• Title/Summary/Keyword: PA Attack

Search Result 15, Processing Time 0.021 seconds

Characteristics of AlW thin film for TFT-FCD bus line

  • Kim, Dong-Sik;Yi, Chong-Ho;Chung, Kwan-Soo
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2000.02a
    • /
    • pp.58-58
    • /
    • 2000
  • Recently low resistance of bus line is required for large screen size RFT-CLD panels. As a result, lower resistance Al-alloy is currently reviewed extensively. The resistivity is required smaller than 10$\mu$$\Omega$cm and high resistance of chemical attack is required. In this paper, Al-W thin film were deposited on glass substrates by D.C magnetron sputtering system under various condition for high chemical resistance. Its properties were characterized by SEM, AFM, XRD, 4-point-probe, and cyclic voltammertry. The optimal condition of Al-W was 10$0^{\circ}C$, 100W, 0.4Pa, 23sccm(Ar) and 35$0^{\circ}C$, 20min. annealing. At that condition the resistivity of Al-W(3 wt.%) was about 11$\mu$$\Omega$cm. And when wt.% of W in Al-W alloy was higher than about 4%, Al-W alloy thin film has high chemical resistance.

  • PDF

A Case Study of WRF Simulation for Surface Maximum Wind Speed Estimation When the Typhoon Attack : Typhoons RUSA and MAEMI (태풍 내습 시 지상 최대풍 추정을 위한 WRF 수치모의 사례 연구 : 태풍 RUSA와 MAEMI를 대상으로)

  • Jung, Woo-Sik;Park, Jong-Kil;Kim, Eun-Byul;Lee, Bo-Ram
    • Journal of Environmental Science International
    • /
    • v.21 no.4
    • /
    • pp.517-533
    • /
    • 2012
  • This study calculated wind speed at the height of 10 m using a disaster prediction model(Florida Public Hurricane Loss Model, FPHLM) that was developed and used in the United States. Using its distributions, a usable information of surface wind was produced for the purpose of disaster prevention when the typhoon attack. The advanced research version of the WRF (Weather Research and Forecasting) was used in this study, and two domains focusing on South Korea were determined through two-way nesting. A horizontal time series and vertical profile analysis were carried out to examine whether the model provided a resonable simulation, and the meteorological factors, including potential temperature, generally showed the similar distribution with observational data. We determined through comparison of observations that data taken at 700 hPa and used as input data to calculate wind speed at the height of 10 m for the actual terrain was suitable for the simulation. Using these results, the wind speed at the height of 10 m for the actual terrain was calculated and its distributions were shown. Thus, a stronger wind occurred in coastal areas compared to inland areas showing that coastal areas are more vulnerable to strong winds.

A novel power trace aligning method for power analysis attacks in mobile devices (모바일 기기에서의 전력 분석 공격을 위한 새로운 전력 신호 정렬 방법)

  • Lee, Yu-Ri;Kim, Wan-Jin;Lee, Young-Jun;Kim, Hyoung-Nam
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.21 no.1
    • /
    • pp.153-166
    • /
    • 2011
  • Recent trends in mobile device market whose services are rapidly expanding to provide wireless internet access are drawing people's attention to mobile security. Especially, since threats to information leakage are reaching to the critical level due to the frequent interchange of important data such as personal and financial information through wireless internet, various encryption algorithms has been developed to protect them. The encryption algorithms confront the serious threats by the appearance of side channel attack (SCA) which uses the physical leakage information such as timing, and power consumption, though the their robustness to threats is theoretically verified. Against the threats of SCA, researches including the performance and development direction of SCA should precede. Among tile SCA methods, the power analysis (PA) attack overcome this misalignment problem. The conventional methods require large computational power and they do not effectively deal with the delay changes in a power trace. To overcome the limitation of the conventional methods, we proposed a novel alignment method using peak matching. By computer simulations, we show the advantages of the proposed method compared to the conventional alignment methods.

A Study on Mechanical Characteristic of Hydrogen Charged Al-6.3Zn-2.4Mg Alloy (Al-6.3Zn-2.4Mg 합금의 수소충전에 따른 기계적 특성 연구)

  • Kim, Dae-Hwan;Choi, Tae-Young;Shim, Sung-Young;Lim, Su-Gun
    • Journal of Korea Foundry Society
    • /
    • v.34 no.2
    • /
    • pp.54-59
    • /
    • 2014
  • In this study, the extruded Al-6.3Zn-2.4Mg alloys were selected among the 7000 series aluminum alloys sensitive to hydrogen environment in order to examine the effects of both the aging conditions and the length of hydrogen charging period on the mechanical properties of the alloy. The specimens were aged for 24hours at $100^{\circ}C$ (under aging (UA)), $120^{\circ}C$ (peak aging (PA)), and $160^{\circ}C$ (over aging (OA)), respectively. Charging tests were performed at RT for 12, 24, 36 hours under potentiostatic conditions (-2000 mV vs (Ag/AgCl)) for 12, 24 and 36 hours in 1M $H_2SO_4$ and 0.1%$NH_4SCN$ solution. The fracture surface was examined by scanning electron microscopy (SEM). X-ray diffraction (XRD) pattern in peak aged sample was obtained before and after hydrogen charging from extruded Al-6.3Zn-2.4Mg alloys. The decreasing rate of tensile strength and elongation is represented in order of over aging < under aging < peak aging, and it is believed that the hydrogen recharge is more sensitive to elongation than tensile strength. The formation of $AlH_3$ in hydrogen charged Al-6.3Zn-2.4Mg alloys has been confirmed by X-ray diffraction studies.

An Estimation of Amount of Damage Using the 3-second Gust When the Typhoon Attack (태풍 내습 시 3-second gust를 이용한 피해액 산정)

  • Jung, Woo-Sik;Park, Jong-Kil;Choi, Hyo-Jin
    • Journal of Environmental Science International
    • /
    • v.19 no.3
    • /
    • pp.353-363
    • /
    • 2010
  • The most efficient measures to reduce damage from natural disasters include activities which prevent disasters in advance, decrease possibility of disasters and minimize the scale of damage. Therefore, developing of the risk assessment model is very important to reduce the natural disaster damage. This study estimated a typhoon damage which is the biggest damage scale among increased natural disasters in Korea along with climate change. The results of 3-second gust at the height of 10m level from the typhoon 'Maemi' which did considerable damage to Korean in 2003, using the wind data at the height of 700 hPa. September 12th 09 LST~13th 12 LST period by the time a typhoon Maemi approached to the Korean peninsula. This study estimate damage amount using 'Fragility curve' which is the damage probability curve about a certain wind speed of the each building component factors based on wind load estimation results by using 3-second gust. But the fragility curve is not to Korea. Therefore, we use the fragility curves to FPHLM(FDFS, 2005). The result of houses damage amount is about 11 trillion 5 million won. This values are limit the 1-story detached dwelling, $62.51\sim95.56\;m^2$ of total area. Therefore, this process is possible application to other type houses.