• Title/Summary/Keyword: P-median algorithm

Search Result 26, Processing Time 0.02 seconds

A Study on Salt & Pepper Noise Removal using the Pixel Distribution of Local Mask (국부 마스크의 화소 분포를 이용한 Salt & Pepper 잡음 제거에 관한 연구)

  • Kwon, Se-Ik;Kim, Nam-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.9
    • /
    • pp.2167-2172
    • /
    • 2015
  • Due to the recent progress in information technology, demand for video imaging devices such as displays has grown. In general, images experience deterioration during the process of transmission due to various reasons. Many studies have boon undertaken on ways o reduce such noise. This paper6 suggests an algorithm that makes a judgment on the noise in order to remove the salt & pepper noise and replaces original pixels if they are non-noise while processing noise according to its density. The suggested algorithm shows a high PSNR of 30.49[dB] for Goldhill images that had been damaged of a high density salt & pepper noise(P = 60%), Compared to the exising CWMF, SWMF, and A-TMF, there were improvements by 17.74[dB], 11.52[dB], and 13.76[dB], respectively.

Comparison of the Quality of Various Polychromatic and Monochromatic Dual-Energy CT Images with or without a Metal Artifact Reduction Algorithm to Evaluate Total Knee Arthroplasty

  • Hye Jung Choo;Sun Joo Lee;Dong Wook Kim;Yoo Jin Lee;Jin Wook Baek;Ji-yeon Han;Young Jin Heo
    • Korean Journal of Radiology
    • /
    • v.22 no.8
    • /
    • pp.1341-1351
    • /
    • 2021
  • Objective: To compare the quality of various polychromatic and monochromatic images with or without using an iterative metal artifact reduction algorithm (iMAR) obtained from a dual-energy computed tomography (CT) to evaluate total knee arthroplasty. Materials and Methods: We included 58 patients (28 male and 30 female; mean age [range], 71.4 [61-83] years) who underwent 74 knee examinations after total knee arthroplasty using dual-energy CT. CT image sets consisted of polychromatic image sets that linearly blended 80 kVp and tin-filtered 140 kVp using weighting factors of 0.4, 0, and -0.3, and monochromatic images at 130, 150, 170, and 190 keV. These image sets were obtained with and without applying iMAR, creating a total of 14 image sets. Two readers qualitatively ranked the image quality (1 [lowest quality] through 14 [highest quality]). Volumes of high- and low-density artifacts and contrast-to-noise ratios (CNRs) between the bone and fat tissue were quantitatively measured in a subset of 25 knees unaffected by metal artifacts. Results: iMAR-applied, polychromatic images using weighting factors of -0.3 and 0.0 (P-0.3i and P0.0i, respectively) showed the highest image-quality rank scores (median of 14 for both by one reader and 13 and 14, respectively, by the other reader; p < 0.001). All iMAR-applied image series showed higher rank scores than the iMAR-unapplied ones. The smallest volumes of low-density artifacts were found in P-0.3i, P0.0i, and iMAR-applied monochromatic images at 130 keV. The smallest volumes of high-density artifacts were noted in P-0.3i. The CNRs were best in polychromatic images using a weighting factor of 0.4 with or without iMAR application, followed by polychromatic images using a weighting factor of 0.0 with or without iMAR application. Conclusion: Polychromatic images combined with iMAR application, P-0.3i and P0.0i, provided better image qualities and substantial metal artifact reduction compared with other image sets.

Comparison of cardiac arrests from sport & leisure activities with patients returning of spontaneous circulation using Answer Tree analysis (의사결정나무분석에 의한 스포츠 레저활동 심정지군과 자발순환 회복군의 비교)

  • Park, Sang-Kyu;Uhm, Tai-Hwan
    • The Korean Journal of Emergency Medical Services
    • /
    • v.15 no.3
    • /
    • pp.57-70
    • /
    • 2011
  • Purpose : The purpose of this study was to reveal some factors of ROSC & survival for cardiac arrests from sport & leisure activities(CASLs). Methods : A retrospective study of the 1,341 out of hospital cardiac arrests(OHCAs) treated by EMS in Gyeonggi Provincial Fire and Disaster Headquarters from January to December in 2008 was conducted. The primary end-point was admission to emergency room. To clarify the factors through comparison of CASLs(n=58) with ROSCs & survivals(n=58), Answer Tree analysis for data mining with the CHAID algorithm was performed and alpha was set at .05. Mean, median, and percentile of time intervals, distances, and age on the 58 CASLs, 75 ROSCs, and 27 survivals(patients admitted to emergency room) were analysed. Results : Fourteen CASLs(24.1%), 41 ROSCs(54.7%), 16 survivals(59.3%) were treated with CPR within 5 min., and only 2 CASLs(3.4%), 11 ROSCs(14.7%), 10 survivals(37.0%) were treated with defilbrillation within 10 min. from arrest. If time recording from arrest to defilbrillation, the patients were classified 81.0%($X^2=9.83$, p=.005) into ROSCs & survivals. And the patients with no history, 100.0%($X^2=5.44$, p=.020). The other patients with no intention, 87.5%($X^2=7.00$, p=.024). Whereas the other patients with intention, treated with CPR after 4 min. from arrest were classified 67.2%($X^2=3.99$, p=.046) into CASLs. Conclusion : CPR within 4 minutes was the most important factor that discriminates between CASLs and ROSCs & survivals to record cardiac arrests-defilbrillation time. CPR within 4 min. from arrest, no history, and no intention were factors for improved ROSC & survival.

Deep Learning Algorithm for Simultaneous Noise Reduction and Edge Sharpening in Low-Dose CT Images: A Pilot Study Using Lumbar Spine CT

  • Hyunjung Yeoh;Sung Hwan Hong;Chulkyun Ahn;Ja-Young Choi;Hee-Dong Chae;Hye Jin Yoo;Jong Hyo Kim
    • Korean Journal of Radiology
    • /
    • v.22 no.11
    • /
    • pp.1850-1857
    • /
    • 2021
  • Objective: The purpose of this study was to assess whether a deep learning (DL) algorithm could enable simultaneous noise reduction and edge sharpening in low-dose lumbar spine CT. Materials and Methods: This retrospective study included 52 patients (26 male and 26 female; median age, 60.5 years) who had undergone CT-guided lumbar bone biopsy between October 2015 and April 2020. Initial 100-mAs survey images and 50-mAs intraprocedural images were reconstructed by filtered back projection. Denoising was performed using a vendor-agnostic DL model (ClariCT.AITM, ClariPI) for the 50-mAS images, and the 50-mAs, denoised 50-mAs, and 100-mAs CT images were compared. Noise, signal-to-noise ratio (SNR), and edge rise distance (ERD) for image sharpness were measured. The data were summarized as the mean ± standard deviation for these parameters. Two musculoskeletal radiologists assessed the visibility of the normal anatomical structures. Results: Noise was lower in the denoised 50-mAs images (36.38 ± 7.03 Hounsfield unit [HU]) than the 50-mAs (93.33 ± 25.36 HU) and 100-mAs (63.33 ± 16.09 HU) images (p < 0.001). The SNRs for the images in descending order were as follows: denoised 50-mAs (1.46 ± 0.54), 100-mAs (0.99 ± 0.34), and 50-mAs (0.58 ± 0.18) images (p < 0.001). The denoised 50-mAs images had better edge sharpness than the 100-mAs images at the vertebral body (ERD; 0.94 ± 0.2 mm vs. 1.05 ± 0.24 mm, p = 0.036) and the psoas (ERD; 0.42 ± 0.09 mm vs. 0.50 ± 0.12 mm, p = 0.002). The denoised 50-mAs images significantly improved the visualization of the normal anatomical structures (p < 0.001). Conclusion: DL-based reconstruction may enable simultaneous noise reduction and improvement in image quality with the preservation of edge sharpness on low-dose lumbar spine CT. Investigations on further radiation dose reduction and the clinical applicability of this technique are warranted.

Prediction of Decompensation and Death in Advanced Chronic Liver Disease Using Deep Learning Analysis of Gadoxetic Acid-Enhanced MRI

  • Subin Heo;Seung Soo Lee;So Yeon Kim;Young-Suk Lim;Hyo Jung Park;Jee Seok Yoon;Heung-Il Suk;Yu Sub Sung;Bumwoo Park;Ji Sung Lee
    • Korean Journal of Radiology
    • /
    • v.23 no.12
    • /
    • pp.1269-1280
    • /
    • 2022
  • Objective: This study aimed to evaluate the usefulness of quantitative indices obtained from deep learning analysis of gadoxetic acid-enhanced hepatobiliary phase (HBP) MRI and their longitudinal changes in predicting decompensation and death in patients with advanced chronic liver disease (ACLD). Materials and Methods: We included patients who underwent baseline and 1-year follow-up MRI from a prospective cohort that underwent gadoxetic acid-enhanced MRI for hepatocellular carcinoma surveillance between November 2011 and August 2012 at a tertiary medical center. Baseline liver condition was categorized as non-ACLD, compensated ACLD, and decompensated ACLD. The liver-to-spleen signal intensity ratio (LS-SIR) and liver-to-spleen volume ratio (LS-VR) were automatically measured on the HBP images using a deep learning algorithm, and their percentage changes at the 1-year follow-up (ΔLS-SIR and ΔLS-VR) were calculated. The associations of the MRI indices with hepatic decompensation and a composite endpoint of liver-related death or transplantation were evaluated using a competing risk analysis with multivariable Fine and Gray regression models, including baseline parameters alone and both baseline and follow-up parameters. Results: Our study included 280 patients (153 male; mean age ± standard deviation, 57 ± 7.95 years) with non-ACLD, compensated ACLD, and decompensated ACLD in 32, 186, and 62 patients, respectively. Patients were followed for 11-117 months (median, 104 months). In patients with compensated ACLD, baseline LS-SIR (sub-distribution hazard ratio [sHR], 0.81; p = 0.034) and LS-VR (sHR, 0.71; p = 0.01) were independently associated with hepatic decompensation. The ΔLS-VR (sHR, 0.54; p = 0.002) was predictive of hepatic decompensation after adjusting for baseline variables. ΔLS-VR was an independent predictor of liver-related death or transplantation in patients with compensated ACLD (sHR, 0.46; p = 0.026) and decompensated ACLD (sHR, 0.61; p = 0.023). Conclusion: MRI indices automatically derived from the deep learning analysis of gadoxetic acid-enhanced HBP MRI can be used as prognostic markers in patients with ACLD.

Global Left Ventricular Myocardial Work Efficiency in Patients With Severe Rheumatic Mitral Stenosis and Preserved Left Ventricular Ejection Fraction

  • Estu Rudiktyo;Amiliana M Soesanto;Maarten J Cramer;Emir Yonas;Arco J Teske;Bambang B Siswanto;Pieter A Doevendans
    • Journal of Cardiovascular Imaging
    • /
    • v.31 no.4
    • /
    • pp.191-199
    • /
    • 2023
  • BACKGROUND: Assessment of left ventricular (LV) function plays a pivotal role in the management of patients with valvular heart disease, including those caused by rheumatic heart disease. Noninvasive LV pressure-strain loop analysis is emerging as a new echocardiographic method to evaluate global LV systolic function, integrating longitudinal strain by speckle-tracking analysis and noninvasively measured blood pressure to estimate myocardial work. The aim of this study was to characterize global LV myocardial work efficiency in patients with severe rheumatic mitral stenosis (MS) with preserved ejection fraction (EF). METHODS: We retrospectively included adult patients with severe rheumatic MS with preserved EF (> 50%) and sinus rhythm. Healthy individuals without structural heart disease were included as a control group. Global LV myocardial work efficiency was estimated with a proprietary algorithm from speckle-tracking strain analyses, as well as noninvasive blood pressure measurements. RESULTS: A total of 45 individuals with isolated severe rheumatic MS with sinus rhythm and 45 healthy individuals were included. In healthy individuals without structural heart disease, the mean global LV myocardial work efficiency was 96% (standard deviation [SD], 2), Compared with healthy individuals, median global LV myocardial work efficiency was significantly worse in MS patients (89%; SD, 4; p < 0.001) although the LVEF was similar. CONCLUSIONS: Individuals with isolated severe rheumatic MS and preserved EF, had global LV myocardial work efficiencies lower than normal controls.