• Title/Summary/Keyword: PACS (Picture Archiving and Communication System)

Search Result 83, Processing Time 0.027 seconds

Role-based User Access Control with Working Status for u-Healthcare System (u-Healthcare 시스템을 위한 RBAC-WS)

  • Lee, Bong-Hwan;Cho, Hyun-Sug
    • The KIPS Transactions:PartC
    • /
    • v.17C no.2
    • /
    • pp.173-180
    • /
    • 2010
  • Information technology is being applied to the development of ubiquitous healthcare system, which provides both efficient patient care and convenient treatment regardless of patient's location. However, the increasing number of users and medical information give rise to the problem of user management and the infringement of privacy. In order to address this problem we propose a user access scheme based on the RBAC (Role Based Access Control) model. The preceding trust management model for Grid security, FAS(Federation Agent Server), was analyzed and extended to provide supplementary functions for role-based access control in u-Healthcare system. The RBAC model provides efficient user management and access control, but very vulnerable in case when one with valid role tries to leak confidential inner medical information. In order to resolve this problem, a RBAC-WS (Work Status with RBAC) model has been additionally developed which allows only qualified staffs to access the system while on duty. Th proposed RBAC and RBAC-WS model have been merged together and applied to the PACS (Picture Archiving and Communication System).

Current Status and Problems of PET/CT Data on CD for Inter-hospital Transfer (병원간 전송용 PET/CT 영상 CD자료의 현황 및 문제점)

  • Hyun, Seung-Hyup;Choi, Joon-Young;Lee, Su-Jin;Cho, Young-Seok;Lee, Ji-Young;Cheon, Mi-Ju;Cho, Suk-Kyong;Lee, Kyung-Han;Kim, Byung-Tae
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.2
    • /
    • pp.137-142
    • /
    • 2009
  • Purpose: This study was performed to find the current problems of positron emission tomography/computed tomography(PET/CT) data on CD for inter-hospital transfer. Materials and Methods: The subjects were 746 consecutive $^{18}F$-fluorodeoxyglucose PET/CT data CDs from 56 hospitals referred to our department for image interpretation. The formats and contents of PET/CT data CDs were reviewed and the email questionnaire survey about this was performed. Results: PET/CT data CDs from 21 of 56 hospitals(37.5%) included all transaxial CT and PET images with DICOM standard format which were required for authentic interpretation. PET/CT data from the others included only secondary capture images or fusion PET/CT images. According to this survey, the main reason of limited PET/CT data on CD for inter-hospital transfer was that the data volume of PET/CT was too large to upload to the Picture Archiving and Communication System. Conclusion: The majority of hospitals provided limited PET/CT data on CD for inter-hospital transfer, which could be inadequate for accurate interpretation and clinical decision making. It is necessary to standardize the format of PET/CT data on CD for inter-hospital transfer including all transaxial CT and PET images with DICOM standard format.

A Study on Reduction Effect of Processing Wastewater by Introduction of PACS (PACS 도입에 의한 현상시스템 폐수 감소효과에 관한 연구)

  • Ko, Shin-Kwan;Han, Dong-Kyoon;Kim, Wook-Dong;Kang, Bung-Sam;Yang, Han-Jun
    • Journal of radiological science and technology
    • /
    • v.30 no.2
    • /
    • pp.167-175
    • /
    • 2007
  • There are some positive effects by the introduction of PACS(Picture Archiving Communication System). This study is to analyze the mutual relation between before and after of the introduction of PACS in terms of the environment effect. It is supposed to cause the reduction of developing and fixing wastewater according to the increase in the rate of a non-film. This study will also show the amount of wastewater. Target places were the department of image medicine(diagnostic radiation) of the general hospitals in Seoul and Gyeonggi-Do, which are equiped with full PACS. The authors examined questionnaires on the number of projection, the number of indirect projection, the amount of the film used, the number of radiation image CD loan, the amount of the developing and fixing solution used, the change of the amount of fixing wastewater. According to the analysis, we analyzed the change of the amount of developing and fixing solution per a film and the change of the amount of developing and fixing wastewater which is supposed to be reduced proportionally by the introduction of PACS. We got conclusion as below after analyzing 8 hospitals except the largest and the least amount of examination, film used, developing and fixing solution and the amount of developing and fixing wastewater in order to decrease the deviation from 10 general hospitals located in Seoul and Gyeonggi-Do. We compared data one year before adopting PACS Versus 3 years after adopting PACS. 1. The frequences of examination increased to 7,357.7 cases per month but the amount of film used decreased to 90%, from 42,774.4 to 4,181.88 after adopting the PACS. 2. 3 years after adopting PACS, monthly average amount of developing solution used decreased to 92% and the monthly average amount of fixing solution decreased to 86%. 3. Monthly average amount of developing solution used per film increased to 1.49 times and fixing solution increased as much as three times. 4. Monthly average wastewater for developing decreased to 88% and wastewater for fixing decreased up to 87%. 5. Monthly average wastewater for developing per film increased to 3.77 times and wastewater for fixing increased to 3.85 times. Although the amount of film used and the amount of developing and fixing wastewater affected by the reduction of the developing and fixing solution became less on the whole by introduction of PACS, they did not decrease proportionally. Moreover the amount of the developing and fixing solution used and the amount of developing and fixing wastewater per a film increased. That means the expectation for an environmental improvement differs from the actual condition.

  • PDF

Imaging Characteristics of Computed Radiography Systems (CR 시스템의 종류와 I.P 크기에 따른 정량적 영상특성평가)

  • Jung, Ji-Young;Park, Hye-Suk;Cho, Hyo-Min;Lee, Chang-Lae;Nam, So-Ra;Lee, Young-Jin;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.19 no.1
    • /
    • pp.63-72
    • /
    • 2008
  • With recent advancement of the medical imaging systems and picture archiving and communication system (PACS), installation of digital radiography has been accelerated over past few years. Moreover, Computed Radiography (CR) which was well established for the foundation of digital x-ray imaging systems at low cost was widely used for clinical applications. This study analyzes imaging characteristics for two systems with different pixel sizes through the Modulation Transfer Function (MTF), Noise Power Spectrum (NPS) and Detective Quantum Efficiency (DQE). In addition, influence of radiation dose to the imaging characteristics was also measured by quantitative assessment. A standard beam quality RQA5 based on an international electro-technical commission (IEC) standard was used to perform the x-ray imaging studies. For the results, the spatial resolution based on MTF at 10% for Agfa CR system with I.P size of $8{\times}10$ inches and $14{\times}17$ inches was measured as 3.9 cycles/mm and 2.8 cycles/mm, respectively. The spatial resolution based on MTF at 10% for Fuji CR system with I.P size of $8{\times}10$ inches and $14{\times}17$ inches was measured as 3.4 cycles/mm and 3.2 cycles/mm, respectively. There was difference in the spatial resolution for $14{\times}17$ inches, although radiation dose does not effect to the MTF. The NPS of the Agfa CR system shows similar results for different pixel size between $100{\mu}m$ for $8{\times}10$ inch I.P and $150{\mu}m$ for $14{\times}17$ inch I.P. For both systems, the results show better NPS for increased radiation dose due to increasing number of photons. DQE of the Agfa CR system for $8{\times}10$ inch I.P and $14{\times}17$ inch I.P resulted in 11% and 8.8% at 1.5 cycles/mm, respectively. Both systems show that the higher level of radiation dose would lead to the worse DQE efficiency. Measuring DQE for multiple factors of imaging characteristics plays very important role in determining efficiency of equipment and reducing radiation dose for the patients. In conclusion, the results of this study could be used as a baseline to optimize imaging systems and their imaging characteristics by measuring MTF, NPS, and DQE for different level of radiation dose.

  • PDF

Comparison of Muscle Thickness and Changing Ratio for Cervical Flexor Muscles During the Craniocervical Flexion Test Between Subjects With and Without Forward Head Posture

  • Lee, Jae-hyun;Hwang, Ui-jae;Kwon, Oh-yun
    • Physical Therapy Korea
    • /
    • v.29 no.3
    • /
    • pp.180-186
    • /
    • 2022
  • Background: The craniocervical flexion test (CCFT) was developed for the activation and endurance of deep cervical flexors. However, the muscle thickness and muscle thickness changing ratio of the sternocleidomastoid (SCM) and deep cervical flexor (DCF) muscles in subjects with and without forward head posture (FHP) have not been reported. Objects: To determine the difference in thickness of the SCM and DCF muscles and the difference in the muscle thickness changing ratio between SCM, DCF, and DCF/SCM 20 mmHg and DCF/SCM 30 mmHg between subjects with and without FHP. Methods: Thirty subjects with and without FHP were enrolled. The muscle thickness of the SCM and DCF was measured when maintained at a baseline pressure of 20 mmHg and a maximum pressure of 30 mmHg using a pressure biofeedback unit during the CCFT. Ultrasonography was used to capture images of SCM and DCF muscle thickness during the CCFT, which was calculated using the picture archiving and communication system (PACS). Results: We observed a significant difference within the pressure main effect between SCM and DCF at a baseline pressure of 20 mmHg and a maximum pressure of 30 mmHg (p < 0.05). However, there was no significant difference in the muscle thickness and muscle thickness changing ratio for SCM and DCF during CCFT between subjects with and without FHP. Conclusion: There was no significant difference in the muscle thickness recruitment pattern during CCFT in posture changes between subjects with and without FHP.

Usefulness of the Oblique Radiographic View in Ankle Fractures (족근 관절 골절에서 사면상 단순 방사선 사진의 유용성)

  • Cho, Duck-Yun;Song, Sang-Jun;Yoon, Hyung-Ku;Han, Soo-Hong;Chang, Ji-Hoon;Yoon, Byung-Ho
    • Journal of Korean Foot and Ankle Society
    • /
    • v.9 no.1
    • /
    • pp.94-98
    • /
    • 2005
  • Purpose: To compare the radiographic evaluations between two radiographic views (AP and lateral views) and four radiographic views (AP, lateral and both oblique views) in ankle fractures. Materials and Methods: From January 2000 to June 2002, 60 cases of ankle fractures were treated with open reduction and internal fixation and its followed up periods were at least 2 years. All cases were classified into three groups according to the method of preoperative radiographic evaluation. Two radiographic views (AP and lateral views) were taken in group A and four radiographic views (AP, lateral and both oblique views) were taken in group B. 12 Cases were evaluated with three dimensional computed tomography (3D CT). Four radiographic views and 3D CT were taken in group C. All cases were classified according to the Danis-Weber and Lauge-Hansen classification. Displacement of fracture fragment of medial, lateral, posterior malleolus and size of fracture fragment of posterior malleous were measured using picture archiving communication system (PACS). Results: Although kappa value between two or four radiographic views were good or excellent in Danis-Weber classification and Lauge-Hansen classification of ankle fractures, the displacements of medial and lateral malleoli were statistically different. Four radiographic views evalulated the degree of displacement of medial and lateral fragments more accurately compared to two radiographic views. Conclusion: Four radiographic views will be more useful than two radiographic views to decide the method of treatment and operation considering the displacement of fracture fragment.

  • PDF

Postoperative Clinical Outcome and Risk Factors for Poor Outcome of Foraminal and Extraforaminal Lumbar Disc Herniation

  • Bae, Jung Sik;Kang, Kyung Hee;Park, Jeong Hyun;Lim, Jae Hyeon;Jang, Il Tae
    • Journal of Korean Neurosurgical Society
    • /
    • v.59 no.2
    • /
    • pp.143-148
    • /
    • 2016
  • Objective : We evaluated postoperative outcomes in patients who have lumbar foraminal or extraforaminal disc herniation (FELDH) and suggested the risk factors for poor outcomes. Methods : A total of 234 patients were selected for this study. Pre- and post-operative Visual Analogue Scale (VAS) and Korean version Oswestry Disability Index (KODI) were evaluated and the changes of both score were calculated. Outcome was defined as excellent, good, fair, and poor based on Mcnab classification. The percentage of superior facetectomy was calculated by using the Maro-view 5.4 Picture Archiving Communication System (PACS). Results : Paramedian lumbar discectomy was performed in 180 patients and combined lumbar discectomy was performed in 54 patients. Paramedian lumbar discectomy group showed better outcome compared with combined discectomy group. p value of VAS change was 0.009 and KODI was 0.013. The average percentage of superior facetectomy was 33% (range, 0-79%) and it showed negative correlation with VAS and KODI changes (Pearson coefficient : -0.446 and -0.498, respectively). Excellent or good outcome cases (Group I) were 136 (58.1%) and fair or poor outcome cases (Group II) were 98 (41.9%). The percentage of superior facetectomy was 26.5% at Group I and 42.5% at Group II. There was significant difference in superior facetectomy percentage between Group I and II (p=0.000). Conclusion : This study demonstrated that paramedian lumbar discectomy with preservation of facet joints is an effective and good procedure for FELDH. At least 60% of facet should be preserved for excellent or good outcomes.

Lumbar Spine Kinematics during Anterior and Posterior Pelvic Tilting in Supine and Prone Positions

  • Park, So-Hyun;Yuk, Goon-Chang;Ahn, Sang-Ho;Lee, Dong-Gyu;Choi, Jin-Ho;Oh, Hyun-Ju;Park, Kwan-Yong
    • The Journal of Korean Physical Therapy
    • /
    • v.23 no.6
    • /
    • pp.9-14
    • /
    • 2011
  • Purpose: The pelvic tilting exercise is a well recognized rehabilitation maneuver. However, little information is available on the changes of lumbar segmental motion during pelvic tilting. This study was conducted to measure the kinematics of the pelvic tilting exercise on the supine and prone positions via fluoroscopy. Methods: A total of 10 female subjects were enrolled. During anterior, neutral, and posterior pelvic tilting, radiographs were taken in each exercise via fluoroscopy (ARCADIS Orbic, Siemens, USA). Images were sent to the picture archiving communication system (PACS), and the digitized images were analyzed using LabVIEW software (National Instruments, USA). Lumbosacral lordosis and the intervertebral body angle, intervertebral disc angle, and intervertebral displacement were analyzed. Results: The results of lumbar kinematic analysis during three tilting postures in the supine and prone positions demonstrated that lumbosacral lordosis and the intervertebral body angle and intervertebral disc angle were significantly higher when the pelvis was tilted anteriorly (p>0.05). However, there was no significant difference between anterior and neutral tilting in the intervertebral disc angle at the L3/4 level in the prone position (p>0.05), and there was no significant difference among tilting positions in intervertebral body displacement in the prone position (p>0.05). Conclusion: This study provides scientific evidence about the pelvic tilting exercise in lumbosacral segmental motion. Depending on the pelvic tilting exercise, kinematic changes were demonstrated in both positions, especially in the supine position. It is suggested that the supine position is effective for mobility, but it should be used carefully for the LBP (Low back pain) patient with hypermobility.

Polyurethane Foam Template for Simple Design of Digital Island Flap (폴리우레탄 폼 드레싱재료를 이용한 간단한 손가락 섬피판 디자인)

  • Kim, Nam-Joong;Choi, Hwan-Jun;Kim, Jun-Hyuk
    • Archives of Reconstructive Microsurgery
    • /
    • v.18 no.1
    • /
    • pp.35-39
    • /
    • 2009
  • Purpose: Various techniques have been attempted for design of the flaps. However, there are some disadvantages. They have thin, pliable, and two dimensional methods. The aim of this study is to report usefulness of polyurethane foam dressing materials for three dimensional design of the digital island flap. Methods: From June of 2007 to september of 2008, 10 patients received digital island flap surgery for soft tissue defect of the finger. After minimal debridement of the wound, size and shape of the defect were measured using polyurethane foam. We used Medifoam-$5^{(R)}$ And then, designed this inset the wound. The flap was designed on the donor site with a arterial pedicle as the central axis according to size and shape. A full thickness skin graft from the groin is applied on the flap donor defect and secured with a tieover bolster dressing. Results: Reviewing sizes of the flaps, the length and width of flaps ranged from 1.5 to 3.3 cm and 1.0 to 2.5 cm. The PACS(Picture Archiving Communication System) program allows identification of the donor depth of finger. The distance for the soft tissue ranged from 4.3 mm to 6.7 mm. Mean depth of donor site was 5.3${\pm}$0.6 mm. Also, the thickness of Medifoam-$5^{(R)}$ ranged nearly 5 mm. On flap insetting, full-thickness skin graft was necessary. We did not experience any problems in the recipient site size either, regardless of the extended flaps. Conclusion: Polyurethane foam has many advantages over the more conventional templates. Refinements in flap design and surgical technique resulted in favorable functional and cosmetic results. Especially, for beginner, Polyurethane foam dressing material is a simple and safe tool and therefore is an excellent choice for design of the island flap.

  • PDF

Influence of Multiple Rib Fracture upon Traumatic Hemo-pneumothorax (다발성 늑골골절의 외상성 혈기흉 발생에 대한 영향)

  • Yang, Seung-Joon;Lee, Je-won;Jin, Sang-Chan;Joo, Myeong-Don;Choi, Woo-Ik
    • Journal of Trauma and Injury
    • /
    • v.21 no.2
    • /
    • pp.91-99
    • /
    • 2008
  • Purpose: Multiple rib fracture (MRF) and a hemopneumothorax accompany with most blunt chest traumas. We aimed to analyze the factors increasing the probability of a hemopneumothorax. In addition, other injuries accompanying MRF were analyzed. Methods: We retrospectively reviewed the medical records of 154 mutiple rib fracture patients who visited our hospital between January 2005 and December 2007. The medical records were reviewed for sex, age, mechanism of injury, location, number of fractures, distance of dislocated rib fragments, and presence of complications. We measured the distance of bony dislocations by using the PACS (Picture Archiving and Communication System). Results: The average number of rib fractures was $3.7{\pm}2.1$, and the number of rib fractures significantly influenced the incidence of a hemothorax (p<0.001). The risk of a hemothorax was increased in a bilateral MRF compared to a unilateral MRF (p=0.027). The distance of dislocated rib fragments influenced the probability of a hemothorax significantly (p=0.018), and subcutaneous emphysema and lung contusion were significantly associated with a pneumothorax (p=0.021, p=0.036). Conclusion: The number of MRFs did not influence the risk for a pneumothorax, but did influence the risk for a hemothorax. The laterality, distance of dislocation, also had an influence on the risk for a hemothorax. Also, subcutaneous emphysema and lung contusion were increased in cases with a pneumothorax. We must consider the possibility of a hemothorax even when the initial chest X-ray shows no evidence of a hemothorax. If a lung contusion is present, then an occult pneumothorax must be considered.