Remedation of petroleum impacted filled land using of various in situ technology

  • 안훈기;김재형;고경연;서형기;임은진
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2004년도 임시총회 및 추계학술발표회
    • /
    • pp.286-289
    • /
    • 2004
  • On site, In situ soil remediation technologies are very important among the remediation technologies and in general efficiency of these technologies are turned to site characterization and environmental condition. specially using of only one technology has so many limitation factors. for example, existing state of tailing and channeling and so on. actually, filled land have high concentration cation exchange capacity because of existence in abundance soil organic matter. Therefore we used various on site in Situ technologies by phase for overcome the limitation factors. Target site is petroleum (diesel) impacted filled land and using technologies are SVE(Soil Vapor Extraction), BV(Bioventing), Bioremediation, Soil flushing, Chemical oxidation.

  • PDF

비친수성유기물질(HOC)로 오염된 토양의 정화를 위한 동전기-생물활성화공정의 개발

  • 양지원;김상준;박지연;이유진;기대정
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2003년도 추계학술발표회
    • /
    • pp.326-329
    • /
    • 2003
  • When an electrokinetic process is applied to a HOC-contaminated soil, hybrid types combined with soil flushing, chemical oxidation, and bioremediation are generally used. Especially when the electrokinetic process is combined with bioremediation, the hybrid technology can solve several limits of bioremediation such as low microbial mobility, low soil temperature, and shortage of nutrients in subsurface circumstance. Because microbial surface is charged negatively, the microorganism moves from cathode to anode under electrical field. In this study, mixed culture mainly-consisted by Pseudomonas sp. was applied to remediate pentadecane-contaminated kaolinite with particle size less than 300${\mu}{\textrm}{m}$. This remediation system was named ‘electrokinetic bioaugmentation’ and consisted of model aquifer, electrode reservoirs, bioreactor, power supply, and pump. The mixed culture above 0.5 of optical density in bioreactor was supplied to two reservoirs and penetrated soil when the electric current was applied. To enhance the removal efficiency, the optimal medium composition, electric current, and voltage were investigated.

  • PDF

용선예비처리용 $Al_2O_3-SiC-C$계 내화물 개발 (Development of $Al_2O_3-SiC-C$ Refractory for Hot Metal Pretreatment)

  • 김의호;이석한;이석향;서병길;박정민;이재옥
    • 한국세라믹학회지
    • /
    • 제23권5호
    • /
    • pp.86-92
    • /
    • 1986
  • As there is a growing trend to make high quality steel improving production efficiency and utilizing slag as resources the technologies of hot metal pretreatment have been progressed to meet these demands. Although mill scale $Na_2CO_3$ and CaO used as fluxes proved to be excellent agents then can severely corrode refractories such as chamotte and high alumina for torpedo or open ladle car. Thus it was considered necessary to develop new refractories which can endure suchy conditions. Desulfurization fluxes vastly used in POSCO are $CaCO_3$ and CaO Recent trials have been made by testing phenol resin bonded $Al_2O_3-SiC-C$ bricks in torpedo ladle car for hot metal pretreatment. The results showed that the life of this brick became about 1.2 times longer than that of foreign products. And the crushing strength M.O.R corrosion resistance and oxidation resistance were tested.

  • PDF

난분해성 유기물질 제거를 위한 오존/촉매 공정의 비교에 관한 연구 (A Comparative Study of Catalytic Ozone processes for Removal of Refractory Organics)

  • 이규환;이유미;이동석
    • 산업기술연구
    • /
    • 제26권A호
    • /
    • pp.199-205
    • /
    • 2006
  • Ozone alone and catalytic ozone processes were introduced for treatment of humic acid, which is representative refractory organic compound. The treatment efficiencies of humic acid in each process were analyzed in pH variation, DOC removal, and $UV_{254}$ decrease. Mn loaded GAC catalyst was prepared by loading potassium permanganate onto the granular activated carbon surface. BCM-GAC and BCM-Silica gel catalyst were prepared by BCM. $UV_{254}$ decrease in all processes was comparatively high with efficiency over 87%. DOC removal in ozone/GAC process was the highest with 78%, and removal rates for other processes followed the order ozone/BCM-GAC(62%) > ozone/BCM-silica gel(45%) > ozone/silica gel(43%) > ozone/Mn Loaded GAC(42%) > ozone alone(37%).

  • PDF

UV-B가 보리(Hordeum vulgare L.)잎의 광합성 전자전달에 미치는 영향 (The Effects of W-B Radiation on Photosynthetic Electron Transport of Baney (Hondeum vulgare L) Leaves)

  • 박강은;정화숙
    • 한국환경과학회지
    • /
    • 제6권4호
    • /
    • pp.369-378
    • /
    • 1997
  • The effects of various intensity of W-B on barley seeding were investigated by PS I and II activities and chlorophyll fluorescence. The Inhibitory effect of UV-B radiation on electron transport activity was Increased as the intensity of UV-B Irradiation was increased. Especially, PS I is more sensitive to UV-B radiation than PS I is. By the addition of uncle electron donor, DPC, to the chloroplasts of the barley seedlings treated with UV-B, the photoreduction of DCPIP was recovered by only 1 IBI on electron transport activity. However, the activity of PS II was Inhibited by 45% by the treatment with UV-B, but recovered it only 11% by the addition of DPC. These suggest that other sites besides the oxidation site of PS II may be affected more by UV-B Irradiation. As the intensify of UV-B was Increased, Fo was Increased while Fv was decreased, and thus Fv/Fm was decreased. This means that photochemical efficiency was reduced. With this parameters, it might be that UV-B radiation affected adversely to around PS II.

  • PDF

FRP보강 그라우팅에 의한 단층대의 터널 안정성 분석 및 설계 사례 연구 (A Case Study of Analysis and Design for the Tunnel Stablization in Fault Zone by FRP Reinforced Grouting Method)

  • 박종호;최용기;박영목;권오엽;이재봉
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.121-128
    • /
    • 2001
  • This is a case study of stability analysis and reinforcement design for the tunnel where the collapse of the entrance slops occured along the fault zone developed in the bed rock. According to the site investigation, the main factor of sliding is the influence of fault gouge and heavy rainfall. Considering the in-situ condition, the versatile reinforcement methods is needed, and so the close investigation on the site area was accompanied with the stability analysis of tunnel and slops. The FRP(Fiberglass reinforced plastic) grouting method improved the defect of Steel Umbrella Arch Method, such as oxidation, low work efficiency, the material's heavy weight, is adapted as the reinforcement methods.

  • PDF

계장화 압입시험법을 이용한 보일러 설비의 고온 기계적 물성 측정과 수명 평가 (High-temperature Mechanical Properties Measurement and Life Assessment of Boiler Equipment by Instrumented Indentation Technique)

  • 노동성;홍정화;김광호;이정준
    • 한국안전학회지
    • /
    • 제24권3호
    • /
    • pp.1-6
    • /
    • 2009
  • Recently power plants and oil refineries are focusing on capacity enlargement for better efficiency through higher temperature and higher pressure. Thickness of boiler tubes becomes lessened due to oxidation and erasion caused by high temperature bums gas flowing over tubes outside. Accordingly, mechanical stress of tubes is increasing and that is a critical factor to make a crack and fracture. To prevent those sorts of accidents, aging assessment for proper periodic repair and replacement should be conducted reliably and reasonably. We performed IIT test on Cr-Mo steel, one of the most heat-resistant materials for facilities in power plants, and we report the test result and the considerable effectiveness of IIT test.

집적화된 광 싸이리스터와 수직구조 레이저를 이용한 광 로직 AND/OR 게이트에 관한 연구 (Optical AND/OR gates based on monolithically integrated vertical cavity laser with depleted optical thyristor)

  • 김두근;정인일;최영완;최운경
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 한국정보통신설비학회 2006년도 하계학술대회
    • /
    • pp.19-23
    • /
    • 2006
  • Latching optical switches and optical logic gates AND and OR are demonstrated, for the first time, by the monolithic integration of a vertical cavity lasers with depleted optical thyristor structure, which have not only a low threshold current with 0.65 mA. but also a high on/off contrast ratio more than 50 dB. By simple operating technique with changing a reference switching voltage, this single device operates as two logic functions, optical logic AND and OR. The thyristor laser fabricated using the oxidation process achieved a high optical output power efficiency and a high sensitivity to the optical input light.

  • PDF

알루미늄 코팅처리 스테인레스강의 융탄산염 내부식성 (The corrosion-resistant of Al-coated xstainless in molten carbonate)

  • 조남웅;장세기;전재호;신정철
    • 한국표면공학회지
    • /
    • 제31권1호
    • /
    • pp.3-11
    • /
    • 1998
  • Molten Carbonate Fuel cell is a promising new type electric power generation system which can achieve high efficiency, lower matrrial cost and high operating temperature Making internal reforming possible. Although the development of the MCEC is progressing rapidly toward commercialization, two important tchological problems such as dissolution of NiO cathode and not corrosion of metallic separator plate must be resolved. Because MCFC is operated at $650^{\circ}C$ and the electrolyte is very corrosive, corrosion-resistance of separator plated against oxidation abd molten carbonate is required. Al-coating on separator material for corrosion-resistance was carried out by painting, thermal spraying. hot dipping and vacuum vapour deposition. The corrosion of Al-coated STS 316S and 316L in molten carbonate at $700^{\circ}C$was studied. Vacuum vapour deposition and thermal spraing for Al-coating on STS 310S and 316L were the most effective methods for protecting thestainless steel corrosion in molten carbonate.

  • PDF

공업로용 무화염식 축열버너의 국산화 개발 (The Development of Flameless Regenerative Burner for the Industrial Furnaces)

  • 김원배;양제복
    • 한국연소학회지
    • /
    • 제15권2호
    • /
    • pp.27-33
    • /
    • 2010
  • Recently, much attention has been paid to utilizing highly preheated air up to $1,000^{\circ}C$ through waste gas in industrial furnaces. The regenerative burner technology has shown to provide significant reduction in energy consumption (up to 60%), downsizing of the equipment (about 30%) and lower emissions (about 30%) while maintaining high thermal performance of the system since 2000. The object of this study is to develop the flameless regenerative burner for industrial furnaces based on the FLOX(Flameless Oxidation) principle and it has been designed and manufactured as pilot scale. Performance tests are experimentally done and their results are discussed. They showed 1) a very good uniformity in temperature distribution, 2) about 100 ppm in NOx at the temperature $1,300^{\circ}C$, 3) about 95% in temperature efficiency. Besides, the regenerative burner has advantage in easy maintenance and high usage rate of regenerator due to the separate and portable type of heat exchanger.