• Title/Summary/Keyword: Ozone effect

Search Result 507, Processing Time 0.027 seconds

The Conceptions of High School Students about Acid Rain, Ozone Layer, and Greenhouse Effect (산성비, 오존층, 온실 효과에 대한 고등학생들의 개념)

  • Han, Jae-Young;Jeong, Yeong-Seon;Noh, Tae-Hee
    • Journal of The Korean Association For Science Education
    • /
    • v.20 no.3
    • /
    • pp.364-370
    • /
    • 2000
  • In this study, 10th-grade students' conceptions concerning acid rain, ozone layer, and greenhouse effect were investigated. A conception test that asked to explain about the three concepts and the relationships among them was administered to 137 students. Analysis of their responses indicated that students had lack of understanding about the definition of acid rain, the difference between greenhouse effect and global warming, and how to prevent the increase in greenhouse effect. They also confused ozone layer with greenhouse effect. Many students thought that there were causal relationships among the increase of acid rain, the destruction of ozone layer, and the increase in greenhouse effect.

  • PDF

Ozone Application for the Bleaching of Unsaturated Coloring Material (오존을 이용한 불포화 색소물질의 탈색반응)

  • Choi, Hyeong-Ki;Chung, Chang-Nam;Kim, Jum-Sik
    • Applied Chemistry for Engineering
    • /
    • v.2 no.3
    • /
    • pp.262-269
    • /
    • 1991
  • Bleaching effect of ozone on unsaturated coloring material was compared quantitatively with the change of composition of reactants through the ozone oxidation of ${\beta}$-carotene. Beeswax colorized by carotenoids was reacted with ozone in water, 0.5 % and 1.0 % sodium hydroxide solution, and 20 % and 95 % acetic acid solution and bleaching effect of each reaction condition was compared with each other. And then the additive effect of hydrogen peroxide was investigated. Decrease of unsaturated double bond of ${\beta}$-carotene was proportioned quantitatively to the bleaching effect of ozone on ${\beta}$-carotene and was in accordance with the bleaching effect on beeswax. The bleaching effect of ozone on coloring material in 1.0 % sodium hydroxide solution was better than any other condition and the absorbance of beeswax at 390 nm was improved to 0.045 with the addition of hydrogen peroxide(2 % of wax). For the bleaching of beeswax, it was concluded that the ozone oxidation was more effective than physical adsorption.

  • PDF

Evaluating Effective Volume and Hydrodynamic Behavior in a Full-Scale Ozone Contactor with CFD Simulation (전산유체역학을 이용한 실규모 오존 접촉에서의 수리거동과 유효 체적 평가에 관한 연구)

  • Park, No-Suk;Mizuno, Tadao;Tsuno, Hiroshi;Bea, Chul-Ho;Lee, Seon-Ju
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.5
    • /
    • pp.656-665
    • /
    • 2004
  • An Ozone reaction model combined with CFD(Computational Fluid Dynamics) technique was developed in this research, in the simulation of ozonation, hydrodynamic behavior as well as reaction model is important because ozone is supplied to treated water as gas ozone. In order to evaluate hydrodynamic behavior in an ozone contactor, CFD technique was applied. CFD technique elucidated hydrodynamic behavior in the selected ozone contactor, which consisted of three main chambers. Three back-mixing zones were found in the contactor. The higher velocities of water were observed in the second and third compartments than that in the first compartment. The flow of the opposite direction to the main flow was observed near the water surface. Based on the results of CFD simulation, the ozone contactor was divided into small compartments. Mass balance equations were established were established in each compartment with reaction terms. This reaction model was intended to predict dissolved ozone concentration, especially. We concluded that the model could predict favorably the mass balance of ozone, namely absorption efficiency of gaseous ozone, dissolved ozone concentration and ozone consumption. After establishing the model, we discussed the effect of concentration of gaseous ozone at inlet, temperature and organic compounds on dissolved ozone concentration.

The Influence of Long-range Transport on Springtime Nocturnal Ozone Enhancement in Seoul (봄철 서울지역 야간 오존농도 상승에 미치는 장거리 수송의 영향)

  • 오인보;김유근
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.4
    • /
    • pp.503-514
    • /
    • 2004
  • In Seoul metropolitan area, nocturnal variation of surface ozone concentrations observed at 27 monitoring sites from 1998 to 2002 showed that high ozone levels occurred frequently during the spring. Frequency distributions for nighttime ozone indicated that elevated concentrations in spring were influenced by advection of different air mass compared to other seasons. Surface wind analysis during the spring revealed that relatively strong southwesterly winds were associated with nocturnal ozone enhancement, which can be attributed to the regional transport of ozone. In order to identify the origin of nocturnal ozone enhancement in spring, 3-day backward trajectories were calculated by HYSPLIT 4 for the episode days and then classified. The results showed that NW, W, and SW flows, indicating influence of polluted air masses from the China continent, have 51% in a]1 the episode days, which suggest that the nocturnal ozone enhancement can occur under the effect of long-range transport of ozone-laden air mass on a regional scale. Case study of nocturnal ozone maxima associated with long-range transport was discussed in more detail in the light of meteorological conditions. Southwesterly synoptic flow along the outer edge of moving high-pressure system was found to be the important cause of nocturnal ozone maxima in Seoul. This flow could lead to be long-range transport of ozone that had effectively accumulated in the stagnating portion of the system located eastern coast of China. Low atmosphere soundings, backward trajectories, and elevated ozone and CO levels at the back-ground tiles gave evidence for regional effects on nocturnal ozone enhancement In Seoul.

Effect of Coagulation, Ozone and UV Post-Process on COD and Color Removal of Textile Wastewater (응집, 오존 및 UV후처리가 염색폐수의 COD와 색도 제거에 미치는 영향)

  • 박영식;안갑환
    • Journal of Environmental Health Sciences
    • /
    • v.27 no.4
    • /
    • pp.93-98
    • /
    • 2001
  • Wastewaters produced in textile industrial processes contain dyes which are not easily amenable to biological treatment. The object of this study is to determine the post-treatment system of biological process for the textile wastewater by comparing three different types of chemical process, which were 1) post-treatment by ozone or UV, 2) post-treatment by coagulation,3) post-treatment by ozone or UV followed by coagulation. In an application ozone or UV as a post-treatment, color was generally decreased with time, however, SCOD removal effect was not that good. When coagulation was used as point-treatment process, the effluent quality was satisfying. Therefore, the application of coagulation process as a post-treatment of biological process would be more desirable than that as a ozone or UV.

  • PDF

Effects of Ambient Ozone Levels on Rice Yield (자연대기수준의 오존농도가 동진벼의 수량에 미치는 영향)

  • 허재선;이충일
    • Korean Journal Plant Pathology
    • /
    • v.14 no.6
    • /
    • pp.720-724
    • /
    • 1998
  • Open-top field chamber study was carried out to investigate effect of ambient ozone level on the yield of rice cultivar 'Dongjin' in Kwangyang area located in the vicinity of the industrial complex of Yechon petrolium refinery and chemical works or Kwangyang Iron and Steel works during the summer of 1997. mean ozone concentration of ambient air during daytime (9:00∼17:00) was revealed to exceed over 40 ppb which is defined to be a critical level causing plant injury and yield reduction in Europe. Yield component analysis showed that there was no significant difference in rice yield between ambient air and charcoal-filtered air. The results suggest that the ambient ozone levels during the exposure period had no effect on yield reduction of rice cultivar 'Dongjin' and it is likely that the cultivar is tolerant to ambient ozone levels.

  • PDF

Characteristics of Ozone Generation by Diameter and Polarity Variation of Corona Wire Electrode (코로나 선전극의 직경과 극성변화에 따른 오존발생특성)

  • Jung, Jae-Seung;Kim, Jin-Gyu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.5
    • /
    • pp.85-90
    • /
    • 2012
  • In this paper, it was investigated experimentally that diameter and polarity variation of corona wire electrode affected to ozone generation of the ozone generator using a wire-to-plate type electrode. The change in the diameter(D) of the corona wire electrode has a great effect upon ozone generation, higher influence appears in the positive corona discharge than the negative corona discharge. In the case of D=0.50[mm], maximum ozone generation and power efficiency could be obtained. However, in the case of smaller D than this, the ozone generation and efficiency decreases slowly and in the case of larger D, the ozone generation decreases rapidly. It means performance decline as an ozone generator. Therefore, ozone generation and power efficiency would increase through simple optimization of the corona electrode specification.

Ozone Treatment for Circulation of Fresh Poultry Meat (신선계육의 유통을 위한 Ozone 처리 효과)

  • 김순동;김일두
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.20 no.5
    • /
    • pp.483-487
    • /
    • 1991
  • The utilization of ozone as a disinfectant for removing poultry meat microorganisms and then cleaning the poultry rinse water was investigated. When microbial suspensions were treated with ozone at 2, 500ppm/min for 40min, microorganisms were not detectable perfectly. The bacteriocidal effect of ozone by temperature was enhanced greater at 7$^{\circ}C$ than $25^{\circ}C$. All poultry meat microorganisms were killed by ozone treatment at 1, 530ppm for 50min. The pathogenic bacteria such as Salmonella sp. were more vulnerable and not detected by ozone treatment for 20min. Ozonation of the suspension for 20min and 50min increased light transmission at 500nm to 58% and 145%, respectively. The order of COD removal was ozone treatment(21%), coagulant((Al)2SO4) treatment(41%), ozone treatment after coagulant treatment(54%).

  • PDF

Disinfection Effect of Chlorine, Chlorine Dioxide end Ozone on Total Coliform in Water

  • Lee, Yoonjin;Kyoungdoo Oh;Byongho Jun;Sangho Nam
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2003.06a
    • /
    • pp.140-143
    • /
    • 2003
  • This research was to determine and compare the inactivation of total coliform as the indicator organism with chlorine, chlorine dioxide and ozone for drinking water treatment. The inactivation of total coliform was experimentally analyzed for the dose of disinfectant, contact time, pH, Temperature and DOC. The experiments for the characterization of inactivation were performed in a series of batch processes with the total coliform as a general indicator organism based on chlorine, chlorine dioxide and ozone as disinfectants. The nearly 2.4, 3.0, 3.9 log inactivation of total coliform killed by injecting 1mg/L at 5 minutes for chlorine, chlorine dioxide and ozone. For the inactivation of 99.9%, Disinfectants required were 1.70, 1.00 and 0.60 mg/L for chlorine, chlorine dioxide and ozone, respectively. The bactericidal effects of disinfectants were decreased as the pH increased in the range of pH 6-9. The influence of pH change on the killing effect of chlorine dioxide was not strong, but that on ozone and free chlorine was sensitive. The bactericidal effects of the disinfectants were increased as the temperature increase. The activation energies were 36,053, 29,822, 24,906 J/mol of chlorine, chlorine dioxide, ozone for coliforms. The inactivation effects were shown in the lowest order of chlorine, chlorine dioxide and ozone.

  • PDF

Ozone Generation Synergy Effects of Three-Phase Voltage Apply Type Superposed Discharge Ozonizer (3상 전압인가형 중첩방전 오존발생기의 오존생성 상승효과)

  • Lee, Byeong-Jun;Lee, Sang-Geun;Song, Hyeon-Jik;Kim, Yeong-Hun;Park, Won-Ju;Lee, Gwang-Sik
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.8
    • /
    • pp.468-476
    • /
    • 2000
  • Nowadays, ozone is mainly utilized for water treatment and home equipments. Although the demand for ozone is increasing, the ozone yield of silent discharge type ozonizer is low. Therefore, it is expected to improve the energy efficiency and ozone yield of an ozonizer. In this paper, a new ozone generation system is proposed. The 60[Hz] three-phase voltage is applied to three-phase superposed discharge type ozonizer(3PSDO) which has three electrodes(central, internal and external electrodes). There is no discharge pause time when three-phase voltage is applied due to 120-degree phase difference of applied voltage. The synergy effect of the three-phase superposed discharge type ozonizer is investigated by comparing with the three sort of single-phase discharge type ozonizer(1PDO). So, three-phase superposed discharge type ozonizer is able to obtain high ozone yield, and optimize discharge space, because this can increase the discharge power at low applied voltage.

  • PDF