• Title/Summary/Keyword: Oxygenation

Search Result 403, Processing Time 0.022 seconds

The effects of oxygen annealing on the twin structure in the melt textured YBCO superconductors (용융 응고법으로 제조된 YBCO초전도체에서 twin structure가 산소어닐링에 미치는 영향)

  • 홍인기;황현석;한영희;성태현;노광수
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2002.02a
    • /
    • pp.17-19
    • /
    • 2002
  • Melt textured YBCO superconductors were fabricated by the top seeding method using Sml.8($Sm_{1.8}$ $Ba_{2.4}$ $Cu_{3.4}$$O_{7-Y}$) seed. We investigated the twin structures using the optical microscope, SEM and TEM. The twin structures formed during the tetragonal to orthorhombic transition which occurred at $450^{\circ}C$ in sample oxygen annealing. The twin structures were clearly observed by SEM due to the chemical etching effects. The lengths of twin structures were increased as the oxygenation heat treatment time increased from 1hr to 10hr. We investigated twin structure by TEM. The twin spaces were considered to be related to the oxygen contents. The results suggested an oxygen diffusion model for the formation of the twin lengths.

  • PDF

Optical imaging of epileptic activity and epilepsy treatments in neocortex

  • Suh, Min-Ah
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2009.02a
    • /
    • pp.427-428
    • /
    • 2009
  • Optical imaging offers excellent spatio-temporal sensitivity that is unparalleled by any other perfusion based imaging techniques. We used in vivo optical recording of intrinsic signals (ORIS) to map neurovascular hemodynamics of perfusion, oximetry and membrane potential during epileptic events in rat and mouse neocortex. Studies of hemodynamic changes with ORIS alone were also performed in human. Laboratory studies in rodent epilepsy models have demonstrated a persistent increase in deoxygenated hemoglobin (Hbr) and a decrease in tissue oxygenation during interictal spikes and ictal events. This "epileptic dip", like the "initial dip" recorded during normal sensory processing, implies that the enormous rise in cerebral blood flow (CBF) is inadequate to meet the increased metabolic demands associated with synchronized epileptic activity. These findings are critically important to the interpretation of the perfusion-based imaging studies, such as fMRI. In addition, we visualized the effect of direct cortical electrical stimulation, an alterative epilepsy treatment. The optical data following direct cortical electrical stimulation showed that hemodynamic signals are sensitive to different electrical stimulation parameters. Furthermore, our recent data demonstrated that the application of unilateral electrical stimulation is able to elicit bilateral hemodynamic responses in rat neocortex.

  • PDF

Biodegradation of BTEX (benzene, toluene, ethylbenzene, xylene isomers) from organic solvent tolerant bacterium, Pseudomonas savastanoi BCNU 106

  • Kim, Jong-Su;Park, Hyeong-Cheol;Jo, Su-Dong;Kim, Gi-Uk;Bae, Yun-Wi;Mun, Ja-Yeong;Jeong, Yeong-Gi;Ju, U-Hong
    • 한국생물공학회:학술대회논문집
    • /
    • 2003.04a
    • /
    • pp.386-389
    • /
    • 2003
  • Organic solvent tolerance bacteria, Pseudomonas savastanoi BCNU 106 could utilize a high contentration of benzene, toluene, ethylbenzene, xylene isomers (BTEX) as a sole carbon source. It was founded that strain BCNU 106 transformed o-xylene to 2-methylbenzyl alcohol, 2-methylbenzoic acid through direct oxygenation of methyl residue on GC-MS analysis.

  • PDF

Novel oxygenation for lipopeptide production from Bacillus sp. GB16

  • Lee, Baek-Seok;Lee, Jae-Woo;Shin, Haw-Shook;Choi, Sung-Won;Choi, Ki-Hyun;Lee, Jae-Ho;Kim, Eun-Ki
    • 한국생물공학회:학술대회논문집
    • /
    • 2003.04a
    • /
    • pp.240-244
    • /
    • 2003
  • A novel integrated method for increasing dissolved oxygen concentration in culture media has been developed. It involves adding hydrogen peroxide to the medium, which is then decomposed to oxygen and water by catalase and adding vegetable oil to the medium as antifoam agent and oxygen vector. A new apparatus for automated addition of hydrogen peroxide to the bioreactor to keep the dissolved oxygen concentration constant over the range $10-100%\;{\pm}\;5%$ was tested. A significant increase (over threefold) of cultivation time was obtained while the dissolved oxygen concentration remained stable ($30%\;{\pm}\;5%$). Therefore, use of corn oil mixed with Ca-stearate as oxygen vector and antifoam and hydrogen peroxide as oxygen source to control excessive foam that was generated by microorganism biosurfactant, GB16-BS produced at Bacillus sp. GB16 cultivation was appropriate for stable cultivation.

  • PDF

Tracheostomy Assisted with Emergency Bypass System in Severe Tracheal Stenosis (고도 기관 협착에서 응급 체외 순환기를 이용한 기관절개술)

  • Choi, Si-Young;Kim, Yong-Hwan
    • Journal of Chest Surgery
    • /
    • v.40 no.12
    • /
    • pp.874-877
    • /
    • 2007
  • Airway management is difficult problem in severe tracheal stenosis. A total airway obstruction during the procedure resulted in a fatal outcome. We suggest a tracheostomy assisted with an emergency bypass system as a possible method for avoiding this complication.

Refractory Coronary Artery Spasm after Minimally Invasive Direct Coronary Artery Bypass Grafting

  • Ju, Min-Ho;Kim, Joon-Bum;Kim, Hee-Jung;Choo, Suk-Jung
    • Journal of Chest Surgery
    • /
    • v.44 no.4
    • /
    • pp.288-291
    • /
    • 2011
  • Postoperative coronary arterial spasm is a rare but potentially fatal complication. A 51-year-old male patient with a history of a reactive ergonovine stress test coronary angiogram developed refractory coronary artery spasm after undergoing minimally invasive direct coronary artery bypass grafting of the left anterior descending coronary artery. The patient was successfully managed with rapid implementation of intra-aortic balloon-pump counter pulsation and extracorporeal membrane oxygenation.

Diffuse alveolar hemorrhage and recombinant factor VIIa treatment in pediatric patients

  • Park, Jeong A
    • Clinical and Experimental Pediatrics
    • /
    • v.59 no.3
    • /
    • pp.105-113
    • /
    • 2016
  • Diffuse alveolar hemorrhage (DAH) is a life-threatening pulmonary complication in patients with hematologic malignancies or autoimmune disorders. The current treatment options, which include corticosteroids, transfusions, extracorporeal membrane oxygenation (ECMO), and immunosuppressants, have been limited and largely unsuccessful. Recombinant activated factor VII (rFVIIa) has been successfully administered, either systemically or bronchoscopically, to adults for the treatment of DAH, but there are few data on its use in pediatric patients. The current literature in the PubMed database was reviewed to evaluate the efficacy and risk of rFVIIa treatment for DAH in pediatric patients. This review discusses the diagnosis and treatment of DAH, as well as a new treatment paradigm that includes rFVIIa. Additionally, the risks and benefits of off-label use of rFVIIa in pediatric patients are discussed.

A Carbon Monoxide Poisoning Case in Which Hyperbaric Oxygen Therapy Was Not Possible Due to Iatrogenic Pneumothorax after Unnecessary Central Catheterization

  • Kim, Hyung Il;Oh, Seong Beom
    • Journal of Trauma and Injury
    • /
    • v.32 no.4
    • /
    • pp.252-257
    • /
    • 2019
  • Hyperbaric oxygen therapy (HBOT) is used to treat carbon monoxide (CO) poisoning. However, untreated pneumothorax is an absolute contraindication for HBOT. More caution is needed with regard to monoplace hyperbaric chambers, as patient monitoring and life-saving procedures are impossible inside these chambers. Central catheterization is frequently used for various conditions, but unnecessary catheterization must be avoided because of the risk of infection and mechanical complications. Herein, we describe a case of CO poisoning in which iatrogenic pneumothorax developed after unnecessary subclavian central catheterization. The patient did not need to be catheterized, and HBOT could not be performed because of the pneumothorax. Hence, this case reminds us of basic-but nonetheless important-principles of catheterization.

The Effects of Physiological Heating and Exercise on the Optical Properties of Biological Tissue. (가열과 운동에 의한 생체조직내의 생리적 변화에 따른 광학적 특성의 변화에 관한 연구)

  • Lim, Hyun-Soo;Huh, Woong
    • Journal of Biomedical Engineering Research
    • /
    • v.14 no.1
    • /
    • pp.81-88
    • /
    • 1993
  • This paper is the study of the reflectance of light from biological tissue for red and Infrared wavelengths and relates the acquired reflectance data to expected physiological changes within the skin and muscle layers associated with heat and exercise. The instrument was disigned to collect data from the calf muscle in human subjects with probe located at the surface of skin. Rapid data acquisition method allowed monitoring of rapid changes in reflecttance due to a stimulus. This study demonstrates that changes in O2 saturation and blood fractional volume expected within the dermis and muscle layers were asserted by examining the slopes of the plotted index for heat and exercise. The results presented in thls study support the claim that reflectance can separately discriminate between changes of blood volume and oxygenation in muscle and in skin. The data demonstrate the ability to measure consistent changes In tissue optical properties during exercise and heat.

  • PDF

A study on the Optimal Condition for Application with Extracorporeal Membrane Oxygenation (ECMO 시스템 적용을 위한 최적화 조건에 관한 연구)

  • Kim, Jae-Yeol;Song, Min-Jong;You, Sin;Ma, Sang-Dong;Kim, Chang-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.09a
    • /
    • pp.13-18
    • /
    • 2001
  • The ECMO system, including umbilical cord and membrane type oxygenator was connected with extracorporeal circulation unit, was applied to the fetus growth model of goat. The maximum survival time of goat fetus was 48 hours. Average blood rate for the extracorporeal circulation was $223{\pm}15.2 ml/min.$ The survival time of fetus was deeply related to body temperature, blood circulation and water temperature, anesthetized time, and fetus weights. Extern variables that are composed of anesthetized time, fetus weights, change of hemoglobin, circuit pressure, related to the survival time for fetus corrected the problem of previous ECMO model that is controlled by roller pump. It is directly delivered to heart on load. Applying the results from new ECMO model, further research will provide to the system of ECMO for human.

  • PDF