these studies. The aim of study is to know whether noninvasive methods for stimulating the recurrent laryngeal nerve and for recording of compound action potential(CAP) using surface electrode are as useful as the invasive method using needle electrode. We obtained EMG of laryngeal muscle by various stimulating and recording methods : 1) Direct nerve stimulation by placing nerve cuff electrode made out of silastic tube and platinum wire and recording by insertion of hook wire electrode into posterior cricoarytenoid(PCA) and thyroarytenoid(TA) muscles, respectively. 2) Recording of compound action potential by surface electrode after stimulation of recurrent laryngeal nerve by the insertion of 27 gauge of needle electrode. 3) Recording of compound action potential by surface electrode after stimulating the recurrent laryngeal nerve by transcutaneous blunt rod electrode at tracheoesophageal groove. The amplitude, duration and latency of the CAP evoked by recurrent laryngeal nerve stimulation were compared among the three groups. The amplitude of CAP was smallest in the group recorded from posterior cricoarytenoid and hyroarytenoid muscle, and that recorded by surface electrode after stimulation by needle electrode was largest. The difference in amplitude between the group by hook wire recording and the two groups by surface electrode recording was significant statistically. There is no significant difference in duration and latency among three groups. Since the waveform of CAP from all three methods has similar duration, latency, we concluded that noninvasive method is a useful as invasive methods.

  • PDF