• Title/Summary/Keyword: PC 빔

Search Result 42, Processing Time 0.027 seconds

Technology of Non-destructive Stress Measurement in Spot Welded Joint using ESPI Method (ESPI법에 의한 스폿 용접부의 비파괴적 응력측정 기술)

  • 김덕중;국정한;오세용;김봉중;유원일;김영호
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.1 no.1
    • /
    • pp.23-26
    • /
    • 2000
  • In spot welded joint. Electronic Speckle Pattern Interferometry(ESPI) method using the Model 95 Ar laser a video system and an image processor was applied to measure the stress Unlike traditional strain gauges or Moire method, ESPI method has no special surface preparation or attachments and can be measured in-plane displacement with non-contact and real time. In this experiment, specimens are loaded in parallel with a load cell. The specimens are made of the cold rolled steel sheet with 1mm thickness, are attached strain. gauges. This study Provides an example of how ESPI has been used to measure stress and strain inspecimen. The results measured by ESPI are compared with the data which was measured by strain gauge method under tensile testing.

  • PDF

A Study of a Non-commercial 3D Planning System, Plunc for Clinical Applicability (비 상업용 3차원 치료계획시스템인 Plunc의 임상적용 가능성에 대한 연구)

  • Cho, Byung-Chul;Oh, Do-Hoon;Bae, Hoon-Sik
    • Radiation Oncology Journal
    • /
    • v.16 no.1
    • /
    • pp.71-79
    • /
    • 1998
  • Purpose : The objective of this study is to introduce our installation of a non-commercial 3D Planning system, Plunc and confirm it's clinical applicability in various treatment situations. Materials and Methods : We obtained source codes of Plunc, offered by University of North Carolina and installed them on a Pentium Pro 200MHz (128MB RAM, Millenium VGA) with Linux operating system. To examine accuracy of dose distributions calculated by Plunc, we input beam data of 6MV Photon of our linear accelerator(Siemens MXE 6740) including tissue-maximum ratio, scatter-maximum ratio, attenuation coefficients and shapes of wedge filters. After then, we compared values of dose distributions(Percent depth dose; PDD, dose profiles with and without wedge filters, oblique incident beam, and dose distributions under air-gap) calculated by Plunc with measured values. Results : Plunc operated in almost real time except spending about 10 seconds in full volume dose distribution and dose-volume histogram(DVH) on the PC described above. As compared with measurements for irradiations of 90-cm 550 and 10-cm depth isocenter, the PDD curves calculated by Plunc did not exceed $1\%$ of inaccuracies except buildup region. For dose profiles with and without wedge filter, the calculated ones are accurate within $2\%$ except low-dose region outside irradiations where Plunc showed $5\%$ of dose reduction. For the oblique incident beam, it showed a good agreement except low dose region below $30\%$ of isocenter dose. In the case of dose distribution under air-gap, there was $5\%$ errors of the central-axis dose. Conclusion : By comparing photon dose calculations using the Plunc with measurements, we confirmed that Plunc showed acceptable accuracies about $2-5\%$ in typical treatment situations which was comparable to commercial planning systems using correction-based a1gorithms. Plunc does not have a function for electron beam planning up to the present. However, it is possible to implement electron dose calculation modules or more accurate photon dose calculation into the Plunc system. Plunc is shown to be useful to clear many limitations of 2D planning systems in clinics where a commercial 3D planning system is not available.

  • PDF

A Study on Constitution of Plant Safety Inspection System for Measuring Joint Axial Force of High Tension Bolt (고장력 볼트의 체결축력 측정을 위한 설비 안전 검사 시스템 구축에 관한 연구)

  • Kim, J.Y.;Park, S.G.;Kim, H.S.;Kim, C.H.;You, S.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.15 no.2
    • /
    • pp.371-377
    • /
    • 1995
  • By using ultrasonic waves, we obtained conclusion from the experiment for measuring joint axial force of high tension bolt. The conclusion is followed. : From the high tension bolts used at turbine of Thermoelectric Power Plant, we obtained the equation of calculating joint axial force that is ${\sigma}=\frac{{\Delta}BPD}{j{\times}{\Sigma}{\delta}}$. By using IBM PC, which is inputed by the equation for calculating joint axial force of high tension bolts, we got joint axial force of high tension bolts form beam path of ultrasonic waves. Furrther, we can identify that constitution of plant safety inspection system is possible.

  • PDF

Hydrophilic surface formation of polumer treated by ion assisted reaction and its applications (이온빔보조 반응법을 이용한 고분자 표면의 친수성처리와 그 응용)

  • Cho, J.;Choi, S. C.;Yun, K.H.;Koh, S. K.
    • Journal of the Korean Vacuum Society
    • /
    • v.8 no.3B
    • /
    • pp.262-268
    • /
    • 1999
  • Polycarbonate (PC) and Polymethylmethacrylate (PMMA) surface was modified by ion assisted reaction (IAR) technique to obtain the hydrophilic functional groups and improve the wettability. In conditions of ion assisted reaction, ion beam energy was changed from 500 to 1500eV, and ion dose and oxygen gas blown rate were fixed $1\times10^{16}$ ions/$\textrm{cm}^2$ and 4ml/min, respectively. Wetting angle of water on PC and PMMA surface modified by $Ar^+$ ion without blowing oxygen at 4ml/mon showed $5^{\circ}$ and $10^{\circ}$. Changes of wetting angle with oxygen gas and $Ar^+$ ion irradiation were explained by considering formation of hydrophilic group due to a reaction between irradiated polymer chain by energetic ion irradiation and blown oxygen gas. X-ray photoelectron spectroscopy analysis shows that hydrophilic groups such as -C-O, -(C=O)- and -(C=O)-O- are formed on the surface of polymer by chemical interaction. The polymer surface modification using ion assisted reaction only changed the surface physical properties and sept the bulk properties. In comparison with other modification methods, the surface modification by IAR treatment was chemically stable and enhanced the adhesion between metal and polymer surface. The applications of various kinds of polymer surface modification methods, metal and polymer surface. The applications of various kinds of polymer surface modification could be appled to the new materials about hydrophilic surface properties by IAR treatment. The adhesion between metal film and polymer measured by Scotch tape test whether the hydrophilic surfaces could improve the adhesion strength or not.

  • PDF

Measurement of Micro-displacement of an Object by Laser Speckle using Linear Array CCD Detection System (레이저 스펙클과 1차원 CCD소자를 이용한 물체의 미소변위측정에 관한 연구)

  • 우창헌;민동현;김수용
    • Korean Journal of Optics and Photonics
    • /
    • v.5 no.1
    • /
    • pp.138-143
    • /
    • 1994
  • A speckle correlation method was applied to measure the in-plane translation of a diffuse object which has rough surface using a linear CCD sensor and personal computer. Displacement of a speckle pattern produced from the object illuminated by a laser beam was measured by the cross-correlation functions between the I-D speckle profiles before and after the object translation, which were measured by linear CCD array sensor to be sent to IBM 386 personal computer. The sensitivity of the measurement was dependent on the radius of the wavefront curvature of incident beam as well as the spatial resolution of linear CCD array. A linear CCD array had 15 Jlffi pitch and 1728 pixels. The ratio of the speckle displacement and object translation varied from 1.03 to 5.20. The object translation of $3\mu\textrm{m}$ can be measured br the linear CCD sensor of which pitch was $15\mu\textrm{m}$, when the ratio of the speckle displacement and object translation was 5.20.s 5.20.

  • PDF

Development of portable single-beam acoustic tweezers for biomedical applications (생체응용을 위한 휴대용 단일빔 음향집게시스템 개발)

  • Lee, Junsu;Park, Yeon-Seong;Kim, Mi-Ji;Yoon, Changhan
    • The Journal of the Acoustical Society of Korea
    • /
    • v.39 no.5
    • /
    • pp.435-440
    • /
    • 2020
  • Single-beam acoustic tweezers that are capable of manipulating micron-size particles in a non-contact manner have been used in many biological and biomedical applications. Current single-beam acoustic tweezer systems developed for in vitro experiments consist of a function generator and a power amplifier, thus the system is bulky and expensive. This configuration would not be suitable for in vivo and clinical applications. Thus, in this paper, we present a portable single-beam acoustic tweezer system and its performances of trapping and manipulating micron-size objects. The developed system consists of an Field Programmable Gate Array (FPGA) chip and two pulsers, and parameters such as center frequency and pulse duration were controlled by a Personal Computer (PC) via a USB (Universal Serial Bus) interface in real-time. It was shown that the system was capable of generating the transmitting pulse up to 20 MHz, and producing sufficient intensity to trap microparticles and cells. The performance of the system was evaluated by trapping and manipulating 40 ㎛ and 90 ㎛ in diameter polystyrene particles.

A Study on Implementation of NAS-based K-12 Learning Management System for Supporting Developing Countries (개발도상국 지원을 위한 NAS기반의 K-12 학습관리 시스템 구현 방안에 대한 연구)

  • No, In-Ho;Yoo, Gab-Sang;Kim, Hyeock-Jin
    • Journal of Digital Convergence
    • /
    • v.17 no.1
    • /
    • pp.179-187
    • /
    • 2019
  • Developing countries, including Africa, are experiencing very little human resources development due to the deprivation of equal educational opportunities, poor educational conditions, and the gap in information technology with developed countries. Developing countries that do not have excellent human resources are lagging behind in globalization competition with developed countries, and the problem of 'human resource development' in developing countries can not be avoided. In developing countries, education budgets are too low to meet education needs and compulsory education, and therefore they are not adequately responding to the increasing demand for education. The lack of education budget is due to the lack of education infrastructure. In this study, the NAS based server is configured to configure functions such as educational content and learning management, and the client area is presented with solutions for various media such as tablet, PC, and beam projector. And to support optimized e-learning services in developing countries by constructing a SCORM-based platform.

Study on the Vacuum System of the KCCH-50MeV Cyclotron (KCCH-50 MeV 싸이클로트론의 진공계통에 관한 연구)

  • Park, Joo-Shik;Chai, Jong-Seo;Yoo, Seong-Yul
    • Journal of Radiation Protection and Research
    • /
    • v.11 no.2
    • /
    • pp.146-151
    • /
    • 1986
  • In this paper, general features and measured results of vacuum pressure on the vacuum system of 50 MeV proton KCCH-cyclotron which was installed in Korea Cancer Center Hospital are described. The vacuum system comprises five subgroups and the operating sequences are automatically controlled by EPROM-programmable controller. In normal operation, the obtained ultimate pressures of vacuum groups were $5{\times}10^{-6}mbar(I,\;II),\;2{\times}10^{-6}mbar(III),\;1.2{\times}10^{-5}mbar(IV),\;1.5{\times}10^{-6}mbar(V)$, respectively. It was confirmed that these pressures was enough to accelerate the 50 MeV-proton beam.

  • PDF

Acquisition of High Resolution Images and its Application using Synchrotron Radiation Imaging System (방사광 X-선을 이용한 고해상도 영상획득과 응용)

  • 홍순일;김희중;정해조;홍진오;정하규;김동욱;제정호;김보라;유형식
    • Progress in Medical Physics
    • /
    • v.12 no.1
    • /
    • pp.51-58
    • /
    • 2001
  • Synchrotron radiation (SR) has several advantages over convetional x-rays, including its phase, collimation, and high flux. A synchrotron radiation beamline 5C1 at Pohang Light Source (PLS) was recently built for imaging applications. We have shown that a SR imaging system is useful in imaging microscopic structures. SR with broad-band energy spectrum were adjusted to an object by Si wafers and their energy were approximately ranging from 6 keV to 30 keV. SR were passed through an object and finally transformed into visible lights by CdWO$_4$ scintillator screen. The visible lights which were reflected at an angle of 90 degrees by gold plated mirror were detected by a CCD camera and the image data were acquired using image acquisition system. A high-resolution phantom, capacitor, adult tooth, child tooth, cancerous breast tissue, and mouse lumbar vertebra were imaged with SR imaging system. The Objects were rotated within the field of view of the CCD detector, and their projection image data were obtained at 250 steps over 180 degrees rotation. Image reconstructions were carried out in a PC by using IDLTM(Research systems, Inc., US) program. The spatial resolution of the images acquired by the SR imaging system was measured with a high-resolution chart manufactured for several micrometer resolution. The specimens were also imaged with conventional x-ray radiography system to compare the image quality of radiography obtained with the SR imaging system. The results showed more structural details and high contrast images with SR imaging system than conventional x-ray radiography system. The SR imaging system may have a potential for imaging in biological researches, material applications, and clinical radiography.

  • PDF

Growth and electro-optical characteristics of CdSe/GaAs epilayers prepared by electron beam epitaxy (전자빔 증착법에 의한 CdSe/GaAs epilayer의 성장과 그 전기-광학적 특성)

  • Yang, D.I.;Shin, Y.J.;Lee, C.H.;Choi, Y.D.;Yu, P.R.
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.7 no.1
    • /
    • pp.70-75
    • /
    • 1997
  • An improved technique based upon an electron beam evaporation system has been developed to prepare cubic thin films In crystalline semiconductors. Zinc blonde CdSe epilayers were grown on GaAs(100) substrate by an e-beam evaporation method. The lattice parameter obtained from (400) reflection is $6.077\AA$, which is in excellent agreement with the value reported in the literature for zinc blonde CdSe. The orientation of the as-grown CdSe epilayer is determined by electron channeling patterns. The crystallinity of epitaxial CdSe layers were investigated on the double crystal X-ray rocking curve. The carrier concentration and mobility of epilayers deduced by Hall effect measurement are about $10^{18}{\textrm}{cm}^{-3}$, $10^2\textrm{cm}^2/V{\cdot}sec$ at room temperature, respectively. The photocurrent spectrum peak of the epilayer at 30 K exhibits a sharp change at 1.746 eV due to the free exciton of cubic CdSe.

  • PDF