• Title/Summary/Keyword: PC구조

Search Result 1,129, Processing Time 0.036 seconds

Design and Implementation of Visual Environment for Parallel Object-Oriented Programming (병렬 객체지향 프로그래밍을 위한 시각 환경의 설계 및 구현)

  • Choe, Suk-Yeong
    • The Transactions of the Korea Information Processing Society
    • /
    • v.6 no.2
    • /
    • pp.485-496
    • /
    • 1999
  • Comparing with sequential programming, parallel programming has additional complexity due to the consideration of parallelism, communication and synchronization of processes. A synergism between users and compliers should be established, each assisting the other to produce high quality parallel programs. On the above underlying philosophy, we developed a parallel Object-Oriented specification language, POOSL, as preliminary works. However, it is still likely to hard for users to write parallel program because users have to consider grammar of POOSL and to write text-based parallel program. It would be more desirable to provide users wit visual environment for effective parallel programming. Therefore, we propose a visual programming environment. VEPO(Visual environment for Parallel Object-Oriented Programming), based on POOSL in order that users can develop parallel programs more easily and conveniently. It aims at supporting a programming environment in which users can represent their programs more naturally and visually I parallel manner with object-oriented concept and essential steps during parallel program development such as program specification, compilation, execution and animation of execution are integrated. VEPO has useful features for parallel processing. Especially, complicated parallel codes for synchronization and communication of processes are automatically generated in the translation phase, so users can be relieved of writing error-prone parallel codes. The system is targeted to the transputer-based parallel system, MC-3. The graphic user interface of VEPO was implemented using Visual C++. Visual programs descirbed on VEPO are translated into Inmos C and executed on MC-3.

  • PDF

Simulations of Temporal and Spatial Distributions of Rainfall-Induced Turbidity Flow in a Reservoir Using CE-QUAL-W2 (CE-QUAL-W2 모형을 이용한 저수지 탁수의 시공간분포 모의)

  • Chung, Se-Woong;Oh, Jung-Kuk;Ko, Ick-Hwan
    • Journal of Korea Water Resources Association
    • /
    • v.38 no.8 s.157
    • /
    • pp.655-664
    • /
    • 2005
  • A real-time monitoring and modeling system (RTMMS) for rainfall-induced turbidity flow, which is one of the major obstacles for sustainable use of reservoir water resources, is under development. As a prediction model for the RTMMS, a laterally integrated two-dimensional hydrodynamic and water quality model, CE-QUAL-W2 was tested by simulating the temperature stratification, density flow regimes, and temporal and spatial distributions of turbidity in a reservoir. The inflow water temperature and turbidity measured every hour during the flood season of 2004 were used as the boundary conditions. The monitoring data showed that inflow water temperature drop by 5 to $10^{\circ}C$ during rainfall events in summer, and consequently resulted in the development of density flow regimes such as plunge flow and interflow in the reservoir. The model showed relatively satisfactory performance in replicating the water temperature profiles and turbidity distributions, although considerable discrepancies were partially detected between observed and simulated results. The model was either very efficient in computation as the CPU run time to simulate the whole flood season took only 4 minutes with a Pentium 4(CPU 2.0GHz) desktop computer, which is essentially requited for real-time modeling of turbidity plume.

A Fast Sensing Method using Concurrent Driving and Sequential Sensing for Large Capacitance Touch Screens (동시구동 및 순차센싱을 이용한 대형 정전용량 터치스크린용 고속 센싱 기법)

  • Mohamed, Mohamed G.A.;Kim, HyungWon;Cho, Tae-Won
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.4
    • /
    • pp.62-70
    • /
    • 2015
  • Recently the demand for projected capacitance touch screens is sharply growing especially for large screens for medical devices, PC monitors and TVs. Large touch screens in general need a controller of higher complexity. They usually have a larger number of driving and sensing lines, and hence it takes longer to scan one frame for touch detection leading to a low frame scan rate. In this paper, a novel touch screen control technique is presented, which scans each frame in two steps of simultaneous multi-channel driving. The first step is to drive all driving lines simultaneously and determine which sensing lines have any touch. The second step is to sequentially rescan only the touched sensing lines, and determine exact positions of the touches. This technique can substantially increase the frame scan rate. This technique has been implemented using an FPGA and an AFE board, and tested using a commercial 23-inch touch screen panel. Experimental results show that the proposed technique improves the frame scan rate by 8.4 times for the 23-inch touch screen panel over conventional methods.

The Rheology of Cement Paste Using Polycarboxylate-Based Superplasticizer for Normal Strength-High Fluidity Concrete (보통강도 고유동 콘크리트용 PC계 고성능 감수제를 사용한 시멘트 페이스트의 레올로지 특성 평가)

  • Kong, Tae-Woong;Lee, Han-Seung
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.9 no.3
    • /
    • pp.276-286
    • /
    • 2021
  • General high fluidity concrete is the area of high strength concrete with a high amount of cement to secure the required fluidity and workability. Since most of the concrete structures currently used have normal strength, there is a limit to the practical expansion and practicality of use. Thus it is necessary to develop normal strength-high fluidity concrete with low binders that can be used not only in general buildings but also in special buildings, and can greatly reduce construction time and save labor costs. This requires to develop and apply the polycarboxylate-based superplasticizer. In this study, PCE was prepared for each combination of starting materials(WR, HB, RT) and the rheological properties of cement paste were analyzed using ringflow cone and a rotary viscometer. As a result, when PCE with a combination of WR 80%, HB 6.5%, and RT 13.5% was applied, the yield stress can be minimized while securing the plastic viscosity at level of the normal strength. In addition, high fluidity due to the high dispersion effect was confirmed.

Development of Robot Platform for Autonomous Underwater Intervention (수중 자율작업용 로봇 플랫폼 개발)

  • Yeu, Taekyeong;Choi, Hyun Taek;Lee, Yoongeon;Chae, Junbo;Lee, Yeongjun;Kim, Seong Soon;Park, Sanghyun;Lee, Tae Hee
    • Journal of Ocean Engineering and Technology
    • /
    • v.33 no.2
    • /
    • pp.168-177
    • /
    • 2019
  • KRISO (Korea Research Institute of Ship & Ocean Engineering) started a project to develop the core algorithms for autonomous intervention using an underwater robot in 2017. This paper introduces the development of the robot platform for the core algorithms, which is an ROV (Remotely Operated Vehicle) type with one 7-function manipulator. Before the detailed design of the robot platform, the 7E-MINI arm of the ECA Group was selected as the manipulator. It is an electrical type, with a weight of 51 kg in air (30 kg in water) and a full reach of 1.4 m. To design a platform with a small size and light weight to fit in a water tank, the medium-size manipulator was placed on the center of platform, and the structural analysis of the body frame was conducted by ABAQUS. The robot had an IMU (Inertial Measurement Unit), a DVL (Doppler Velocity Log), and a depth sensor for measuring the underwater position and attitude. To control the robot motion, eight thrusters were installed, four for vertical and the rest for horizontal motion. The operation system was composed of an on-board control station and operation S/W. The former included devices such as a 300 VDC power supplier, Fiber-Optic (F/O) to Ethernet communication converter, and main control PC. The latter was developed using an ROS (Robot Operation System) based on Linux. The basic performance of the manufactured robot platform was verified through a water tank test, where the robot was manually operated using a joystick, and the robot motion and attitude variation that resulted from the manipulator movement were closely observed.

Development of Water Risk Management Platform for Indonesia Area (인도네시아 물 재해 관리 플랫폼 개발과 적용성 평가)

  • Park, Dae Hee;Park, Joo Seok
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.381-381
    • /
    • 2019
  • 동남아시아의 급격한 도시인구 증가는 도시화로 파생되는 제반문제를 유발하고 있으며 특히 집중호우와 홍수배제 시설의 부족 및 유관시설의 정보관리체계 부재는 홍수 피해규모를 가중시키고 있다. 인도네시아의 경우 물 재해 관리기관 간의 정보공유체계 부재로, 홍수로 인한 문제해결에 대하여 효과적인 대응이 어려운 실정이다. 주요 물 관리 기관인 유역관리청(BBWS)의 경우 조기홍수경보시스템을 보유하고 있으나 단순 수문현황 모니터링에 국한되어 운영되고 있다. 이에 본 연구에서는 홍수피해를 최소화 할 수 있는 동남아시아 맞춤형 물 재해 관리 클라우드 플랫폼을 개발하여 비구조적 홍수 문제해결의 매개체로 활용하고자 한다. 기본적인 유역 수문현황 모니터링과 함께 댐, 보, 배수문 및 펌프장 등 홍수방어시설물의 운영현황 정보, 홍수상황분석, 홍수위험지도 등 종합적인 물 재해 정보를 제공하고 사전에 홍수위험 지역을 분석하여 유관기관과 공유할 수 있는 물 재해 관리 의사결정지원시스템을 개발하고자 한다. 기본적인 정보관리 체계화를 위하여 인도네시아의 다양한 물 재해 관련기관에서 보유하고 있는 자료들의 통합 클라우드 DB관리 시스템을 구축하였다. 연구대상지역은 인도네시아 수도인 자카르타의 Pesanggrahan유역과 인근 Batam섬 Baloi유역을 선정하였으며 대상 유역의 수문, 기상자료 및 GIS 정보수집은 공동연구기관인 인도네시아 공공사업부 수자원청(MPWH)과 주요 물 관리기관인 유역관리청(BBWS)의 협조를 통하여 진행하였다. 수집된 자료들은 관계형 데이터베이스 관리시스템인 MySQL을 사용하여 통합 물 재해 정보 데이터베이스를 구축하였으며 완성된 데이터베이스의 정보제공 및 공유시스템은 웹기반 인터페이스를 통해 관리되도록 설계하였다. 홍수유출 해석을 위한 분석 엔진은 K-water의 홍수분석 시스템인 FAS를 이용하였다. FAS의 홍수분석모형인 COSFIM과 수리모형인 Fldwav를 연계하는 데이터 분석 플랫폼을 완성하였으며 인도네시아 현지 조건에 부합하는 홍수분석 시스템으로 Customizing과정을 수행하였다. 또한 FAS의 PC기반 시뮬레이션 형식을 DB 연계형 웹서비스 방식으로 연동되도록 개량하였으며 추후 SaaS형 물 재해 분석시스템으로 전환할 수 있는 개발환경을 확보하였다. 개발된 물 재해 분석 플랫폼(WRMP)을 활용하여 인도네시아 공동연구기관과의 협의를 통해 물 재해 관리 시나리오를 수립하고 그 대안을 제시하였으며, 적용 시나리오별 홍수피해 저감 효과를 분석하였다. 또한 향후 방재시설물까지 연계하여 운영효과를 분석할 수 있도록 구조화하였다. 개발된 물 재해 관리 시스템은 개선된 정보처리 및 분석시스템을 활용하여 종합적인 물 재해정보를 제공하고, 사전에 홍수위험 지역을 분석하여 유관기관과 공유할 수 있는 물 재해 관리 의사결정 지원시스템으로써 유용하게 활용될 수 있을 것이다.

  • PDF

Synthesis and characterization of PPG-based urethane-modified epoxy resin for enhancing impact resistance of epoxy composite resin (에폭시 복합수지의 내충격성을 향상을 위한 PPG 기반 우레탄 변성 에폭시 합성 및 특성 분석)

  • Hwang, Chiwon;Jeon, Jaehee;Ahn, Dowon;Yu, Youngchang;Lee, Wonjoo
    • Journal of Adhesion and Interface
    • /
    • v.23 no.2
    • /
    • pp.44-52
    • /
    • 2022
  • Epoxy resin has the disadvantage of being easily destroyed by instantaneous impact due to its high crosslinking density despite its high glass transition temperature (Tg) and excellent properties. To compensate for this, in this study, polyol was synthesized by ring opening polymerization of propylene glycol (PPG) diamine, Jeffamine D 2000 and propylene carbonate, and urethane modified epoxy was synthesized using this. The properties of the synthesized urethane modified epoxy were confirmed by FT-IR, H-NMR. To confirm the degree of improvement in impact resistance as an adhesive, a urethane modified epoxy adhesive was prepared by mixing a digylcidyl ether bisphenol A (DGEBA) with curing agent and curing accelerator. Properties test of urethane modified epoxy were shear strength, tensile strength and impact strength. As a result, excellent results were obtained in all test when the ratio of DGEBA : urethane modified epoxy was 8:2.

A Study on the Stiffness of CBA(Corner Block with Anchor Bolt) Joint in Knockdown Type Table Furniture (조립식(組立式) 탁자(卓子)의 CBA접합부(接合部) 강성(剛性)에 관(關)한 연구(硏究))

  • Chung, Woo-Yang;Lee, Phil-Woo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.17 no.2
    • /
    • pp.34-64
    • /
    • 1989
  • Corner block with anchor bolt(CBA) joint method used in knock-down type table furniture manufacturing can reduce the packing and transporting cost. Unfortunately. it also has the disastrous defect to be loosend and unstable during the service life mainly due to fatigue and creep(repeated and prolonged loading). So 22 joint groups constructed were tested to evaluate the effect of some design factors related to the size of side rail(apron). block attachment to side rail. and the number of anchor bolt as well as the effect of the type of corner block(mitered type vs. rectangular type) Usable strength from the stiffness coefficients of each joint group were analysed with SPSS /PC+ and described as the criteria of CBA joint construction. The conclusions were as follows: The height of side rail(50, 75 and 100 mm) and the addition of polyvinyl acetate(PVAc) emulsion in the corner block attactment to side rail had the effect on raising the usable strength of CBA joint with remarkable high significance. And the effect of 2 - anchor bolts was also superior to that of 1 - bolt significantly. However. the thickness of side rail(22 mm vs. 25 mm) had no effect on the strengthening the table joint rigidity. Mitered type corner block joint appeared to he recommendable for CBA jointed table construction rather than the rectangular type one regardless of the method of block attachment to side rail. The best result identified from Duncan's multiple comparison was in the construction with 25 mm thick and 100 mm height of side rail fastened using 2 - anchor bolts in mitered type corner block. But it would be reasonable to use 22 mm thick & 75 mm high side rail and mitered corner block with PVAc emulsion & 2 bolts considering the productivity and production cost down in the MDF furniture manufacturing industries.

  • PDF

Efficiency and continuancy of basic CPR (Cardiopulmonary Resuscitation) education for the higher grade students of elementary schools (초등학교 고학년생의 기본심폐소생술 교육효과 및 지속성)

  • Kim, Hee-Jung
    • The Korean Journal of Emergency Medical Services
    • /
    • v.12 no.3
    • /
    • pp.87-98
    • /
    • 2008
  • Purpose : This study was designed to figure out the necessity of continuing basic CPR education for the higher grade students of elementary school. The assessment contents were knowledge, practice ability, precision level of CPR skills and continuation of the educational efficiency. Methods : Twenty two students of 4th and 5th grade of elementary school in K city in Chungcheongnam-do were recruited for this study. The study method was a control group of non-synchronized design. A preliminary study was done on October 27 in 2006. The main study was performed from February 14 to May 11 in 2007. The researcher adopted the method of Kyung-hui, Kang (1998) such as awareness, attitude and knowledge in control group, emergency medical technician test protocol, Anne/SkillReporter$^{(R)}$ in case of the basic CPR knowledge. Four times of measures were done in shortly after practicing CPR, 4 weeks after the education, 8 weeks after the education, and 12 weeks after the education. By using SPSS/PC+ (version 12.0), the researcher analyzed the collected data based on frequency, percentage, repeated measurement, ANOVA (analysis of variance), and sidak (multiple comparison - sidak). Results : 1) The confidence of people in the control group in terms of practicing CPR showed a statistically meaningful difference (t = 10.230, p = .000) before/after CPR education. Therefore, hypothesis No.1-1 was accepted. 2) The educational necessity of people in the control group showed no statistically meaningful difference (t = -1.695, p = 0.105) before/after CPR education. Therefore, hypothesis No.1-2 was rejected. 3) The knowledge points of people in the control group showed a statistically meaningful difference (t = -7.731, p = .000) before/after CPR education. Therefore, hypothesis No.2 was accepted. 4) The confidence of people in the control group in terms of practicing CRP showed no meaningful difference (F = 2.789, p = 0.072) as time passed. Therefore, hypothesis No.3 was rejected. 5) The knowledge of people in the control group showed a meaningful difference (F = 9.090, p = .000) as time passed. Therefore, hypothesis No.4 was accepted. 6) The capability of people in the control group in terms of practicing CPR showed a statistically meaningful difference (F = 42.795, p = .000) as time passed. Therefore, hypothesis No.5 was accepted. 7) The precision level of CPR skill of people in the control group showed a statistically meaningful difference (F = 25.198, p = .000) as time passed. Therefore, hypothesis No.6-1 was accepted. 8) The precision level of chest compression skill of people in the control group showed a statistically meaningful difference (F = 5.188, p = .003). Therefore, hypothesis No.6-2 was accepted. Conclusion : In a nutshell, CPR education for the 4th and 5th graders of elementary schools had an influence on their confidence in practicing CPR and on their knowledge. This study showed that as time passed. the educational effect declined in terms of knowledge point, capability of practicing CPR, and the precision level of CRP skill. The results of the study could be postulated into the fact that re-education within 8 weeks after the first education was essential to retaining the educational effect. Therefore, we need to vitalize the CPR education for elementary school students repeatedly on a regular basis in order to continue the educational effect after they were grown-ups and to make them play their roles as a first aider.

  • PDF

Medical Information Dynamic Access System in Smart Mobile Environments (스마트 모바일 환경에서 의료정보 동적접근 시스템)

  • Jeong, Chang Won;Kim, Woo Hong;Yoon, Kwon Ha;Joo, Su Chong
    • Journal of Internet Computing and Services
    • /
    • v.16 no.1
    • /
    • pp.47-55
    • /
    • 2015
  • Recently, the environment of a hospital information system is a trend to combine various SMART technologies. Accordingly, various smart devices, such as a smart phone, Tablet PC is utilized in the medical information system. Also, these environments consist of various applications executing on heterogeneous sensors, devices, systems and networks. In these hospital information system environment, applying a security service by traditional access control method cause a problems. Most of the existing security system uses the access control list structure. It is only permitted access defined by an access control matrix such as client name, service object method name. The major problem with the static approach cannot quickly adapt to changed situations. Hence, we needs to new security mechanisms which provides more flexible and can be easily adapted to various environments with very different security requirements. In addition, for addressing the changing of service medical treatment of the patient, the researching is needed. In this paper, we suggest a dynamic approach to medical information systems in smart mobile environments. We focus on how to access medical information systems according to dynamic access control methods based on the existence of the hospital's information system environments. The physical environments consist of a mobile x-ray imaging devices, dedicated mobile/general smart devices, PACS, EMR server and authorization server. The software environment was developed based on the .Net Framework for synchronization and monitoring services based on mobile X-ray imaging equipment Windows7 OS. And dedicated a smart device application, we implemented a dynamic access services through JSP and Java SDK is based on the Android OS. PACS and mobile X-ray image devices in hospital, medical information between the dedicated smart devices are based on the DICOM medical image standard information. In addition, EMR information is based on H7. In order to providing dynamic access control service, we classify the context of the patients according to conditions of bio-information such as oxygen saturation, heart rate, BP and body temperature etc. It shows event trace diagrams which divided into two parts like general situation, emergency situation. And, we designed the dynamic approach of the medical care information by authentication method. The authentication Information are contained ID/PWD, the roles, position and working hours, emergency certification codes for emergency patients. General situations of dynamic access control method may have access to medical information by the value of the authentication information. In the case of an emergency, was to have access to medical information by an emergency code, without the authentication information. And, we constructed the medical information integration database scheme that is consist medical information, patient, medical staff and medical image information according to medical information standards.y Finally, we show the usefulness of the dynamic access application service based on the smart devices for execution results of the proposed system according to patient contexts such as general and emergency situation. Especially, the proposed systems are providing effective medical information services with smart devices in emergency situation by dynamic access control methods. As results, we expect the proposed systems to be useful for u-hospital information systems and services.