• 제목/요약/키워드: PA66

검색결과 149건 처리시간 0.032초

전기방사된 나일론66 나노웹의 열적·기계적 특성에 전자선 조사가 미치는 영향 (The Effects of Electron Beam Irradiation on Thermal and Mechanical Properties of Electrospun Nylon 66 Nano-web)

  • 전준표;강효경;강필현
    • 방사선산업학회지
    • /
    • 제5권1호
    • /
    • pp.69-73
    • /
    • 2011
  • Polyamide 66 (PA66) nanofibers with Triallyl cyanurate (TAC) were obtained by electrospinning of formic acid and chloroform solution. Electron beam irradiation of PA66 nanofiber with and without TAC was carried out over a range of absorbed doses (20~100 kGy) in nitrogen. The characterization of the irradiated PA66 nanofibers and PA66 nanofibers with TAC was done by scanning electron microscopy (SEM), nuclear magnetic resonance (NMR), thermogravimetric analysis (TGA) and universal testing machine (UTM). The results of the SEM image analysis confirmed that the morphology of PA66 nanofibers was not altered by electron beam. The amount of TAC in PA66 nanofiber with TAC was identified by $^1H-NMR$ analysis. The degradation temperature of PA66 nanofibers with TAC at an absorbed dose of 20~100 kGy was higher than the irradiated PA66 nanofiber without TAC. On the other hand, the decreasing rate of modulus of irradiated PA66 nanofibers with TAC was less than PA66 nanofibers.

Measurement of Degree of Hydrolysis of a PA66/GF Composite using a py-GC/MS analysis

  • Lee, Jong-Young;Kim, Kwang-Jea
    • Elastomers and Composites
    • /
    • 제52권1호
    • /
    • pp.59-68
    • /
    • 2017
  • The effect on the hydrolysis resistance properties by the addition of maleic anhydride grafted EMDM (MA-g-EPDM) and PP (MA-g-PP) to a PA66/GF composite was investigated with respect to the mechanical properties, thermal properties, and morphology. The degree of hydrolysis of the PA66/GF composite was measured using py-GC/MS analysis. When compared to the PA66/GFcomposite in MEG/water solution, the composites where MA-g-EPDM and MA-g-PP were added to PA66/GF showed a higher degree of hydrolysis resistance, impact strength, and thermal properties, whereas their tensile strength, tensile modulus, flexural strength and flexural modulus decreased. As immersion time in the solution increases, the rate of tensile strength drop of the MA-g-PP added composite appeared lower than that of the PA66/MA-g-EPDM/GF and PA66/GF composites. The py-GC/MS analysis confirmed the formation of PA66 hydrolysis reaction by products such as carboxylic acid and alkylamine with increasing immersion time.

Thermal Conductivity and Mechanical Properties of Magnesium Oxide Reinforced Polyamide-66 Composites

  • Hwang, Seok-Ho
    • Elastomers and Composites
    • /
    • 제50권3호
    • /
    • pp.205-209
    • /
    • 2015
  • Magnesium oxide (MgO) reinforced polyamide-66 (PA66) composites were prepared through melt-compounding method in order to determine the possibility of using MgO particle as conductive filler in the polymer-based composite. The effects of MgO filler content on the thermal conductivity and mechanical properties for the PA66/MgO composites were investigated. The results showed that the addition of MgO filler to the PA66 matrix led to a large increase in thermal conductivity of the PA66/MgO composites. Tensile strengths of the PA66/MgO composites were slightly decreased as MgO filler loading increased. However, flexural strength and flexural modulus were improved with increasing filler loading. Notched Izod impact strengths were dramatically lowered by the addition of MgO filler.

폴리아마이드 66/폴리프로필렌 블렌드의 상업화 연구 (A Study on the Commercialization of Polyamide 66/Polypropylene Blend)

  • 김석준;남병욱
    • Elastomers and Composites
    • /
    • 제38권3호
    • /
    • pp.262-272
    • /
    • 2003
  • 말레인산 무수물을 그라프트시킨 폴리프로필렌(PP-g-MA)을 폴리아마이드 66(PA 66)/PP-g-MA 이원 블렌드 및 PA 66/polypropylene(PP)/PP-g-MA 삼원블렌드에 한 성분 및 상용화제로 각각 사용하였다. 본 연구는 이원 및 삼원블렌드 사이의 여러가지 물성의 차이를 조사하는 것이다. 평가된 물성으로는 인장강도, 굴곡탄성율. 열변형온도, 충격강도, 용융흐름지수 그리고 전단속도 증가에 따른 점도변화가 포함된다. 이원 블렌드의 충격강도는 모든 조성에서 삼원 블렌드 보다 우수하였는데 이는 PA 66 말단의 아민 그룹과 PP-g-MA의 산 무수물이 반응하여 이미드(imide) 그룹이 형성되어 PP-g-PA 66 공중합체의 합성이 분자량을 증가시키고 이 반응이 삼원 블렌드에서 보다 이원 블렌드에 더 많이 일어나는 것에 기인하는 것이다. 삼원 블렌드계의 경우 대부분의 물성이 이원 블렌드 보다 우수하였는데 이는 PP의 물성이 PP-g-MA의 물성보다 우수하기 때문이다. 충격에 매우 강한 70/30(PA 66/pp-g-MA) 및 80/20 조성의 이원 블렌드는 가공성이 나빠 상업적 응용에는 불리하다. 따라서, 상업적 응용에는 낮은 용융점도를 보이는 삼원 블렌드를 사용하는 것이 추천된다.

저온 내충격성 향상을 위한 PA66/EPDM/PP 복합체 제조와 기계적 특성 연구 (A Study on the Manufacturing and Mechanical Properties of the PA66/EPDM/PP Composites for Enhanced Low Temperature Fracture Resistances)

  • 이태식;윤창록;방대석;안대영;계형산;신경철
    • Elastomers and Composites
    • /
    • 제44권2호
    • /
    • pp.164-174
    • /
    • 2009
  • 모듈라 치합형 동방향 이축 스크류식 압출기(modular intermeshing co-rotating twin screw extruder)를 이용하여 저온 내 충격성 향상을 위해 PA66/EPDM/PP-g-MA 및 PA66/EPDM-g-MA/PP-g-MA 복합체를 각 성분 wt%를 변화하여 제조하였다. 그 결과 이들 복합체 중에서 PA66/EPDM-g-MA/PP-g-MA의 wt%가 90/8/2인 복합체가 다른 복합체들 보다 열적, 기계적으로 우수한 결과를 나타내었다. 그리고 열중량분석기(Thermogravimetric Analysis), 시차주사열량계(Differential Scanning Calorimeter)를 이용하여 열적 특성, 주사 전자현미경(Scanning Electron Microcsopy)을 이용하여 형태학적 변화를 분석하였다. 본연구를 통하여 기존 PA66/EPDM composite의 단점인 낮은 계면력과 저온 내충격성을 향상 시켰으며, 최적의 mixing효과를 위한 screw configuration에 따른 압출 공정 확립과 PA66/EPDM composite 생산 공정 국산화 및 원가절감의 효과를 가져왔다.

Electrical Properties of CNT and Carbon Fiber Filled Hybrid Composites Based on PA66

  • Lee, Minji;Park, Se-Ho;Jhee, Kwang-Hwan;Kye, Hyoungsan;Bang, Daesuk
    • Elastomers and Composites
    • /
    • 제56권2호
    • /
    • pp.65-71
    • /
    • 2021
  • In recent times, the demand for electronic devices has increased because of advancements in the electronics industry. Consequently, research on shielding against electromagnetic interference (EMI) from electronic devices has also progressed significantly. In particular, research on imparting electrical conductivity to plastic has seen substantial progress. In this study, the effect of hybrid fillers comprising carbon fiber (CF) and carbon nanotubes (CNTs) on the electrical properties of polyamide 66 (PA66) composites was investigated. PA66 composites were prepared using a BUSS Co-Kneader single-screw extruder. EMI shielding effectiveness (SE) increased with the increasing addition of unsized CF (UCF), sized CF (SCF), and CNTs. For the PA66/SCF/CNT hybrid filler composites, EMI SE significantly increased with the increase in SCF content. Finally, the hybrid filler comprising SCF and CNTs may have a synergistic effect on the EMI SE and surface resistivity of PA66/SCF/CNT composites.

Hydrolysis Resistance and Mechanical Property Changes of Glass Fiber Filled Polyketone Composites Upon Glass Fiber Concentration

  • Kim, Sung Min;Kim, Kwang-Jea
    • Elastomers and Composites
    • /
    • 제52권1호
    • /
    • pp.1-8
    • /
    • 2017
  • Hydrolysis resistance and mechanical property changes of polyketone (POK)/glass fiber (GF) composites were investigated for GF concentrations varying between 30 and 50%. The hydrolysis resistance of GF filled POK and polyamide66 (PA66, hydrolysis resistant grade) composites were compared. As shown by the experimental results, increasing the immersion time of the composites in a monoethylene glycol (MEG)/water solution at $120^{\circ}C$ had no impact or resulted in slightly decreased mechanical properties such as the tensile strength, tensile modulus, and strain at break in case of POK composites, whereas the mechanical properties of PA66 composites showed a significant drop. Increasing GF concentrations increased the tensile strength, tensile modulus, flexural strength, and flexural modulus of POK composites; however, impact strength did not show significant changes. Hydrolysis mechanisms of POK and PA66 are discussed.

Mechanical Properties and Morphology of Polyamide/Polypropylene Blends

  • Kim, Su Young;Ha, Jin Uk;Shin, Donghyeok;Jung, Wooseok;Lee, Pyoung-Chan
    • Elastomers and Composites
    • /
    • 제55권1호
    • /
    • pp.1-5
    • /
    • 2020
  • This study examined the effects of the addition of maleic anhydride-grafted polypropylene (PP-g-MA) and polyolefin elastomer (POE) on polyamide 66 (PA66) and polypropylene (PP) blends. The blends of PA66/PP with PP-g-MA and POE were prepared using a twin screw extruder. Mechanical testing results revealed that the tensile, flexural, and izod impact strengths of the blends were maximized at a PP-g-MA content of 2 phr. The increased mechanical strength of the blends with PP-g-MA was attributed to the compatibilizing effect of the PA66 and PP blends. In addition, as the POE content increased, the impact strength of the blends increased. However, at a high POE content, the tensile and flexural strengths decreased, seemingly because of the lower mechanical properties of POE.

폴리아미드 66 복합소재의 열 열화 특성: 수명 예측과 활성화 에너지의 상관관계 (Characterization of Thermal Degradation of Polymide 66 Composite: Relationship between Lifetime Prediction and Activation Energy)

  • 정원영;원종일
    • 폴리머
    • /
    • 제36권6호
    • /
    • pp.712-720
    • /
    • 2012
  • 광학현미경분석, 주사전자현미경분석 및 적외선분광분석을 이용하여, 열화시간 경과에 따른 유리섬유가 보강된 폴리아미드 66 복합소재의 열 열화 특성을 조사하였다. 열화시간이 증가함에 따라, 인장강도는 열화 초기 약간의 증가 후 점진적으로 감소하는 경향을 보였다. 이러한 결과는 열 열화가 진행됨에 따라 결정화도의 증가, 가교밀도의 증가, 사슬 전단 및 사슬 운동성의 감소 등에 기인한 것으로 판단된다. 적외선분광분석을 통하여, 폴리아미드 66 복합소재 표면상에 열화에 기인한 케톤 피크와 규소 피크의 증가를 관찰하엿다. 또한 세 가지 승온속에서 측정된 열중량분석 결과를 이용하여 폴리아미드 66 복합소재으 열 분해 반응동역학을 분석하였다. 통계학적 기법, UL 746B, Ozawa 및 Kissinger 등 여러 방법을 통해 계산된, 폴리아미드 66 복합소재의 활성화 에너지와 수명 예측간의 상관관계를 조사하였다. 열중량분석으로부터 계산된 활성화 에너지는 가속시험으로 구한 값보다 상대적으로 큰 값을 나타내며, 이는 폴리아미드 66 소재으 수명을 과대 평가하는 결과를 초래하였다. 본 연구에서는 다양한 사용 온도에서의 활성화 에너지를 외삽하여 계산 가능한 지수 패턴의 표준곡선을 개발하였다.

Polyamide66/Polyphenylene 블렌드의 플라스마 표면처리를 통한 친수성 향상 (Hydrophilicity Improvement of Polyamide66/Polyphenylene Blends by Plasma Surface Treatment)

  • 지영연;김상식
    • 폴리머
    • /
    • 제30권5호
    • /
    • pp.391-396
    • /
    • 2006
  • 플라스마 표면처리는 접착력, 친수성, 소수성 등과 같은 고분자의 표면 특성을 개질시키기 위하여 사용되고 있다. 플라스마를 이용하여 표면을 처리하게 되면 고분자의 전체적인 물성은 유지한 채 표면의 특성만을 변화시키는 장점을 가지고 있다. 본 연구에서는 다양한 가스를 사용한 플라스마를 이용하여 상업용 Polyarlide66 (PA66) /polyphenylene(PPE) 고분자의 표면의 접착력 향상을 위해 표면 유기물 제거와 친수성으로 개질을 시도하였다. 플라스마 처리 공정 변수인 공정 파워, 처리 시간, 가스 종 들을 변화시키면서 표면을 개질하였으며 PASS/ PPE 고분자의 친수성 개질을 확인하기 위하여 접촉각 및 표면 자유에너지 변화를 측정하였다. 또한 유기물 제거를 FTIR 분석을 통하여 확인하였다. 플라스마를 이용한 표면처리 결과, 공정 파워 100 W, 처리 시간 2분, 아르곤/산소 공정가스에서 가장 낮은 접촉각(73도에서 14도)과 가장 높은 표면 자유에너지 ($44.20 mJ/m^2$에서 $50.03 mJ/m^2$)를 나타내었다.