• Title/Summary/Keyword: PC Laboratory Service

Search Result 16, Processing Time 0.021 seconds

Development of 3-axial Realization Algorithm of Road Profile for Multi-axial Road Simulator (다축 로드 시뮬레이터의 3축 재현 알고리즘 개발)

  • 류신호;정상화;김종태
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.962-965
    • /
    • 2002
  • Full scale durability test in the laboratory is an essential of any fatigue life evaluation of components or structures of the automotive vehicle. Component testing is particularly important in today's highly competitive industries where the design to reduce weight and production costs must be balanced with the necessity to avoid expensive service failure. Generally, Hydraulic road simulator is used to carry out the fatigue test and the vibration test. In this paper, the algorithm and software to realize the real road profile are developed. The operation software for simultaneously controlled multi-axial simulator is developed and the input and output data are displayed window based PC controller in real time. The software to generate the real road profile are developed. This paper developed a road profile reappearance software and simultaneously apply 3-axial actuator to white noise, so we verified the propriety of reappearance software through accomplishes an real test.

  • PDF

A Study on Operational Software Development and Calibration of Multi-Axis Vibration Testing Device (다축 제어용 가진기의 구동소프트웨어 개발 및 보정에 관한 연구)

  • 정상화;김재열;류신호
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.9 no.2
    • /
    • pp.143-151
    • /
    • 2001
  • In the recent day, fatigue life prediction techniques play a major role in the design of components in the ground vehicle industry. Full scale durability testing in the laboratory is an essential of any fatigue life evaluation of components or structure of the automotive vehicle. Component testing is particularly important in todey's highly competitive industries where the design to reduce weight and production costs must be balanced with the necessity to avoid expensive service failure. Generally, Multi-axis durability testing device is used to carry out the fatigue test. In this paper, The operation software for simultaneously driving Multi-axis vibration testing device is developed and the input and output data are displayed in windows of PC controller with real time. Moteover the characteristics of the displacement and the load of Multi-axis actuators are calibrated separately.

  • PDF

Subhective Symptoms and Work-related Health Risk Factors in Korean Dental Laboratory Technicians (우리 나라 치과 기공사의 신체 자각 증상과 직업 관련 건강 위험 요인)

  • Kim, Woong-Chul;Lee, Se-Hoon
    • Journal of Technologic Dentistry
    • /
    • v.22 no.1
    • /
    • pp.89-112
    • /
    • 2000
  • Although dental laboratory technicians are prone to be exposed to various work-related health hazardous materials such as dusts, chemicals, etc., the prevalence and nature of work-related health problems of them have not been a matter of great concern in the field of occupational health service in Korea. The purpose of the present investigation was to describe a collected profile of subjective health symptoms and their attributable factors in Korean dental laboratory technicians. A questionnaire listing five groups of health symptoms and five health symptom-related factors was mailed to randomly selected 1,900 dental laboratory technicians. Among them, 1,344 dental laboratory technicians filled out the questionnaires and returnde them. Five groups of health symptoms included musculoskeletal symptom, dermal symptoms, respiratory symptoms, eys symptoms, and ear symptoms. Five health symptom-related factors were occupational environment-related health risk factors, work history, health related habits and status, use of personal protective equipment and general characteristics. Detailed parameters of health risk factors were work posture, vibration, and chemical or physical hazards such as dust, fume, vapor, solvent, light, and noise for occupational environment-related factors; work place, area, number of employees, work hours, career, work part, and work load for work history; Broca's index, hours of sleep, eating, smoking, alcohol, exercise, health examination, and self assessed health status for health habits and status; face masks, goggles, and so on for use of personal protective equipment, and; age, sex, marital status, and education for general characteristics. Before the start of main survey, a pilot survey was carried out for validity and reliability tests of the questionnaire. All the data obtained were coded and analyzed with PC/SAS 6.12 program. The prevalence of health symptoms was the highest in musculoskelton (87.3%), and followde by eyes (78.9%), respiratory organs (64.3%), ears (57.8%), and skin (52.2%) in descending order. Statistically significant risk factors by multiple logistic regression analyses were sex, health examination, self assessed health status, and hand/finger posture in musculoskeletal symptoms; sex, self assessed health status, career, acid gas, and hand contact with resin mixture in deraml symptoms; Broka's smoking, exercise, self assessed health status, and face mask in respiratory symptoms; sex, hours of sleep, self assessed health status, work hours, work load, plaster dust, inadequate lighting, and goggle in eys symptoms, and eating, smoking, self assessed health status, and work load in ear symptoms. With the above considerations in mind, prevalence of subjective symptoms among Korean dental laboratory technicians was relatively high, and they were attributable to most of the occupational environment-related factors, work history, use of personal protective equipment, health habits and status, and general characteristics. Particularly, it is suggested that health promotion programs for promoting self- assessed health status and smoking cessation, preventive measures for protection of the female technicians’health, and reducing work load be necessary, since those factors were associated with more than one subjective symptom.

  • PDF

Realization Software Development of Road Profile for Multi-axial Road Simulator (다축 로드 시뮬레이터의 노면 프로파일 재현 소프트웨어 개발)

  • 정상화;류신호;김우영;양성모;김택현
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.5
    • /
    • pp.190-198
    • /
    • 2002
  • Full scale durability test in the laboratory is an essential of any fatigue life evaluation of components or structures of the automotive vehicle. Component testing is particularly important in today's highly competitive industries where the design to reduce weight and production costs must be balanced with the necessity to avoid expensive service failure. Generally, hydraulic road simulator is used to carry out the fatigue test and the vibration test. In this paper, the algorithm and software to realize the real road profile are developed. The operation software for simultaneously controlled multi-axial road simulator is developed and the input and output data are displayed window based PC controller in the real time. Futhermore, the software to generate the real road profile are developed. The validity of the software are verified by applying the belgian road, the city road, the highway, and the gravel road. The results of the above experiment show that the real road profiles are realized well after 10th iteration.

Isolation of the Pathogenic Bacteria from Chicken and Antimicrobial Drug Sensitivity of the Strain Isolated (가금유래 주요병원성세균의 분리와 분리균주에 대한 약제감수성조사)

  • 박근식;김기석;남궁선
    • Korean Journal of Poultry Science
    • /
    • v.7 no.1
    • /
    • pp.53-64
    • /
    • 1980
  • A total of 1503 specimens were submitted to the Poultry Disease Diagnostic Service Laboratory during the year 1966 and 1978. The most frequently diagnosed diseases in order of prevalence were avian mycoplasmosis, staphylococcosis, colibacillosis, salmonellosis and pullorum disease, the percentages of the conditions being 24.6%, 20.0%, 18.0%, 12.6% and 6.4%, respectively, The drug resistance of pathogenic mirnoorganisms isolated during the year 1978 from chicken with colicabacillosis, staphylococcosis or salmonellosis were investigated by the use of disc diffusion technique, the results being as follow. 1) Drug resistance of 63 strains of Escherichia coli More than 95% of the strains tested were sensitive to colistin and gentamicin. The percentages of strains sensitive to kanamycin, chloramphenicol, ampicillin and nitrofurantoin were 66.7%, 60.3%, 60.3% and 47.6%, respectively. Majority of the strains were highly resistant to streptomycin and tetracyline. All the strains were resisistant to bacitracin lincomycin, oleandomycin, penicillin and erythromycin. All the strains tested were resistant to more than two among 10 drugs in common use such as penicillin, erythromycin, streptomycin, tetracycline, neomycin, chloramphenicol, kanamycin, ampicillin and gentamicin, and 27 different resistance patterns were noted. The most frequent multiple resistance pattern was PC, EM, SM and TC (11.1%). 2) Drug resistance of 48 strains of Salmonella More than 95% of the strains tested were sensitive to colistin, gentamicin ana ampicillin. The percentages of st rains sensitive to kanamycin, tetracycline, neomycin and nitrofurantoin were 81,3%, 79%, 72.9%, and 68.0% respectively. None of them was sensitive to streptomycin, oleandomycin, erythromycin, lincomycin and bacitracin. All the strains were resistant to more than one among 7 drugs in common use such as streptomycin, erythromycin, neomycin, tetracycline, kanamycin, ampicillin and gentamicin. The most frequent resistance pattern was SM and EM(66.7%). 3) Drug resistance of 54 strains of Staphylococci All the strains tested were sensitive to gentmaicin, kanamycin and cephalothin. Majority of them were highly sensitive to bacitracin, methicillin, nitrofurantoin and chloramphenicol. The Percentages of strains sensitive to streptomycin, ampicillin, lincomycin and tetracycline were 66.7%, 55.6%, 44.4% and 27.8%, respectively. Among them, 51 strains were resistant to more than one among 11 drugs in common use such as tetracycline, lincomycin, ampicillin, penicillin, streptomycin, erythromycin, neomycin, oleandomycin, chloramphenicol, methicillin and bacitracin, and thirty one different resistance patterns were noted.

  • PDF

A Feasibility Study on the Infrastructure Project of PCB Industrial Technology (PCB 산업기술 기반구축 사업의 타당성 분석 연구)

  • Kim, Dae Ho
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.8 no.4
    • /
    • pp.57-66
    • /
    • 2013
  • Domestic PCB industry formed by orders of demand companies is extremely vulnerable in its innovation infrastructure including high value-added technology development and information exchange. The majority of PCB products produced in the country relies on the imports from abroad and it causes its vulnerability to external market changes. Due to the negative perceptions about the industry (e.g., 3D job), low treatment (especially SMEs) and expertise employment avoidance in PCB industry, the job market conditions of PCB industry is not so good. In these circumstances, the PCB industry is completely dependent on the demand market such as cellular phones, and tablet PC, and as a result the responsiveness of PCB industry to the changes in demand market is also vulnerable. In this PCB industry, Korean government is trying to build the research infrastructure for PCB industry that realizes the sharing of information among companiesthrough the operation of the PCB industry innovation forum (information innovation), builds SME suppot platform and supports quality improvement (technology innovation), and supports enterprise collaboration processes (material-process-equipment) utilizing PCM open laboratory. The PCB industry technology infratstructure project is going to be promoted by the government(1.3 billion won, each year) and the private investmen(434 million won each year) from 2013 to 2017(5 years project)(table 1). This study analyzes the feasibility of the project, by using the AHP analysis and the results shows that this project is considered feasible because the AHP overall score is evaluated as 0.841, the overall score is greater than or equal to 0.55.

  • PDF