• Title/Summary/Keyword: Ozone effect

Search Result 508, Processing Time 0.032 seconds

Effect of Treatment with Ozonated Water on Shelf Life of Refrigerated Meat (오존수 처리가 냉장 쇠고기의 화학적 품질에 미치는 영향)

  • Kim, Min-Ju;Shin, Han-Seung
    • Food Science of Animal Resources
    • /
    • v.31 no.4
    • /
    • pp.617-623
    • /
    • 2011
  • Ozone is a strong oxidant and potent disinfecting agent. In this study, volatile basic nitrogen, thiobarbituric acid reactive substances, acid value and pH all of which are quality indicators in meat products, were evaluated. The meat was treated with the ozonated water (0.2 ppm) for 0, 5, 10, 30, and 60 min and then stored at $5^{\circ}C$ for 24 d. The volatile basic nitrogen content of meat was 22.40 mg% after 9 d of storage and 23.24 mg% at 15 d of storage with ozonated water (0.2 ppm) treatment. During 24 d of storage, the pH, thiobarbituric acid reactive substances, and acid value were decreased when subjected to ozonated water treatment. These results suggested that the ozonated water treatment effectively improved the chemical properties and food safety.

Effect of surfactant types in aqueous cleaning agents on their physical properties, cleaning ability and oil-water separation (수계세정제의 계면활성제 종류에 따른 물성, 세정성 및 유수분리 영향 연구)

  • Park, S. W.;Cha, A. J.;Kim, H. T.;Kim, H. S.;Bae, J. H.
    • Clean Technology
    • /
    • v.9 no.1
    • /
    • pp.9-21
    • /
    • 2003
  • CFC-113 and 1,1,1-TCE which are ozone destruction substances are not used any more in the advanced countries because of Montreal protocol. MC and TCE are now used restrictively at small part of industrial fields in most of countries since they are known to be hazardous or carcinogenic materials. Thus, it is indispensible that the alternative cleaning agents which are environmental-friendly and safe, and show good cleaning ability should be developed or utilized for replacement of the halogenated cleaning agents. Aqueous cleaning agents are evaluated to be promising alternative ones among various alternatives in environmental and economical view point. This study has been carried out as a part of development program of aqueous cleaning agent. First of all, several types of surfactants which are the most important component in aqueous cleaning agents were chosen, and the physical properties, foaming ability, cleaning ability and oil-water separation efficiency of their aqueous solutions were measured and compared for selection of proper type of surfactant in aqueous cleaning agents.

  • PDF

High School Students' Preconception about the Causes and Consequences of Climate Change (기후변화의 원인과 결과에 대한 고등학생들의 선 개념 연구)

  • Han, Shin;Jeong, Jinwoo
    • Journal of Science Education
    • /
    • v.38 no.2
    • /
    • pp.430-442
    • /
    • 2014
  • The purpose of this study is to investigate the Preconception about the causes and consequences of climate change. Participants were 196 High school students who live in Seoul and Gyeong-gi Province. And data was collected through questionnaire to confirm preconception about the causes and consequences of Climate Change. After confirming with students preconceptions, 10 people randomly selected and Semi-structured interview were conducted. The findings is students did not know exactly about Ozone depletion, global warming, the greenhouse effect factors and causal relationships. And we can confirm that the student's preconception is affecting.

  • PDF

Ozone-Activated Carbon Treatment in Middle Keum River containing Ammonia-Nitrogen (암모니아성질소를 함유한 금강중류 하천수의 오존-활성탄처리)

  • Kim, Chung-Hwan;Jung, Sang-Gi;Kim, Hag-Seong
    • Journal of Korean Society on Water Environment
    • /
    • v.18 no.4
    • /
    • pp.355-363
    • /
    • 2002
  • A demonstration plant was carried out to investigate the removal efficiency of $NH_3-N$ and $KMnO_4$ consumption depending on the existence of pre-chlorination for the ozonation and activated carbon process in the S water treatment plant which is located at the middle of Keum River. The averge removal efficiency of $KMnO_4$ consumption for $O_3/GAC$ processes with pre-chlorination and $O_3/BAC$ processes without pre-chlorination were 48.6% and 50% respectively. It is similar to removal effect of $KMnO_4$ consumption for GAC and BAC process depending on the existence of pre-chlorination. Otherwise, the removal of THMFP for GAC and BAC process was 58% and 68% respectively. $NH_3-N$ was not almost removed by sand filter and ozonation, but the average removal efficiency in the BAC process was about 31%. Especially, $NH_3-N$ was not almost removed by $O_3/BAC$ processes at the low temperature (below $$10^{\circ}C$$) in the winter season, $O_3/BAC$ processes have the advantage of removal of organic substance when it is compared to pre -chlorination followed by $O_3/GAC$ processes. Pre-chlorination followed by $O_3/GAC$ processes were required to remove $NH_3-N$ in the winter season because the removal of $NH_3-N$ was almost ineffective by $O_3/BAC$ process.

A Study of LCD Panel Cleaning Effect of Plasma Generation Power Source (플라즈마 발생용 전원장치의 LCD 패널 세정효과에 관한 연구)

  • Kim, Gyu-Sik
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.45 no.5
    • /
    • pp.44-51
    • /
    • 2008
  • UV lamp systems have been used for cleaning of display panels of TFT LCD or Plasma Display Panel (PDP). However, the needs for high efficient cleaning and low cost made high voltage plasma cleaning techniques to be developed and to be improved. Dielectric-Barrier Discharges (DBDs), also referred to as barrier discharges or silent discharges have been exclusively related to ozone generation for a long time. In this paper, a 6kW high voltage plasma power supply system was developed for LCD cleaning. The 3-phase input voltage is rectified and then inverter system is used to make a high frequency pulse train, which is rectified after passing through a high-power transformer. Finally, hi-directional high voltage pulse switching circuits are used to generate the high voltage plasma. Some experimental results showed the usefulness of atmospheric plasma for LCD panel cleaning.

Numerical study on fluid characteristics due to disc shape in a novel mechanical ballast water treatment system (신개념 기계식 선박평형수 처리장치의 디스크 형상에 따른 유동특성에 관한 수치해석 연구)

  • Sohn, Sang-Ho;Kim, Young-Chul;Choi, Kung-Kwan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.1
    • /
    • pp.19-27
    • /
    • 2015
  • As the recent regulation of Internaional Maritime Organization (IMO) is enforced, the advanced technology of Ballast water treatment system (BWTS) is needed to meet its requirements. Until now, there are two kinds of the BWTS technologies such as physical methods (Membrane and UV) and chemical methods (Chlorin and Ozone). However, these conventional methods have some limitations of auxiliary power, low productivity, residual treatment and etc. In order to overcome these problems, this paper introduces the new kind of BWTS based on mechanical principle and investigates the effect of rotating disc shapes on flow characteristics between rotating and stationary discs by computational fluid dynamics (CFD). Planar and Step types can make the local cavitation generated along radius, and Circular type can increase the intensity of shear stress.

Relation with Activity of Road Mobile Source and Roadside Nitrogen Oxide Concentration (도로이동오염원의 활동도와 도로변 질소산화물 농도의 관계)

  • Kim, Jin Sik;Choi, Yun Ju;Lee, Kyoung Bin;Kim, Shin Do
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.32 no.1
    • /
    • pp.9-20
    • /
    • 2016
  • Ozone has been a problem in big cities. That is secondary air pollutant produced by nitrogen oxide and VOCs in the atmosphere. In order to solve this, the first to be the analysis of the $NO_x$ and VOCs. The main source of nitrogen oxide is the road mobile. Industrial sources in Seoul are particularly low, and mobile traffics on roads are large, so 45% of total $NO_x$ are estimated that road mobile emissions in Seoul. Thus, it is necessary to clarify the relation with the activity of road mobile source and $NO_x$ concentration. In this study, we analyzed the 4 locations with roadside automatic monitoring systems in their center. The V.K.T. calculating areas are set in circles with 50 meter spacing, 50 meter to 500 meter from their center. We assumed the total V.K.T. in the set radius affect the $NO_x$ concentration in the center. We used the hourly $NO_x$ concentrations data for the 4 observation points in July for the interference of the other sources are minimized. We used the intersection traffic survey data of all direction for construction of the V.K.T. data, the mobile activities on the roads. ArcGIS application was used for calculating the length of roads in the set radius. The V.K.T. data are multiplied by segment traffic volume and length of roads. As a result, the $NO_x$ concentration can be expressed as linear function formula for V.K.T. with high predictive power. Moreover we separated background concentration and concentrations due to road mobile source. These results can be used for forecasting the effect of traffic demand management plan.

Analysis of Relationship between O3, NO, and NO2 in Riyadh, Saudi Arabia

  • Shareef, Mohammed Mujtaba;Husain, Tahir;Alharbi, Bader
    • Asian Journal of Atmospheric Environment
    • /
    • v.12 no.1
    • /
    • pp.17-29
    • /
    • 2018
  • For the first time in the city of Riyadh, the formation of $O_3$ and its relationship with NO and $NO_2$ ($NO_x$) was investigated. Throughout the summer $O_3$, NO, and $NO_2$ were collected from three locations: residential, industrial, and rural areas. During the sampling period $O_3$ concentrations exceeded 1-hour local standards a few times yet remained consistent with the standards most of the time. The $O_3$ concentrations were observed highest in the rural location and lowest in the industrial area. The diurnal variation of NO followed a double peak: one in the morning and the other in the evening, representing the traffic pattern. Early morning NO peaks were observed in the rural location, which were attributed to the movement of NO from other locations. The $O_3$ concentrations depicted typical pattern, increasing after sunrise and reaching its maximum during midday. The highest $O_3$ concentrations were observed in the rural location followed by the residential and industrial. $NO_2$ photolysis rates were 3-4 times higher compared to other similar investigations, potentially due to intense solar radiation. A strong negative correlation was observed between $NO_x$ and $O_3$ values in the industrial location indicating photochemical activities around the industrial area were higher, likely due to additional $NO_x$ emissions from industries. Regression analysis of $NO_x$ and OX ($O_3+NO_2$) indicated that in residential and industrial locations at nighttime there were large $NO_x$ independent regional contributions which is attributed to VOCs. The Weekend Effect was observed in the city potentially due to the production of the OH radical and subsequent reactions with VOCs implying that the area is VOC-sensitive.

Formation of Optical Fiber Preform Using Octamethylcyclotetrasiloxane (Octamethylcyclotetrasiloxane를 이용한 광섬유 클래드 프리폼 형성)

  • Choi, Jinseok;Lee, Tae Kyun;Park, Seong Gyu;Lee, Ga Hyoung;Jun, Gu Sik;An, Sung Jin
    • Korean Journal of Materials Research
    • /
    • v.28 no.1
    • /
    • pp.6-11
    • /
    • 2018
  • There are various manufacturing processes for pure $SiO_2$ that is used as abrasives, chemicals, filters, and glasses, and in metallurgy and optical industries. In the optical fiber industry, to produce $SiO_2$ preform, $SiCl_4$ is utilized as a raw material. However, the combustion reaction of $SiCl_4$ has caused critical environmental issues, such as ozone deficiency by chlorine compounds, the greenhouse effect by carbon dioxide and corrosive gas such as hydrochloric acid. Thus, finding an alternative source that does not have those environmental issues is important for the future. Octamethylcyclotetrasiloxane (OMCTS or D4) as a chlorine free source is recently promising candidate for the $SiO_2$ preform formation. In this study, we first conducted a vaporizer design to vaporize the OMCTS. The vaporizer for the OMCTS vaporization was produced on the basis of the results of the vaporizer design. The size of the primary particle of the $SiO_2$ formed by OMCTS was less than 100 nm. X-ray diffraction patterns of the $SiO_2$ indicated an amorphous phase. Fourier-transform infrared spectroscopy analysis revealed the Si-O-Si bond without the -OH group.

$SO_2$ and CO Removal Characteristics in Various Applied Voltage of Nonthermal Discharge Plasma in a Crossed DC Magnetic Field (전.자계상의 전원장치변화에 따른 비열방전 플라즈마의 $SO_2$와 CO가스 제거특성)

  • Lee, Geun-Taek;Geum, Sang-Taek;Mun, Jae-Duk
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.3
    • /
    • pp.215-220
    • /
    • 1999
  • $SO_2$and CO gas removal characteristics of a wire-to-cylinder type nonthermal discharge plasma reactor in various applied voltage (-dc, ac, fast rising pulse and high frequency pulse) and a crossed dc magnetic field have been investigated. The experiment has been emphasized on the oxidizing characteristics of $SO_2$ and CO gas by $O_3$ and the applying of a crossed magnetic field, which would induce the cyclotronic and drift motions of electrons making the residual time longer in the removal airgap space. And it also would enhance the energy of electrons and the electrophysicochemical actions to remove the pollutant gases effectively. It is found thatthe corona onset voltage and the breakdown voltage were decreased with increasing the crossed magnetic field and decrease initial fed $SO_2$and CO concentration. As a result, a higher ozone generation and $SO_2$ and CO gas removal rate of 20[%] can be obtained with -dc, ac and fast rising pulse corona discharges in the crossed dc current-induced magnetic field. But high frequency pulse didn't show effect in applying of a crossed magnetic field.

  • PDF