• Title/Summary/Keyword: P/S mode

Search Result 626, Processing Time 0.031 seconds

Evaluation of shade guide using digital shade analysis system (색조 선택 시스템을 이용한 shade guide의 색조 분석)

  • Lee, Seung-Taek;Lee, Jong-Hyuk;Shin, Soo-Yeon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.1
    • /
    • pp.1-11
    • /
    • 2009
  • Statement of problem: There are two methods of color choice for the esthetic restoration. One is visual shade matching which draws a comparison between shade guide and teeth in dentist's own eye and the other is using a digital shade analysis system recently introduced. Although the visual shade matching has a lot of problems, decision of color by this visual shade matching and the ways of expression for the decided color are still applicable to clinical dentistry. Purpose: This study is designed to investigate shade guides used in the dental clinics and laboratories have the same value using ShadeEye-$NCC^{(R)}$ dental chroma meter (Shofu Inc., Kyoto, Japan) using shade guide are evaluated. Material and methods: At the first experiment, eight Vita Lumin Vacuum shade guides (Vident Inc., California, USA) were collected from the dental clinics. A1 and B1 shade tabs are chosen and the colors are analyzed five times each in both tooth and porcelain modes by digital shade analysis system, ShadeEye-$NCC^{(R)}$. In the second experiment, twelve Vita shade guides using practically in the dental clinics and laboratories were collected and also A1 and B1 shade tabs are chosen and the colors of A1 and B1 are analyzed one time each in both tooth and porcelain modes by ShadeEye-$NCC^{(R)}$. Results and conclusion: There were significant differences among eight shade guides in terms of shade (chroma), value and hue in both of A1 and B1 (P<.05). Shade guides using in present both dental clinics and laboratories did not show significant differences, except A1 in the porcelain mode, it showed significant differences (P<.05) in the shade even though the shade tab has the same name.

Herbicidal Activities of Phenylvinylsulfone Derivatives (Phenylvinylsulfone 유도체의 제초활성)

  • Yu, Seong-Jae;Jeon, Dong-Ju;Kim, Dae-Whang;Sung, Nack-Do
    • Applied Biological Chemistry
    • /
    • v.38 no.1
    • /
    • pp.90-94
    • /
    • 1995
  • Post emergence herbicidal activities$(pI_{50})$ of X-substituted phenylvinylsulfone derivatives(S) in-vivo against rice(Oryza sativa L.), Barnyard grass(Echinochloa crus-galli) and Pickerelweed(Monochoria vaginalis Presl) were measured by the pot test under paddy conditions. The (S) showed herbicidal symptom rapidly with lower activity(average $pI_{50}=2.0$) as proherbicide, which was excellent tolerance to rice. The structure activity relationships(SAR) were analyzed using such a physicochemical parameters as hydrophobic$({\pi})$ and molecular orbital(MO) quantity by the multiple regression technique, and discussed with quantum pharmacology. The herbicidal activities were related to the hydrophobic$({\pi})$ effect of X-substituent and orbital(HOMO & LUMO) energy. In case of Pickerelweed, the effect was rationalized by parabolic function of ${\pi}$ constant, where the optimal value of ${\pi}$ was 1.10. An increase in hydrophobicity and negative orbital energy by the electron attracting X-substituent may contribute to the herbicidal activity. Based on results proposed from SAR analysis, the mode of herbicidal action could be assumed.

  • PDF

Evaluation of Respiratory Parameters in Patients with Acute Lung Injury Receiving Adaptive Support Ventilation (급성 폐손상 환자에서 Adaptive Support Ventilation 적용 시 호흡지표의 양상)

  • Lee, Keu-Sung;Chung, Wou-Young;Jung, Yun-Jung;Park, Joo-Hun;Sheen, Seung-Soo;Hwang, Sung-Chul;Park, Kwang-Joo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.70 no.1
    • /
    • pp.36-42
    • /
    • 2011
  • Background: Adaptive support ventilation (ASV), an automated closed-loop ventilation mode, adapts to the mechanical characteristics of the respiratory system by continuous measurement and adjustment of the respiratory parameters. The adequacy of ASV was evaluated in the patients with acute lung injury (ALI). Methods: A total of 36 patients (19 normal lungs and 17 ALIs) were enrolled. The patients' breathing patterns and respiratory mechanics parameters were recorded under the passive ventilation using the ASV mode. Results: The ALI patients showed lower tidal volumes and higher respiratory rates (RR) compared to patients with normal lungs ($7.1{\pm}0.9$ mL/kg vs. $8.6{\pm}1.3$ mL/kg IBW; $19.7{\pm}4.8$ b/min vs. $14.6{\pm}4.6$ b/min; p<0.05, respectively). The expiratory time constant (RCe) was lower in ALI patients than in those with normal lungs, and the expiratory time/RCe was maintained above 3 in both groups. In all patients, RR was correlated with RCe and peak inspiratory flow ($r_s$=-0.40; $r_s$=0.43; p<0.05, respectively). In ALI patients, significant correlations were found between RR and RCe ($r_s$=-0.76, p<0.01), peak inspiratory flow and RR ($r_s$=-0.53, p<0.05), and RCe and peak inspiratory flow ($r_s$=-0.53, p<0.05). Conclusion: ASV was found to operate adequately according to the respiratory mechanical characteristics in the ALI patients. Discrepancies with the ARDS Network recommendations, such as a somewhat higher tidal volume, have yet to be addressed in further studies.

Studies on the Optimum Surface Treatment Conditions and the Interfacial Bond Strength of Glass fiber/Nylon 6 Composites (유리섬유/Nylon 6 복합재료의 표면처리 최적조건과 개별결합력에 관한 연구)

  • 나성기;박종신
    • Proceedings of the Korean Fiber Society Conference
    • /
    • 1997.04a
    • /
    • pp.26-31
    • /
    • 1997
  • 유리섬유/nylon 6 복합재료의 계면결합강도를 증가시키기 위하여 r-APS(r-Aminopropyltriethoxysilane)로 유리섬유의 표면을 처리 하였다. 이때 표면처리의 최적 조건을 찾기위해서 처리후 기기분석과 계면결합강도 측정 등을 하였다. 농도, pH, 처리시간, 온도를 변화시키면서 표면처리를 한 후 흡착량을 살펴본 결과 처리 농도에 의해서는 흡착량이 단조증가하였으며 처리시간에 따라서는 5분정도에서, 처리온도에 의해서는 30C 부근에서 최대 흡착량을 보였다. 또한 pH에 따른 흡착량은 silane의 고유 pH인 10.5부근에서 최대치를 나타냈다. FR-IR 분석에 의하면 NH2의 NH3 bending mode가 1607cm-1, 1575cm-1에서 나타났으며 SiOH의 SiO band는 960cm-1에서 나타났다. XPS를 통해서는 N ls와 Si 2p의 존재를 확인할 수 있었다. 표면처리된 유리섬유와 matrix인 nylon 6를 이용해 단섬유내장시편을 만들어 fragmentation test를 한 결과 계면결합강도는 약 5분의 처리시간과 1%(wt%)의 농도에서 최대값을 보였다.

  • PDF

Disposable Solid-State pH Sensor Using Nanoporous Platinum and Copolyelectrolytic Junction

  • Noh, Jong-Min;Park, Se-Jin;Kim, Hee-Chan;Chung, Taek-Dong
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.11
    • /
    • pp.3128-3132
    • /
    • 2010
  • A disposable solid-state pH sensor was realized by utilizing two nanoporous Pt (npPt) electrodes and a copolyelectrolytic junction. One nanoporous Pt electrode was to measure the pH as an indicating electrode (pH-IE) and the other assembled with copolyelectrolytic junction was to maintain constant open circuit potential ($E_{oc}$) as a solid-state reference electrode (SSRE). The copolyelectrolytic junction was composed of cationic and anionic polymers immobilized by photo-polymerization of N,N'-methylenebisacrylamide, making buffered electrolytic environment on the SSRE. It was expected to make. The nanoporous Pt surrounded by a constant pH excellently worked as a solid state reference electrode so as to stabilize the system within 30 s and retain the electrochemical environment regardless of unknown sample solutions. Combination between the SSRE and the pH-IE commonly based on nanoporous Pt yielded a complete solid-state pH sensor that requires no internal filling solution. The solid state pH sensing chip is simple and easy to fabricate so that it could be practically used for disposable purposes. Moreover, the solid-state pH sensor successfully functions in calibration-free mode in a variety of buffers and surfactant samples.

Mean Velocity of Globular Cluster Systems in M86 Virgo Giant Elliptical Galaxy and Massive Early-Type Galaxies

  • Park, Hong Soo;Lee, Myung Gyoon;Arimoto, Nobuo
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.40 no.2
    • /
    • pp.33.3-34
    • /
    • 2015
  • We present the spectroscopic study of the globular clusters (GCs) in the massive elliptical galaxy M86 in the Virgo galaxy cluster. Using the spectra obtained from the Multi-Object Spectroscopy (MOS) mode of Faint Object Camera and Spectrograph (FOCAS) on the Subaru Telescope, we measure the radial velocities for 56 GCs in M86. The mean velocity of the GCs is derived to be $<v_p>=-335{\pm}41km/s$, which is different from the velocity of the M86 nucleus ($<v_{gal}>=-224{\pm}5km/s$) within ${\sim}2.5{\sigma}$. The mean velocity ($<v_p>=-342{\pm}60km/s$) of 33 blue GCs in M86 is similar to that ($<v_p>=-314{\pm}71km/s$) of 23 red GCs. We also derive the mean velocities of the GC systems in other 16 nearby early-type galaxies (ETGs) from the radial velocity data in the literature. The mean value of the differences between the mean velocity of the GC systems in each galaxy and the nucleus velocity of their host galaxies, is almost zero except the M86 GC system. But the scatter of the differences in the blue GC system is larger than that in the red GC system. We will discuss these results in the context of GC formation in ETGs.

  • PDF

Analysis of the Relationships according to the Frame (f/s) Change of Cine Imaging in Coronary Angiographic System: With Focus on FOV Enlargement and Live Zoom (심장 혈관 조영장치에서의 프레임 레이트(f/s) 변화에 따른 상관 관계 분석 : FOV 확대와 Live Zoom을 중점으로)

  • Kim, Won Hyo;Song, Jong-Nam;Han, Jae-Bok
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.7
    • /
    • pp.845-852
    • /
    • 2018
  • This study aimed to investigate the difference of X-ray exposure by comparing and analyzing absorbed dose according to changes in the number of frames in coronary angiography, also depending whether the zoom mode is FOV enlargement or Zoom Live. Moreover, for appropriate frame selection measures for examination, including the effect of frame change on the image quality, were sought by measuring the noise strength expressed by the standard deviation (SD), the signal to noise ratio (SNR) and contrast to noise ratio (CNR). The study was conducted with an anthropomorphic phantom on an angio-system. The linear relationship between the frame rate and the radiation dose was evident. On the contrary, the indices of image quality (SD, SNR, and CNR) were almost constant irrespective of the number of frames. The difference depending on the zoom mode was not statistically significant for DAP, air kerma, and SD (p > 0.05). However, SNR and CNR were statistically different between FOV enlargement and Zoom Live. In conclusion, since the image quality was not degraded significantly with the decreasing frame rate from 30, 15, to 7.5 f/s and the radiation dose evidently decreases in almost exactly linear proportion to the decreasing frame rate, the number of frames per second needs to be maintained as low as reasonably achievable. As for the dependence on the zooming mode, the Live Zoom mode showed statistically significant improvement in the image quality indices of SNR and CNR and it justifies active use of the Live Zoom mode which enables real-time image enlargment without additional radiation dose.

Analysis of Propagation Environment for Selecting R-Mode Reference and Integrity Station (R-Mode 보정국과 감시국 선정을 위한 전파환경 분석에 관한 연구)

  • Jeon, Joong-Sung;Jeong, Hae-Sang;Gug, Seung-Gi
    • Journal of Navigation and Port Research
    • /
    • v.45 no.1
    • /
    • pp.26-32
    • /
    • 2021
  • In ocean field, the spread of the Fourth Industrial Revolution based on information and communication technology requires high precision and stable PNT&D (Position, Navigation, Timing and Data). As the IMO (International Maritime Organization) and IALA (The International Association of Marine Aids to Navigation and Lighthouse Authorities) are requiring backup systems due to mitigate vulnerabilities and the increase of dependency on GNSS (Global Navigation Satellite System), Korea is conducting a research & development of R-Mode. An DGPS (Differentiate Global Positioning System) reference station that uses MF, an existing maritime infrastructure, and AIS (Automatic Identification System) base stations that use 34 integrity station and VHF will be utilized in this study to avoid redundant investment. Because there are radio shadow areas that display low signal levels in the west sea, the establishment of new R-Mode reference and integrity station will be intended to resolve problems regrading the radio shadow area. Because the frequency has a characteristic in that radio wave transmits well along the ground (water surface) in low frequency band, simulation and measurement were conducted therefore this paper to propose candidate sites for R-Mode reference and integrity station resulted through p wave's propagation characteristics analysis. Using this paper, R-Mode reference and integrity station can be established at appropriate locations to resolve radio shadow areas in other regions.

A COMPARATIVE STUDY OF SHEAR BOND STRENGTH OF FLOWABLE RESIN ASSOCIATED WITH DENTIN ADHESIVE SYSTEMS WITH THERMOCYCLING EFFECT (상아질접착제와 열순환에 따른 유동성 레진의 전단결합강도 비교 연구)

  • Nam Ki-Young
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.4
    • /
    • pp.383-393
    • /
    • 2006
  • Statement of problem : Limited research on flowable resin has been undertaken on its application directly on dentin associated with the adhesive systems. Purpose : This study was to evaluate the shear bond strengh and fracture aspect of flowable resin on human dentin with various types of dentin bonding adhesives with thermo cycling effect. Materials and methods: Filtek-Flow(3M ESPE, USA) was used as flowable resin and Eighty human molars were randomly divided into 4 groups : three dentin bonding adhesives (Scotchbond-Multipurpose : 3-step contentional system, One-Step : One-bottle system. Prompt L-Pop : All-in-one, self-etching primer) and 32% etching treatment without bonding adhesive as a control group. For evaluating their durability of bonding, each group was subdivided : storaging in the water at 37$^{\circ}C$(24 hours) and thermocycling (0$^{\circ}C$-55$^{\circ}C$, 30 seconds intervals, 1000 cycle). Shear bond strength tests were performed and resin-dentin interface and fracture mode were observed. Results were analysed by one-way ANOVA and Scheffe's multiple range test. Results and Conclusion : 1. At 0 cycle, the mean shear bond strength of One-Step exhibited the highest value of all groups(p<0.05), and there were no significant differences between Prompt L-Pop and Scotchbond-Multipurpose, Scotchbond-Multipurpose and control(p>0.05). After 1000 thermocycling, One-Step exhibited higher value than other groups(p<0.05), and there were no significant differences among other groups (p>0.05). 2. The shear bond strength of each group was significantly decreased after thermocycling except Scotchbond-Multipurpose (p>0.05). 3. The most common failure mode was adhesive type and mixed type, next in order.

An explanatory model of quality of life in high-risk pregnant women in Korea: a structural equation model

  • Mihyeon Park;Sukhee Ahn
    • Women's Health Nursing
    • /
    • v.29 no.4
    • /
    • pp.302-316
    • /
    • 2023
  • Purpose: This study aimed to develop and validate a structural model for the quality of life (QoL) among high-risk pregnant women, based on Roy's adaptation model. Methods: This cross-sectional study collected data from 333 first-time mothers diagnosed with a high-risk pregnancy in two obstetrics and gynecology clinics in Cheonan, Korea, or participating in an online community, between October 20, 2021 and February 20, 2022. Structured questionnaires measured QoL, contextual stimuli (uncertainty), coping (adaptive or maladaptive), and adaptation mode (fatigue, state anxiety, antenatal depression, maternal identity, and marital adjustment). Results: The mean age of the respondents was 35.29±3.72 years, ranging from 26 to 45 years. The most common high-risk pregnancy diagnosis was gestational diabetes (26.1%). followed by preterm labor (21.6%). QoL was higher than average (18.63±3.80). Above-moderate mean scores were obtained for all domains (psychological/baby, 19.03; socioeconomic, 19.00; relational/spouse-partner, 20.99; relational/family-friends, 19.18; and health and functioning, 16.18). The final model explained 51% of variance in QoL in high-risk pregnant women, with acceptable overall model fit. Adaptation mode (β=-.81, p=.034) and maladaptive coping (β=.46 p=.043) directly affected QoL, and uncertainty (β=-. 21, p=.004), adaptive coping (β=.36 p=.026), and maladaptive coping (β=-.56 p=.023) indirectly affected QoL. Conclusion: It is essential to develop nursing interventions aimed at enhancing appropriate coping strategies to improve QoL in high-risk pregnant women. By reinforcing adaptive coping strategies and mitigating maladaptive coping, these interventions can contribute to better maternal and fetal outcomes and improve the overall well-being of high-risk pregnant women.