• Title/Summary/Keyword: P-M 상관 곡선

Search Result 59, Processing Time 0.033 seconds

Structure and physical properties of Earth Crust material in the Middle of Korean Peninsula(2) : Comparison between elastic Velocity and point-load of core specimen of sedimentary rocks. (한반도 중부권 지각물질의 구조와 물성연구(2) : 퇴적암류 코아시료의 탄성파 속도와 점재하 강도 비교)

  • 송무영;황인선
    • The Journal of Engineering Geology
    • /
    • v.3 no.1
    • /
    • pp.21-37
    • /
    • 1993
  • In order to investigate the correlation of sedimentary rock properties. specific gravity, porosity, water content, sonic wave velodty, and point4oad strength index of core samples of limestones, sandstones and shales were measured. The relationships between density and velocity show $V_p=16300d-38719.3,{\;}V_s1896.4d-29225.1$ of regression equation for sandstones and $Vp=4085d-10264.8,{\;}V_s=3519d-7841.3$ for shales and <$Vp=4085d^2-20747d+303,{\;}V_s=3899d^2-21442d+318$ for limestones. Seismic wave velocity of shales which have high density is lower than that of sandstones, and this seems to be an effect of bedding in shale. P-wave velocity and S-wave velocity of limestones, sandstones and shales show the linear relationships as a whole. The regression equations are respectively calculated V_s=0.26V_p+1041.6m/sec,{\;}V_s=0.43V_p+424.2m/sec,{\;}and{\;}Vs=0.51V_p+261.9m/sec$ and the correlation coefficients of the velocity show r= 0.86 in sandstones, r= 0.75 in limestones and r=0.86 in shales. According to the point4oad strength test for limestones, point4ord strength anisotropy was not so dear even though the specimens show generally the banded structure. Variations of dip angle of bedding whihin the range $30^{\circ}-60^{\circ}$ does not have much influence upon the diametral strength index and axial strength index. From the result of point load test, P-wave velocity increases with point4ord strength index but the regression equations are $V_p=98.5lI{s_d}+4082.1m/sec,{\;}V_p=106.41{s_a}+3954m/sec$ and their correlation coefficient is low.

  • PDF

Correlations Between Height and Forced Expiratory Flow Curve Parameters (신장과 노력성 호기곡선 지표간의 상관성)

  • Jin, Bok Hee;Park, Sun Young;Park, Hyea Lim
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.36 no.2
    • /
    • pp.199-204
    • /
    • 2004
  • Height has become one of the most important factors to determine the pulmonary function test index, and there is a high correlation between them, so that they have been utilized for evaluating pulmonary function test predictive value or nomogram. Therefore, we have tried to find out that difference and if there is any correlation and linear relationship between height and forced expiratory flow curve. There were a total of 163 subjects, male 93 and female 70. This study was done at the Department of Pulmonary Function Test of Jeon-Ju Presbyterian Hospital and we measured the index at the forced expiratory flow curve of FVC, $FEV_{1.0}$, $FEV_{1.0}$/FVC, $FEF_{25-75%}$, and $FEF_{200-1200m{\ell}}$. When we subjected the group of height more than 160cm, there were gradual increments at FVC(p<0.001), $FEV_{1.0}$(p<0.001), $FEF_{25-75%}$(p<0.05) and $FEF_{200-1200m{\ell}}$(p<0.001), but no changes at $FEV_{1.0}$/FVC in terms of forced expiratory flow curve index. We have analyzed the relationship between height and forced expiratory flow curve, there was a close relationship at FVC(r=0.670, p<0.01), $FEV_{1.0}$(r=0.491, p<0.01), $FEF_{25-75%}$ (r=0.175, p<0.05) and $FEF_{200-1200m{\ell}}$(r=0.370, p<0.01) but there was reciprocal relationship at $FEV_{1.0}$/FVC(r=-0.215, p<0.01). We have tried simple regression analysis to see if height affects forced expiratory flow curve index as a sector, and the result was $FVC(\ell)=0.0642{\times}height(cm)-7.2978$(p<0.01, $R^2=0.449$), $FEV_{1.0}(\ell)=0.0407{\times}height(cm)-4.2774$ (p<0.01, $R^2=0.2411$), $FEV_{1.0}/FVC(%)=-0.2892{\times}height(cm)+121.44$(p<0.01, $R^2=0.0464$), $FEF_{25-75%}(\ell/sec)=0.0176{\times}height(cm)-0.7876$(p<0.05, $R^2=0.0237$), $FEF_{200-1200m{\ell}}(\ell/sec)=0.0967{\times}height(cm)-11.037$(p<0.01, $R^2=0.1214$) this was approved statistically. According to this study, if height is taller than average, forced expiratory flow curve index were increased, there was a close relationship between height and forced expiratory flow curve, and there was a linear relationship as sector between height and forced expiratory flow curve index. Therefore, researches that study other factors such as sex, age, weight, body surface area, and obesity indexes other than height should be done to see if there are any further relationships.

  • PDF

Analysis of Cast Iron by Glow Discharge Emission Spectrometry (글로우 방전/방출분광분석법에 의한 주철시료의 분석)

  • Cho, K.H.;Woo, J.C.;Han, M.S.
    • Analytical Science and Technology
    • /
    • v.6 no.3
    • /
    • pp.297-305
    • /
    • 1993
  • Generally, it is difficult to analyze cast iron samples with spark discharge emission spectrometry since the content of carbon in these samples is high as a few percent. The cast iron samples were analyzed with the developed glow discharge emission spectrometer composed of glow discharge emission source and polychromator. The discharge condition of glow discharge lamp(GDL) has been optimized by variation of Ar gas pressure, discharge voltage and discharge time. Under the optimum conditions obtained in this work, relationships between the measured emission intensities and concentration of two types of cast iron standard samples(BAS, LECO) were investigated. Most of elements(Mn, Si, P, S etc.) showed the good linearity in one calibration curve. And the carbon showed slightly the systematic difference according to the type of standard samples.

  • PDF

Spectrofluorimetric Determination of Pb ion in Aqueous Media Using an Optical Sensor (광센서를 이용한 수용액 중 납이온의 형광분광법적 정량)

  • Lee, Sang Hak;Seo, Hyo Suk
    • Journal of the Korean Chemical Society
    • /
    • v.46 no.5
    • /
    • pp.407-411
    • /
    • 2002
  • A method to determine lead ion in aqueous media using an optical sensor loaded on a fluorescent optode membrane incoporating a metal ion-selective ionophore, a proton-selective chromoionophore and lipophilic anionic sites has been studied. The effects of pH and thickness of membrane on the fluorescence intensity were investigated. The effects of foreign ions such as $Na^+$, $K^+$, $Mn^{2+}$ and $Zn^{2+}$ on the determination of lead ion were also studied. The linear range in the calibration curve for the determination of lead ion was found to be 5.0${\times}10^-7$ to 5.0${\times}$$10^-3$M and the correlation coefficient in this range was -0.99107 under the optimal experimental conditions. The relative standard deviation of the blank signals was 3.0% and the detection limit of lead ion was 5.0${\times}$$10^-9$M.

Extraction-Spectrophotometric Determination of Cimetidine in Pharmaceutical Samples as an Ion Pair with Bromothymol Blue (티몰블루와 함께 이온쌍으로서 약제 샘플에서 시메티딘의 추출-분광광도 측정)

  • Zargar, B.;Pourreza, N.;Shahrouz, M.
    • Journal of the Korean Chemical Society
    • /
    • v.55 no.1
    • /
    • pp.46-49
    • /
    • 2011
  • A highly sensitive and selective extraction-spectrophotometric method has been developed for determination of trace amounts of cimetidine. This method is based on the extraction of cimetidine as an ion pair with bromothymol blue (BTB) into chloroform and measuring its absorbance at 417 nm. The effect of different variables such as pH, concentration of BTB, volume of chloroform and shaking time was investigated. The effect of interfering ions on the extraction was also studied. The calibration curve was linear in the range of 0.25-8 ${\mu}gmL^{-1}$ with correlation coefficient of 0.9997. The detection limit based on 3Sb was 0.14 ${\mu}gmL^{-1}$ and relative standard deviation for 10 replicated measurements of 1.0 and 4.0 ${\mu}gmL^{-1}$ of cimetidine was 3.2 and 1.49%, respectively. The proposed method was applied to the determination of cimetidine in pharmaceutical samples with good recoveries.

Development and Assessment Individual Maximum Permissible Dose Method of I-131 Therapy in High Risk Patients with Differentiated Papillary Thyroid Cancer (물리학 선량법을 이용한 갑상선암의 개인별 최대안전용량 I-131 치료법 개발과 유용성 평가)

  • Kim, Jeong-Chul;Yoon, Jung-Han;Bom, Hee-Seung;JaeGal, Young-Jong;Song, Ho-Chun;Min, Jung-Joon;Jeong, Heong;Kim, Seong-Min;Heo, Young-Jun;Li, Ming-Hao;Park, Young-Kyu;Chung, June-Key
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.2
    • /
    • pp.110-119
    • /
    • 2003
  • Purpose: Radioiodine (I-131) therapy is an effective modality to reduce both recurrence and mortality rates in differentiated thyroid cancer. Whether higher doses shows higher therapeutic responses was still debatable. The purpose of this study was to validate curve-fitting (CF) method measuring maximum permissible dose (MPD) by a biological dosimetry using metaphase analysis of peripheral blood lymphocytes. Materials and Methods: Therapeutic effects of MPD was evaluated in 58 patients (49 females and 9 males, mean age $50{\pm}11$ years) of papillary thyroid cancer. Among them 43 patients were treated with ${\Leq}7.4GBq$, while 15 patients with ${\geq}9.25GBq$. The former was defined as low-dose group, and the latter high-dose group. Therapeutic response was defined as complete response when complete disappearance of lesions on follow-up I-131 scan and undetectable serum thyroglobulin levels were found. Statistical comparison between groups were done using chi-square test. P value less than 0.05 was regarded as statistically significant. Results: MPD measured by CF method using tracer and therapeutic doses were $13.3{\pm}1.9\;and\;13.8{\pm}2.1GBq$, respectively (p=0.20). They showed a significant correlation (r=0.8, p<0.0001). Exposed doses to blood measured by CF and biological methods were $1.54{\pm}0.03\;and\;1.78{\pm}0.03Gy$ (p=0.01). They also showed a significant correlation (r=0.86, p=0.01). High-dose group showed a significantly higher rate of complete response (12/15, 80%) as compared to the low-dose group (22/43, 51.2%) (p=0.05). While occurrence of side effects was not different between two groups (40% vs. 30.2%, p=0.46). Conclusion: Measurement of MPD using CF method is reliable, and the high-dose I-131 therapy using MPD gains significantly higher therapeutic effects as compared with low-dose therapy.

Determination of Trace Amounts of Zirconium by Flotation - Spectrophotometric Method (부유 - 분광광도법에 의한 지르코늄의 극미량 측정)

  • Pourreza, N.;Parham, H.;Shiri, S.
    • Journal of the Korean Chemical Society
    • /
    • v.54 no.3
    • /
    • pp.283-286
    • /
    • 2010
  • A sensitive and reproducible method for the flotation-spectrophotometric determination of zirconium is reported. The method is based on the complex formation zirconium and xylenol orange (XO) which is floated in the interface of aqueous phase and n-hexane by vigorous shaking. By discarding the aqueous solution and n-hexane, the adsorbed complex on to the wall of a separating funnel was dissolved in a small volume of methanol solvent and its absorbance was measured at 429 nm. The effect of different parameters such as pH, concentrations of HCl, and XO, and volume of n-hexane flotation dissolvent, standing and shaking time were studied. The calibration curve was linear in the range of 7-120 ng $mL^{-1}$ of zirconium with a correlation coefficient of 0.9991. The limit of detection (LOD) was 5.8 ng $mL^{-1}$. The relative standard deviation (RSD) for seven replicate measurements of 50 and 110 ng $mL^{-1}$ of zirconium were 4.4 and 3.0%, respectively. The method was successfully applied to the determination of zirconium in water samples.

A Study on the Reduction of Non-Point Source Pollution loads from Small Agricultural Watershed by Applying Surface Covering Scenario using HSPF Model (HSPF 모델을 이용한 지표피복 시나리오 적용에 따른 농촌 소유역에서의 비점원오염 저감연구)

  • Jung, Chung-Gil;Park, Jong-Yoon;Kim, Sang-Ho;Kim, Seong-Joon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.103-103
    • /
    • 2012
  • 본 연구에서는 시험포장($1276.6m^2$)에서의 지표피복 BMPs (Best Management Practices) 시나리오를 적용하여 얻은 평균 유출저감율을 HSPF 모델에 적용하여 유역차원에서의 비점원오염 저감효과를 평가하고자 한다. 본 연구에서는 별미천 유역($1.21km^2$)을 대상으로 모형의 적용을 위한 입력자료로 기상자료와 지형자료를 구축하였으며 기상자료로 수원, 양평, 이천 기상관측소 자료를 구축하였으며, 지형자료로 격자크기 2m의 DEM (Digital Elevation Model)과 토지이용도는 2006년 5월 1일 QuickBird 영상을 제공받아 기존 환경부, 건교부, USGS의 토지피복분류체계 및 현장조사를 통하여 QuickBird 영상으로부터 추출 가능한 정밀농업정보에 대한 항목을 결정하였으며, 정사보정된 QuickBird 영상을 스크린 디지타이징 기법(On-Screen Digitizing Method)을 이용하여 총 21개 토지이용항목의 정밀토지이용도를 구축하였다. 실제모니터링으로 측정된 자료를 바탕으로 수위-유량곡선 산정 및 오염부하곡선을 선정, 2011년 6월 8일부터 10월 31일 분석기간으로 HSPF 모델링을 실시하였으며 모의결과 월별 통계에 따른 적용성 분석으로 RMSE (Root Mean Square Error) 는 1.15 ~ 1.76(mm/day), $R^2$는 0.62 ~ 0.78, Nash-Sutcliffe model efficiency (NSE)는 0.62 ~ 0.76로 모의치는 실측치와 유의성이 있는 것으로 분석되었다. 또한, Sediment, T-N, T-P의 $R^2$는 각각 0.72, 0.62, 0.63으로 상관성을 보이는 것으로 분석되었다. 시험포장으로부터 얻어진 event별 볏짚을 이용한 지표피복시나리오적용 후 밭에서의 평균 유출 약 10 % 유출율 감소 조건과 실제 평균 비점원오염 저감효과 89.7 % ~ 99.4 %의 결과로부터 지표피복효과의 침투효과를 HSPF 모델로 적용하기 위해 침투량(INFILT)를 조절하여 평균유출 약 10 %가 감소되는 16.0 mm/hr 값을 선정하였다. 그 결과, Sediment. T-N, T-P의 평균 저감율은 각각 87.2 %, 28.5 %, 85.1 %로 나타났으며 이는 시험포장에서의 실제 평균 비점오염 저감효과 89.7 % ~ 99.4 %에 근접함을 알 수 있었다. 이 결과로부터 침투량 조절에 따른 지표피복(침투짚단)효과는 Sediment, T-P에서 저감효율이 80 % 이상으로 높았지만 T-N은 약 30 %로 낮은 저감율을 보임으로써 저감효과가 크지 않음을 나타냈다.

  • PDF

Improvement in Regional Contractility of Myocardium after CABG (관상동맥 우회로 수술 환자에서 심근의 탄성도 변화)

  • Lee, Byeong-Il;Paeng, Jin-Chul;Lee, Dong-Soo;Lee, Jae-Sung;Chung, June-Key;Lee, Myung-Chul;Choi, Heung-Kook
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.4
    • /
    • pp.224-230
    • /
    • 2005
  • Purpose: The maximal elastance ($E_{max}$) of myocardium has been established as a reliable load-independent contractility index. Recently, we developed a noninvasive method to measure the regional contractility using gated myocardial SPECT and arterial tonometry data. In this study, we measured regional $E_{max}(rE_{max}$ in the patients who underwent coronary artery bypass graft surgery (CABG), and assessed its relationship with other variables. Materials and Methods: 21 patients (M:F=17:4, $58{\pm}12$ y) who underwent CABG were enrolled. $^{201}TI$ rest/dipyridamole stress $^{99m}Tc$-sestamibi gated SPECT were performed before and 3 months after CABG. For 15 myocardial regions, regional time-elastance curve was obtained using the pressure data of tonometry and the volume data of gated SPECT. To investigate the coupling with myocardial function, preoperative regional $E_{max}$ was compared with regional perfusion and systolic thickening. In addition, the correlation between $E_{max}$ and viability was assessed in dysfunctional segments (thickening <20% before CABG). The viability was defined as improvement of postoperative systolic thickening more than 10%. Results: Regional $E_{max}$ was slightly increased after CABG from $2.41{\pm}1.64 (pre)\;to\;2.78{\pm}1.83 (post)$ mmHg/ml. $E_{max}$ had weak correlation with perfusion and thickening (r=0.35, p<0.001). In the regions of preserved perfusion (${\geq}60%$), $E_{max}$ was $2.65{\pm}1.67$, while it was $1.30{\pm}1.24$ in the segments of decreased perfusion. With regard to thickening, $E_{max}$ was $3.01{\pm}1.92$ mmHg/ml for normal regions (thickening ${geq}40%$), $2.40{\pm}1.19$ mmHg/ml for mildly dysfunctional regions (<40% and ${\geq}20%$), and $1.13{\pm}0.89$ mmHg/ml for severely dysfunctional regions (<20%). $E_{max}$ was improved after CABG in both the viable (from $1.27{\pm}1.07\;to\;1.79{\pm}1.48$ mmHg/ml) and non-viable segments (from $0.97 {\pm}0.59\;to\;1.22{\pm}0.71$ mmHg/ml), but there was no correlation between $E_{max}$ and thickening improvements (r=0.007). Conclusions: Preoperative regional $E_{max}$ was relatively concordant with regional perfusion and systolic thickening on gated myocardial SPECT. In dysfunctional but viable segments, $E_{max}$ was improved after CABG, but showed no correlation with thickening improvement. As a load-independent contractility index of dysfunctional myocardial segments, we suggest that the regional $E_{max}$ could be an independent parameter in the assessment of myocardial function.

Mineral extraction from by-products of brown rice using electrodialysis and production of mineral salt containing lower sodium (전기투석을 이용한 현미부산물로부터의 미네랄성분 추출 및 나트륨감량형 미네랄 소금 제조)

  • No, Nam-Doo;Park, Eun-Jung;Kim, Mi-Lim
    • Food Science and Preservation
    • /
    • v.22 no.6
    • /
    • pp.859-866
    • /
    • 2015
  • The purpose of this study was to develop a supplemental healthy food that can help prevent high blood pressure-related diseases caused due to the excessive consumption of sodium in salt. This was achieved by using ion-displacement techniques to produce mineral salt with lower sodium content by using fermented brown rice by-products rich in minerals. Mineral salt containing 2019.2 mg/100 g of potassium, 678.5 mg/100 g of magnesium, 48.7 mg/100 g of calcium, and 19.5 mg/100 g of sodium was obtained by fermenting brown rice by-products to create a culture medium for the mineral salt. Mineral salt containing 1769.7 mg/100 g of potassium, 573.6 mg/100 g of magnesium, 35.3 mg/100 g of calcium, and 19.5 mg/100 g of sodium was obtained by filtering and refining the by-product extract of fermented brown rice. The results showed that when the stream velocity of the instrument used for electrolysis was 200 mL/min and the current and the concentration of the reactive liquid in the purified water chamber were higher, the effect of electrolysis was greater. Ion hot water extraction of the fermented brown rice by-products improved by up to 95% and was collected as purified water within 90 min of the reaction time. Chloride ions with pH 7.4 were produced by mixing sodium hydroxide in a purified saline water chamber with electro-analyzed water. The salt produced in this study contained low sodium, 5.7~30%, as compared to 40% sodium content of the normal salt.