• 제목/요약/키워드: Ozone Process

검색결과 421건 처리시간 0.026초

염색폐수 처리공정에서 COD fraction의 변화와 색도처리 (Evaluating the Potential Decolorization by Testing COD Fractions in Textile Wastewater Treatment Processes)

  • 하준수;박후원;김성원;윤예진;유성환;이상협
    • 한국물환경학회지
    • /
    • 제24권5호
    • /
    • pp.537-542
    • /
    • 2008
  • Textile industry has been recognized as an important pollution source due to its consumption of large volumes of water and chemicals. Textile wastewater contains very diverse chemicals in types and composition, among them the presence of dyes is highly visible and undesirable. In spite of these problems, there has not been a proper control for the wastewater because many dyes are difficult to be degraded or decolorized due to their complex structure and synthetic characteristics. This study has been progressed to evaluate more easily the potential decolorization of advanced treatment processes. It has been surveyed with the Y textile complex wastewater treatment plant, the raw wastewater has appeared very difficult biodegradability by 4.7 of $CODcr/BOD_5$ and 1,158.9 degree of color. In view of CODcr fractions, biodegradable COD portion was 46.4%, colloidal COD and real soluble COD was 45.3% and 31.5% each others. From research on unit processes, the degradable coefficient (k) became from 0.065 to $0.125d^{-1}$ by the processes, the decolorization appeared best efficiency by 30.1% (458.4 degree) in pre-ozone process. On the effluent from the biological process, the filterable CODcr became 129.3 mg/L, the biodegradable portion appeared 64.7% (83.6 mg/L), and the fixed dissolved solid (FDS), non-reactivity (NR), appeared very heavy portion by 80.5% (1,659.0 mg/L).

이산화티탄 광촉매 졸(sol)의 실내환경 코팅에 의한 실내공기질 개선 (Improvement of Indoor Air Quality by Coating of Indoor Materials of $TiO_2$ Photocatalyst Sol)

  • 양원호;김대원;정문호;양진섭;박기선
    • 한국환경보건학회지
    • /
    • 제30권2호
    • /
    • pp.92-97
    • /
    • 2004
  • Three methods for VOCs emissions control in indoor air are reduction at the source, ventilation between indoor and outdoor, and removal. The best alternative should be to replace highly emitting sources with sources having low emissions, but the pertinent information on VOCs is not always available from manufactures. Other ways of improving indoor air quality are needed. It is to increase the outside fresh-air flow to dilute the pollutants, but this method would generally provide only a dilution effect without destruction in residence. An ideal alternative to existing technologies would be a chemical oxidation process able to treat large volumes of slightly contaminated air at normal temperature without additional oxidant such as ozone generator and ion generator. Photocatalytic oxidation(PCO) represents such a process. It is characterized by a surface reaction assisted by light radiation inducing the formation of superoxide, hydroperoxide anions, or hydroxyl radicals, which are powerful oxidants. In comparison with other VOCs removal methods, PCO offers several advantages. The purpose of this study was to explore the possibilities for photocatalytic purification of slightly contaminated indoor air by using visible light such as flurescent visible light(FVL). In this study, a PCO of relatively concentrated benzene using common FVL lamps was investigated as batch type and total volatile organic compounds(TVOCs) using a common FVL lamp and penetrated sun light over window. The results of this study shown the possibility of TiO$_2$ photocatalyst application in the area of indoor air quality control.

기상 데이터에서 대기 오염도 요소의 결측치 보완 기법 제안 (Proposal to Supplement the Missing Values of Air Pollution Levels in Meteorological Dataset)

  • 조동철;한희일
    • 한국인터넷방송통신학회논문지
    • /
    • 제21권1호
    • /
    • pp.181-187
    • /
    • 2021
  • 최근 들어 대기오염으로 인한 피해를 줄이기 위하여 다양한 대기오염 요소를 측정, 분석하고 있다. 이 과정에서 다양한 원인으로 인하여 적지 않은 결측치가 발생한다. 이를 보완하기 위해서는 방대한 크기의 학습 데이터를 필요로 한다. 본 논문에서는 적은 양의 학습 데이터를 이용하여 오존, 이산화탄소, 초미세먼지 등을 측정하는 과정에서 발생하는 결측치를 효과적으로 보완하는 통계적 기법을 제안한다. 제안 알고리즘은 우선 기상데이터와 대기오염도 요소 간의 상관관계, p-값 등의 통계정보 분석을 통해 결측치 보완에 긍정적인 영향을 줄 것이라 예상되는 기상데이터 그룹을 추출한 다음, 이들을 분석하여 효율적이고 효과적으로 결측치를 보완하는 기법이다. 제안 알고리즘의 성능을 확인하기 위하여 다양한 실험을 통하여 널리 알려진 대표적인 알고리즘들과 그 특성을 비교분석한다.

염색폐수의 처리를 위한 세라믹 분리막에 대한 고찰 (A Review on Ceramic Based Membranes for Textile Wastewater Treatment)

  • 곽연수;라즈쿠마 파텔
    • 멤브레인
    • /
    • 제32권2호
    • /
    • pp.100-108
    • /
    • 2022
  • 다양한 산업 중에서 섬유 산업은 섬유 염색을 위해 가장 많은 양의 물을 사용하는데, 이는 여러 종류의 염료를 포함한 폐수의 방대한 배출로 이어진다. 염료의 제거를 위한 방법에는 오존 처리, 흡착 등의 다양한 처리 방법이 존재한다. 하지만 이러한 처리 방법은 폐수 재사용의 문제로 인해 처리 가격이 상승하기 때문에 성공적이지 못하다. 이에 대한 대안으로 막분리 공정이 폐수의 염료 처리를 위한 가장 적절한 기술로 보고되고 있다. 이때 사용되는 분리막은 고분자 분리막과 세라믹 분리막으로 나눌 수 있다. 세라믹 분리막의 장점에는 세척의 용이함, 긴 수명, 내열성, 내화학성, 그리고 기계적 안정성이 있다. 세라믹 분리막은 다양한 원료로 만들 수 있으며, 점토, 제올라이트, 플라이 애시와 같은 천연 재료는 저렴하고 구하기 용이하다. 본 리뷰에서 폐수처리는 크게 한외여과(ultrafiltration), 정밀여과(microfiltration), 그리고 나노여과(nanofiltration) 세가지 공정으로 나누어져 있다.

전기분해 염소소독공정의 반응표면분석법을 이용한 차아염소산나트륨 발생 최적화 (Application of Response Surface Methodology to Optimize the Performance of the Electro-Chlorination Process)

  • 주재현;박찬규
    • 한국환경보건학회지
    • /
    • 제48권3호
    • /
    • pp.167-175
    • /
    • 2022
  • Background: Disinfection is essential to provide drinking water from a water source. The disinfection process mainly consists of the use of chlorine and ozone, but when chlorine is used as a disinfectant, the problem of disinfection by-products arises. In order to resolve the issue of disinfection by-products, electro-chlorination technology that produces chlorine-based disinfectants from salt water through electrochemical principles should be applied. Objectives: This study surveys the possibility of optimally producing active chlorine from synthetic NaCl solutions using an electro-chlorination system through RSM. Methods: Response surface methodology (RSM) has been used for modeling and optimizing a variety of water and wastewater treatment processes. This study surveys the possibility of optimally producing active chlorine from synthetic saline solutions using electrolysis through RSM. Various operating parameters, such as distance of electrodes, sodium chloride concentration, electrical potential, and electrolysis time were evaluated. Results: Various operating parameters, such as distance of electrodes, sodium chloride concentration, electrical potential, and electrolysis time were evaluated. A central composite design (CCD) was applied to determine the optimal experimental factors for chlorine production. Conclusions: The concentration of the synthetic NaCl solution and the distance between electrodes had the greatest influence on the generation of hypochlorite disinfectant. The closer the distance between the electrodes and the higher the concentration of the synthetic NaCl solution, the more hypochlorous acid disinfectant was produced.

도시 물 문제 저감을 위한 회복탄력적 사회기반시설 구축: 2. 수질오염 문제 구조적 대안의 내구성 평가 (Establishment of Resilient Infrastructures for the Mitigation of an Urban Water Problem: 2. Robustness Assessment of Structural Alternatives for the Problems of Water Pollution)

  • 정지현;이창민;안진성;김재영;최용주
    • Ecology and Resilient Infrastructure
    • /
    • 제3권3호
    • /
    • pp.182-188
    • /
    • 2016
  • 본 연구는 도시 홍수문제의 구조적 해결방안을 도출하기 위하여 내구성-비용지수 (robustness cost index, RCI)를 수질오염 문제 사례에 재해석 및 적용하였다. 처리기준 산정방식이 다른 하수 처리수 내 내생호르몬 오염과 취수원 원생동물 번성을 대표 사례로 선정하여 기존시설과 대안시설 (구조적 대안)의 내구성 지수 (RI) 값이 1 이상인 경우를 내구성을 확보한 대안으로 판정하고 내구성 지수와 비용지수 (CI)를 결합한 RCI 값을 산정하였다. 하수 처리수 내 내생호르몬 오염은 인체로부터 기인하는 $17{\beta}$-estradiol 을 대상 오염물질로 하여 현재 하수처리시설과 대안시설 (고도처리공정 증축)을 비교하였고, 고도처리공정을 증축한 사례에서 RI뿐만 아니라 RCI 값이 큰 결과가 나타났다. 취수원 원생동물 번성의 경우 크립토스포리디움을 처리하기 위한 소독방안으로 자외선 소독과 오존 소독을 대상으로 RCI를 산정하였고 오존 소독시설이 RCI값이 더 높은 것을 확인하였다. 처리기준이 다른 수질오염사례의 RCI 산정과정과 도출한 값을 바탕으로 재해 발생 시 피해 복구와 피해 방지를 위한 구조적 대안 수립과정의 방향을 제시하고 그 구축전략을 제안하였다.

춘천시 대기 중 가스상 수은 종 농도 특성에 관한 연구 (Characteristics of Atmospheric Speciated Gaseous Mercury in Chuncheon, Korea)

  • 간순영;이승묵;한영지
    • 대한환경공학회지
    • /
    • 제31권5호
    • /
    • pp.382-391
    • /
    • 2009
  • 본 연구에서 2006년 3월부터 2008년 11월까지 측정한 총 가스상 수은(TGM)과 가스상 산화수은(RGM)의 농도는 각각 2.10 ${\pm}$ 1.50 ng/$m^3$, 3.00 ${\pm}$ 3.14 pg/$m^3$으로 나타났다. RGM 농도는 밤보다 낮 시간에 월등히 높은 농도를 보였으며 이는 낮에 고농도로 존재하는 오존 등 산화제에 의한 광화학 반응으로 인하여 가스상 산화수은이 생성되는 것으로 설명할 수 있다. 한편 안개 발생 횟수가 많은 춘천에서는 가스상 산화수은 농도와 오존농도가 특히 안개일에 유의미한 상관관계를 보였다. 이는 액적 상태일 때, 금속수은($Hg^0$)의 산화반응에서 오존이 중요한 역할을 한다는 것을 의미한다. 또한 총 가스상 수은은 대표적인 장거리 이동 오염물질인 CO 및 $PM_{10}$과는 상관관계를 보이는 반면, 국지 오염물질인 $NO_2$와는 상관관계가 없는 것으로 나타났다. 수은의 주요 발생원이 산업시설에서의 화석연료의 연소라는 것을 고려할 때, 산업시설이 부재한 춘천에서는 총 가스상 수은의 농도가 지역 오염원에 의해서는 크게 영향을 받지 않는다는 것으로 판단된다. 그리고 총 가스상 수은의 고농도와 저농도를 대표하는 시료의 역궤적을 계산한 결과, 춘천의 총 가스상 수은 농도에 영향을 주는 지역은 선양, 베이징을 포함한 중국의 산업지역이라는 것을 확인할 수 있었다.

하천수 내 생물학적 안정성에 따른 유기물 특성변화와 오존산화기반 전처리 연구 (Biological stability in the ozone and peroxone pretreatment systems in river water)

  • 박세희;노진형;박지원;맹승규
    • 상하수도학회지
    • /
    • 제32권2호
    • /
    • pp.159-168
    • /
    • 2018
  • Climate change is believed to increase the amount of dissolved organic matter in surface water, as a result of the release of bulk organic matter, which make difficult to achieve a high quality of drinking water via conventional water treatment techniques. Therefore, the natural water treatment techniques, such as managed aquifer recharge (MAR), can be proposed as a alternative method to improve water quality greatly. Removal of bulk organic matter using managed aquifer recharge system is mainly achieved by biodegradation. Biodegradable dissolved organic carbon (BDOC) and assimilable organic carbon (AOC) can be used as water quality indicators for biological stability of drinking water. In this study, we compared the change of BDOC and AOC with respect to pretreatment methods (i.e., ozone or peroxone). The oxidative pretreatment can transform the recalcitrant organic matter into readily biodegradable one (i.e., BDOC and AOC). We also investigated the differences of organic matter characteristics between BDOC and AOC. We observed the decreases in dissolved organic carbon (DOC) and the tryptophan-like fluorescence intensities. Liquid chromatographic - organic carbon detection (LC-OCD) analysis also showed the reduction of the low molecular weight (LMW) fraction (15% removed, less than 500 Da), which is known to be easily biodegradable, and the biopolymers, high molecular weight fractions (66%). Therefore, BDOC consists of a broad range of organic matter characteristics with respect to molecular weight. In AOC, low molecular weight organic matter and biopolymers fraction was reduced by 11 and 6%, respectively. It confirmed that biodegradation by microorganisms as the main removal mechanism in AOC, while BDOC has biodegradation by microorganism as well as the sorption effects from the sand. $O_3$ and $O_3+H_2O_2$ were compared with respect to biological stability and dissolved organic matter characteristics. BDOC and AOC were determined to be about 1.9 times for $O_3$ and about 1.4 times for $O_3+H_2O_2$. It was confirmed that $O_3$ enhanced the biodegradability by increasing LMW dissolved organic matter.

상수처리과정 중 제초제 molinate의 제거 (Removal of Herbicide Molinate during treatment Processes for Drinking Water)

  • 박주황;박종우;김종수;김장억
    • Applied Biological Chemistry
    • /
    • 제45권3호
    • /
    • pp.145-151
    • /
    • 2002
  • 수도용 제초제로 널리 사용되는 molinate는 물에 대한 용해도가 매우 크기 때문에 상수원수로 유입될 가능성이 있다. 상수원수에 molinate가 유입되었을 경우 상수처리과정 중에서의 제거효율을 알아보기 위하여 본 연구를 수행하였다. 상수처리과정중 응집제로 poly aluminium chloride(PAC)를 사용하였을 경우에는 molinate는 거의 제거되지 않는 것으로 나타났다. 소독제로 NaCIO를 사용한 염소처리과정에서는 4시간까지 염소투입량을 증가시켜 줌에 따라서 $20.0%{\sim}39.8%$의 제거율을 나타내었다. 고도정수처리과정에 해당되는 오존접촉과정에서는 접촉시간을 1시간까지 두었을 때 $28.9%{\sim}$58.2%의 제거율을 나타내었다. 활성탄처리과정의 경우는 입상활성탄의 첨가량 달리 하였을 때 30분의 접촉시간이 지난 후 90%이상의 제거효율을 나타내었으며, 1시간 후에는 완전히 제거되는 것으로 나타났다. 활성탄의 형태에 따른 제거효율은 비표면적이 더 널은 분말활성탄이 입상활성탄을 사용하였을 때보다 다 높게 나타났다. 고도정수처리과정인 오존접촉과 활성탄처리과정을 연속적으로 행한 결과 비교적 짬은 처리 시간에도 불구하고 $93.9%{\sim}100% 제거되었다. 상수처리의 각 과정별 molinatr치 제거율을 계산하여 모식화한 결과 전체 system에서의 효율은 99.5%로 나타나 수중 molinate의 제거에 상당히 효율적인 것으로 나타났다.

난지도 지역의 대기수은 지화학 (Geochemistry of Total Gaseous Mercury in Nan-Ji-Do, Seoul, Korea)

  • 김민영;이강웅;신재영;김기현
    • 한국지구과학회지
    • /
    • 제21권5호
    • /
    • pp.611-622
    • /
    • 2000
  • 대규모 면오염원으로 간주되는 난지도지역을 중심으로 2000년 봄 기간중 대기-지표간 수은의 교환율을 측정하고, 측정자료를 기초로 수은의 교환현상을 분석하였다. 측정결과에 의하면 난지도지역은 대규모 면오염원으로 대량의 수은을 배출할 뿐아니라 동시에 대규모의 침적을 경험하는 것으로 나타났다. 일주기별로 농도, 농도구배, 플럭스의 절대치를 분석한 결과 대규모 배출과 침적은 오후시간대에 왕성하게 진행되는 것으로 나타났다. 그러나 이들의 발생빈도에 대한 분석결과는 배출이 새벽 또는 저녁에 빈번하게 발생하는데 비해, 침적은 주로 오후시간대에 집중된다는 것을 확인하였다. 풍향대별로 발생빈도와 교환율을 비교한 바에 따르면, 대규모 침적을 유도하는 외부배출원이 동쪽지역에 위치해 있다는 것을 추정할 수 있었다. 특정 풍향에서 침적이 집중된 점을 감안하여, 침적이 집중된 방향의 자료군과 배출이 지배적으로 발견된 전체자료를 이용하여 조건별 환경인자의 변화동향을 배출/침적비로 환산하여 비교하였다. 그 결과 대부분의 오염인자들의 농도는 외부여건에 따라 규칙적인 변화양상을 보여주었다. 상관분석의 결과는 이들의 거동이 교환현상의 수직적인 방향-침적 또는 배출-의영향을 민감하게 반영하는 것으로 나타났다. 요인분석의 결과는 배출시에 기온과 같은 요인에 의해 유도되는 부분이 그리고 침적시에는 기온, 오존, 비메탄계 탄화수소와 같이 외부인자의 영향을 반영하는 요인들이 복합적으로 중요하게 작용할 수 있다는 점을 시사하였다. 난지도지역을 중심으로 한 수은의 자료를 추정한 결과 연간규모로 약 6kg의 수은이 배출되는 것으로 나타났다.

  • PDF