• Title/Summary/Keyword: P waves

Search Result 470, Processing Time 0.105 seconds

Surface and Internal Waves Scattering by Partial Barriers in a Two-Layer Fluid (이층유체에서 부분 장벽에 의한 표면파와 내부파의 분산)

  • Kumar, P.Suresh;Oh, Young-Min;Cho, Won-Chul
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.20 no.1
    • /
    • pp.25-33
    • /
    • 2008
  • Water waves are generated mainly by winds in open seas and large lakes. They carry a significant amount of energy from winds into near-shore region. Thereby they significantly contribute to the regional hydrodynamics and transport process, producing strong physical, geological and environmental impact on coastal environment and on human activities in the coastal area. Furthermore an accurate prediction of the hydrodynamic effects due to wave interaction with offshore structures is a necessary requirement in the design, protection and operation of such structures. In the present paper surface and internal waves scattering by thin surface-piercing and bottom-standing vertical barriers in a two-layer fluid is analyzed in two-dimensions within the context of linearized theory of water waves. The reflection coefficients for surface and internal waves are computed and analyzed in various cases. It is found that wave reflection is strongly dependent on the interface location and the fluid density ratio apart from the barrier geometry.

Effect of Millimeter Waves on Quality Characteristics of Cheonggukjang (밀리미터파 처리가 청국장의 이화학적 특성에 미치는 영향)

  • Seo, Dong-Ho;Kim, Mi-Seon;Kum, Jun-Seok
    • Food Engineering Progress
    • /
    • v.21 no.2
    • /
    • pp.126-131
    • /
    • 2017
  • Millimeter waves are electromagnetic waves with frequencies of 30-300 GHz (wavelength 1-10 mm), and millimeter wave stimulation affects microorganism growth. The present study stimulated Bacillus subtilis with 60 and 70 GHz millimeter waves during cheonggukjang fermentation and characterized the effects on cheonggukjang quality. Cheonggukjang treated with millimeter wave irradiation showed no significant difference in total bacterial count but generated only 5.52-5.92% viscous substance. Irradiation with 60 GHz millimeter waves yielded bright and intense color values relative to 70 GHz millimeter waves. Examination of the amylase activity and reducing sugar content of finished cheonggukjang revealed that irradiation at 70 GHz inhibited amylase activity in cheonggukjang. Furthermore, irradiation at 70 GHz increased protease activity, whereas irradiation at 60 GHz inhibited the activity. Moreover, the amino acid content changed with millimeter wave irradiation.

Postprandial Epigastric Fullness and Pyloric Valve Disturbance in Patients with Functional Dyspepsia;Analysis of Bowel Sounds and Electrogastrography (기능성(機能性) 소화불량증(消化不良症) 환자(患者)의 식후(食後) 심하비만과 pyloric valve의 기능장애(機能障碍);장음과 위전도를 중심으로)

  • Yoon, Sang-Hyub
    • The Journal of Internal Korean Medicine
    • /
    • v.28 no.4
    • /
    • pp.769-778
    • /
    • 2007
  • Background & Object : Postprandial epigastric fullness is one of common symptoms in functional dyspepsia, but its pathophysiological mechanism has still been unknown. In this study, its association between postprandial epigastric fullness and pyloric valve disturbance was studied through analysis of bowel sounds and electrogastrography. Methods : Bowel sounds and electrogastrography were recorded together for fasting 15 min and postprandial 40 min. Parameters of bowel soundincluding motility index, sound to sound interval, standard deviation of sound to sound interval, sounds per minute, % of bowel sound, sound length, intensity, dominant frequency of sounds, and postprandial / fasting ratio of dominant frequency of sounds were analyzed with a specialized program. By electrogastrography, regularity of slow waves and power ratio were obtained. Results : Significances of bowel sounds appeared in motility index (p=0.046), dominant frequency of fasting (p=0.048), postprandial (p=0.003), and the ratio of postprandial/fasting (p=0.000); those of EGG parameters were shown in postprandial regularity of slow waves (p=0.006) and power ratio (p=0.011). Conclusion : Pyloric valve disturbance was a cause of postprandial epigastric fullness in patients with functional dyspepsia. Analysis of bowel sound might be useful in diagnosing its existence.

  • PDF

Correlations between the group velocity of time-reversed Lamb waves and cortical bone properties in tibial cortical bone in vivo (생체 내 경골의 피질골에서 시간역전 램파의 군속도와 피질골 특성 사이의 상관관계)

  • Kang Il Lee
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.6
    • /
    • pp.559-564
    • /
    • 2023
  • It is known that change in the bone strength of cortical bone constituting the outer shell of long bones such as the tibia or radius due to aging and osteoporosis is a risk factor for fracture. In this study, the group velocity of time-reversed Lamb waves generated in tibial cortical bone in vivo was measured using a time reversal method, and the correlations of the group velocity with the cortical bone thickness (cTh) and cortical bone mineral density (cBMD) closely related to the bone strength were investigated. It was found that the group velocity of time-reversed Lamb waves measured in the right tibia of 7 subjects showed a very high correlation, r = 0.90 (p < 0.0001), with the cTh and a relatively low correlation, r = 0.69 (p < 0.0001), with the cBMD. A limitation of this in vivo study is that the group velocity of time-reversed Lamb waves was measured for a normal group consisting of only 7 healthy adults. In the future, if the clinical usefulness of the time-reversed Lamb wave is demonstrated by follow-up studies on normal and osteoporotic groups consisting of a large number of healthy adults and osteoporotic patients, respectively, it is expected to improve the reliability of quantitative ultrasound technology for osteoporosis diagnosis. In addition, it is necessary to expand the skeletal site for measuring the group velocity of time-reversed Lamb waves not only to the tibia but also to the femur or radius.

Electromagnetic Wave in all Base Stations (다기지국 환경에서 전자파 노출량)

  • Cho, Euy-Hyun;Park, Jeong-Kyu
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.9
    • /
    • pp.26-44
    • /
    • 2011
  • The Study was carreid out to see whether the intensity of electromagnetic waves in each floor of a building where the sharing base station has been established is harmful to a human body, and to expect the intensity of the waves in the building. The investigate was performed on both of sharing base station either with many scatterers or without any of them. To satisfy the international standard and the domestic TTA standard, rms for each of the electromagnetic wave of every floor in the building with the station was measured from 3 location of 3 heights(1.1m,1.5m, and 1.7m). Max of the measured rsm from the each of the frequencies in the nine location was confirmed to be 48.12%(the rooftop measured value) at most, compared to the human body protection standard. The value was confirmed to satisfy the human body protection standard for each frequency. And the total value of the calculated exposure indexes for each frequency was determined to be more than 7 times lower at most, which was 0.1445, compared to the 1 standard. Since P value in both of 868MHz and 2.14GHz electromagnetic waves intensity for each base station and floor was less than 0.05, it was revealed to be meaningful, and since R-Sq(adj) value showed a value more than 50%, the regression equation was determined to fully absorb the data information. However, although the P value of both of 868MHz and 2.14GHz electromagnetic waves intensities under the integrating terms of the base station data and the floor data was showed to be less than 0,05, since R-Sq(adj) value of 868MHz electromagnetic waves intensity presented a value smaller than 50%(34.15%), it was determined that the 868MHz electromagnetic waves intensity is very much influenced by an environment with a base station. Because the electromagnetic waves intensity of 2.14GHz show R-Sq(adj) value bigger then 50%(51.8%), The regression equation model of 2.14GHz electromagnetic waves intensity was confirmed to be proper. It also turned out not to be effected by the surrounding environment near a building with the base station and the intensity of electromagnetic waves for each floor of such building was expectable by the regression equation.

An Axially Marching Scheme for Internal Waves

  • In-Joon,Suh
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.25 no.2
    • /
    • pp.1-10
    • /
    • 1988
  • An axially marching numerical method is developed for the simulation of the internal waves produced by translation of a submersed vehicle in a density-stratified ocean. The method provides for the direct solution of the primitive variables [$\upsilon,\;p,\;\rho$] for the nonlinear and steady state three-dimensional Euler's equation with a non-constant density term in the vehicle-fixed cartesian co-ordinate system. By utilizing a known potential flow around the vehicle for an estimate of the axial velocity gradient, the present parabolic algorithm local upstreamwise disturbances and axial velocity variation.

  • PDF

Discimination of Decoupled Explosions from Microearthquakes

  • Kim, So-Gu
    • Proceedings of the Korean Society for Rock Mechanics Conference
    • /
    • 1995.03a
    • /
    • pp.108-108
    • /
    • 1995
  • There are always some difficulties to discriminate artificial exlposions from micro-earthquakes, furthermore more difficulties to identify and determine decoupled explosions and/or multiple explosions from micro-earthquakes. In this study we use the synthetic seismogram of the in homogeneous models between the source and the observation station in order to find the source effect of the geological environment. We have found some source characteristics of the air-filled and/or water-filled cavity that we can hardly see P-n and S- waves arrivals and that the high frequency coda waves are well observed compared to the coupled explosions or earthquakes.

  • PDF

Analysis of Concentration-Related EEG Component Due to Smartphone (스마트폰에 의한 집중력 관련 뇌파성분의 분석)

  • Jang, Yun-Seok
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.11 no.7
    • /
    • pp.717-722
    • /
    • 2016
  • The purpose of this study is to observe the changes of EEG signals in the process for solving the problems in concentration. In the experiments, subjects were given two tasks. The first task is to memorize the words after they used their own smart phone for ordinary commercial games and the second task is to memorize the words after they read a page of a p-book. In this paper, we present SMR waves and mid-beta waves to analyze from the EEG signals of the subjects because the waves are the EEG components related to concentration of human.

Thermal Comfort Evaluation of Protective Clothing for Shielding Electromagnetic Waves (전자파 차단 보호복의 온열쾌적성 평가)

  • Choi, Jeong-Wha;Kim, Myung-Ju;Park, Joon-Hee;Kim, Do-Hee
    • The Korean Journal of Community Living Science
    • /
    • v.21 no.4
    • /
    • pp.595-603
    • /
    • 2010
  • The present study was performed on humans to investigate the physiological strain of wearing protective clothing for shielding electromagnetic waves and to compare control clothing that are currently on the market and new clothing that are developed for improving thermal comfort and material weight. Experiments were conducted in a climatic chamber of $28.8{\pm}0.6^{\circ}C$, $37{\pm}5%$RH under three differed experimental clothing conditions: None, Control, New. The results were as follows. Mean skin temperature and rectal temperature in New were significantly lower than that in None and Control (p<.05). The temperature and humidity inside clothing were lower in None (p<.05). Total weight loss was lower in New. Thermal sensation and thermal comfort were less hot and more comfortable in New than those in Control. It was concluded that wearing the protective clothing for shielding electromagnetic waves affects physiological responses such as distribution of body temperature, sweat rate, etc.

Separation of Linear and Elliptic Particle Motions Using Multi-Component Complex Trace Analysis (다성분 복소트레이스 분석법에 기초한 선형 및 타원형 입자운동 분리)

  • Kim, Ki-Young;Lee, So-Young
    • Geophysics and Geophysical Exploration
    • /
    • v.12 no.3
    • /
    • pp.246-254
    • /
    • 2009
  • We developed a novel polarization filter to separate linearly polarized waves from elliptically polarized waves in an infinite homogeneous medium and at the free surface using methods of multicomponent complex trace analysis. Sensitivity to filter parameters were examined using synthetic data simulating particle motions in a homogeneous medium. For known amplitude ratios of horizontal-to-vertical components of P and Rayleigh waves $C_L$ and $C_R$, respectively, the polarization filter precisely removes Rayleigh waves. Errors in the vertical and horizontal components of the filtered results increase with the ratio $C_R$/$C_L$ and the product $C_R$.$C_L$, respectively. The vertical component errors also increase rapidly as the ratios of applied-to-modeled values of $C_L$ and $C_R$ ($C_L'$/$C_L$ and $C_R'$/$C_R$) decrease, and are sensitive to $C_R'$/$C_R$ and $C_L'$/$C_L$ for small and large incidence angles, respectively. Errors of the filter are exactly the same for shear waves when the incidence angle is the supplementary of P-wave incidence angle.